911 resultados para SIZE RANGE


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of manganese on gain refinement of a commercial AZ31 alloy has been investigated using an Al-60%Mn master alloy splatter as an alloying additive at 730 degrees C in aluminium titanite crucibles. It is shown that grain refinement by manganese is readily achievable in AZ31. Electron microprobe analyses reveal that prior to the addition of extra manganese the majority of the intermetallic particles found in AZ31 are of the AL(8)Mn(5) type. However, after the addition of extra manganese in the range from 0.1% to 0.8%, the predominant group of intermetallic particles changes to the metastable AlMn type. This leads to a hypothesis that the metastable AlMn intermetallic particles are more effective than Al8Mn5 as nucleation sites for magnesium grains. The hypothesis is supported by the observation that a long period of holding at 730 degrees C leads to an increase in grain size, due probably to the transformation of the metastable AlMn to the stable Al8Mn5. The hypothesis has also been used to understand the mechanism of grain refinement by superheating.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The microstructures and electrolytic properties of YxCe1-xO2-x/2 (x = 0.10-0.25) electrolytes with average grain size in the range 90 nm-1.7 mu m were systematically investigated. Through detailed transmission electron microscopy characterization, nanosized domains were observed. The relationship of the domains, the doping level and grain sizes were determined, and their impacts on the electrolytic properties were systematically studied. It was found that the formation of domains has a negative impact on the electrolytic properties, so that electrolytic properties can be adjusted through careful control of domain formation, doping level and grain size. (c) 2006 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The particle size of the bed sediments in or on many natural streams, alluvial fans, laboratory flumes, irrigation canals and mine waste deltas varies exponentially with distance along the stream. A plot of the available worldwide exponential bed particle size diminution coefficient data against stream length is presented which shows that all the data lie within a single narrow band extending over virtually the whole range of stream lengths and bed sediment particle sizes found on Earth. This correlation applies to both natural and artificial flows with both sand and gravel beds, irrespective of either the solids concentration or whether normal or reverse sorting occurs. This strongly suggests that there are common mechanisms underlying the exponential diminution of bed particles in subaerial aqueous flows of all kinds. Thus existing models of sorting and abrasion applicable to some such flows may be applicable to others. A comparison of exponential laboratory abrasion and field diminution coefficients suggests that abrasion is unlikely to be significant in gravel and sand bed streams shorter than about 10 km to 100 km, and about 500 km, respectively. Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article describes a 6-yr study of the radial growth rates (RGR, mm yr-1) of Rhizocarpon section Rhizocarpon thalli on a talus slope at Snoqualmie Pass in the Cascade Range, Washington State, United States (47°27'N; 121°26'W). At the end of the growth period, 32 of a total of 39 thalli had exhibited a positive RGR, and 7 of a total of 39 thalli showed no measurable growth. Mean RGR of all thalli was 0.07 mm yr-1 (range, 0-0.19 mm, SD = 0.06). Analysis of variance suggested no significant variation in RGR in successive growth periods, but significant differences were present both within and between thalli. The slope of a boulder facet did not influence RGR, but growth was affected by aspect, the least growth being observed on north-northwest facets. A plot of RGR against thallus diameter revealed a wide scatter of data points with little evidence for a significant change in growth with thallus size. Hence, the study showed that the RGR of Rhizocarpon thalli at Snoqualmie is extremely slow and highly variable and significantly less than estimates based on lichenometry. To determine the growth curve of a yellow-green Rhizocarpon by direct measurement at such a site would require a large sample of thalli and careful standardization of the species studied, the aspect conditions under which the thalli were measured, and the initial hypothallus width of the thalli. © 2005 Regents of the University of Colorado.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Stӧber process is commonly used for synthesising spherical silica particles. This article reports the first comprehensive study of how the process variables can be used to obtain monodispersed particles of specific size. The modal particle size could be selected within in the range 20 – 500 nm. There is great therapeutic potential for bioactive glass nanoparticles, as they can be internalised within cells and perform sustained delivery of active ions. Biodegradable bioactive glass nanoparticles are also used in nanocomposites. Modification of the Stӧber process so that the particles can contain cations such as calcium, while maintaining monodispersity, is desirable. Here, while calcium incorporation is achieved, with a homogenous distribution, careful characterisation shows that much of the calcium is not incorporated. A maximum of 10 mol% CaO can be achieved and previous reports are likely to have overestimated the amount of calcium incorporated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study utilized the advanced technology provided by automated perimeters to investigate the hypothesis that patients with retinitis pigmentosa behave atypically over the dynamic range and to concurrently determine the influence of extraneous factors on the format of the normal perimetric sensitivity profile. The perimetric processing of some patients with retinitis pigmentosa was considered to be abnormal in either the temporal and/or the spatial domain. The standard size III stimulus saturated the central regions and was thus ineffective in detecting early depressions in sensitivity in these areas. When stimulus size was scaled in inverse proportion to the square root of ganglion cell receptive field density (M-scaled), isosensitive profiles did not result, although cortical representation was theoretically equivalent across the visual field. It was conjectured that this was due to variations in the ganglion cell characteristics with increasing peripheral angle, most notably spatial summation. It was concluded that the development of perimetric routines incorporating stimulus sizes adjusted in proportion to the coverage factor of retinal ganglion cells would enhance the diagnostic capacity of perimetry. Good general and local correspondence was found between perimetric sensitivity and the available retinal cell counts. Intraocular light scatter arising both from simulations and media opacities depressed perimetric sensitivity. Attenuation was greater centrally for the smaller LED stimuli, whereas the reverse was true for the larger projected stimuli. Prior perimetric experience and pupil size also demonstrated eccentricity-dependent effect on sensitivity. Practice improved perimetric sensitivity for projected stimuli at eccentricities greater than or equal to 30o; particularly in the superior region. Increase in pupil size for LED stimuli enhanced sensitivity at eccentricities greater than 10o. Conversely, microfluctuation in the accommodative response during perimetric examination and the correction of peripheral refractive error had no significant influence on perimetric sensitivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article is a first step towards addressing a gap in the field of organisational resilience research by examining how small and medium enterprises (SME) manage the threat and actuality of extreme events. Pilot research found that the managerial framing of extreme events varied by a range of organisational factors. This finding informed further examination of the contextual nature of the resilience concept. To date, large organisations have been the traditional focus of empirical work and theorising in this area; yet the heterogeneous SME sector makes up approximately 99% of UK industry and routinely operates under conditions of uncertainty. In a comparative study examining UK organisational resilience, it emerged that SME participants had both a distinctive perspective and approach to resilience when compared to participants from larger organisations. This article presents a subset of data from 11 SME decision-makers. The relationship between resilience capabilities, such as flexibility and adaptation, is interrogated in relation to organisational size. The data suggest limitations of applying a one-size-fits-all organisation solution (managerial or policy) to creating resilience. This study forms the basis for survey work examining the extent to which resilience is an organisationally contingent concept in practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE. The purpose of this study was to evaluate the potential of the portable Grand Seiko FR-5000 autorefractor to allow objective, continuous, open-field measurement of accommodation and pupil size for the investigation of the visual response to real-world environments and changes in the optical components of the eye. METHODS. The FR-5000 projects a pair of infrared horizontal and vertical lines on either side of fixation, analyzing the separation of the bars in the reflected image. The measurement bars were turned on permanently and the video output of the FR-5000 fed into a PC for real-time analysis. The calibration between infrared bar separation and the refractive error was assessed over a range of 10.0 D with a model eye. Tolerance to longitudinal instrument head shift was investigated over a ±15 mm range and to eye alignment away from the visual axis over eccentricities up to 25.0°. The minimum pupil size for measurement was determined with a model eye. RESULTS. The separation of the measurement bars changed linearly (r = 0.99), allowing continuous online analysis of the refractive state at 60 Hz temporal and approximately 0.01 D system resolution with pupils >2 mm. The pupil edge could be analyzed on the diagonal axes at the same rate with a system resolution of approximately 0.05 mm. The measurement of accommodation and pupil size were affected by eccentricity of viewing and instrument focusing inaccuracies. CONCLUSIONS. The small size of the instrument together with its resolution and temporal properties and ability to measure through a 2 mm pupil make it useful for the measurement of dynamic accommodation and pupil responses in confined environments, although good eye alignment is important. Copyright © 2006 American Academy of Optometry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The internal optics of the recent models of the Shin-Nippon SRW-5000 autorefractor (also marketed as the Grand Seiko WV-500) have been modified by the manufacturer so that the infrared measurement ring has been replaced by pairs of horizontal and vertical infrared bars, on either side of fixation. The binocular, open field-of-view, allowing the accommodative state to be objectively monitored while a natural environment is viewed, has made the SRW-5000 a valuable tool in further understanding the nature of the oculomotor response. It is shown that the root-mean-square of model eye measures was least (0.017 ± 0.002D) when the separation of the horizontal measurement bars were averaged twice. The separation of the horizontal bars changes by 3.59 pixels/dioptre (r2 = 0.99), allowing continuous on-line analysis of the refractive state at up to 60 Hz temporal resolution to an accuracy of <0.001D, with pupils >3 mm. The pupil edge is not obscured in the diagonal axis by the measurement bars, unlike the ring of the original optics, so in the newer model pupil size can be measured simultaneously at the same rate with a resolution of <0.001 mm. The measurements of accommodation and pupil size are relatively unaffected by eccentricity of viewing up to ±10° from the visual axis and instrument focusing inaccuracies over a range of 10 mm towards the eye and 5 mm away from the eye. The resolution and temporal properties of the analysis are therefore ideal for the simultaneous measurement of dynamic accommodation and pupil responses. © 2004 The College of Optometrists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Threshold stress intensity values, ranging from ∼6 to 16 MN m −3/2 can be obtained in powder-formed Nimonic AP1 by changing the microstructure. The threshold and low crack growth rate behaviour at room temperature of a number of widely differing API microstructures, with both ‘necklace’ and fully recrystallized grain structures of various sizes and uniform and bimodal γ′-distributions, have been investigated. The results indicate that grain size is an important microstructural parameter which can control threshold behaviour, with the value of threshold stress intensity increasing with increasing grain size, but that the γ′-distribution is also important. In this Ni-base alloy, as in many others, near threshold fatigue crack growth occurs in a crystallographic manner along {111} planes. This is due to the development of a dislocation structure involving persistent slip bands on {111} planes in the plastic zone, caused by the presence of ordered shearable precipitates in the microstructure. However, as the stress intensity range is increased, a striated growth mode takes over. The results presented show that this transition from faceted to striated growth is associated with a sudden increase in crack propagation rate and occurs when the size of the reverse plastic zone at the crack tip becomes equal to the grain size, independent of any other microstructural variables.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experiments were conducted in annealed iridium using pyramidal and spherical indenters over a wide range of load. For a Berkovich pyramidal indenter, the hardness increased with decreasing depth of penetration. However, for spherical indenters, hardness increased with decreasing sphere radius. Based on the number of geometrically necessary dislocations generated during indentation, a theory that takes into account the work hardening differences between pyramidal and spherical indenters is developed to correlate the indentation size effects measured with the two indenters. The experimental results verify the theoretical correlation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A newly released commercial autorefractor, the Shin-Nippon SRW-5000 (Japan), has been found to be valid compared to subjective refraction and repeatable over a wide prescription range. Its binocular open field-of-view allows the accommodative state to be monitored while a natural environment is viewed. In conventional static mode, the device can take up to 45 readings in 1min using digital image analysis of the reflected retinal image of a measurement ring. Continuous on-line analysis of the ring provides high (up to 60Hz) temporal resolution of the refractive state to an accuracy of <0.001D. Pupil size can also be analysed to a resolution of <0.001mm. The measurement of accommodation and pupil size was relatively unaffected by eccentricity of viewing up to ±10° and instrument focusing inaccuracies of ±5mm. The resolution properties of the analysis are shown to be ideal for measurement of dynamic accommodation and pupil responses. Copyright © 2001 The College of Optometrists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of reducing the number of visual acuity measurements made in a defocus curve on the quality of data quantified. Setting: Midland Eye, Solihull, United Kingdom. Design: Evaluation of a technique. Methods: Defocus curves were constructed by measuring visual acuity on a distance logMAR letter chart, randomizing the test letters between lens presentations. The lens powers evaluated ranged between +1.50 diopters (D) and -5.00 D in 0.50 D steps, which were also presented in a randomized order. Defocus curves were measured binocularly with the Tecnis diffractive, Rezoom refractive, Lentis rotationally asymmetric segmented (+3.00 D addition [add]), and Finevision trifocal multifocal intraocular lenses (IOLs) implanted bilaterally, and also for the diffractive IOL and refractive or rotationally asymmetric segmented (+3.00 D and +1.50 D adds) multifocal IOLs implanted contralaterally. Relative and absolute range of clear-focus metrics and area metrics were calculated for curves fitted using 0.50 D, 1.00 D, and 1.50 D steps and a near add-specific profile (ie, distance, half the near add, and the full near-add powers). Results: A significant difference in simulated results was found in at least 1 of the relative or absolute range of clear-focus or area metrics for each of the multifocal designs examined when the defocus-curve step size was increased (P<.05). Conclusion: Faster methods of capturing defocus curves from multifocal IOL designs appear to distort the metric results and are therefore not valid. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2013 ASCRS and ESCRS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of our research in the first half of 2011 was to find out what were the administrative, regulative and other problems that were specific obstacles to local economic development and what best practices can be found in local economies. During our research we carried out interviews with leaders and local professionals in five medium size towns of Hungary. We stated that the most obstructive factors were the imperfection of vocational training, the excessively bureaucratic administrative proceedings (supplying of data, acquisition of authority permits, the attitude of the authorities, etc.) and the system of application and finding sources of funds. We think that the most innovative solutions are the good examples of the institutionalized co-operation between local governments and local businesses. We've come to the conclusion that there is a need for reducing administrative burdens for the sake of local economic development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the introduction of fiber reinforced polymers (FRP) for the repair and retrofit of concrete structures in the 1980’s, considerable research has been devoted to the feasibility of their application and predictive modeling of their performance. However, the effects of flaws present in the constitutive components and the practices in substrate preparation and treatment have not yet been thoroughly studied. This research aims at investigating the effect of surface preparation and treatment for the pre-cured FRP systems and the groove size tolerance for near surface mounted (NSM) FRP systems; and to set thresholds for guaranteed system performance. This study was conducted as part of the National Cooperative Highway Research Program (NCHRP) Project 10-59B to develop construction specifications and process control manual for repair and retrofit of concrete structures using bonded FRP systems. The research included both analytical and experimental components. The experimental program for the pre-cured FRP systems consisted of a total of twenty-four (24) reinforced concrete (RC) T-beams with various surface preparation parameters and surface flaws, including roughness, flatness, voids and cracks (cuts). For the NSM FRP systems, a total of twelve (12) additional RC T-beams were tested with different grooves sizes for FRP bars and strips. The analytical program included developing an elaborate nonlinear finite element model using the general purpose software ANSYS. The bond interface between FRP and concrete was modeled by a series of nonlinear springs. The model was validated against test data from the present study as well as those available from the literature. The model was subsequently used to extend the experimental range of parameters for surface flatness in pre-cured FRP systems and for groove size study in the NSM FRP systems. Test results, confirmed by further analyses, indicated that contrary to the general belief in the industry, the impact of surface roughness on the global performance of pre-cured FRP systems was negligible. The study also verified that threshold limits set for wet lay-up FRP systems can be extended to pre-cured systems. The study showed that larger surface voids and cracks (cuts) can adversely impact both the strength and ductility of pre-cured FRP systems. On the other hand, frequency (or spacing) of surface cracks (cuts) may only affect system ductility rather than its strength. Finally, within the range studied, groove size tolerance of ±1/8 in. does not appear to have an adverse effect on the performance of NSM FRP systems.