896 resultados para Porous filters
Resumo:
This paper presents a low complexity high efficiency decimation filter which can be employed in EletroCardioGram (ECG) acquisition systems. The decimation filter with a decimation ratio of 128 works along with a third order sigma delta modulator. It is designed in four stages to reduce cost and power consumption. The work reported here provides an efficient approach for the decimation process for high resolution biomedical data conversion applications by employing low complexity two-path all-pass based decimation filters. The performance of the proposed decimation chain was validated by using the MIT-BIH arrhythmia database and comparative simulations were conducted with the state of the art.
Resumo:
The present study aimed to develop a pre-endothelialized chitosan (CH) porous hollowed scaffold for application in spinal cord regenerative therapies. CH conduits with different degrees of acetylation (DA; 4% and 15%) were prepared, characterized (microstructure, porosity and water uptake) and functionalized with a recombinant fragment of human fibronectin (rhFNIII7–10). Immobilized rhFNIII7–10 was characterized in terms of amount (125I-radiolabelling), exposure of cell-binding domains (immunofluorescence) and ability to mediate endothelial cell (EC) adhesion and cytoskeletal rearrangement. Functionalized conduits revealed a linear increase in immobilized rhFNIII7–10 with rhFNIII7–10 concentration, and, for the same concentration, higher amounts of rhFNIII7–10 on DA 4% compared with DA 15%. Moreover, rhFNIII7–10 concentrations as low as 5 and 20 lgml 1 in the coupling reaction were shown to provide DA 4% and 15% scaffolds, respectively, with levels of exposed cell-binding domains exceeding those observed on the control (DA 4% scaffolds incubated in a 20 lgml 1 human fibronectin solution). These grafting conditions proved to be effective in mediating EC adhesion/cytoskeletal organization on CH with DA 4% and 15%, without affecting the endothelial angiogenic potential. rhFNIII7–10 grafting to CH could be a strategy of particular interest in tissue engineering applications requiring the use of endothelialized porous matrices with tunable degradation rates.
Resumo:
Constrained nonlinear optimization problems are usually solved using penalty or barrier methods combined with unconstrained optimization methods. Another alternative used to solve constrained nonlinear optimization problems is the lters method. Filters method, introduced by Fletcher and Ley er in 2002, have been widely used in several areas of constrained nonlinear optimization. These methods treat optimization problem as bi-objective attempts to minimize the objective function and a continuous function that aggregates the constraint violation functions. Audet and Dennis have presented the rst lters method for derivative-free nonlinear programming, based on pattern search methods. Motivated by this work we have de- veloped a new direct search method, based on simplex methods, for general constrained optimization, that combines the features of the simplex method and lters method. This work presents a new variant of these methods which combines the lters method with other direct search methods and are proposed some alternatives to aggregate the constraint violation functions.
Resumo:
The aim of this study is to evaluate lighting conditions and speleologists’ visual performance using optical filters when exposed to the lighting conditions of cave environments. A crosssectional study was conducted. Twenty-three speleologists were submitted to an evaluation of visual function in a clinical lab. An examination of visual acuity, contrast sensitivity, stereoacuity and flashlight illuminance levels was also performed in 16 of the 23 speleologists at two caves deprived of natural lightning. Two organic filters (450 nm and 550 nm) were used to compare visual function with and without filters. The mean age of the speleologists was 40.65 (± 10.93) years. We detected 26.1% participants with visual impairment of which refractive error (17.4%) was the major cause. In the cave environment the majority of the speleologists used a head flashlight with a mean illuminance of 451.0 ± 305.7 lux. Binocular visual acuity (BVA) was -0.05 ± 0.15 LogMAR (20/18). BVA for distance without filter was not statistically different from BVA with 550 nm or 450 nm filters (p = 0.093). Significant improved contrast sensitivity was observed with 450 nm filters for 6 cpd (p = 0.034) and 18 cpd (p = 0.026) spatial frequencies. There were no signs and symptoms of visual pathologies related to cave exposure. Illuminance levels were adequate to the majority of the activities performed. The enhancement in contrast sensitivity with filters could potentially improve tasks related with the activities performed in the cave.
Resumo:
Thesis submitted to Faculdade de Ciências e Tecnologia from Universidade Nova de Lisboa in partial fulfillment of the requirements for the obtention of the degree of Master of Science in Biotechnology
Resumo:
Potential risks of a secondary formation of polychlorinated dibenzodioxins/furans (PCDD/Fs) were assessed for two cordierite-based, wall-through diesel particulate filters (DPFs) for which soot combustion was either catalyzed with an iron- or a copper-based fuel additive. A heavy duty diesel engine was used as test platform, applying the eight-stage ISO 8178/4 C1 cycle. DPF applications neither affected the engine performance, nor did they increase NO, NO2, CO, and CO2 emissions. The latter is a metric for fuel consumption. THC emissions decreased by about 40% when deploying DPFs. PCDD/F emissions, with a focus on tetra- to octachlorinated congeners, were compared under standard and worst case conditions (enhanced chlorine uptake). The iron-catalyzed DPF neither increased PCDD/F emissions, nor did it change the congener pattern, even when traces of chlorine became available. In case of copper, PCDD/F emissions increased by up to 3 orders of magnitude from 22 to 200 to 12 700 pg I-TEQ/L with fuels of < 2, 14, and 110 microg/g chlorine, respectively. Mainly lower chlorinated DD/Fs were formed. Based on these substantial effects on PCDD/F emissions, the copper-catalyzed DPF system was not approved for workplace applications, whereas the iron system fulfilled all the specifications of the Swiss procedures for DPF approval (VERT).
Resumo:
The advent of retrievable caval filters was a game changer in the sense, that the previously irreversible act of implanting a medical device into the main venous blood stream of the body requiring careful evaluation of the pros and cons prior to execution suddenly became a "reversible" procedure where potential hazards in the late future of the patient lost most of their weight at the time of decision making. This review was designed to assess the rate of success with late retrieval of so called retrievable caval filters in order to get some indication about reasonable implant duration with respect to relatively "easy" implant removal with conventional means, i.e., catheters, hooks and lassos. A PubMed search (www.pubmed.gov) was performed with the search term "cava filter retrieval after 30 days clinical", and 20 reports between 1994 and 2013 dealing with late retrieval of caval filters were identified, covering approximately 7,000 devices with 600 removed filters. The maximal duration of implant reported is 2,599 days and the maximal implant duration of removed filters is also 2,599 days. The maximal duration reported with standard retrieval techniques, i.e., catheter, hook and/or lasso, is 475 days, whereas for the retrievals after this period more sophisticated techniques including lasers, etc. were required. The maximal implant duration for series with 100% retrieval accounts for 84 days, which is equivalent to 12 weeks or almost 3 months. We conclude that retrievable caval filters often become permanent despite the initial decision of temporary use. However, such "forgotten" retrievable devices can still be removed with a great chance of success up to three months after implantation. Conventional percutaneous removal techniques may be sufficient up to sixteen months after implantation whereas more sophisticated catheter techniques have been shown to be successful up to 83 months or more than seven years of implant duration. Tilting, migrating, or misplaced devices should be removed early on, and replaced if indicated with a device which is both, efficient and retrievable.
Resumo:
Tesis (Doctor en Ingeniería Eléctrica) UANL, 2011.
Resumo:
In a seminal contribution, Hansson (1976) demonstrates that the collection of decisive coalitions associated with an Arrovian social welfare function forms an ultrafilter. He goes on to show that if transitivity is weakened to quasi-transitivity as the coherence property imposed on a social relation, the set of decisive coalitions is a filter. We examine the notion of decisiveness with acyclical or Suzumura consistent social preferences and without assuming that the social relation is complete. This leads to a new set-theoretic concept applied to product spaces.
Resumo:
Objectives In April 2010, the Université de Montréal’s Health Sciences Library has implemented shared filters in its institutional PubMed account. Most of these filters are designed to highlight resources for evidence-based practice, such as Clinical Queries, Systematic Reviews and Evidence-based Synopsis. We now want to measure how those filters are perceived and used by our users. Methods For one month, data was gathered through an online questionnaire proposed to users of Université de Montréal’s PubMed account. A print version was also distributed to participants in information literacy workshops given by the health sciences librarians. Respondents were restricted to users affiliated to Université de Montréal’s faculties of Medicine, Dentistry, Veterinary Sciences, Nursing and Pharmacy. Basic user information such as year/program of study or department affiliation was also collected. The questionnaire allowed users to identify the filters they use, assess the relevance of filters, and also suggest new ones. Results Survey results showed that the shared filters of Université de Montreal’s PubMed account were found useful by the majority of respondents. Filters allowing rapid access to secondary resources ranked among the most relevant (Reviews, Systematic Reviews, Cochrane Database of Systematic Reviews, Practice Guidelines and Clinical Evidence). For Clinical Study Queries, Randomized Controlled Trial (Therapy/Narrow) was considered the most useful. Some new shared filters have been suggested by respondents. Finally, 18% of the respondents indicated that they did not quite understand the relevance of filters. Conclusion Based on the survey results, shared filters considered most useful will be kept, some will be enhanced and others removed so that suggested ones could be added. The fact that some respondents did not understand well the relevance of filters could potentially be addressed through our PubMed workshops, online library guides or by renaming some filters in a more meaningful way.
Resumo:
Les tests PAMPA et les tests Caco-2 sont des essais in vitro de l’évaluation de la perméabilité intestinale des médicaments. Ils sont réalisés lors de la phase de découverte du médicament. Les tests PAMPA ne sont pas biologiquement représentatifs de la paroi intestinale, mais ils sont rapides et peu coûteux. Les tests Caco-2 nécessitent plus de 21 jours pour la culture cellulaire et des installations spécifiques sont requises. Ils sont constitués d’une monocouche d’entérocytes à confluence et donc plus biologiquement représentatifs. Il y a un besoin pour le développement d’un essai qui est biologiquement représentatif de la membrane intestinale humaine, rapide et peu coûteux. Le premier but de ce projet était de développer une méthode analytique qui permettrait l’évaluation simultanée de huit médicaments témoins utilisés pour la validation de l’essai de perméabilité. Le deuxième but de ce projet était donc d’améliorer la membrane des tests PAMPA pour proposer un nouveau test : le néoPAMPA. Contrairement au test PAMPA traditionnel, cette membrane est constituée de trois composantes : (1) un filtre poreux qui agit à titre de support, (2) un coussin polydopamine chargé négativement qui sert d’ancrage et qui assure la fluidité de la bicouche et (3) une bicouche lipidique formée par fusion de vésicules. Une méthode analytique HPLC-MS/MS a été validée selon les spécifications de la FDA et de la EMA. Cette méthode a permis de quantifier simultanément les huit médicaments standards utilisés pour le test néoPAMPA. Le test PAMPA traditionnel a été mis en place à titre d’essai control. Les coefficients de perméabilité mesurés pour les huit médicaments au travers de la membrane PAMPA comparaient favorablement aux résultats de la littérature. Les composantes de la membrane néoPAMPA ont été optimisées. Les conditions optimales retenues étaient les filtres de polycarbonate hydrophile ayant des pores de 15 nm, les plaques Costar 12 puits comme dispositif des tests de perméabilité, une bicouche lipidique composée de 70 % DOPC et de 30 % cholestérol cationique ainsi qu’une déposition des liposomes en présence de 150 mM NaCl suivi d’un équilibre d’1 h en présence d’une solution saturée en DOPC. Les stabilités de la cassette de médicaments et des liposomes sont insuffisantes pour le conditionnement commercial des membranes néoPAMPA. Les différentes optimisations réalisées ont permis d’améliorer la membrane néoPAMPA sans toutefois la rendre fonctionnelle. La membrane néoPAMPA n’est toujours pas en mesure de discriminer des molécules en fonction de leur perméabilité attendue.
Resumo:
The laser induced non-destructive photoacoustic technique has been employed to measure the thermal diffusivity of lanthanum phosphate ceramics prepared by the sol–gel route. The thermal diffusivity value was evaluated by knowing the transition frequency between the thermally thin to thermally thick region from the log–log plot of photoacoustic amplitude versus chopping frequency. Analysis of the data was carried out on the basis of the one-dimensional model of Rosencwaig and Gersho. The present investigation reveals that the sintering temperature has great influence on the propagation of heat carriers and hence on the thermal diffusivity value. The results were interpreted in terms of variations in porosity with sintering temperature as well as with changes in grain size.
Resumo:
A laser-induced photoacoustic technique was employed to investigate thermal transport through nanocrystalline CePO4 samples prepared via the sol–gel route. Evaluation of thermal diffusivity was carried out using the one-dimensional model of Rosencwaig and Gersho for the reflection configuration of the photoacoustic method. Structural analyses of samples revealed that they are nanoporous in nature, possessing micron-sized grains. Analysis of results shows that thermal diffusivity value varies with sintering temperature. Results are explained in terms of the variation in porosity with sintering temperature and the effects of various scattering mechanisms on the propagation of phonons through the nanoporous ceramic matrix. Further analyses confirm that apart from porosity, grain boundary resistance and interface thermal resistance influence the effective value of thermal diffusivity of the samples under investigation.