999 resultados para Respiratory parameters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). METHODS: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. RESULTS: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. CONCLUSION: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECT: To study a scan protocol for coronary magnetic resonance angiography based on multiple breath-holds featuring 1D motion compensation and to compare the resulting image quality to a navigator-gated free-breathing acquisition. Image reconstruction was performed using L1 regularized iterative SENSE. MATERIALS AND METHODS: The effects of respiratory motion on the Cartesian sampling scheme were minimized by performing data acquisition in multiple breath-holds. During the scan, repetitive readouts through a k-space center were used to detect and correct the respiratory displacement of the heart by exploiting the self-navigation principle in image reconstruction. In vivo experiments were performed in nine healthy volunteers and the resulting image quality was compared to a navigator-gated reference in terms of vessel length and sharpness. RESULTS: Acquisition in breath-hold is an effective method to reduce the scan time by more than 30 % compared to the navigator-gated reference. Although an equivalent mean image quality with respect to the reference was achieved with the proposed method, the 1D motion compensation did not work equally well in all cases. CONCLUSION: In general, the image quality scaled with the robustness of the motion compensation. Nevertheless, the featured setup provides a positive basis for future extension with more advanced motion compensation methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Because it decreases intubation rate and mortality, NIV has become first-line treatment in case of hypercapnic respiratory failure (HRF). Whether this approach is equally successful for all categories of HRF patients is however debated. We assessed if any clinical characteristics of HRF patients were associated with NIV intensity, success, and outcome, in order to identify prognostic factors. Methods: Retrospective analysis of the clinical database (clinical information system and MDSi) of patients consecutively admitted to our medico-surgical ICU, presenting with HRF (defined as PaCO2 >50 mm Hg), and receiving NIV between January 2009 and December 2010. Demographic data, medical diagnoses (including documented chronic lung disease), reason for ICU hospitalization, recent surgical interventions, SAPS II and McCabe scores were extracted from the database. Total duration of NIV and the need for tracheal intubation during the 5 days following the first hypercapnia documentation, as well as ICU and hospital mortality were recorded. Results are reported as median [IQR]. Comparisons with Chi2 or Kruskal-Wallis tests, p <0.05 (*). Results: 164 patients were included, 45 (27.4%) of whom were intubated after 10 [2-34] hours, after having received 7 [2-19] hours of NIV. NIV successful patients received 15 [5-22] hours of NIV for up to 5 days. Intubation was correlated with increased ICU (20% vs. 3%, p <0.001) and hospital (46.7% vs. 30.2, p >0.05) mortality. Conclusions: A majority of patients requiring NIV for hypercapnic respiratory failure in our ICU have no diagnosed chronic pulmonary disease. These patients tend to have increased ICUand hospital mortality. The majority of patients were non-surgical, a feature correlated with increased hospital mortality. Beside usual predictors of severity such as age and SAPS II, absence of diagnosed chronic pulmonary disease and non-operative state appear to be associated with increased mortality. Further studies should explore whether these patients are indeed more prone to an adverse outcome and which therapeutic strategies might contribute to alter this course.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PRINCIPLES: Respiratory care is universally recognised as useful, but its indications and practice vary markedly. In order to improve the appropriateness of respiratory care in our hospital, we developed evidence-based local guidelines in a collaborative effort involving physiotherapists, physicians and health service researchers. METHODS: Recommendations were developed using the standardised RAND appropriateness method. A literature search was conducted based on terms associated with guidelines and with respiratory care. A working group prepared proposals for recommendations which were then independently rated by a multidisciplinary expert panel. All recommendations were then discussed in common and indications for procedures were rated confidentially a second time by the experts. The recommendations were then formulated on the basis of the level of evidence in the literature and on the consensus among these experts. RESULTS: Recommendations were formulated for the following procedures: non-invasive ventilation, continuous positive airway pressure, intermittent positive pressure breathing, intrapulmonary percussive ventilation, mechanical insufflation-exsufflation, incentive spirometry, positive expiratory pressure, nasotracheal suctioning and non-instrumental airway clearance techniques. Each recommendation referred to a particular medical condition and was assigned to a hierarchical category based on the quality of the evidence from the literature supporting the recommendation and on the consensus among the experts. CONCLUSION: Despite a marked heterogeneity of scientific evidence, the method used allowed us to develop commonly agreed local guidelines for respiratory care. In addition, this work fostered a closer relationship between physiotherapists and physicians in our institution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the standard kernel density estimate, it is known that one can tune the bandwidth such that the expected L1 error is within a constant factor of the optimal L1 error (obtained when one is allowed to choose the bandwidth with knowledge of the density). In this paper, we pose the same problem for variable bandwidth kernel estimates where the bandwidths are allowed to depend upon the location. We show in particular that for positive kernels on the real line, for any data-based bandwidth, there exists a densityfor which the ratio of expected L1 error over optimal L1 error tends to infinity. Thus, the problem of tuning the variable bandwidth in an optimal manner is ``too hard''. Moreover, from the class of counterexamples exhibited in the paper, it appears thatplacing conditions on the densities (monotonicity, convexity, smoothness) does not help.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The species Sitobion graminis Takahashi, 1950 (Hemiptera, Aphididae) was first detected in Brazil in 1998, in Curitiba, Paraná state, associated with the grass species Erianthus sp., Calamagrotis sp. and Paspalum urvilei. Both the field-collected and laboratory-reared specimens presented a noticeable intrapopulational variation in body and appendix length and in dorso-abdominal sclerotization. This species has been recorded in Malaysia, New Guinea, India, Philippines and Africa, where it colonizes several species of Poaceae. S. graminis differs from other Sitobion species from Brazil associated with grasses, as it presents black cauda and siphunculi and exhibits a constriction in the base of the last rostral segment. Biological data were obtained in the laboratory by rearing newborn nymphs on the inflorescence of the host plants. They passed through four nymphal instars. The mean duration of the nymphal stage was of 11.4 days, with a mortality ratio of 36.5%. The mean pre-larviposition period was of 1.8 days; mean longevity of the females was 25.2 days; and mean fecundity was 18.7 nymphs/female, ranging from 2 to 41 nymphs/female.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Triggering receptor expressed on myeloid cells-1 (TREM-1) was reported to be up-regulated in various inflammatory diseases as well as in bacterial sepsis. Increased cell-surface TREM-1 expression was also shown to result in marked plasma elevation of the soluble form of this molecule (sTREM-1) in patients with bacterial infections. In this study, we investigated sTREM-1, procalcitonin and C-reactive protein in postmortem serum in a series of sepsis-related fatalities and control individuals who underwent medico-legal investigations. sTREM-1 was also measured in pericardial fluid and urine. METHODS: Two study groups were prospectively formed, a sepsis-related fatalities group and a control group. The sepsis-related fatalities group consisted of sixteen forensic autopsy cases. Eight of these had a documented clinical diagnosis of sepsis in vivo. The control group consisted of sixteen forensic autopsy cases with various causes of death. RESULTS: Postmortem serum sTREM-1 concentrations were higher in the sepsis group with a mean value of 173.6 pg/ml in septic cases and 79.2 pg/ml in control individuals. The cutoff value of 90 pg/ml provided the best sensitivity and specificity. Pericardial fluid sTREM-1 values were higher in the septic group, with a mean value of 296.7 pg/ml in septic cases and 100.9 pg/ml in control individuals. The cutoff value of 135 pg/ml provided the best sensitivity and specificity. Mean urine sTREM-1 concentration was 102.9 pg/ml in septic cases and 89.3 pg/ml in control individuals. CONCLUSIONS: Postmortem serum sTREM-1, individually considered, did not provide better sensitivity and specificity than procalcitonin in detecting sepsis. However, simultaneous assessment of procalcitonin and sTREM-1 in postmortem serum can be of help in clarifying contradictory postmortem findings. sTREM-1 determination in pericardial fluid can be an alternative to postmortem serum in those situations in which biochemical analyses are required and blood collected during autopsy proves insufficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the means and the reference intervals of the quantitative morphometric parameters of femoroacetabular impingement (FAI) in normal hips with high-resolution computed tomography (CT). METHODS: We prospectively included 94 adult individuals who underwent CT for thoracic, abdominal or urologic pathologies. Patients with a clinical history of hip pathology and/or with osteoarthritis on CT were excluded. We calculated means and 95 % reference intervals for imaging signs of cam-type (alpha angle at 90° and 45° and femoral head-neck offset) and pincer-type impingement (acetabular version angle, lateral centre-edge angle and acetabular index). RESULTS: The 95 % reference interval limits were all far beyond the abnormal thresholds found in the literature for cam-type and to a lesser extent for pincer-type FAI. The upper limits of the reference intervals for the alpha angles (at 90°/45°) were 68°/83° (men) and 69°/84° (women), compared to thresholds from the literature (50°, 55° or 60°). Reference intervals were similar between genders for cam-type parameters, and slightly differed for pincer-type. CONCLUSION: The 95 % reference intervals of morphometric measurements of FAI in asymptomatic hips were beyond the abnormal thresholds, which was especially true for cam-type FAI. Our results suggest the need for redefining the current morphometric parameters used in the diagnosis of FAI. KEY POINTS: ? 95 % reference intervals limits of FAI morphotype were beyond currently defined thresholds. ? Reference intervals of pincer-type morphotype measurements were close to current definitions. ? Reference intervals of cam-type morphotype measurements were far beyond the current definitions. ? Current morphometric definitions of cam-type morphotype should be used with care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Questionnaire studies indicate that high-anxious musicians may suffer from hyperventilation symptoms before and/or during performance. Reported symptoms include amongst others shortness of breath, fast or deep breathing, dizziness and thumping heart. However, no study has yet tested if these self-reported symptoms reflect actual cardio respiratory changes. Disturbances in breathing patterns and hyperventilation may contribute to the often observed poorer performance of anxious musicians under stressful performance situations. The main goal of this study is to determine if music performance anxiety is manifest physiologically in specific correlates of cardio respiratory activity. We studied 74 professional music students divided into two groups (i.e. high-anxious and lowanxious) based on their self-reported performance anxiety in three distinct situations: baseline, private performance (without audience), public performance (with audience). We measured a) breathing patterns, end-tidal carbon dioxide (EtCO2, a good non-invasive estimator for hyperventilation), ECG and b) self-perceived emotions and self-perceived physiological activation. The poster will concentrate on the preliminary results of this study. The focus will be a) on differences between high-anxious and low-anxious musicians regarding breaths per minute and heart rate and b) on the response coherence between self-perceived palpitations and actual heart rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most methods for small-area estimation are based on composite estimators derived from design- or model-based methods. A composite estimator is a linear combination of a direct and an indirect estimator with weights that usually depend on unknown parameters which need to be estimated. Although model-based small-area estimators are usually based on random-effects models, the assumption of fixed effects is at face value more appropriate.Model-based estimators are justified by the assumption of random (interchangeable) area effects; in practice, however, areas are not interchangeable. In the present paper we empirically assess the quality of several small-area estimators in the setting in which the area effects are treated as fixed. We consider two settings: one that draws samples from a theoretical population, and another that draws samples from an empirical population of a labor force register maintained by the National Institute of Social Security (NISS) of Catalonia. We distinguish two types of composite estimators: a) those that use weights that involve area specific estimates of bias and variance; and, b) those that use weights that involve a common variance and a common squared bias estimate for all the areas. We assess their precision and discuss alternatives to optimizing composite estimation in applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The jointly voluntary and involuntary control of respiration, unique among essential physiological processes, the interconnection of breathing with and its influence on the autonomic nervous system, and disease states associated with the interface between psychology and respiration (e.g., anxiety disorders, hyperventilation syndrome, asthma) make the study of the relationship between respiration and emotion both theoretically and clinically of great relevance. However, the respiratory behavior during affective states is not yet completely understood. We studied breathing pattern responses to 13 picture series varying widely in their affective tone in 37 adults (18 men, 19 women, mean age 26). Time and volume parameters were recorded with the LifeShirt system (VivoMetrics Inc., Ventura, California, USA, see image). We also measured end-tidal pCO2 (EtCO2) with a Microcap Handheld Capnograph (Oridion Medical 1987 Ltd., Jerusalem, Israel) to determine if ventilation is in balance with metabolic demands and spontaneous eye-blinking to investigate the link between respiration and attention. At the end of each picture series, the participants reported their subjective feeling in the affective dimensions of pleasantness and arousal. Increasing self-rated arousal was associated with increasing minute ventilation but not with decreases in EtCO2, suggesting that ventilatory changes during picture viewing paralleled variations in metabolic activity. EtCO2 correlated with pleasantness, and eye-blink rate decreased with increasing unpleasantness in line with a negativity bias in attention. Like MV, inspiratory drive (i.e., mean inspiratory flow) increased with arousal. This relationship reflected increases in inspiratory volume rather than shortening of the time parameters. This study confirms that respiratory responses to affective stimuli are organized to a certain degree along the dimensions of pleasantness and arousal. It shows, for the first time, that during picture viewing, ventilatory increases with increasing arousal are in balance with metabolic activity and that inspiratory volume is modulated by arousal. MV emerges as the most reliable respiratory index of self-perceived arousal. Finally, end-tidal pCO2 is slightly lower during processing of negative as compared to positive picture contents, which is proposed to enhance sensory perception and reflect a negativity bias in attention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During free walking, gait is automatically adjusted to provide optimal mechanical output and minimal energy expenditure; gait parameters, such as cadence, fluctuate from one stride to the next around average values. It was described that this fluctuation exhibited long-range correlations and fractal-like patterns. In addition, it was suggested that these long-range correlations disappeared if the participant followed the beep of metronome to regulate his or her pace. Until now, these fractal fluctuations were only observed for stride interval, because no technique existed to adequately analyze an extended time of free walking. The aim of the present study was to measure walking speed (WS), step frequency (SF) and step length (SL) with high accuracy (<1 cm) satellite positioning method (global positioning system or GPS) in order to detect long-range correlations in the stride-to-stride fluctuations. Eight participants walked 30 min under free and constrained (metronome) conditions. Under free walking conditions, DFA (detrended fluctuation analysis) and surrogate data tests showed that the fluctuation of WS, SL and SF exhibited a fractal pattern (i.e., scaling exponent alpha: 0.5 < alpha < 1) in a large majority of participants (7/8). Under constrained conditions (metronome), SF fluctuations became significantly anti-correlated (alpha < 0.5) in all participants. However, the scaling exponent of SL and WS was not modified. We conclude that, when the walking pace is controlled by an auditory signal, the feedback loop between the planned movement (at supraspinal level) and the sensory inputs induces a continual shifting of SF around the mean (persistent anti-correlation), but with no effect on the fluctuation dynamics of the other parameters (SL, WS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many dynamic revenue management models divide the sale period into a finite number of periods T and assume, invoking a fine-enough grid of time, that each period sees at most one booking request. These Poisson-type assumptions restrict the variability of the demand in the model, but researchers and practitioners were willing to overlook this for the benefit of tractability of the models. In this paper, we criticize this model from another angle. Estimating the discrete finite-period model poses problems of indeterminacy and non-robustness: Arbitrarily fixing T leads to arbitrary control values and on the other hand estimating T from data adds an additional layer of indeterminacy. To counter this, we first propose an alternate finite-population model that avoids this problem of fixing T and allows a wider range of demand distributions, while retaining the useful marginal-value properties of the finite-period model. The finite-population model still requires jointly estimating market size and the parameters of the customer purchase model without observing no-purchases. Estimation of market-size when no-purchases are unobservable has rarely been attempted in the marketing or revenue management literature. Indeed, we point out that it is akin to the classical statistical problem of estimating the parameters of a binomial distribution with unknown population size and success probability, and hence likely to be challenging. However, when the purchase probabilities are given by a functional form such as a multinomial-logit model, we propose an estimation heuristic that exploits the specification of the functional form, the variety of the offer sets in a typical RM setting, and qualitative knowledge of arrival rates. Finally we perform simulations to show that the estimator is very promising in obtaining unbiased estimates of population size and the model parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biotic potential and reprodutcive parameters of Spodoptera eridania (Stoll) (Lepidoptera, Noctuidae) in the laboratory: This study aimed to evaluate the biotic potential and reproductive parameters of Spodoptera eridania (Stoll, 1782) under controlled conditions (25 ± 1ºC, 70 ± 10% RH and 14 hour photophase). The longevity, pre-, post- and oviposition periods, fecundity and fertility of 15 couples was evaluated. The longevity of females (10.80 days) was not significantly higher than those of males (9.27 days). The mean durations of the pre, post and oviposition periods were 2.067, 0.600 and 8.133 days, respectively. The mean fecundity per female was 1,398 eggs and the mean fertility was 1,367.50 larvae. On average, females copulated 1.133 times. A strong positive correlation was observed between the number of mating and fecundity (r = 0.881, P <0.001). However a strong negative correlation was observed between the number of copulations and the duration of the pre-oviposition period (r = -0.826, P = 0.002) and longevity (r = -0.823, P = 0.001). The biotic potential of S. eridania was estimated at 1.894 x 10(25) individuals/female/year. The net reproductive rate (Ro) was 560.531 times per generation and the mean generation time (T) was 35.807 days. The intrinsic rate of increase (rm) was 0.177, with a finite rate of increase (l) of 1.193, per week

Relevância:

20.00% 20.00%

Publicador:

Resumo:

T O THE E DITOR-Besides viruses, Mycoplasma pneumoniae and Chlamydia pneumoniae are common causes of community-acquired respiratory infections (CARI) in children. However, the causal agent of CARI remains unknown in many cases [ 1]. Growing evidence suggests that Chlamydia-related bacteria might have a pathogenic role in humans [ 2, 3]. Parachlamydia acanthamoebae and Protochlamydia naegleriophila have been detected in respiratory clinical samples [ 4, 5], and the role of Parachlamydia acanthamoebae in pneumonia is supported by in vitro studies and animal models [ 6]. Rhabdochlamydia crassificans and Rhabdochlamydia porcellionis are intracellular pathogens of arthropods that also belong to the Chlamydiales order [ 7, 8]. A recent analysis suggests that Rhabdochlamydia species might affect morbidity and mortality in premature newborns [ 9], but their role ...