997 resultados para QUADRUPOLE DOUBLE-RESONANCE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a method to analytically show the possibility for the appearance of a maximum in the signal-to-noise ratio in nonpotential systems. We apply our results to the FitzHugh-Nagumo model under a periodic external forcing, showing that the model exhibits stochastic resonance. The procedure that we follow is based on the reduction to a one-dimensional dynamics in the adiabatic limit and in the topology of the phase space of the systems under study. Its application to other nonpotential systems is also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that a dispersion of monodomain ferromagnetic particles in a solid phase exhibits stochastic resonance when a driven linearly polarized magnetic field is applied. By using an adiabatic approach, we calculate the power spectrum, the distribution of residence times, and the mean first passage time. The behavior of these quantities is similar to the behavior of corresponding quantities in other systems where stochastic resonance has also been observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative information from magnetic resonance imaging (MRI) may substantiate clinical findings and provide additional insight into the mechanism of clinical interventions in therapeutic stroke trials. The PERFORM study is exploring the efficacy of terutroban versus aspirin for secondary prevention in patients with a history of ischemic stroke. We report on the design of an exploratory longitudinal MRI follow-up study that was performed in a subgroup of the PERFORM trial. An international multi-centre longitudinal follow-up MRI study was designed for different MR systems employing safety and efficacy readouts: new T2 lesions, new DWI lesions, whole brain volume change, hippocampal volume change, changes in tissue microstructure as depicted by mean diffusivity and fractional anisotropy, vessel patency on MR angiography, and the presence of and development of new microbleeds. A total of 1,056 patients (men and women ≥ 55 years) were included. The data analysis included 3D reformation, image registration of different contrasts, tissue segmentation, and automated lesion detection. This large international multi-centre study demonstrates how new MRI readouts can be used to provide key information on the evolution of cerebral tissue lesions and within the macrovasculature after atherothrombotic stroke in a large sample of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Direct noninvasive visualization of the coronary vessel wall may enhance risk stratification by quantifying subclinical coronary atherosclerotic plaque burden. We sought to evaluate high-resolution black-blood 3D cardiovascular magnetic resonance (CMR) imaging for in vivo visualization of the proximal coronary artery vessel wall. METHODS AND RESULTS: Twelve adult subjects, including 6 clinically healthy subjects and 6 patients with nonsignificant coronary artery disease (10% to 50% x-ray angiographic diameter reduction) were studied with the use of a commercial 1.5 Tesla CMR scanner. Free-breathing 3D coronary vessel wall imaging was performed along the major axis of the right coronary artery with isotropic spatial resolution (1.0x1.0x1.0 mm(3)) with the use of a black-blood spiral image acquisition. The proximal vessel wall thickness and luminal diameter were objectively determined with an automated edge detection tool. The 3D CMR vessel wall scans allowed for visualization of the contiguous proximal right coronary artery in all subjects. Both mean vessel wall thickness (1.7+/-0.3 versus 1.0+/-0.2 mm) and wall area (25.4+/-6.9 versus 11.5+/-5.2 mm(2)) were significantly increased in the patients compared with the healthy subjects (both P<0.01). The lumen diameter (3.6+/-0.7 versus 3.4+/-0.5 mm, P=0.47) and lumen area (8.9+/-3.4 versus 7.9+/-3.5 mm(2), P=0.47) were similar in both groups. CONCLUSIONS: Free-breathing 3D black-blood coronary CMR with isotropic resolution identified an increased coronary vessel wall thickness with preservation of lumen size in patients with nonsignificant coronary artery disease, consistent with a "Glagov-type" outward arterial remodeling. This novel approach has the potential to quantify subclinical disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One hundred and eighty nine patients with primary biliary cirrhosis were entered into a double blind, placebo controlled randomised trial starting in January 1978 to assess the therapeutic value of d-penicillamine 1200 mg daily. Eighteen of the 98 patients receiving d-penicillamine and 22 of the 91 placebo treated patients died during the study. Thirty six per cent of those on d-penicillamine and 8% of those on placebo were withdrawn from the study. No difference in overall survival was noted between the two groups of patients whether the results were analysed for the entire period of observation or only during the period in which the patients were receiving therapy. The mortality rate of those receiving d-penicillamine in histological stage I to II, however, was one third of that of the placebo group although this difference did not reach statistical significance. Using the occurrence rate ratio as the statistical method of analysis, no effect of d-penicillamine was noted on any clinical, biochemical or hist

Relevância:

20.00% 20.00%

Publicador:

Resumo:

N. Boillat Blanco, R. Kuonen, C. Bellini, O. Manuel, C. Estrade, J. Mazza-Stalder, J.D. Aubert, R. Sahli, P. Meylan. Chronic norovirus gastroenteritis in a double hematopoietic stem cell and lung transplant recipient. Transpl Infect Dis 2011: 13: 213-215. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present numerical evidence and a theoretical analysis of the appearance of anticoherence resonance induced by noise, not predicted in former analysis of coherence resonance. We have found that this phenomenon occurs for very small values of the intensity of the noise acting on an excitable system, and we claim that this is a universal signature of a nonmonotonous relaxational behavior near its oscillatory regime. Moreover, we demonstrate that this new phenomenon is totally compatible with the standard situation of coherence resonance appearing at intermediate values of noise intensity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use temperature tuning to control signal propagation in simple one-dimensional arrays of masses connected by hard anharmonic springs and with no local potentials. In our numerical model a sustained signal is applied at one site of a chain immersed in a thermal environment and the signal-to-noise ratio is measured at each oscillator. We show that raising the temperature can lead to enhanced signal propagation along the chain, resulting in thermal resonance effects akin to the resonance observed in arrays of bistable systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: The time course of atherosclerosis burden in distinct vascular territories remains poorly understood. We longitudinally evaluated the natural history of atherosclerotic progression in two different arterial territories using high spatial resolution magnetic resonance imaging (HR-MRI), a powerful, safe, and non-invasive tool. METHODS AND RESULTS: We prospectively studied a cohort of 30 patients (mean age 68.3, n = 9 females) with high Framingham general cardiovascular disease 10-year risk score (29.5%) and standard medical therapy with mild-to-moderate atherosclerosis intra-individually at the level of both carotid and femoral arteries. A total of 178 HR-MRI studies of carotid and femoral arteries performed at baseline and at 1- and 2-year follow-up were evaluated in consensus reading by two experienced readers for lumen area (LA), total vessel area (TVA), vessel wall area (VWA = TVA - LA), and normalized wall area index (NWI = VWA/TVA). At the carotid level, LA decreased (-3.19%/year, P = 0.018), VWA increased (+3.83%/year, P = 0.019), and TVA remained unchanged. At the femoral level, LA remained unchanged, VWA and TVA increased (+5.23%/year and +3.11%/year, both P < 0.01), and NWI increased for both carotid and femoral arteries (+2.28%/year, P = 0.01, and +1.8%/year, P = 0.033). CONCLUSION: The atherosclerotic burden increased significantly in both carotid and femoral arteries. However, carotid plaque progression was associated with negative remodelling, whereas the increase in femoral plaque burden was compensated by positive remodelling. This finding could be related to anatomic and flow differences and/or to the distinct degree of obstruction in the two arterial territories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To evaluate the prevalence of acute coronary syndrome (ACS) in patients presenting initially with atypical chest pain and suspected to have pulmonary embolism (PE) or acute aortic syndromes (AAS). To evaluate the overlap between ACS, PE and AAS in routine practice and determine how many patients could have benefit from a single CT protocol to rule out ACS at the same time as PE and AAS. METHOD AND MATERIALS Our electronic hospital database revealed 1122 consecutive patients who underwent a thoracic CT angiography for PE or AAS from 2004 to 2006 (mean age, 63±13 years). Patients without chest pain were excluded from this study. Thus, 447 patients presented with isolated atypical chest were included in the analysis. All patients who underwent a thoracic CT scan previously received standard clinical care and were initially considered as non ACS. The final diagnosis was obtained by the hospital stay report. RESULTS Among the 447 patients with atypical chest pain, 25 (5.5%) were finally found to have ACS: 19 patients (4.2%) were suspected for PE and 6 (1. 3%) were suspected for AAS. There were 90 patients diagnosed to have PE, 89 (98.8%) of them were suspected for PE while only 1 (1%) was suspected for AAS. Eleven patients diagnosed to have AAS, 9 (82%) of them were suspected for AAS while 2 (18%) were suspected for PE. CONCLUSION In clinical practice, the overlap between PE, AAS and ACS is limited which make the triple rule-out studies less recommended to be done at the time being because of the high dose radiation. A double rule-out investigation is suggested to be done for patients being evaluated for atypical chest pain and suspected of having AAS or PE because of a significant overlap between the two entities as well it doesn't implicate any increment in radiation dose. CLINICAL RELEVANCE/APPLICATION With 64-slice CT, coronary circulation and total chest can be evaluated at the same time offering new opportunitie for the evaluation of three major life-threatening conditions :ACS,PE and AAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The known genetic mutation causing Huntington's disease (HD) makes this disease an important model to study links between gene and brain function. An autosomal dominant family history and the availability of a sensitive and specific genetic test allow pre-clinical diagnosis many years before the onset of any typical clinical signs. This review summarizes recent magnetic resonance imaging (MRI)-based findings in HD with a focus on the requirements if imaging is to be used in treatment trials. Despite its monogenetic cause, HD presents with a range of clinical manifestations, not explained by variation in the number of CAG repeats in the affected population. Neuroimaging studies have revealed a complex pattern of structural and functional changes affecting widespread cortical and subcortical regions far beyond the confines of the striatal degeneration that characterizes this disorder. Besides striatal dysfunction, functional imaging studies have reported a variable pattern of increased and decreased activation in cortical regions in both pre-clinical and clinically manifest HD-gene mutation carriers. Beyond regional brain activation changes, evidence from functional and diffusion-weighted MRI further suggests disrupted connectivity between corticocortical and corticostriatal areas. However, substantial inconsistencies with respect to structural and functional changes have been reported in a number of studies. Possible explanations include methodological factors and differences in study samples. There may also be biological explanations but these are poorly characterized and understood at present. Additional insights into this phenotypic variability derived from study of mouse models are presented to explore this phenomenon.