883 resultados para Radiographic Image Interpretation, Computer-Assisted


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To reveal the EEG correlates of resting hypofrontality in schizophrenia (SZ). METHOD: We analyzed the whole-head EEG topography in 14 patients compared to 14 matched controls by applying a new parameterization of the multichannel EEG. We used a combination of power measures tuned for regional surface mapping with power measures that allow evaluation of global effects. RESULTS: The SZ-related EEG abnormalities include i) a global decrease in absolute EEG power robustly manifested in the alpha and beta frequency bands, and ii) a relative increase in the alpha power over the prefrontal brain regions against its reduction over the posterior regions. In the alpha band both effects are linked to the SZ symptoms measured with Positive and Negative Symptom Scales and to chronicity. CONCLUSION: As alpha activity is related to regional deactivation, our findings support the concept of hypofrontality in SZ and expose the alpha rhythm as a sensitive indicator of it.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fa uns anys un grup de professors del departament d’Informàtica i Matemàtica Aplicada de la Universitat de Girona va decidir endinsar-se al món de l’ensenyament a través d’Internet (e-learning). D’aquí va néixer el projecte ACME (Avaluació Continuada i Millora de l’Ensenyament). Inicialment l’ACME anava dirigit a reduir l’elevat fracàs dels alumnes a les assignatures de matemàtiques. El resultat va ser tan bo que es va ampliar a altrescamps d’estudi com la química o la informàtica, amb tot i això encara hi ha moltes matèries a les quals no dóna suport. Aquest Projecte Final de Carrera neix per donar suport a un nou tipus de problemes dins de la plataforma ACME, els autòmats finits. Aquest nou mòdul inclourà les eines necessàries per poder generar diferents tipus de problemes sobre autòmats finits i la seva posterior correcció, donant suport a les assignatures de LGA (Llenguatges, Gramàtiques i Autòmats) i TALLF (Teoria d’Autòmats i Llenguatges Formals)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim of the present article was to perform three-dimensional (3D) single photon emission tomography-based dosimetry in radioimmunotherapy (RIT) with (90)Y-ibritumomab-tiuxetan. A custom MATLAB-based code was used to elaborate 3D images and to compare average 3D doses to lesions and to organs at risk (OARs) with those obtained with planar (2D) dosimetry. Our 3D dosimetry procedure was validated through preliminary phantom studies using a body phantom consisting of a lung insert and six spheres with various sizes. In phantom study, the accuracy of dose determination of our imaging protocol decreased when the object volume decreased below 5 mL, approximately. The poorest results were obtained for the 2.58 mL and 1.30 mL spheres where the dose error evaluated on corrected images with regard to the theoretical dose value was -12.97% and -18.69%, respectively. Our 3D dosimetry protocol was subsequently applied on four patients before RIT with (90)Y-ibritumomab-tiuxetan for a total of 5 lesions and 4 OARs (2 livers, 2 spleens). In patient study, without the implementation of volume recovery technique, tumor absorbed doses calculated with the voxel-based approach were systematically lower than those calculated with the planar protocol, with average underestimation of -39% (range from -13.1% to -62.7%). After volume recovery, dose differences reduce significantly, with average deviation of -14.2% (range from -38.7.4% to +3.4%, 1 overestimation, 4 underestimations). Organ dosimetry in one case overestimated, in the other underestimated the dose delivered to liver and spleen. However, both for 2D and 3D approach, absorbed doses to organs per unit administered activity are comparable with most recent literature findings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accurate perception of the order of occurrence of sensory information is critical for the building up of coherent representations of the external world from ongoing flows of sensory inputs. While some psychophysical evidence reports that performance on temporal perception can improve, the underlying neural mechanisms remain unresolved. Using electrical neuroimaging analyses of auditory evoked potentials (AEPs), we identified the brain dynamics and mechanism supporting improvements in auditory temporal order judgment (TOJ) during the course of the first vs. latter half of the experiment. Training-induced changes in brain activity were first evident 43-76 ms post stimulus onset and followed from topographic, rather than pure strength, AEP modulations. Improvements in auditory TOJ accuracy thus followed from changes in the configuration of the underlying brain networks during the initial stages of sensory processing. Source estimations revealed an increase in the lateralization of initially bilateral posterior sylvian region (PSR) responses at the beginning of the experiment to left-hemisphere dominance at its end. Further supporting the critical role of left and right PSR in auditory TOJ proficiency, as the experiment progressed, responses in the left and right PSR went from being correlated to un-correlated. These collective findings provide insights on the neurophysiologic mechanism and plasticity of temporal processing of sounds and are consistent with models based on spike timing dependent plasticity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: A pregnant woman was referred for post-operative radiotherapy of a malignant schwannoma in the head and neck region. A best-treatment plan was devised in order to minimize the fetal dose. MATERIAL AND METHODS: The fetal dose resulting from radiological examinations was determined according to international protocols, that resulting from radiotherapy was calculated according to Recommendation 36 of the American Association of Physicists in Medicine (AAPM) Task Group. Pre-treatment dosimetry was performed with an anthropomorphic phantom. Several alternative treatment plans were evaluated. The use of a multileaf collimator (MLC) and a virtual wedge (VW) was compared to cerrobend blocks (CB) and physical wedge (PW). In-vivo dosimetry was performed using a vaginal probe containing thermoluminescent dosimeters (TLD). RESULTS: The total fetal dose resulting from diagnostic and radiotherapy procedures was estimated to be 36 mGy. The technique based on MLC and VW was elected for patient treatment. Measurements for this configuration resulted in afetal dose reduction of 82%. The shielding of the patient's abdomen further reduced the fetal dose by 42%. CONCLUSION: The use of VW and MLC for the treatment of a pregnant woman is highly recommended. Each case should be individually studied with pre-treatment and in-vivo dosimetry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Osteoporosis is a serious worldwide epidemic. Increased risk of fractures is the hallmark of the disease and is associated with increased morbidity, mortality and economic burden. FRAX® is a web-based tool developed by the Sheffield WHO Collaborating Center team, that integrates clinical risk factors, femoral neck BMD, country specific mortality and fracture data and calculates the 10 year fracture probability in order to help health care professionals identify patients who need treatment. However, only 31 countries have a FRAX® calculator at the time paper was accepted for publication. In the absence of a FRAX® model for a particular country, it has been suggested to use a surrogate country for which the epidemiology of osteoporosis most closely approximates the index country. More specific recommendations for clinicians in these countries are not available. In North America, concerns have also been raised regarding the assumptions used to construct the US ethnic specific FRAX® calculators with respect to the correction factors applied to derive fracture probabilities in Blacks, Asians and Hispanics in comparison to Whites. In addition, questions were raised about calculating fracture risk in other ethnic groups e.g., Native Americans and First Canadians. In order to provide additional guidance to clinicians, a FRAX® International Task Force was formed to address specific questions raised by physicians in countries without FRAX® calculators and seeking to integrate FRAX® into their clinical practice. The main questions that the task force tried to answer were the following: The Task Force members conducted appropriate literature reviews and developed preliminary statements that were discussed and graded by a panel of experts at the ISCD-IOF joint conference. The statements approved by the panel of experts are discussed in the current paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The World Health Organization fracture risk assessment tool, FRAX(®), is an advance in clinical care that can assist in clinical decision-making. However, with increasing clinical utilization, numerous questions have arisen regarding how to best estimate fracture risk in an individual patient. Recognizing the need to assist clinicians in optimal use of FRAX(®), the International Osteoporosis Foundation (IOF) in conjunction with the International Society for Clinical Densitometry (ISCD) assembled an international panel of experts that ultimately developed joint Official Positions of the ISCD and IOF advising clinicians regarding FRAX(®) usage. As part of the process, the charge of the FRAX(®) Clinical Task Force was to review and synthesize data surrounding a number of recognized clinical risk factors including rheumatoid arthritis, smoking, alcohol, prior fracture, falls, bone turnover markers and glucocorticoid use. This synthesis was presented to the expert panel and constitutes the data on which the subsequent Official Positions are predicated. A summary of the Clinical Task Force composition and charge is presented here.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of virtual learning environments it’s more and more frequent in all education levels. However, this increasing use of such environments also implies that the different stages now used in the processes of teaching-learning need to be considered. Student users in a virtual learning environment are faced, not only to the problems related to acquire the knowledge of their course, but also to technological problems as information overloading, getting used to web surfing, computer use, etc. One way to minimize the impact caused by heterogeneity existing in virtual learning environments is to adapt several aspects to the specific characteristics from the user and his context. From this point of view, this work shows a model for an integral user that has been used to generate a virtual course that can interoperate between ELearning platforms. This course has been created using the SCORM reference model and the IMSLD specification

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Standards and specifícations to manage accessibility issues in e-learning

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Currently there are many standards that deal with accessibility issues regarding users’ models, learning scenarios, interaction preferences, devices capabilities, metadata for specifying the delivery of any resource to meet users’ needs, and software accessibility and usability. It is difficult to understand the existing relationships between these standards, as each one represents a different viewpoint and thus has its own sets of goals and scope. This paper gives an overview on existing standards addressing accessibility, usability and adaptation issues in e-learning, and discusses their application to cope with the objectives of the A2UN@ project, which focuses on attending the accessibility and adaptation needs for ALL in Higher Education

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In vivo localized and fully adiabatic homonuclear and heteronuclear polarization transfer experiments were designed and performed in the rat brain at 9.4 T after infusion of hyperpolarized sodium [1,2-(13)C(2)] and sodium [1-(13)C] acetate. The method presented herein leads to highly enhanced in vivo detection of short-T(1) (13)C as well as attached protons. This indirect detection scheme allows for probing additional molecular sites in hyperpolarized substrates and their metabolites and can thus lead to improved spectral resolution such as in the case of (13)C-acetate metabolism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was to evaluate the treatment dosimetry, efficacy and toxicity of intensity modulated radiation therapy (IMRT) and fractionated stereotactic radiotherapy (FSRT) in the management of infratentorial ependymoma. Between 1999 and 2007, seven children (median age, 3.1 years) with infratentorial ependymoma were planned with either IMRT (3 patients) or SFRT (4 patients), the latter after conventional posterior fossa irradiation. Two children underwent gross total resection. Median prescribed dose was 59.4 Gy (range, 55.8-60). The median follow-up for surviving patients was 4.8 years (range, 1.3-8). IMRT (median dose, 59.4 Gy) and FSRT (median dose, 55.8 Gy) achieved similar optimal target coverage. Percentages of maximum doses delivered to the cochleae (59.5 vs 85.0% Gy; P = 0.05) were significantly inferior with IMRT, when compared to FSRT planning. Percentages of maximum doses administered to the pituitary gland (38.2 vs 20.1%; P = 0.05) and optic chiasm (38.1 vs 14.1%; P = 0.001) were, however, significantly higher with IMRT, when compared to FSRT planning. No recurrences were observed at the last follow-up. The estimated 3-year progression-free survival and overall survival were 87.5 and 100%, respectively. No grade >1 acute toxicity was observed. Two patients presented late adverse events (grade 2 hypoacousia) during follow-up, without cognitive impairment. IMRT or FSRT for infratentorial ependymomas is effective and associated with a tolerable toxicity level. Both treatment techniques were able to capitalize their intrinsic conformal ability to deliver high-dose radiation. Larger series of patients treated with these two modalities will be necessary to more fully evaluate these delivery techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulse-wave velocity (PWV) is considered as the gold-standard method to assess arterial stiffness, an independent predictor of cardiovascular morbidity and mortality. Current available devices that measure PWV need to be operated by skilled medical staff, thus, reducing the potential use of PWV in the ambulatory setting. In this paper, we present a new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor. This technique relies on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum. Combined thoracic impedance cardiography and phonocardiography are used to detect the opening of the aortic valve, from which a pre-ejection period (PEP) value is estimated. Multichannel reflective photoplethysmography at the sternum is used to detect the distal pulse-arrival time (PAT). A PTT value is then calculated as PTT = PAT - PEP. After optimizing the parameters of the chest PTT calculation algorithm on a nine-subject cohort, a prospective validation study involving 31 normo- and hypertensive subjects was performed. 1/chest PTT correlated very well with the COMPLIOR carotid to femoral PWV (r = 0.88, p < 10 (-9)). Finally, an empirical method to map chest PTT values onto chest PWV values is explored.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Se presenta la adaptación de un programa de gestión de aprendizaje (Moodle) a las necesidades de gestión de una intranet administrativa. Se describen los requisitos, su estructura y se analiza su grado de utilización cuatro años después de su puesta en marcha, indicando los principales puntos débiles del sistema y las posibles aplicaciones complementarias para contrarrestarlas.