997 resultados para Practical tests
Resumo:
Purpose To compare the predictive capability of HPV and Pap smear tests for screening pre-cancerous lesions of the cervix over a three-year follow-up, in a population of users of the Brazilian National Health System (SUS). Methods This is a retrospective cohort study of 2,032 women with satisfactory results for Pap smear and HPV tests using second-generation hybrid capture,made in a previous study. We followed them for 36 months with data obtained from medical records, the Cervix Cancer Information System (SISCOLO), and the Mortality Information System (SIM). The outcome was a histological diagnosis of cervical intraepithelial neoplasia grade 2 or more advanced lesions (CIN2ş). We constructed progression curves of the baseline test results for the period, using the Kaplan-Meier method, and estimated sensitivity, specificity, positive and negative predictive value, and positive and negative likelihood ratios for each test. Results A total of 1,440 women had at least one test during follow-up. Progression curves of the baseline test results indicated differences in capability to detect CIN2ş (p < 0.001) with significantly greater capability when both tests were abnormal, followed by only a positive HPV test. The HPV test was more sensitive than the Pap smear (88.7% and 73.6%, respectively; p < 0.05) and had a better negative likelihood ratio (0.13 and 0.30, respectively). Specificity and positive likelihood ratio of the tests were similar. Conclusions These findings corroborate the importance of HPV test as a primary cervical cancer screening.
Resumo:
Mekanisoinnin ja automaation osuuden lisääminen hitsaustuotannossa on eräs keino hitsaavan teollisuuden kilpailukyvyn tehostamiseksi. Tässä työssä tutkittiin hitsaustyön tehostamista mekanisoinnin keinoin. Työ tehtiin Rämö Oy:n konepajalla Imatralla, todellisia tuotantokappaleita vastaavilla koekappaleilla. Teoriaosuudessa on läpikäyty hitsauksen mekanisointia, kappaleenkäsittelyä ja erilaisia hitsausprosesseja. Osuudessa on käsitelty myös mekanisoidun hitsauksen laatua ja laadunvarmistusta. Kohdeyrityksen tuotannon nykytilanteen kartoitus on esitetty tässä osuudessa. Käytännön osuudessa on käsitelty hitsauskokeiden suoritus, kokeiden tulokset sekä niiden analysointi. Tuloksista voidaan todeta kevytmekanisoinnin olevan kustannustehokas keino hitsaustyön tehokkuuden sekä laadun parantamiseksi. Työn tuloksia tullaan käyttämään hyödyksi kehitettäessä hitsaavaa tuotantoa Rämö Oy:ssä.
Biophysical modeling of photosynthetic electron transfer and practical applications to cyanobacteria
Resumo:
Large amplitude bus bar aeolian vibration may lead to post insulator damage. Different damping applications are used to decrease the risk of large amplitude aeolian vibration. In this paper the post insulator load caused by the bus bar aeolian vibration and the effect of damping methods are evaluated. The effects of three types of bus bar connectors and three types of primary structures are studied. Two actual damping devices, damping cable and their combinations are studied. The post insulator loads are studied with strain gage based custom made force sensors installed on the both ends of the post insulator and with the displacement sensor installed on the midpoint of the bus bar. The post insulator loads are calculated from the strain values and the damping properties are determined from the displacement history. The bus bar is deflected with a hanging weight. The weight is released and the bus bar is left to free damped vibration. Both actual bus bar vibration dampers RIBE and SBI were very effective against the aeolian vibration. Combining vibration damper with damping cable will increase the damping ratio but it may be unnecessary considering the extra effort. Bus bar connector type or primary structure have no effect on the vertical load. The bending moment at the post insulator with double sided bus bar connector is significantly higher than at the post insulator with single sided bus bar connector. No reliable conclusions about bus bar connector type effect can be done, but the roller bearing type or central bearing type connector may reduce the bending moment. The RHS steel frame as primary structure may increase the bending moment peak values since it is the least rigid primary structure type and it may start to vibrate as a response to the awakening force of the vibrating bus bar.
Resumo:
The objective of this study was to evaluate herd management practices and mastitis treatment procedures as risk factors associated with Staphylococcus aureus antimicrobial resistance. For this study, 13 herds were selected to participate in the study to evaluate the association between their management practices and mastitis treatment procedures and in vitro antimicrobial susceptibility. A total of 1069 composite milk samples were collected aseptically from the selected cows in four different periods over two years. The samples were used for microbiological culturing of S. aureus isolates and evaluation of their antimicrobial susceptibility. A total of 756 samples (70.7%) were culture-positive, and S. aureus comprised 27.77% (n=210) of the isolates. The S. aureus isolates were tested using the disk-diffusion susceptibility assay with the following antimicrobials: ampicillin 10mg; clindamycin 2μg; penicillin 1mg; ceftiofur 30μg; gentamicin 10mg; sulfa-trimethoprim 25μg; enrofloxacin 5μg; sulfonamide 300μg; tetracycline 30μg; oxacillin 1mg; cephalothin 30μg and erythromycin 5μg. The variables that were significantly associated with S. aureus resistance were as follows: the treatment of clinical mastitis for ampicillin (OR=2.18), dry cow treatment for enrofloxacin (OR=2.11) and not sending milk samples for microbiological culture and susceptibility tests, for ampicillin (OR=2.57) and penicillin (OR=4.69). In conclusion, the identification of risk factors for S. aureus resistance against various mastitis antimicrobials is an important information that may help in practical recommendations for prudent use of antimicrobial in milk production.
Resumo:
Self-fluxed nickel alloys are usually flame fused after thermal spraying. However, due to the practical aspects of high temperatures reached during flame fusing, large structures such as the hydraulic turbines for power generation, can not be efficiently coated. An alternative is to fuse the sprayed coating with a gas tungsten electric arc. In this case, heating is much more intensive and substrate temperature during and after the fusing operation is much lower, thus reducing the possibility that any problem will occur. In this work, coatings of self-fluxed nickel alloy fused by flame and gas tungsten arc were evaluated as protection of hydraulic turbines against cavitational damage. Several tests were performed, including the ASTM ultrasonically vibration-induced cavitation, optical and scanning electronic microscopic metallography, and hardness tests. The results showed that the arc-fused coating presented better cavitation damage resistance, probably due to its finer microstructure. A field application of this new technique is also described. A self-fluxed Ni alloy was flame sprayed in critical regions of Francis-type hydraulic turbine blades and fused by a gas tungsten arc after spraying. The blades will be inspected during the next two years.
Resumo:
Communications play a key role in modern smart grids. New functionalities that make the grids ‘smart’ require the communication network to function properly. Data transmission between intelligent electric devices (IEDs) in the rectifier and the customer-end inverters (CEIs) used for power conversion is also required in the smart grid concept of the low-voltage direct current (LVDC) distribution network. Smart grid applications, such as smart metering, demand side management (DSM), and grid protection applied with communications are all installed in the LVDC system. Thus, besides remote connection to the databases of the grid operators, a local communication network in the LVDC network is needed. One solution applied to implement the communication medium in power distribution grids is power line communication (PLC). There are power cables in the distribution grids, and hence, they may be applied as a communication channel for the distribution-level data. This doctoral thesis proposes an IP-based high-frequency (HF) band PLC data transmission concept for the LVDC network. A general method to implement the Ethernet-based PLC concept between the public distribution rectifier and the customerend inverters in the LVDC grid is introduced. Low-voltage cables are studied as the communication channel in the frequency band of 100 kHz–30 MHz. The communication channel characteristics and the noise in the channel are described. All individual components in the channel are presented in detail, and a channel model, comprising models for each channel component is developed and verified by measurements. The channel noise is also studied by measurements. Theoretical signalto- noise ratio (SNR) and channel capacity analyses and practical data transmission tests are carried out to evaluate the applicability of the PLC concept against the requirements set by the smart grid applications in the LVDC system. The main results concerning the applicability of the PLC concept and its limitations are presented, and suggestion for future research proposed.
Resumo:
Varsinais-Suomen ELY-keskuksen toteuttamassa VELHO-hankkeessa kehitettiin kustannustehokkaita ratkaisuja ranta-alueiden umpeenkasvun aiheuttamiin ongelmiin luomalla uusi konsepti ranta-alueiden monikäyttösuunnitteluun, edistämällä järviruo’on hyötykäyttöä ja valmistelemalla esityksiä uuteen maaseudun kehittämisohjelmaan. Tässä julkaisussa esitellään työn tulokset ja johtopäätökset. Hankkeessa laadittiin kolme ranta-alueiden monikäyttösuunnitelmaa: Mynälahden Sarsalanaukko ja Musta-aukko, Oukkulanlahti – Naantalinaukko ja Eurajoen - Luvian rannikko. Suunnitelmissa sovitettiin yhteen ranta-alueiden eri käyttömuotoja ja pyrittiin löytämään optimaalinen verkosto hyötykäyttöön leikattavien ruovikoiden, avoimena pidettävien merenrantaniittyjen ja säilytettävien ruovikoiden välille. Kustannustehokkuuteen pyrittiin kohdentamalla hoitotoimet laajoihin kokonaisuuksiin sekä järviruo’on hyötykäytöllä. Suunnitelmat laadittiin laajassa osallistavassa prosessissa. Hankkeessa laadituissa ranta-alueiden monikäyttösuunnitelmissa esitettiin erilaisia maankäyttötavoitteita ja hoitosuosituksia yli 2000 hehtaarille. Ruovikoiden ja rantaniittyjen lisäksi suunnittelun kohteena olivat myös rantojen läheiset peltoalueet, reunavyöhykkeet ja muut perinnebiotoopit. Hoitotoimilla tavoitellaan alueiden luonnon monimuotoisuuden ja vesien tilan paranemista, maiseman avartumista ja virkistyskäytön helpottumista. Ruovikoiden erilaisia leikkuumenetelmiä (talvileikkuut, vesileikkuut, maaleikkuut) testattiin 90 hehtaarin alalla. Rantaniittyjen kunnostuksessa testattiin maaleikkuun lisäksi ruovikon niittomurskausta. Ruokomassan hyötykäyttökokeissa testattiin kahden eri ruokolaadun eli tuoreen kesäruo’on ja kuivan talviruo’on esikäsittelyä ja hyötykäyttöä energiantuotannossa (poltto, biokaasutus) ja maataloudessa (maanparannusaine, viherlannoite, kuivike, katemateriaali). Maaseudun kehittämisohjelmaan tehtiin esityksiä tukimuotojen kehittämiseksi: rantaniittyjen kunnostuksen lisääminen ja hoidon laadun parantaminen, ruovikoiden vesileikkuut ravinteiden poistajina sekä ruokomassojen käyttö maan orgaanisen aineen lisääjänä. Hankkeen kokemusten mukaan yksi kustannustehokkaimmista hoito- ja käyttöketjuista on ruovikon leikkuu loppukesällä ja siitä kertyvän massan käyttö ranta-alueiden läheisillä pelloilla viherlannoitteena ja maanparannusaineena. Yhden hehtaarin ruovikon kesäleikkuulla poistetaan keskimäärin 80 kg typpeä ja 7 kg fosforia. Vesiensuojelullisten hyötyjen lisäksi leikkuulla parannetaan umpeenkasvusta kärsivien lajien elinoloja, lisätään rantojen vetovoimaisuutta ja edistetään luonnonhoitoyrittäjyyden edellytyksiä. Peltokäytössä käsittelyketju on lyhyt eikä se vaadi pitkiä kuljetusmatkoja. Ruokomassa kierrättää ravinteita takaisin pelloille ja parantaa maan rakennetta. Järviruo’on hyötykäytöllä ei pystytä kattamaan koko leikkuu- ja käyttöketjun kustannuksia. Leikkuusta ja hyötykäytöstä saatavien monien eri aineellisten ja aineettomien ekosysteemipalveluhyötyjen vuoksi toimintaan on tarpeen suunnata yhteiskunnan tukea ja luoda käytännön toteutusta edistäviä tukimuotoja. Kustannustehokkuutta voidaan edelleen parantaa laitteita ja menetelmiä kehittämällä.
Resumo:
Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014
Resumo:
Workshop at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014
Resumo:
Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014
Resumo:
Workshop at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014
Resumo:
Transluminal coronary angioplasty is a routine therapeutic intervention in coronary heart disease. Despite the high rate of primary success, restenosis continues to be its major limitation. Porcine models have been considered to be the most adequate experimental models for studying restenosis. One limitation of porcine models is the need for radiological guidance and the expenses involved. The objective of the present study was to adapt an experimental model of angioplasty in the porcine carotid artery that does not require radiological equipment. Eight animals were used to develop the technique of balloon injury to the common carotid artery by dissection without radiological guidance. This technique was then employed in six other animals. Under anesthesia, the left common carotid artery was dissected and incised at the carotid sinus for insertion of an over-the-wire angioplasty balloon towards the aorta. Overstretch injury of the carotid artery was performed under direct visualization. After 30 days, the arteries were excised and pressure-fixated. Uninjured carotid arteries from 3 additional animals were used as controls. A decreased luminal area associated with intimal hyperplasia and medial reaction was observed in all injured arteries. Immunohistochemistry identified the intimal hyperplastic cells as smooth muscle cells. Computerized morphometry of the ballooned segments revealed the following mean areas: lumen 2.12 mm2 (± 1.09), intima 0.22 mm2 (± 0.08), media 3.47 mm2 (± 0.67), and adventitia 1.11 mm2 (± 0.34). Our experimental model of porcine carotid angioplasty without radiological guidance induced a vascular wall reaction and permitted the quantification of this response. This porcine model may facilitate the study of vascular injury and its response to pharmacological interventions
Resumo:
Static lung volume (LV) measurements have a number of clinical and research applications; however, no previous studies have provided reference values for such tests using a healthy sample of the adult Brazilian population. With this as our main purpose, we prospectively evaluated 100 non-smoking subjects (50 males and 50 females), 20 to 80 years old, randomly selected from more than 8,000 individuals. Gender-specific linear prediction equations were developed by multiple regression analysis with total lung capacity (TLC), functional residual capacity (FRC), residual volume (RV), RV/TLC ratio and inspiratory capacity (IC) as dependent variables, and with age, height, weight, lean body mass and indexes of physical fitness as independent ones. Simpler demographic and anthropometric variables were as useful as more complex measurements in predicting LV values, independent of gender and age (R2 values ranging from 0.49 to 0.78, P<0.001). Interestingly, prediction equations from North American and European studies overestimated the LV at low volumes and underestimated them at high volumes (P<0.05). Our results, therefore, provide a more appropriate frame of reference to evaluate the normalcy of static lung volume values in Brazilian males and females aged 20 to 80 years.