859 resultados para Power quality improvement
Resumo:
Although exposure to secondhand smoke (SHS) is reportedly high in prison, few studies have measured this in the prison environment, and none have done so in Europe. We measured two indicators of SHS exposure (particulate matter PM10 and nicotine) in fixed locations before (2009) and after (2010) introduction of a partial smoking ban in a Swiss prison. Access to smoking cessation support was available to detainees throughout the study. Objectives To measure SHS before and after the introduction of a partial smoking ban. Methods Assessment of particulate matter PM10 (suspended microparticles of 10 μm) and nicotine in ambient air, collected by real-time aerosol monitor and nicotine monitoring devices. Results The authors observed a significant improvement of nicotine concentrations in the air after the introduction of the smoking ban (before: 7.0 μg/m(3), after: 2.1 μg/m(3), difference 4.9 μg/m(3), 95% CI for difference: 0.52 to 9.8, p=0.03) but not in particulate matter PM10 (before: 0.11 mg/m(3), after: 0.06 mg/m(3), difference 0.06 mg/m(3), 95% CI for difference of means: -0.07 to 0.19, p=0.30). Conclusions The partial smoking ban was followed by a decrease in nicotine concentrations in ambient air. These improvements can be attributed to the introduction of the smoking ban since no other policy change occurred during this period. Although this shows that concentrations of SHS decreased significantly, protection was still incomplete and further action is necessary to improve indoor air quality.
Resumo:
Bipolar disorder has a major deleterious impact on many aspects of a patient's functioning and health-related quality of life. Although the formal measurement of these deficits has been neglected until recently, many well-designed trials now include an assessment of functioning and health-related quality of life using one or more rating scales. This review describes recent developments in the measurement of functioning and health-related quality of life in bipolar disorder, and discusses the evidence that medications that improve symptoms in bipolar disorder also offer clinically relevant benefits in functioning and health-related quality of life. Direct comparisons of the benefits of medications including atypical antipsychotics are problematic due to differences in trial populations, study durations and rating scales. Data from quetiapine trials indicate that this medication offers prompt and sustained improvement of functioning in patients with mania and enhancement of health-related quality of life in patients with bipolar depression, to accompany the significant improvements in mood episodes.
Resumo:
Dementia services have moved up the agenda in recent years, highlighted by the publication of the National Dementia Strategy in February 2009. The Health Foundation's improvement report on dementia care hopes to bring together data, research and good practice, with an assessment of the current quality gap.Background to The Health Foundation's Improvement Reports in 2010. At the end of 2009 the Health Foundation agreed a new research and development strategy with the following aims:To make a significant contribution to strengthening the evidence base on how to improve quality in the health care systems of the UK To ensure that this body of knowledge, and a commitment to developing the knowledge shapes our work programmes To promote the use of this evidence base by decision makers at all levels in the health care system Improvement reports will aim to engage the reader by presenting best practice evidence alongside data on current performance and introducing commentary and debate, interpretation about possible next steps and case studies.�� They will build on the success of the chart books produced to date: Bridging the Quality Gap in Stroke services�۪ Quality in healthcare in England, Wales, Scotland, Northern Ireland: an intra-UK chart book�۪, together with Bridging the Quality Gap in Heart Failure�۪ to be published early 2010. Improvement reports will be dynamic and flexible through use of a mix of print products and pages on the Health Foundation�۪s website.
Resumo:
This report provides an overview of the development and field testing of the S�_olta Quality Assurance Programme (QAP). It outlines the timeline, key roles and activities and draws upon evaluation data gathered at various stages of the action research and development process. It briefly describes the processes, tools, materials and the professional roles that have been developed to support implementation of the S�_olta QAP. It concludes with consideration of the context within which the S�_olta QAP will operate into the future and makes a set of recommendations to connect this research and development phase for S�_olta and the S�_olta QAP with national and international policy developments related to the improvement of the quality of early childhood care and education (ecce) in Ireland.
Resumo:
Cytogenetics of triatomines have been a valuable biological tool for the study of evolution, taxonomy, and epidemiology of these vectors of Trypanosoma cruzi. Here we present a single microtube protocol that combines micro-centrifugation and micro-spreading, allowing high quality cytogenetic preparations from male gonadal material of Rhodnius prolixus and Triatoma lecticularia. The amount of cellular scattering can be modulated, which can be useful if small aggregates of synchronous cells are desired. Moreover, a higher number of slides per gonad can be obtained with fully flattened clean chromosomal spreads with minimum overlaps, optimal for classical and modern molecular cytogenetic analyses.
Resumo:
Introduction: Exposure to environmental tobacco smoke (ETS) is a major environmental risk factor. Indoor contaminants come from a variety of sources, which can include inadequate ventilation, volatile organic compounds (VOCs), biological agents, combustion products, and ETS. Because ETS is one of the most frequent causes of IAQ complaints as well as the high mortality of passive smoking, in June 2004 the University of Geneva made the decision to ban smoking inside the so called "Uni-Mail" building, the biggest Swiss University human science building of recent construction, and the ordinance was applied beginning in October 2004. This report presents the finding related to the IAQ of the "Uni-Mail" building before and after smoking bans using nicotine, suspended dust, condensate and PAHs level in air as tracers to perform an assessment of passive tobacco exposure for non-smokers inside the building. Methods: Respirable particles (RSP) A real time aerosol monitor (model DataRAM)was place at sampling post 1, level ground floor. Condensate It consists in extracting any organic matter taken on the glass fibre filters by MeOH, and then measuring the total absorbent of the MeOH extract to the UV wavelength of 447 nm. Nicotine Nicotine was taken by means of cartridges containing of XAD-4 to the fixed flow of 0.5 L/min. The analytical method used for the determination of nicotine is based on gas chromatography with Nitrogen selective detector GC-NPD. Results: Figure 1 shows the box plot density display of 3 parameters before and after smoking bans for all 7 sampling posts: dust, condensate and nicotine in air in μg/m3. Conclusion: Before the smoking ban, the level of the concentrations of respirable particles (RSP) is raised more, average of the day 320 μg/m3, with peaks of more than 1000 μg/m3, compared with the values of the surrounding air between 22 and 30 μg/m3. The nicotine level is definitely more important (average 5.53 μg/m3, field 1.5 to 17.9 μg/m3). Once the smoking bans inside the building were applied, one notes a clear improvement in terms of concentrations of pollutants. For dust, the concentration fell by 3 times (average: 130 μg/m3, range: 40 to 160 μg/m3) and that of nicotine by 10 times (average: 0.53 μg/m3, range: 0 to 1.69 μg/m3) compared to that found before smoking bans. The outdoor air RSP concentration was 22 μg/m3 or 10 times lower. Nicotine seems to be the best tracer for ETS free of interference, independent of location or season.
Resumo:
Background The epidemic of HIV/AIDS and treatments that have emerged to alleviate, have brought about a shift in the burden of disease from death to quality of life/disability. The aim was to determine which factors are associated with improvements in the level of health of male and female patients with HIV/AIDS in Andalusia, in terms of disability-adjusted life years. Methods Descriptive study based on a sample group of 8800 people on the Andalusian AIDS register between 1983 and 2004. Dependent variables: Life lost due to premature mortality (YLL), years lost due to disability (YLD) and disability-adjusted life years (DALY). Independent variables: vital state, sex, age at the time of diagnosis, age at the time of death, transmission category, province of residence, AIDS-indicator disease and the period of diagnosis. A bivariate analysis was carried out to find out if the health level variables changed in accordance with the independent variables. Using the independent variables which had a statistically significant link with the level of health variables, a multivariate linear regression model, disaggregated by gender, was constructed. Results Amongst the women, we found a model which explained the level of health of 64.9%: a link was found between a higher level of health (lower DALYs) and not intravenous drug use, the province of residence, being diagnosed during the HAART era and older age at the time of diagnosis. Amongst the men, we found a model which explained the level of health of 64.4%: a link was found between a higher level of health (lower DALYs) and intravenous drug use, the province of residence, being diagnosed during the HAART era and older age at the time of diagnosis. Conclusion A higher level of health (lower DALY) amongst both men and women was found to be linked to not be intravenous drug user, the province of residence, being diagnosed during the HAART era and older age at the time of diagnosis.
Resumo:
The aim of this validation study was to assess the measurement properties of the CECA (Spanish acronym for the Specific Questionnaire for Condylomata Acuminata) in patients with anogenital condylomas. A total of 247 patients aged > 18 years completed the questionnaire on 2 occasions as well as the Dermatology Life Quality Index (DLQI). The CECA questionnaire showed good internal consistency (Cronbach's alpha values of 0.86 and 0.91 in the emotional and sexual activity dimensions) and good testretest reliability (intraclass correlation coefficient 0.76 emotional dimension, 0.82 sexual activity dimension). Patients with de novo lesions and those with more extensive lesions and larger number of warts showed poorer health-related quality of life. CECA and DLQI scores correlated moderately. Patients whose lesions cleared at follow-up or with a reduction of >or= 50% showed a better improvement of health-related quality of life. The CECA questionnaire is a valid, reliable and sensitive tool for the assessment of health-related quality of life in patients with anogenital warts.
Resumo:
An objective analysis of image quality parameters was performed for a computed radiography (CR) system using both standard single-side and prototype dual-side read plates. The pre-sampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of pediatric chest radiography, at an entrance detector air kerma of 5 microGy. The NPS and DQE measurements were realized under clinically relevant x-ray spectra for pediatric radiology, including x-ray scatter radiations. Compared to the standard single-side read system, the MTF for the dual-side read system is reduced, but this is offset by a significant decrease in image noise, resulting in a marked increase in DQE (+40%) in the low spatial frequency range. Thus, for the same image quality, the new technology permits the CR system to be used at a reduced dose level.
Resumo:
The shape of the energy spectrum produced by an x-ray tube has a great importance in mammography. Many anode-filtration combinations have been proposed to obtain the most effective spectrum shape for the image quality-dose relationship. On the other hand, third generation synchrotrons such as the European Synchrotron Radiation Facility in Grenoble are able to produce a high flux of monoenergetic radiation. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. An objective method was used to evaluate image quality and dose in mammography with synchrotron radiation and to compare them to standard conventional units. It was performed systematically in the energy range of interest for mammography through the evaluation of a global image quality index and through the measurement of the mean glandular dose. Compared to conventional mammography units, synchrotron radiation shows a great improvement of the image quality-dose relationship, which is due to the beam monochromaticity and to the high intrinsic collimation of the beam, which allows the use of a slit instead of an anti-scatter grid for scatter rejection.
Resumo:
Statistics of causes of death remain an important source of epidemiological data for the evaluation of various medical and health problems. The improvement of analytical techniques and, above all, the transformation of demographic and morbid structures of populations have prompted researchers in the field to give more importance to the quality of death certificates. After describing the data collection system presently used in Switzerland, the paper discusses various indirect estimations of the quality of Swiss data and reviews the corresponding international literature.
Resumo:
This paper aims to survey the techniques and methods described in literature to analyse and characterise voltage sags and the corresponding objectives of these works. The study has been performed from a data mining point of view
Resumo:
ABSTRACT We propose a model to explain how contract terms are selected in the presence of a form of economic power: contract power. The orange juice sector is used to illustrate an analysis that demonstrates the effects of contract power on the economic organization of the sector. We define contract power as the ability to exploit contractual gaps or failures of contractual provisions, which are strategically left incomplete. Empirical evidence from content analysis of antitrust documents supports the logic of contract power in the orange juice sector in three forms: avoiding changes to payment methods from weight to solid contents (quality); using information asymmetries to manipulate indexes that calculate the formula of orange prices; and deliberately harvesting oranges late in order to dehydrate the fruit, which consequently reduces weight and price. The paper contributes to understanding the selection of contract terms and the debate about how antitrust offices can deal with this issue.
Resumo:
BACKGROUND: In the United States, the Agency for Healthcare Research and Quality (AHRQ) has developed 20 Patient Safety Indicators (PSIs) to measure the occurrence of hospital adverse events from medico-administrative data coded according to the ninth revision of the international classification of disease (ICD-9-CM). The adaptation of these PSIs to the WHO version of ICD-10 was carried out by an international consortium. METHODS: Two independent teams transcoded ICD-9-CM diagnosis codes proposed by the AHRQ into ICD-10-WHO. Using a Delphi process, experts from six countries evaluated each code independently, stating whether it was "included", "excluded" or "uncertain". During a two-day meeting, the experts then discussed the codes that had not obtained a consensus, and the additional codes proposed. RESULTS: Fifteen PSIs were adapted. Among the 2569 proposed diagnosis codes, 1775 were unanimously adopted straightaway. The 794 remaining codes and 2541 additional codes were discussed. Three documents were prepared: (1) a list of ICD-10-WHO codes for the 15 adapted PSIs; (2) recommendations to the AHRQ for the improvement of the nosological frame and the coding of PSI with ICD-9-CM; (3) recommendations to the WHO to improve ICD-10. CONCLUSIONS: This work allows international comparisons of PSIs among the countries using ICD-10. Nevertheless, these PSIs must still be evaluated further before being broadly used.
Resumo:
In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.