986 resultados para Pressure support


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the use of the intraaortic balloon (IAoB) in association with coronary angioplasty in high-risk patients. METHODS: Fourteen high-risk patients unresponsive to clinical therapy and with formal contraindication to surgical revascularization were treated by coronary angioplasty, most of which was followed by stenting. All procedures were performed with circulatory support with the IAoB. This study reports the early results and the late findings after 12 months of follow-up. Six patients had multivessel coronary disease; of these, four had left main equivalent lesions and two had unprotected left main coronary artery disease, one of whom had severe "end-vessel" stenosis and the other was a patient with Chagas' disease with single-vessel lesion. Eleven patients had a left ventricular ejection fraction <30%. RESULTS: In 100% of the patients, the procedures were initially successful. Two patients had severe bleeding during the withdrawal of the left femoral sheath. At the end of twelve months, 4 patients were asymptomatic and the others were clinically controlled. There were two late deaths in the 7th and 11th months. CONCLUSION: The combined use of the intraaortic balloon pump and percutaneous coronary angioplasty in high-risk patients with acute ischemic syndromes provides the necessary hemodynamic stability to successfully perform the procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine if abnormal laboratory findings are more common in individuals with hypertension and in those with other risk factors, such as obesity, smoking and alcohol ingestion. METHODS: A study was carried out in the general outpatient clinics of a university hospital (145 individuals without previous diagnosis of hypertension) and the following variables were assessed: high blood pressure (as defined by the VI Joint National Committee on Prevention, Detection and Treatment of High Blood Pressure - VI JNC), obesity [calculated using body mass index (BMI)], tobacco use, and alcoholic ingestion. The laboratory examinations consisted of the following tests: hemogram, glycemia, uric acid, potassium, total/HDL-fraction cholesterol, triglycerides, calcium and creatinine. RESULTS: High blood pressure was not associated with a higher number of abnormal laboratory tests. Hypertensive individuals with a BMI > or = 25kg/m² or normotensive obese individuals, however, had a higher frequency of diabetes (12X), hypertriglyceridemia (3X), and hypercholesterolemia (2X), as compared with hypertensive individuals with BMI <25kg/m² and preobese/normal weight normotensive individuals. CONCLUSION: High blood pressure is not associated with a higher frequency of abnormal laboratory tests. The association of high blood pressure and obesity, however, increases the detection of diabetes and dyslipidemias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of the siesta in ambulatory blood pressure (BP) monitoring and in cardiac structure parameters. METHODS: 1940 ambulatory arterial blood pressure monitoring tests were analyzed (Spacelabs 90207, 15/15 minutes from 7:00 to 22:00 hours and 20/20 minutes from 22:01 to 6.59hours) and 21% of the records indicated that the person had taken a siesta (263 woman, 52±14 years). The average duration of the siesta was 118±58 minutes. RESULTS: (average ± standard deviation) The average of systolic/diastolic pressures during wakefulness, including the napping period, was less than the average for the period not including the siesta (138±16/85±11 vs 139±16/86±11 mmHg, p<0.05); 2) pressure loads during wakefulness including the siesta, were less than those observed without the siesta); 3) the averages of nocturnal sleep blood pressures were similar to those of the siesta, 4) nocturnal sleep pressure drops were similar to those in the siesta including wakefulness with and without the siesta; 5) the averages of BP in men were higher (p<0.05) during wakefulness with and without the siesta, during the siesta and nocturnal sleep in relation to the average obtained in women; 6) patients with a reduction of 0- 5% during the siesta had thickening of the interventricular septum and a larger posterior wall than those with a reduction during the siesta >5%. CONCLUSION: The siesta influenced the heart structure parameters and from a statistical point of view the average of systolic and diastolic pressures and the respective pressure loads of the wakeful period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the effect of transient and sustained variations in cardiac load on the values of the end-systolic pressure-diameter relation (ESPDR) of the left ventricle. METHODS: We studied 13 dogs under general anesthesia and autonomic blockade. Variations of cardiac loads were done by elevation of blood pressure by mechanical constriction of the aorta. Two protocols were used in each animal: gradual peaking and decreasing pressure variation, the "transient arterial hypertension protocol" (TAH), and a quick and 10 min sustained elevation, the "sustained arterial hypertension protocol"(SAH). Then, we compared the ESDR in these two situations. RESULTS: Acute elevation of arterial pressure, being it "transitory" or "sustained", did not alter the heart frequency and increased similarly the preload and after load. However, they acted differently in end systolic pressure-diameter relation. It was greater in the SAH than TAH protocol, 21.0±7.3mmHg/mm vs. 9.2±1.2mmHg/mm (p<0.05). CONCLUSION: The left ventricular ESPDR values determined during sustained pressure elevations were higher than those found during transient pressure elevations. The time-dependent activation of myocardial contractility associated with the Frank-Starling mechanism is the major factor in inotropic stimulation during sustained elevations of blood pressure, determining an increase in the ESPDR values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Studies have demonstrated that methylxanthines, such as caffeine, are A1 and A2 adenosine receptor antagonists found in the brain, heart, lungs, peripheral vessels, and platelets. Considering the high consumption of products with caffeine in their composition, in Brazil and throughout the rest of the world, the authors proposed to observe the effects of this substance on blood pressure and platelet aggregation. METHODS: Thirteen young adults, ranging from 21 to 27 years of age, participated in this study. Each individual took 750mg/day of caffeine (250mg tid), over a period of seven days. The effects on blood pressure were analyzed through the pressor test with handgrip, and platelet aggregation was analyzed using adenosine diphosphate, collagen, and adrenaline. RESULTS: Diastolic pressure showed a significant increase 24 hours after the first intake (p<0.05). This effect, however, disappeared in the subsequent days. The platelet aggregation tests did not reveal statistically significant alterations, at any time during the study. CONCLUSION: The data suggest that caffeine increases diastolic blood pressure at the beginning of caffeine intake. This hypertensive effect disappears with chronic use. The absence of alterations in platelet aggregation indicates the need for larger randomized studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the association between microalbuminuria with ambulatory blood pressure monitoring in normotensive individuals with insulin-dependent diabetes mellitus. METHODS: Thirty-seven patients underwent determination of the rate of urinary excretion of albumin through radioimmunoassay and ambulatory blood pressure monitoring. Their mean age was 26.5±6.7 years, and the mean duration of their disease was 8 (1-34) years. Microalbuminuria was defined as urinary excretion of albumin > or = 20 and <200µg/min in at least 2 out of 3 urine samples. RESULTS: Nine (24.3%) patients were microalbuminuric. Ambulatory blood pressure monitoring in the microalbuminuric patients had higher mean pressure values, mainly the systolic pressure, during sleep as compared with that in the normoalbuminuric patients (120.1±8.3 vs 110.8±7.1 mmHg; p=0.007). The pressure load was higher in the microalbuminuric individuals, mainly the systolic pressure load during wakefulness [6.3 (2.9-45.9) vs 1.6 (0-16%); p=0.001]. This was the variable that better correlated with the urinary excretion of albumin (rS=0.61; p<0.001). Systolic pressure load >50% and diastolic pressure load > 30% during sleep was associated with microalbuminuria (p=0.008). The pressure drop during sleep did not differ between the groups. CONCLUSION: Microalbuminuric normotensive insulin-dependent diabetic patients show greater mean pressure value and pressure load during ambulatory blood pressure monitoring, and these variables correlate with urinary excretion of albumin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the behavior of blood pressure during exercise in patients with hypertension controlled by frontline antihypertension drugs. METHODS: From 979ergometric tests we retrospectively selected 49 hipertensive patients (19 males). The age was 53±12 years old and normal range rest arterial pressure (<=140/90 mmHg) all on pharmacological monotherapy. There were 12 on beta blockers; 14 on calcium antagonists, 13 on diuretics and 10 on angiotensin converting enzyme inhibitor. Abnormal exercise behhavior of blood pressure was diagnosed if anyone of the following criteria was detected: peak systolic pressure above 220 mmHg, raising of systolic pressure > or = 10 mmHg/MET; or increase of diastolic pressure greater than 15 mmHg. RESULTS: Physiologic response of arterial blood pressure occurred in 50% of patients on beta blockers, the best one (p<0.05), in 36% and 31% on calcium antagonists and on diuretics, respectively, and in 20% on angiotensin converting enzyme inhibitor, the later the leastr one (p<0.05). CONCLUSION: Beta-blockers were more effective than calcium antagonists, diuretics and angiotensin-converting enzyme inhibitors in controlling blood pressure during exercise, and angiotensin converting enzyme inhibitors the least effective drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To use published Hypertension Optimal Treatment (HOT) Study data to evaluate changes in cardiovascular mortality in nondiabetic hypertensive patients according to the degree of reduction in their diastolic blood pressure. METHODS: In the HOT Study, 18,700 patients from various centers were allocated at random to groups having different objectives of for diastolic blood pressure: <=90 (n=6264); <=85 (n=6264); <=80mmHg (n=6262). Felodipine was the basic drug used. Other antihypertensive drugs were administered in a sequential manner, aiming at the objectives of diastolic blood pressure reduction. RESULTS: The group of nondiabetic hypertensive subjects with diastolic pressure<=80mmHg had a cardiovascular mortality ratio of 4.1/1000 patients/year, 35.5% higher than the group with diastolic pressure <=90mmHg (cardiovascular mortality ratio, 3.1/1000 patients/year). In contrast, diabetic patients allocated to the diastolic pressure objective group of <=80mmHg had a 66.7% reduction in cardiovascular mortality (3.7/1000 patients/year) when compared with the diastolic pressure group of <=90mmHg (cardiovascular mortality ratio, 11.1/1000 patients/year). CONCLUSION: The results indicate that in hypertensive diabetic patients reduction in diastolic blood pressure to levels <=80mmHg decreases the risk of fatal cardiovascular events. It remains necessary to define the level of diastolic blood pressure <=90mmHg at which maximal reduction in cardiovascular mortality is obtained for nondiabetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the frequency of oral antihypertensive medication preceding the increase in blood pressure in patients in a university hospital, the drug of choice, and the maintained use of antihypertensive medication. METHODS: Data from January to June 1997 from the University Hospital Professor Edgard Santos Pharmacy concerning the prescriptions of all inpatients were used. Variables included in the analysis were: antihypertensive medication prescription preceding increase in blood pressure, type of antihypertensive medication, gender, clinical or surgical wards, and the presence of maintained antihypertensive medication. RESULTS: The hospital admitted 2,532 patients, 1,468 in surgical wards and 818 in medical wards. Antihypertensive medication prescription preceding pressure increase was observed in 578 patients (22.8%). Nifedipine was used in 553 (95.7%) and captopril in 25 (4.3%). In 50.7% of patients, prescription of antihypertensive medication was not associated with maintained antihypertensive medication. Prescription of antihypertensive drugs preceding elevation of blood pressure was significantly (p<0.001) more frequent on the surgical floor (27.5%; 405/1468) than on the medical floor (14.3%; 117/818). The frequency of prescription of antihypertensive drugs preceding elevation of blood pressure without maintained antihypertensive drugs and the ratio between the number of prescriptions of nifedipine and captopril were greater in surgical wards. CONCLUSION: The use of antihypertensive medication, preceding elevation of blood pressure (22.8%) observed in admitted patients is not supported by scientific evidence. The high frequency of this practice may be even greater in nonuniversity hospitals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare sleepiness scores of the Epworth scale in patients with different levels of arterial pressure when undergoing outpatient monitoring within the context of clinical evaluation. METHODS: A total of 157 patients selected for outpatient monitoring of arterial pressure during hypertension evaluation were divided into 3 groups: group 1 - normotensive; group 2 - hypertensive; group 3 - resistant hypertensive. For analysis, values > or = 11 were considered as associated with respiratory disturbances during sleep. RESULTS: Seventeen (10.8%) patients in group 1, 112 (71.3%) in group 2, and 28 (17.8%) in group 3, which was composed of aged, more severely hypertensive individuals, were analyzed. Groups were similar relative to sex and body mass index, but different in relation to systolic and diastolic pressure levels and age. Despite an absolute difference, no statistically significant difference occurred between Epworth scores and in the proportion of patients with values > or = 11 (5.9% vs. 18.8% vs. 212.4%; P=0.37). Despite the positive association between degree of sleepiness measured with the scale and the severity of the hypertension, no statistical significance occurred following control by age (p=0.18). CONCLUSION: A positive correlation exists between degree of sleepiness and hypertension severity. The absence of a statistical significance shown in the present study could be due to a beta type of error. Instruments that render this complaint into an objective finding could help in the pursuit of an investigation of respiratory disturbances during sleep in more severely hypertensive patients, and should therefore be studied better.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the relationship between 24-hour ambulatory arterial blood pressure monitoring and the prognosis of patients with advanced congestive heart failure. METHODS: We studied 38 patients with NYHA functional class IV congestive heart failure, and analyzed left ventricular ejection fraction, diastolic diameter, and ambulatory blood pressure monitoring data. RESULTS: Twelve deaths occurred. Left ventricular ejection fraction (35.2±7.3%) and diastolic diameter (72.2±7.8mm) were not correlated with the survival. The mean 24-hour (SBP24), waking (SBPw), and sleeping (SBPs) systolic pressures of the living patients were higher than those of the deceased patients and were significant for predicting survival. Patients with mean SBP24, SBPv, and SBPs > or = 105mmHg had longer survival (p=0.002, p=0.01 and p=0.0007, respectively). Patients with diastolic blood pressure sleep decrements (dip) and patients with mean blood pressure dip <=6mmHg had longer survival (p=0.04 and p=0.01, respectively). In the multivariate analysis, SBPs was the only variable with an odds ratio of 7.61 (CI: 1.56; 3704) (p=0.01). Patients with mean SBP<105mmHg were 7.6 times more likely to die than those with SBP > or = 105 mmHg CONCLUSION: Ambulatory blood pressure monitoring appears to be a useful method for evaluating patients with congestive heart failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanical Ventilation is an artificial way to help a Patient to breathe. This procedure is used to support patients with respiratory diseases however in many cases it can provoke lung damages, Acute Respiratory Diseases or organ failure. With the goal to early detect possible patient breath problems a set of limit values was defined to some variables monitored by the ventilator (Average Ventilation Pressure, Compliance Dynamic, Flow, Peak, Plateau and Support Pressure, Positive end-expiratory pressure, Respiratory Rate) in order to create critical events. A critical event is verified when a patient has a value higher or lower than the normal range defined for a certain period of time. The values were defined after elaborate a literature review and meeting with physicians specialized in the area. This work uses data streaming and intelligent agents to process the values collected in real-time and classify them as critical or not. Real data provided by an Intensive Care Unit were used to design and test the solution. In this study it was possible to understand the importance of introduce critical events for Mechanically Ventilated Patients. In some cases a value is considered critical (can trigger an alarm) however it is a single event (instantaneous) and it has not a clinical significance for the patient. The introduction of critical events which crosses a range of values and a pre-defined duration contributes to improve the decision-making process by decreasing the number of false positives and having a better comprehension of the patient condition.