920 resultados para Platinum surfaces
Resumo:
In this paper we present a hybrid technique for correcting distortions that appear when projecting images onto geometrically complex, colored and textured surfaces. It analyzes the optical flow that results from perspective distortions during motions of the observer and tries to use this information for computing the correct image warping. If this fails due to an unreliable optical flow, an accurate -but slower and visiblestructured light projection is automatically triggered. Together with an appropriate radiometric compensation, view-dependent content can be projected onto arbitrary everyday surfaces. An implementation mainly on the GPU ensures fast frame rates.
Resumo:
Transparent and translucent objects involve both light reflection and transmission at surfaces. This paper presents a physically based transmission model of rough surface. The surface is assumed to be locally smooth, and statistical techniques is applied to calculate light transmission through a local illumination area. We have obtained an analytical expression for single scattering. The analytical model has been compared to our Monte Carlo simulations as well as to the previous simulations, and good agreements have been achieved. The presented model has potential applications for realistic rendering of transparent and translucent objects.
Resumo:
We have studied Au(55 nm)@SiO2 nanoparticles (NPs) on two low-index phases of gold and platinum single crystal electrodes in ClO4– and SO42– ion-containing electrolytes by both electrochemical methods and in-situ shell-isolated nanoparticle enhanced Raman spectroscopy (SHINERS). We showed the blocking of the electrode with surfactants originating from the synthesis of as-prepared SHINERS NPs. We introduce an efficient procedure to overcome this problem, which provides a fundamental platform for the application of SHINERS in surface electrochemistry and beyond. Our method is based on a hydrogen evolution treatment of the SHINERS-NP-modified single-crystal surfaces. The reliability of our preparation strategy is demonstrated in electrochemical SHINERS experiments on the potential-controlled adsorption and phase formation of pyridine on Au(hkl) and Pt(hkl). We obtained high-quality Raman spectra on these well-defined and structurally carefully characterized single-crystal surfaces. The analysis of the characteristic A1 vibrational modes revealed perfect agreement with the interpretation of single-crystal voltammetric and chronoamperometric experiments. Our study demonstrates that the SHINERS protocol developed in this work qualifies this Raman method as a pioneering approach with unique opportunities for in situ structure and reactivity studies at well-defined electrochemical solid/liquid interfaces.
Resumo:
The extents of functional surfaces (villi, microvilli) have been estimated at different longitudinal sites, and in the entire small intestine, for three species of bats belonging to two feeding groups: insect- and fruit-eaters. In all species, surface areas and other structural quantities tended to be greatest at more cranial sites and to decline caudally. The entomophagous bat (Miniopterus inflatus) had a mean body mass (coefficient of variation) of 8.9 g (5%) and a mean intestinal length of 20 cm (6%). The surface area of the basic intestinal tube (primary mucosa) was 9.1 cm2 (10%) but this was amplified to 48 cm2 (13%) by villi and to 0.13 m2 (20%) by microvilli. The total number of microvilli per intestine was 4 x 10(11) (20%). The average microvillus had a diameter of 8 nm (10%), a length of 1.1 microns (22%) and a membrane surface area of 0.32 micron 2 (31%). In two species of fruit bats (Epomophorus wahlbergi and Lisonycteris angolensis), body masses were greater and intestines longer, the values being 76.0 g (18%) and 76.9 g (4%), and 73 cm (16%) and 72 cm (7%), respectively. Surface areas were also greater, amounting to 76 cm2 (26%) and 45 cm2 (8%) for the primary mucosa, 547 cm2 (29%) and 314 cm2 (16%) for villi and 2.7 m2 (23%) and 1.5 m2 (18%) for microvilli. An increase in the number of microvilli, 33 x 10(11) (19%) and 15 x 10(11) (24%) per intestine, contributed to the more extensive surface area but there were concomitant changes in the dimensions of microvilli. Mean diameters were 94 nm (8%) and 111 nm (4%), and mean lengths were 2.8 microns (12%) and 2.9 microns (10%), respectively. Thus, an increase in the surface area of the average microvillus to 0.83 micron 2 (12%) and 1.02 microns 2 (11%) also contributed to the greater total surface area of microvilli. The lifestyle-related differences in total microvillous surface areas persisted when structural quantities were normalised for the differences in body masses. The values for total microvillous surface area were 148 cm2g-1 (20%) in the entomophagous bat, 355 cm2g-1 (20%) in E. wahlbergi and 192 cm2g-1 (17%) in L. angolensis. This was true despite the fact that the insecteater possessed a greater length of intestine per unit of body mass: 22 mm g-1 (8%) versus 9-10 mm g-1 (9-10%) for the fruit-eaters.
Resumo:
To assess the prevalence of tooth wear on buccal/facial and lingual/palatal tooth surfaces and identify related risk factors in a sample of young European adults, aged 18-35 years. Calibrated and trained examiners measured tooth wear, using the basic erosive wear examination (BEWE) on in 3187 patients in seven European countries and assessed the impact of risk factors with a previously validated questionnaire. Each individual was characterized by the highest BEWE score recorded for any scoreable surface. Bivariate analyses examined the proportion of participants who scored 2 or 3 in relation to a range of demographic, dietary and oral care variables. The highest tooth wear BEWE score was 0 for 1368 patients (42.9%), 1 for 883 (27.7%), 2 for 831 (26.1%) and 3 for 105 (3.3%). There were large differences between different countries with the highest levels of tooth wear observed in the UK. Important risk factors for tooth wear included heartburn or acid reflux, repeated vomiting, residence in rural areas, electric tooth brushing and snoring. We found no evidence that waiting after breakfast before tooth brushing has any effect on the degree of tooth wear (p=0.088). Fresh fruit and juice intake was positively associated with tooth wear. In this adult sample 29% had signs of tooth wear making it a common presenting feature in European adults.
Resumo:
The adsorption interactions of thallium and its compounds with gold and quartz surfaces were investigated. Carrier-free amounts of thallium were produced in nuclear fusion reactions of alpha particles with thick gold targets. The method chosen for the studies was gas thermochromatography and varying the redox potential of the carrier gases. It was observed that thallium is extremely sensitive to trace amounts of oxygen and water, and can even be oxidized by the hydroxyl groups located on the quartz surface. The experiments on a quartz surface with O2, He, H2 gas in addition with water revealed the formation and deposition of only one thallium species – TlOH. The adsorption enthalpy was determined to be Δ HSiO2ads(TlOH) = −134 ± 5 kJ mol−1. A series of experiments using gold as stationary surface and different carrier gases resulted in the detection of two thallium species – metallic Tl (H2 as carrier gas) and TlOH (O2, O2+H2O and H2+H2O as pure carrier gas or carrier gas mixture) with Δ HAuads(Tl) = −270 ± 10 kJ mol− and Δ HAuads(TlOH) = −146 ± 3 kJ mol−1. These data demonstrate a weak interaction of TlOH with both quartz and gold surfaces. The data represent important information for the design of future experiments with the heavier homologue of Tl in group 13 of the periodic table – element 113 (E113).
Resumo:
We present 3-D simulations of impacts into Asteroid 21 Lutetia, the subject of a fly-by by the European Space Agency's Rosetta mission to Comet 67P/Churyumov-Gerasimenko. Using a 3-D shape model of the asteroid, impacts of sizes sufficient to reproduce the observed craters in Lutetia's North Polar Crater Cluster (NPCC) as observed by the OSIRIS experiment have been simulated using the Smoothed Particle Hydrodynamics technique. The asteroid itself has been modelled both as a homogeneous body and as a body with an iron core.
Resumo:
BACKGROUND: Arginine metabolism in tumor cell lines can be influenced by various cytokines, including recombinant human interferon-gamma (rIFN-gamma), a cytokine that shows promising clinical activity in epithelial ovarian cancer (EOC). METHODS: We examined EOC cell lines for the expression of arginase in an enzymatic assay and for transcripts of arginase I and II, inducible nitric oxide synthase (iNOS), and indoleamine 2,3-dioxygenase (IDO) by reverse transcription-polymerase chain reaction. The effects of rIFN-gamma on arginase activity and on tumor cell growth inhibition were determined by measuring [3H]thymidine uptake. RESULTS: Elevated arginase activity was detected in 5 of 8 tumor cell lines, and analysis at the transcriptional level showed that arginase II was involved but arginase I was not. rIFN-gamma reduced arginase activity in 3 EOC cell lines but increased activity in the 2008 cell line and its platinum-resistant subline, 2008.C13. iNOS transcripts were not detected in rIFN-gamma-treated or untreated cell lines. In contrast, IDO activity was induced or increased by rIFN-gamma. Suppression of arginase activity by rIFN-gamma in certain cell lines suggested that such inhibition might contribute to its antiproliferative effects. However, supplementation of the medium with polyamine pathway products did not interfere with the growth-inhibitory effects of rIFN-gamma EOC cells. CONCLUSIONS: Increased arginase activity, specifically identified with arginase II, is present in most of the tested EOC cell lines. rIFN-gamma inhibits or stimulates arginase activity in certain EOC cell lines, though the decrease in arginase activity does not appear to be associated with the in vitro antiproliferative activity of rIFN-gamma. Since cells within the stroma of EOC tissues could also contribute to arginine metabolism following treatment with rIFN-gamma or rIFN-gamma-inducers, it would be helpful to examine these effects in vivo.
Resumo:
The emerging application of long-term and high-quality ECG recording requires alternative electrodes to improve the signal quality and recording capability of surface skin electrodes. The esophageal ECG has the potential to overcome these limitations but necessitates novel recorder and lead designs. The electrode material is of particular interest, since the material has to ensure conflicting requirements like excellent biopotential recording properties and inertness. To this end, novel electrode materials like PEDOT and silver-PDMS as well as established electrode materials such as stainless steel, platinum, gold, iridium oxide, titanium nitride, and glassy carbon were investigated by long-term electrochemical impedance spectroscopy and model-based signal analysis using the derived in vitro interfacial properties in conjunction with a dedicated ECG amplifier. The results of this novel approach show that titanium nitride and iridium oxide featuring microstructured surfaces did not degrade when exposed to artificial acidic saliva. These materials provide low electrode potential drifts and insignificant signal distortion superior to surface skin electrodes making them compatible with accepted standards for ambulatory ECG. They are superior to the noble and polarizable metals such as platinum, silver, and gold that induced more signal distortions and are superior to esophageal stainless steel electrodes that corrode in artificial saliva. The study provides rigorous criteria for the selection of electrode materials for prolonged ECG recording by combining long-term in vitro electrode material properties with ECG signal quality assessment.
Resumo:
Two polycrystalline diamond surfaces, manufactured by chemical vapour deposition (CVD) technique, are investigated regarding their applicability as charge state conversion surfaces (CS) for use in a low energy neutral atom imaging instrument in space research. The capability of the surfaces for converting neutral atoms into negative ions via surface ionisation processes was measured for hydrogen and oxygen with particle energies in the range from 100 eV to 1 keV and for angles of incidence between 6 deg and 15 deg. We observed surface charging during the surface ionisation processes for one of the CVD samples due to low electrical conductivity of the material. Measurements on the other CVD diamond sample resulted in ionisation efficiencies of ~2 % for H and up to 12 % for O. Analysis of the angular scattering revealed very narrow and almost circular scattering distributions. Comparison of the results with the data of the CS of the IBEX-Lo sensor shows that CVD diamond has great potential as CS material for future space missions.