939 resultados para QUALITY study


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Respiratory motion correction remains a challenge in coronary magnetic resonance imaging (MRI) and current techniques, such as navigator gating, suffer from sub-optimal scan efficiency and ease-of-use. To overcome these limitations, an image-based self-navigation technique is proposed that uses "sub-images" and compressed sensing (CS) to obtain translational motion correction in 2D. The method was preliminarily implemented as a 2D technique and tested for feasibility for targeted coronary imaging. METHODS: During a 2D segmented radial k-space data acquisition, heavily undersampled sub-images were reconstructed from the readouts collected during each cardiac cycle. These sub-images may then be used for respiratory self-navigation. Alternatively, a CS reconstruction may be used to create these sub-images, so as to partially compensate for the heavy undersampling. Both approaches were quantitatively assessed using simulations and in vivo studies, and the resulting self-navigation strategies were then compared to conventional navigator gating. RESULTS: Sub-images reconstructed using CS showed a lower artifact level than sub-images reconstructed without CS. As a result, the final image quality was significantly better when using CS-assisted self-navigation as opposed to the non-CS approach. Moreover, while both self-navigation techniques led to a 69% scan time reduction (as compared to navigator gating), there was no significant difference in image quality between the CS-assisted self-navigation technique and conventional navigator gating, despite the significant decrease in scan time. CONCLUSIONS: CS-assisted self-navigation using 2D translational motion correction demonstrated feasibility of producing coronary MRA data with image quality comparable to that obtained with conventional navigator gating, and does so without the use of additional acquisitions or motion modeling, while still allowing for 100% scan efficiency and an improved ease-of-use. In conclusion, compressed sensing may become a critical adjunct for 2D translational motion correction in free-breathing cardiac imaging with high spatial resolution. An expansion to modern 3D approaches is now warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE The aim of the study was to determine whether the consumption of low protein dietetic foods improved the quality of life and nutritional status for vitamins B and homocysteine in patients with chronic renal failure. METHODOLOGY This nutritional-intervention involved 28 men and 21 women, divided into two groups. The control-group consumed a low-protein diet prescribed, and the experimental-group consumed a diet in which some commonly used foods were replaced by low-protein dietetic foods. The study lasted 6 months. Food consumption was assessed by 24-h recall. Vitamin B6 as alphaEAST was measured in blood. Creatinine, urea, vitamin B12, folate and homocysteine were measured in plasma. The impact on the patients' quality of life from consuming the dietetic foods was assessed via the SF-36 questionnaire. RESULTS After 6 months, the protein intake among the experimental-group had decreased by 40%, and the urea/creatinine ratio and alphaEAST activity were also lower. The results of the SF-36 questionnaire show that the patients in the experimental-group obtained higher scores in the categories of general health and physical status. CONCLUSIONS The dietetic foods were very well accepted by all patients and their use allowed a better control of the protein intake, improved B6 status and a better quality of life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The shape of the energy spectrum produced by an x-ray tube has a great importance in mammography. Many anode-filtration combinations have been proposed to obtain the most effective spectrum shape for the image quality-dose relationship. On the other hand, third generation synchrotrons such as the European Synchrotron Radiation Facility in Grenoble are able to produce a high flux of monoenergetic radiation. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. An objective method was used to evaluate image quality and dose in mammography with synchrotron radiation and to compare them to standard conventional units. It was performed systematically in the energy range of interest for mammography through the evaluation of a global image quality index and through the measurement of the mean glandular dose. Compared to conventional mammography units, synchrotron radiation shows a great improvement of the image quality-dose relationship, which is due to the beam monochromaticity and to the high intrinsic collimation of the beam, which allows the use of a slit instead of an anti-scatter grid for scatter rejection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Discordances exist in epidemiological studies regarding the association between the intake of nutrients and death and disease. We evaluated the social and health profile of persons who consumed olive oil in a prospective population cohort investigation (Pizarra study) with a 6-year follow-up. A food frequency questionnaire and a 7 d quantitative questionnaire were administered to 538 persons. The type of oil used in food preparation was determined by direct measurement of the fatty acids in samples obtained from the kitchens of the participants at baseline and after follow-up for 6 years. The fatty acid composition of the serum phospholipids was used as an endogenous marker of the type of oil consumed. Total fat intake accounted for a mean 40 % of the energy (at baseline and after follow-up). The concordance in intake of MUFA over the study period was high. The fatty acid composition of the serum phospholipids was significantly associated with the type of oil consumed and with fish intake. The concentration of polar compounds and polymers, indicative of degradation, was greater in oils from the kitchens where sunflower oil or refined olive oil was used, in oils used for deep frying and in oils that had been reused for frying five times or more. Consumption of olive oil was directly associated with educational level. Part of the discordance found in epidemiological studies between diet and health may be due to the handling of oils during food preparation. The intake of olive oil is associated with other healthy habits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Several questionnaires have been used to measure health related quality of life (HRQoL) in patients with psoriasis, few have been adapted for use in Spain; none of them was developed specifically for the Spanish population. The purpose of the study was to validate and assess the sensitivity to change of a new questionnaire to measure HRQOL in patients with psoriasis (PSO-LIFE). METHODS Observational, prospective, multicenter study performed in centers around Spain. Patients with active or inactive psoriasis completed the PSO-LIFE together with other Dermatology Quality of Life Index (DLQI) and Psoriasis Disability Index (PDI). A control group of patients with urticaria or atopic dermatitis was also included. Internal consistency and test-retest reliability of the PSO-LIFE were assessed by calculating Cronbach's alpha and Intraclass Correlation Coefficient (ICC). Validity was assessed by examining factorial structure, the capacity to discriminate between groups, and correlations with other measures. Sensitivity to change was measured using effect sizes. RESULTS The final sample included for analysis consisted of 304 patients and 56 controls. Mean (SD) age of psoriasis patients was 45.3 (14.5) years compared to 38.8 (14) years for controls (p < 0.01). Cronbach's alpha for the PSO-LIFE was 0.95 and test-retest reliability using the ICC was 0.98. Factor analysis showed the questionnaire to be unidimensional. Mean (SD) PSO-LIFE scores differed between patients with psoriasis and controls (64.9 [22.5] vs 69.4 [17.3]; p < 0.05), between those with active and inactive disease (57.4 [20.4] vs 76.4 [20.6]; p < 0.01), and between those with visible and non-visible lesions (63.0 [21.9] vs. 74.8 [23.9]; p < 0.01). The correlation between PSO-LIFE and PASI scores was moderate (r = -0.43) while correlations with DLQI and PDI dimensions ranged from moderate to high (between 0.4 and 0.8). Effect size on the PSO-LIFE in patients reporting 'much improved' health status at study completion was 1.01 (large effect size). CONCLUSIONS The present results provide substantial support for the reliability, validity, and responsiveness of the PSO-LIFE questionnaire in the population for which it was designed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Only multifaceted hospital wide interventions have been successful in achieving sustained improvements in hand hygiene (HH) compliance. METHODOLOGY/PRINCIPAL FINDINGS Pre-post intervention study of HH performance at baseline (October 2007-December 2009) and during intervention, which included two phases. Phase 1 (2010) included multimodal WHO approach. Phase 2 (2011) added Continuous Quality Improvement (CQI) tools and was based on: a) Increase of alcohol hand rub (AHR) solution placement (from 0.57 dispensers/bed to 1.56); b) Increase in frequency of audits (three days every three weeks: "3/3 strategy"); c) Implementation of a standardized register form of HH corrective actions; d) Statistical Process Control (SPC) as time series analysis methodology through appropriate control charts. During the intervention period we performed 819 scheduled direct observation audits which provided data from 11,714 HH opportunities. The most remarkable findings were: a) significant improvements in HH compliance with respect to baseline (25% mean increase); b) sustained high level (82%) of HH compliance during intervention; c) significant increase in AHRs consumption over time; c) significant decrease in the rate of healthcare-acquired MRSA; d) small but significant improvements in HH compliance when comparing phase 2 to phase 1 [79.5% (95% CI: 78.2-80.7) vs 84.6% (95% CI:83.8-85.4), p<0.05]; e) successful use of control charts to identify significant negative and positive deviations (special causes) related to the HH compliance process over time ("positive": 90.1% as highest HH compliance coinciding with the "World hygiene day"; and "negative":73.7% as lowest HH compliance coinciding with a statutory lay-off proceeding). CONCLUSIONS/SIGNIFICANCE CQI tools may be a key addition to WHO strategy to maintain a good HH performance over time. In addition, SPC has shown to be a powerful methodology to detect special causes in HH performance (positive and negative) and to help establishing adequate feedback to healthcare workers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phylogenomic databases provide orthology predictions for species with fully sequenced genomes. Although the goal seems well-defined, the content of these databases differs greatly. Seven ortholog databases (Ensembl Compara, eggNOG, HOGENOM, InParanoid, OMA, OrthoDB, Panther) were compared on the basis of reference trees. For three well-conserved protein families, we observed a generally high specificity of orthology assignments for these databases. We show that differences in the completeness of predicted gene relationships and in the phylogenetic information are, for the great majority, not due to the methods used, but to differences in the underlying database concepts. According to our metrics, none of the databases provides a fully correct and comprehensive protein classification. Our results provide a framework for meaningful and systematic comparisons of phylogenomic databases. In the future, a sustainable set of 'Gold standard' phylogenetic trees could provide a robust method for phylogenomic databases to assess their current quality status, measure changes following new database releases and diagnose improvements subsequent to an upgrade of the analysis procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The comparative analysis of air quality control policies provides an interesting field for studies of comparative policy analysis including program formulation and implementation processes. In European countries, the problem is comparable, whereas implementation structures, programs and policy impacts vary to a considerable extent. Analysis testing possibilities and constraints of air control policies under varying conditions are likely to contribute to a further development of a theory of policy analysis. This paper presents the analytical framework applied in a continuing empirical study explaining program formulation and implementation processes with respect to the different actors involved. Concrete emitter behavior can be explained by interaction processes at the very local level, by program elements of national legislation, and by structural constraints under which such programs are produced.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Associations of hormone-receptor positive breast cancer with excess adiposity are reasonably well characterized; however, uncertainty remains regarding the association of body mass index (BMI) with hormone-receptor negative malignancies, and possible interactions by hormone replacement therapy (HRT) use. METHODS Within the European EPIC cohort, Cox proportional hazards models were used to describe the relationship of BMI, waist and hip circumferences with risk of estrogen-receptor (ER) negative and progesterone-receptor (PR) negative (n = 1,021) and ER+PR+ (n = 3,586) breast tumors within five-year age bands. Among postmenopausal women, the joint effects of BMI and HRT use were analyzed. RESULTS For risk of ER-PR- tumors, there was no association of BMI across the age bands. However, when analyses were restricted to postmenopausal HRT never users, a positive risk association with BMI (third versus first tertile HR = 1.47 (1.01 to 2.15)) was observed. BMI was inversely associated with ER+PR+ tumors among women aged ≤49 years (per 5 kg/m2 increase, HR = 0.79 (95%CI 0.68 to 0.91)), and positively associated with risk among women ≥65 years (HR = 1.25 (1.16 to 1.34)). Adjusting for BMI, waist and hip circumferences showed no further associations with risks of breast cancer subtypes. Current use of HRT was significantly associated with an increased risk of receptor-negative (HRT current use compared to HRT never use HR: 1.30 (1.05 to 1.62)) and positive tumors (HR: 1.74 (1.56 to 1.95)), although this risk increase was weaker for ER-PR- disease (Phet = 0.035). The association of HRT was significantly stronger in the leaner women (BMI ≤22.5 kg/m2) than for more overweight women (BMI ≥25.9 kg/m2) for, both, ER-PR- (HR: 1.74 (1.15 to 2.63)) and ER+PR+ (HR: 2.33 (1.84 to 2.92)) breast cancer and was not restricted to any particular HRT regime. CONCLUSIONS An elevated BMI may be positively associated with risk of ER-PR- tumors among postmenopausal women who never used HRT. Furthermore, postmenopausal HRT users were at an increased risk of ER-PR- as well as ER+PR+ tumors, especially among leaner women. For hormone-receptor positive tumors, but not for hormone-receptor negative tumors, our study confirms an inverse association of risk with BMI among young women of premenopausal age. Our data provide evidence for a possible role of sex hormones in the etiology of hormone-receptor negative tumors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Motive-oriented therapeutic relationship (MOTR, also called complementary therapeutic relationship) was postulated to be a particularly helpful therapeutic ingredient in the early-phase treatment of patients with personality disorders, in particular borderline personality disorder (BPD). The present pilot study of randomized controlled trial using an add-on design aims to investigate the effects of MOTR in early-phase treatment (up to session 10), with BPD patients on therapeutic alliance, session impact, and outcome. In total, N = 25 patients participated in the study. BPD patients were randomly allocated to a manual-based investigation process in 10 sessions or to the same investigation process infused with MOTR. Adherence ratings were performed and yielded satisfactory results. The results suggested a specific effectiveness of MOTR on the interpersonal problem area, on the quality of the therapeutic alliance and the quality of the therapeutic relationship, as rated by the patient. These results may have important clinical implications for the early-phase treatment of patients presenting with BPD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction The Andalusian Public Health System Virtual Library (Biblioteca Virtual del Sistema Sanitario Público de Andalucía, BV-SSPA) was set up in June 2006. It consists of a regional government action with the aim of democratizing the health professional access to quality scientific information, regardless of the professional workplace. Andalusia is a region with more than 8 million inhabitants, with 100,000 health professionals for 41 hospitals, 1,500 primary healthcare centres, and 28 centres for non-medical attention purposes (research, management, and educational centres). Objectives The Department of Development, Research and Investigation (R+D+i) of the Andalusian Regional Government has, among its duties, the task of evaluating the hospitals and centres of the Andalusian Public Health System (SSPA) in order to distribute its funding. Among the criteria used is the evaluation of the scientific output, which is measured using bibliometry. It is well-known that the bibliometry has a series of limitations and problems that should be taken into account, especially when it is used for non-information sciences, such us career, funding, etc. A few years ago, the bibliometric reports were done separately in each centre, but without using preset and well-defined criteria, elements which are basic when we need to compare the results of the reports. It was possible to find some hospitals which were including Meeting Abstracts in their figures, while others do not, and the same was happening with Erratum and many other differences. Therefore, the main problem that the Department of R+D+i had to deal with, when they were evaluating the health system, was that bibliometric data was not accurate and reports were not comparable. With the aim of having an unified criteria for the whole system, the Department of R+D+i ordered the BV-SSPA to do the year analysis of the scientific output of the system, using some well defined criteria and indicators, among whichstands out the Impact Factor. Materials and Methods As the Impact Factor is the bibliometric indicator that the virtual library is asked to consider, it is necessary to use the database Web of Science (WoS), since it is its owner and editor. The WoS includes the databases Science Citation Index (SCI), Social Sciences Citation Index (SSCI) and Arts & Humanities Citation Index. To gather all the documents, SCI and SSCI are used; to obtain the Impact Factor and quartils, it is used the Journal Citation Reports, JCR. Unlike other bibliographic databases, such us MEDLINE, the bibliometric database WoS includes the address of all the authors. In order to retrieve all the scientific output of the SSPA, we have done general searches, which are afterwards processed by a tool developed by our library. We have done nine different searches using the field ‘address’; eight of them including ‘Spain’ and each one of the eight Andalusian Regions, and the other one combining ‘Spain’ with all those cities where there are health centres, since we have detected that there are some authors that do not use the region in their signatures. These are some of the search strategies: AD=Malaga and AD=Spain AD=Sevill* and AD=Spain AD=SPAIN AND (AD=GUADIX OR AD=BAZA OR AD=MOTRIL) Further more, the field ‘year’ is used to determine the period. To exploit the data, the BV-SSPA has developed a tool called Impactia. It is a web application which uses a database to store the information of the documents generated by the SSPA. Impactia allows the user to automatically process the retrieved documents, assigning them to their correspondent centres. In order to do the classification of documents automaticaly, it was necessary to detect the huge variability of names of the centres that the authors use in their signatures. Therefore, Impactia knows that if an author signs as “Hospital Universitario Virgen Macarena”, “HVM” or “Hosp. Virgin Macarena”, he belongs to the same centre. The figure attached shows the variability found for the Empresa Publica Hospital de Poniente. Besides the documents from WoS, Impactia includes the documents indexed in Scopus and in other databases, where we do bibliographic searches using similar strategies to the later ones. Aware that in the health centres and hospitals there is a lot of grey literature that is not gathered in databases, Impactia allows the centres to feed the application with these documents, so that all the SSPA scientific output is gathered and organised in a centralized place. The ones responsible of localizing this gray literature are the librarians of each one of the centres. They can also do statements to the documents and indicators that are collected and calculated by Impactia. The bulk upload of documents from WoS and Scopus into Impactia is monthly done. One of the main issues that we found during the development of Impactia was the need of dealing with duplicated documents obtained from different sources. Taking into account that sometimes titles might be written differently, with slashes, comas, and so on, Impactia detects the duplicates using the field ‘DOI’ if it is available or comparing the fields: page start, page end and ISSN. Therefore it is possible to guarantee the absence of duplicates. Results The data gathered in Impactia becomes available to the administrative teams and hospitals managers, through an easy web page that allows them to know at any moment, and with just one click, the detailed information of the scientific output of their hospitals, including useful graphs such as percentage of document types, journals where their scientists usually publish, annual comparatives, bibliometric indicators and so on. They can also compare the different centres of the SSPA. Impactia allows the user to download the data from the application, so that he can work with this information or include them in their centres’ reports. This application saves the health system many working hours. It was previously done manually by forty one librarians, while now it is done by only one person in the BV-SSPA during two days a month. To sum up, the benefits of Impactia are: It has shown its effectiveness in the automatic classification, treatment and analysis of the data. It has become an essential tool for all managers to evaluate quickly and easily the scientific production of their centers. It optimizes the human resources of the SSPA, saving time and money. It is the reference point for the Department of R+D+i to do the scientific health staff evaluation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUNDS AUDIPOC is a nationwide clinical audit that describes the characteristics, interventions and outcomes of patients admitted to Spanish hospitals because of an exacerbation of chronic obstructive pulmonary disease (ECOPD), assessing the compliance of these parameters with current international guidelines. The present study describes hospital resources, hospital factors related to case recruitment variability, patients' characteristics, and adherence to guidelines. METHODOLOGY/PRINCIPAL FINDINGS An organisational database was completed by all participant hospitals recording resources and organisation. Over an 8-week period 11,564 consecutive ECOPD admissions to 129 Spanish hospitals covering 70% of the Spanish population were prospectively identified. At hospital discharge, 5,178 patients (45% of eligible) were finally included, and thus constituted the audited population. Audited patients were reassessed 90 days after admission for survival and readmission rates. A wide variability was observed in relation to most variables, hospital adherence to guidelines, and readmissions and death. Median inpatient mortality was 5% (across-hospital range 0-35%). Among discharged patients, 37% required readmission (0-62%) and 6.5% died (0-35%). The overall mortality rate was 11.6% (0-50%). Hospital size and complexity and aspects related to hospital COPD awareness were significantly associated with case recruitment. Clinical management most often complied with diagnosis and treatment recommendations but rarely (<50%) addressed guidance on healthy life-styles. CONCLUSIONS/SIGNIFICANCE The AUDIPOC study highlights the large across-hospital variability in resources and organization of hospitals, patient characteristics, process of care, and outcomes. The study also identifies resources and organizational characteristics associated with the admission of COPD cases, as well as aspects of daily clinical care amenable to improvement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

En aquest treball, es proposa un nou mètode per estimar en temps real la qualitat del producte final en processos per lot. Aquest mètode permet reduir el temps necessari per obtenir els resultats de qualitat de les anàlisi de laboratori. S'utiliza un model de anàlisi de componentes principals (PCA) construït amb dades històriques en condicions normals de funcionament per discernir si un lot finalizat és normal o no. Es calcula una signatura de falla pels lots anormals i es passa a través d'un model de classificació per la seva estimació. L'estudi proposa un mètode per utilitzar la informació de les gràfiques de contribució basat en les signatures de falla, on els indicadors representen el comportament de les variables al llarg del procés en les diferentes etapes. Un conjunt de dades compost per la signatura de falla dels lots anormals històrics es construeix per cercar els patrons i entrenar els models de classifcació per estimar els resultas dels lots futurs. La metodologia proposada s'ha aplicat a un reactor seqüencial per lots (SBR). Diversos algoritmes de classificació es proven per demostrar les possibilitats de la metodologia proposada.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose of the study: Basic life support (BLS) and automated externaldefibrillation (AED) represent important skills to be acquired duringpregraduate medical training. Since 3 years, our medical school hasintroduced a BLS-AED course (with certification) for all second yearmedical students. Few reports about quality and persistence over timeof BLS-AED learning are available to date in the medical literature.Comprehensive evaluation of students' acquired skills was performedat the end of the 2008 academic year, 6 month after certification.Materials and methods: The students (N = 142) were evaluated duringa 9 minutes «objective structured clinical examination» (OSCE) station.Out of a standardized scenario, they had to recognize a cardiac arrestsituation and start a resuscitation process. Their performance wererecorded on a PC using an Ambuman(TM) mannequin and the AmbuCPR software kit(TM) during a minimum of 8 cycles (30 compressions:2 ventilations each). BLS parameters were systematically checked. Nostudent-rater interactions were allowed during the whole evaluation.Results: Response of the victim was checked by 99% of the students(N = 140), 96% (N = 136) called for an ambulance and/or an AED. Openthe airway and check breathing were done by 96% (N = 137), 92% (N =132) gave 2 rescue breaths. Pulse was checked by 95% (N=135), 100%(N = 142) begun chest compression, 96% (N = 136) within 1 minute.Chest compression rate was 101 ± 18 per minute (mean ± SD), depthcompression 43 ± 8 mm, 97% (N = 138) respected a compressionventilationratio of 30:2.Conclusions: Quality of BLS skills acquisition is maintained during a6-month period after a BLS-AED certification. Main targets of 2005 AHAguidelines were well respected. This analysis represents one of thelargest evaluations of specific BLS teaching efficiency reported. Furtherfollow-up is needed to control the persistence of these skills during alonger time period and noteworthy at the end of the pregraduatemedical curriculum.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To evaluate the rate of hospitalization for acute respiratory tract infection in children less than 24 months with haemodynamically significant congenital cardiac disease, and to describe associated risk factors, preventive measures, aetiology, and clinical course. MATERIALS AND METHODS We followed 760 subjects from October 2004 through April 2005 in an epidemiological, multicentric, observational, follow-up, prospective study involving 53 Spanish hospitals. RESULTS Of our cohort, 79 patients (10.4%, 95% CI: 8.2%-12.6%) required a total of 105 admissions to hospital related to respiratory infections. The incidence rate was 21.4 new admissions per 1000 patients-months. Significant associated risk factors for hospitalization included, with odds ratios and 95% confidence intervals shown in parentheses: 22q11 deletion (8.2, 2.5-26.3), weight below the 10th centile (5.2, 1.6-17.4), previous respiratory disease (4.5, 2.3-8.6), incomplete immunoprophylaxis against respiratory syncytial virus (2.2, 1.2-3.9), trisomy 21 (2.1, 1.1-4.2), cardiopulmonary bypass (2.0, 1.1-3.4), and siblings aged less than 11 years old (1.7, 1.1-2.9). Bronchiolitis (51.4%), upper respiratory tract infections (25.7%), and pneumonia (20%) were the main diagnoses. An infectious agent was found in 37 cases (35.2%): respiratory syncytial virus in 25, Streptococcus pneumoniae in 5, and Haemophilus influenzae in 4. The odds ratio for hospitalization due to infection by the respiratory syncytial virus increases by 3.05 (95% CI: 2.14 to 4.35) in patients with incomplete prophylaxis. The median length of hospitalization was 7 days. In 18 patients (17.1%), the clinical course of respiratory infection was complicated and 2 died. CONCLUSIONS Hospital admissions for respiratory infection in young children with haemodynamically significant congenital cardiac disease are mainly associated with non-cardiac conditions, which may be genetic, malnutrition, or respiratory, and to cardiopulmonary bypass. Respiratory syncytial virus was the most commonly identified infectious agent. Incomplete immunoprophylaxis against the virus increased the risk of hospitalization.