951 resultados para Reproducibility
Resumo:
Purpose: To evaluate inter- and intraobserver variability of indices crucial for detection of keratoconus progression derived from the Pentacam HR® (high-resolution) tomographer (OCULUS Optikgeräte GmbH, Wetzlar, Germany) in patients with mild to moderate keratoconus. Methods: Three repeated corneal topography measurements in the 25-picture mode by two independent observers were performed. The extent of variability across a large range of measurement parameters was analyzed including anterior and posterior corneal surface measurements, pachymetry values, corneal volume, anterior chamber volume and depth, and iridocorneal angle. The intraclass correlation coefficient (ICC) between and within each investigator was calculated to assess reproducibility and repeatability, respectively. Results: 31 eyes of 20 patients (mean age 31.6, SD ± 8.6) were included. Overall, the repeatability and reproducibility were excellent. The range of variability was reported by calculating the standard deviation of measurements. The detailed results are shown in Table 1. Conclusions: This study shows that the Pentacam HR® tomographer provides reliable measurements in patients with mild to moderate keratoconus. However, all parameters showed a certain range of variability. This should be taken into account when assessing keratoconus progression in order to distinguish true progression from variability in measurements. In addition, the excellent reproducibility suggests that the measurements can be reliably performed by different individuals from one visit to another.
Resumo:
The aim of this work is to present a new concept, called on-line desorption of dried blood spots (on-line DBS), allowing the direct analysis of a dried blood spot coupled to liquid chromatography mass spectrometry device (LC/MS). The system is based on an inox cell which can receive a blood sample (10 microL) previously spotted on a filter paper. The cell is then integrated into LC/MS system where the analytes are desorbed out of the paper towards a column switching system ensuring the purification and separation of the compounds before their detection on a single quadrupole MS coupled to atmospheric pressure chemical ionisation (APCI) source. The described procedure implies that no pretreatment is necessary in spite the analysis is based on whole blood sample. To ensure the applicability of the concept, saquinavir, imipramine, and verapamil were chosen. Despite the use of a small sampling volume and a single quadrupole detector, on-line DBS allowed the analyses of these three compounds over their therapeutic concentrations from 50 to 500 ng/mL for imipramine and verapamil and from 100 to 1000 ng/mL for saquinavir. Moreover, the method showed good repeatability with relative standard deviation (RSD) lower than 15% based on two levels of concentration (low and high). Function responses were found to be linear over the therapeutic concentration for each compound and were used to determine the concentrations of real patient samples for saquinavir. Comparison of the founded values with those of a validated method used routinely in a reference laboratory showed a good correlation between the two methods. Moreover, good selectivity was observed ensuring that no endogenous or chemical components interfered with the quantitation of the analytes. This work demonstrates the feasibility and applicability of the on-line DBS procedure for bioanalysis.
Resumo:
OBJECTIVES: The purpose of this study was to assess the effectiveness of a novel radiation-independent aiming device for distal locking of intramedullary nails in a human cadaver model. METHODS: A new targeting system was used in 25 intact human cadaver femora for the distal locking procedure after insertion of an intramedullary nail. The number of successful screw placements and the time needed for this locking procedure were recorded. The accuracy of the aiming process was evaluated by computed tomography. RESULTS: The duration of the distal locking process was 8.0 ± 1.8 minutes (mean ± SD; range, 4-11 minutes). None of the screw placements required fluoroscopic guidance. Computed tomography revealed high accuracy of the locking process. The incidence angle (α) of the locking screws through the distal locking holes of the nail was 86.8° ± 5.0° (mean ± SD; range, 80°-96°). Targeting failed in 1 static locking screw because of a material defect in the drilling sleeve. CONCLUSIONS: This cadaver study indicated that an aiming arm-based targeting device is highly reliable and accurate. The promising results suggest that it will help to decrease radiation exposure compared with the traditional "free-hand technique."
Resumo:
In this investigation, high-resolution, 1x1x1-mm(3) functional magnetic resonance imaging (fMRI) at 7 T is performed using a multichannel array head coil and a surface coil approach. Scan geometry was optimized for each coil separately to exploit the strengths of both coils. Acquisitions with the surface coil focused on partial brain coverage, while whole-brain coverage fMRI experiments were performed with the array head coil. BOLD sensitivity in the occipital lobe was found to be higher with the surface coil than with the head array, suggesting that restriction of signal detection to the area of interest may be beneficial for localized activation studies. Performing independent component analysis (ICA) decomposition of the fMRI data, we consistently detected BOLD signal changes and resting state networks. In the surface coil data, a small negative BOLD response could be detected in these resting state network areas. Also in the data acquired with the surface coil, two distinct components of the positive BOLD signal were consistently observed. These two components were tentatively assigned to tissue and venous signal changes.
Resumo:
The objectives of this study were to develop a computerized method to screen for potentially avoidable hospital readmissions using routinely collected data and a prediction model to adjust rates for case mix. We studied hospital information system data of a random sample of 3,474 inpatients discharged alive in 1997 from a university hospital and medical records of those (1,115) readmitted within 1 year. The gold standard was set on the basis of the hospital data and medical records: all readmissions were classified as foreseen readmissions, unforeseen readmissions for a new affection, or unforeseen readmissions for a previously known affection. The latter category was submitted to a systematic medical record review to identify the main cause of readmission. Potentially avoidable readmissions were defined as a subgroup of unforeseen readmissions for a previously known affection occurring within an appropriate interval, set to maximize the chance of detecting avoidable readmissions. The computerized screening algorithm was strictly based on routine statistics: diagnosis and procedures coding and admission mode. The prediction was based on a Poisson regression model. There were 454 (13.1%) unforeseen readmissions for a previously known affection within 1 year. Fifty-nine readmissions (1.7%) were judged avoidable, most of them occurring within 1 month, which was the interval used to define potentially avoidable readmissions (n = 174, 5.0%). The intra-sample sensitivity and specificity of the screening algorithm both reached approximately 96%. Higher risk for potentially avoidable readmission was associated with previous hospitalizations, high comorbidity index, and long length of stay; lower risk was associated with surgery and delivery. The model offers satisfactory predictive performance and a good medical plausibility. The proposed measure could be used as an indicator of inpatient care outcome. However, the instrument should be validated using other sets of data from various hospitals.
Resumo:
OBJECTIVE: to assess the levels and determinants of interleukin (IL)-1ß, IL-6, tumour necrosis factor (TNF)-a and C-reactive protein (CRP) in a healthy Caucasian population.METHODS: population sample of 2884 men and 3201 women aged 35 to 75. IL-1ß, IL-6 and TNF-a were assessed by a multiplexed particle-based flow cytometric assay and CRP by an immunometric assay.RESULTS: Spearman rank correlations between duplicate cytokine measurements (N?=?80) ranged between 0.89 and 0.96; intra-class correlation coefficients ranged between 0.94 and 0.97, indicating good reproducibility. Among the 6085 participants, 2289 (37.6%), 451 (7.4%) and 43 (0.7%) had IL-1ß, IL-6 and TNF-a levels below detection limits, respectively. Median (interquartile range) for participants with detectable values were 1.17 (0.48-3.90) pg/ml for IL-1ß; 1.47 (0.71-3.53) pg/ml for IL-6; 2.89 (1.82-4.53) pg/ml for TNF-a and 1.3 (0.6-2.7) ng/ml for CRP. On multivariate analysis, greater age was the only factor inversely associated with IL-1ß levels. Male sex, increased BMI and smoking were associated with greater IL-6 levels, while no relationship was found for age and leisure-time PA. Male sex, greater age, increased BMI and current smoking were associated with greater TNF-a levels, while no relationship was found with leisure-time PA. CRP levels were positively related to age, BMI and smoking, and inversely to male sex and physical activity.CONCLUSION: Population-based levels of several cytokines were established. Increased age and BMI, and to a lesser degree sex and smoking, significantly and differentially impact cytokine levels, while leisure-time physical activity has little effect.
Resumo:
OBJECTIVE: Imaging during a period of minimal myocardial motion is of paramount importance for coronary MR angiography (MRA). The objective of our study was to evaluate the utility of FREEZE, a custom-built automated tool for the identification of the period of minimal myocardial motion, in both a moving phantom at 1.5 T and 10 healthy adults (nine men, one woman; mean age, 24.9 years; age range, 21-32 years) at 3 T. CONCLUSION: Quantitative analysis of the moving phantom showed that dimension measurements approached those obtained in the static phantom when using FREEZE. In vitro, vessel sharpness, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were significantly improved when coronary MRA was performed during the software-prescribed period of minimal myocardial motion (p < 0.05). Consistent with these objective findings, image quality assessments by consensus review also improved significantly when using the automated prescription of the period of minimal myocardial motion. The use of FREEZE improves image quality of coronary MRA. Simultaneously, operator dependence can be minimized while the ease of use is improved.
Resumo:
OBJECTIVES: To evaluate the combination of ultrasound (US) + fine-needle aspiration (FNA) in the assessment of salivary gland tumours in the hands of the otolaryngologist. DESIGN: A retrospective review of case notes was performed. SETTING: Two university teaching hospitals in Switzerland. PARTICIPANTS: One hundred and three patients with a total of 106 focal masses of the salivary glands were included. Clinician-operated US + FNA were the first line of investigation for these lesions. All patients underwent surgical excision of the lesion, which allowed for confirmation of diagnosis by histopathology in 104 lesions and by laboratory testing in two lesions. MAIN OUTCOME MEASURES: Primary--diagnostic accuracy in identifying true salivary gland neoplasms and detecting malignancy. Secondary--predicting an approximate and specific diagnosis in these tumours. RESULTS: The combination of US + FNA achieved a diagnostic accuracy of 99% in identifying and differentiating true salivary gland neoplasms from tumour-like lesions. In detecting malignancy, this combination permitted an accuracy of 98%. An approximate diagnosis was possible in 89%, and a specific diagnosis in 69% of our patients. CONCLUSIONS: Due to economic factors and a high diagnostic accuracy, the combination of US + FNA represents the investigation method of choice for most salivary gland tumours. We suggest that the otolaryngologist be employed in carrying out these procedures, as is already the rule in other medical specialties, while computed tomography and magnetic resonance imaging should be reserved to those few lesions, which cannot be delineated completely by sonography.
Resumo:
Despite obvious improvements in spectral resolution at high magnetic field, the detection of 13C labeling by 1H-[13C] NMR spectroscopy remains hampered by spectral overlap, such as in the spectral region of 1H resonances bound to C3 of glutamate (Glu) and glutamine (Gln), and C6 of N-acetylaspartate (NAA). The aim of this study was to develop, implement, and apply a novel 1H-[13C] NMR spectroscopic editing scheme, dubbed "selective Resonance suppression by Adiabatic Carbon Editing and Decoupling single-voxel STimulated Echo Acquisition Mode" (RACED-STEAM). The sequence is based on the application of two asymmetric narrow-transition-band adiabatic RF inversion pulses at the resonance frequency of the 13C coupled to the protons that need to be suppressed during the mixing time (TM) period, alternating the inversion band downfield and upfield from the 13C resonance on odd and even scans, respectively, thus suppressing the detection of 1H resonances bound to 13C within the transition band of the inversion pulse. The results demonstrate the efficient suppression of 1H resonances bound to C3 of Glu and Gln, and C4 of Glu, which allows the 1H resonances bound to C6 of NAA and C4 of Gln to be revealed. The measured time course of the resolved labeling into NAA C6 with the new scheme was consistent with the slow turnover of NAA.
Resumo:
The value of various indexes to characterize the stimulus-response curve of human motor nerves was assessed in 40 healthy subjects recruited from four European centers of investigation (Créteil, Lausanne, Liège, Marseille). Stimulus-response curves were established by stimulating the right median and ulnar motor nerves at the wrist, with stimulus durations of 0.05 and 0.5 ms. The following parameters were studied: the threshold intensity of stimulation to obtain 10% (I 10), 50% (I 50), and 90% (I 90) of the maximal compound muscle action potential, the ratios I 10/I 50, I 90/I 50, (I 90 - I 10)/I 10, (I 90-I 50)/I 50, and (I 50 - I 10)/I 10, and the slopes of the stimulus-response curves with or without normalization to I 50. For each parameter, within-center variability and reproducibility (in a test-retest study) were assessed and between-center comparisons were made. For most of the parameters, the results varied significantly within and between the centers. Within the centers, only the ratios I 10/I 50 and I 90/I 50 were found constant and reproducible. Between the centers, the absolute intensity thresholds (I 10, I 50, I 90) and the ratio I 90/I 50 did not show significant differences at stimulus duration of 0.5 ms, whatever the stimulated nerve. The reduced variability and good reproducibility of the ratios I 10/I 50 and I 90/I 50 open perspectives in neurophysiological practice for the use of these indexes of the stimulus-response curve, a rapid and noninvasive test.
Resumo:
The Hi·Art II Helical TomoTherapy (HT) unit is equipped with a built-in onboard MVCT detector used for patient imaging and beam monitoring. Our aim was to study the detector stability for treatment beam measurements. We studied the MVCT detector response with the 6 MV photon beam over time, throughout short-term (during an irradiation) and long-term (two times 50 days) periods. Our results show a coefficient of variation ≤ 1% for detector chambers inside the beam (excluding beam gradients) for short- and long-term response of the MVCT detector. Larger variations were observed in beam gradients and an influence of the X-ray target where degradation was found. The results assume that an 'air scan' procedure is performed daily to recalibrate the detector with the imaging beam. On short term, the detector response stability is comparable to other devices. Long-term measure- ments during two 50-day periods show a good reproducibility.
Resumo:
Late-onset cytomegalovirus (CMV) disease commonly occurs after discontinuation of antiviral prophylaxis. We determined the utility of testing CD8+ T-cell response against CMV as a predictor of late-onset CMV disease after a standard course of antiviral prophylaxis. Transplant patients at high-risk for CMV disease were enrolled. CD8+ T-cell-mediated immunity (CMI) was tested using the QuantiFERON-CMV assay at baseline, 1, 2 and 3 months posttransplant by measurement of interferon-gamma response to whole blood stimulation with a 21-peptide pool. The primary outcome was the ability of CMI testing to predict CMV disease in the first 6 months posttransplant. There were 108 evaluable patients (D+/R+ n = 39; D-/R+ n = 34; D+/R- n = 35) of whom 18 (16.7%) developed symptomatic CMV disease. At the end of prophylaxis, CMI was detectable in 38/108 (35.2%) patients (cutoff 0.1 IU/mL interferon-gamma). CMV disease occurred in 2/38 (5.3%) patients with a detectable interferon-gamma response versus 16/70 (22.9%) patients with a negative response; p = 0.038. In the subgroup of D+/R- patients, CMV disease occurred in 1/10 (10.0%) patients with a detectable interferon-gamma response (cutoff 0.1 IU/mL) versus 10/25 (40.0%) patients with a negative CMI, p = 0.12. Monitoring of CMI may be useful for predicting late-onset CMV disease.
Resumo:
Waddlia chondrophila is a strict intracellular microorganism belonging to the order Chlamydiales that has been isolated twice from aborted bovine fetuses, once in USA and once in Germany. This bacterium is now considered as an abortigenic agent in cattle. However, no information is available regarding the presence of this bacterium in Africa. Given the low sensitivity of cell culture to recover such an obligate intracellular bacterium, molecular-based diagnostic approaches are warranted. This report describes the development of a quantitative SYBR Green real-time PCR assay targeting the recA gene of W. chondrophila. Analytical sensitivity was 10 copies of control plasmid DNA per reaction. No cross-amplification was observed when testing pathogens that can cause abortion in cattle. The PCR exhibited a good intra-run and inter-run reproducibility. This real-time PCR was then applied to 150 vaginal swabs taken from Tunisian cows that have aborted. Twelve samples revealed to be Waddlia positive, suggesting a possible role of this bacterium in this setting. This new real-time PCR assay represents a diagnostic tool that may be used to further study the prevalence of Waddlia infection.
Resumo:
OBJECTIVE: Smuggling dissolved drugs, especially cocaine, in bottled liquids is an ongoing problem at borders. Common fluoroscopy of packages at the border cannot detect contaminated liquids. The objective of our study was to develop an MDCT screening method to detect cocaine-containing vessels that are hidden between uncontaminated ones in a shipment. MATERIALS AND METHODS: Studies were performed on three wine bottles containing cocaine solutions that were confiscated at the Swiss border. Reference values were obtained by scans of different sorts of commercially available wine and aqueous solutions of dissolved sugar. All bottles were scanned using MDCT, and data evaluation was performed by measuring the mean peak of Hounsfield units. To verify the method, simulated testing was performed. RESULTS: Using measurements of the mean peak of Hounsfield units enables the detection of dissolved cocaine in wine bottles in a noninvasive and rapid fashion. Increasing opacity corresponds well with the concentration of dissolved cocaine. Simulated testing showed that it is possible to distinguish between cocaine-contaminated and uncontaminated wine bottles. CONCLUSION: The described method is an efficacious screening method to detect cocaine-contaminated bottles that are hidden between untreated bottles in cargo. The noninvasive examination of cargo allows a questionable delivery to be tracked without arousing the suspicion of the smugglers.