997 resultados para Optical frequency combs
Resumo:
In this paper we present some result on sol-gel derived silica-hafnia systems. In particular we focus on fabrication, morphological and spectroscopic assessment of Er(3+)-activated thin films. Two examples of silica-hafnia-derived waveguiding glass ceramics, prepared by top-down and bottom-up techniques are reported, and the main optical properties are discussed. Finally, some properties of activated microspherical resonators, having a silica core, obtained by melting the end of a telecom fiber, coated with an Er(3+)-doped 70SiO(2)-30HfO(2) film, are presented. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
We investigated three amino derivatives of ortho-aminobenzoic or anthranilic acid (o-Abz): a) 2-Amino-benzamide (AbzNH(2)); b) 2-Amino-N-methyl-benzamide (AbzNHCH(3)) and c) 2-Amino-N-N`-dimethyl-bezamide (AbzNH(CH(3))(2)), see Scheme 1. We describe the results of ab-initio calculations on the structural characteristics of the compounds and experimental studies about solvent effects in their absorption and steady-state and time-resolved emission properties. Ab-initio calculations showed higher stability for the rotameric conformation in which the oxygen of carbonyl is near to the nitrogen of ortho-amino group. The derivatives present decrease in the delocalization of pi electron, and absorption bands are blue shifted compared to the parent compound absorption, the extent of the effect increasing from to Abz-NH(2) to Abz-NHCH(3) Abz-NH(CH(3))(2). Measurements performed in several solvents have shown that the the dependence of Stokes shift of the derivatives with the orientational polarizability follows the Onsager-Lippert model for general effects of solvent. However deviation occurred in solvents with properties of Bronsted acids, or electron acceptor characteristics, so that hydrogen bonds formed with protic solvents predominates over intramolecular hydrogen bond. In most solvents the fluorescence decay of AbzNH(2) and AbzNHCH(3) was fitted to a single exponential with lifetimes around 7.0 ns and no correlation with polarity of the solvent was observed. The fluorescence decay of AbzN(CH(3))(2) showed lifetimes around 2.0 ns, consistent with low quantum yield of the compound. The spectroscopic properties of the monoamino derivative AbzNHCH(3) are representative of the properties presented by Abz labelled peptides and fatty acids previously studied.
Resumo:
This paper reports an investigation on techniques for determining elastic modulus and intrinsic stress gradient in plasma-enhanced chemical vapor deposition (PECVD) silicon nitride thin films. The elastic property of the silicon nitride thin films was determined using the nanoindentation method on silicon nitride/silicon bilayer systems. A simple empirical formula was developed to deconvolute the film elastic modulus. The intrinsic stress gradient in the films was determined by using micrometric cantilever beams, cross-membrane structures and mechanical simulation. The deflections of the silicon nitride thin film cantilever beams and cross-membranes caused by in-thickness stress gradients were measured using optical interference microscopy. Finite-element beam models were built to compute the deflection induced by the stress gradient. Matching the deflection computed under a given gradient with that measured experimentally on fabricated samples allows the stress gradient of the PECVD silicon nitride thin films introduced from the fabrication process to be evaluated.
Resumo:
We present a controlled stress microviscometer with applications to complex fluids. It generates and measures microscopic fluid velocity fields, based on dual beam optical tweezers. This allows an investigation of bulk viscous properties and local inhomogeneities at the probe particle surface. The accuracy of the method is demonstrated in water. In a complex fluid model (hyaluronic acid), we observe a strong deviation of the flow field from classical behavior. Knowledge of the deviation together with an optical torque measurement is used to determine the bulk viscosity. Furthermore, we model the observed deviation and derive microscopic parameters.
Resumo:
In this paper we study the nondegenerate optical parametric oscillator with injected signal, both analytically and numerically. We develop a perturbation approach which allows us to find approximate analytical solutions, starting from the full equations of motion in the positive-P representation. We demonstrate the regimes of validity of our approximations via comparison with the full stochastic results. We find that, with reasonably low levels of injected signal, the system allows for demonstrations of quantum entanglement and the Einstein-Podolsky-Rosen paradox. In contrast to the normal optical parametric oscillator operating below threshold, these features are demonstrated with relatively intense fields.
Resumo:
Vagal Denervation and Neurally Mediated Syncope. A 15-year-old female patient presented with frequent episodes of vasovagal syncope refractory to non-pharmacological and pharmacological measures. Two tilt-table tests performed before and after conventional therapy were positive and reproduced the patient`s clinical symptoms. Selective vagal denervation, guided by HFS, was performed. Six radiofrequency pulses were applied on the left and right sides of the interatrial septum, abolishing vagal responses at these locations. Basal sinus node and Wenckebach cycle lengths changed significantly following ablation. A tilt test performed after denervation was negative and revealed autonomic tone modification. The patient reported significant improvement in quality of life and remained asymptomatic for 9 months after denervation. After this period, three episodes of NMS occurred during a 4-month interval and a tilt test performed 11 months after the procedure demonstrated vagal activity recovery. (J Cardiovasc Electrophysiol, Vol. 20, pp. 558-563, May 2009).
Resumo:
PURPOSE: To determine whether implantation of an intraocular lens (IOL) with an aspheric surface (Akreos AO, Bausch & Lomb Inc) results in reduced ocular aberrations (spherical aberration) and improved Strehl ratio and modulation transfer function (MTF) after cataract surgery. METHODS: In an intraindividual, randomized, double-masked, prospective study of 50 eyes (25 patients) with bilateral cataract, an IOL with modified anterior and posterior surfaces (Akreos AO) was implanted in one eye and a biconvex IOL with spherical surfaces (Akreos Fit, Bausch & Lomb Inc) implanted in the fellow eye. Ocular aberrations, Strehl ratio, and MTF curve with 4.5-, 5.0-, and 6.0-mm pupils were measured with a NIDEK OPD-Scan dynamic retinoscopy aberrometer 3 months after surgery. Uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) were also measured. RESULTS: No statistically significant difference was noted between eyes in postoperative UDVA and CDVA at 1 month. At 3 months, the Akreos AO IOL group obtained statistically significant lower values of higher order and spherical aberrations with 4.5-, 5.0-, and 6.0-mm pupil diameters than the Akreos Fit IOL group (P<.05). The value of Strehl ratio was statistically significantly higher in eyes with the Akreos AO IOL for 4.5- and 6.0-mm pupils (P<.05). The MTF curve was better in the Akreos AO IOL group in 4.5-, 5.0-, and 6.0-mm pupils (P<.05). CONCLUSIONS: The aspheric Akreos AO IOL induced significantly less spherical aberration than the Akreos Fit IOL for 4.5-, 5.0-, and 6.0-mm pupils. Modulation transfer function and Strehl ratio were also better in eyes implanted with the Akreos AO IOL than the Akreos Fit. [J Refract Surg. 2011;27(4):287-292.] doi:10.3928/1081597X-20100714-01
Resumo:
This study analyzed the genotype distribution and frequency of lamivudine (LAM) and tenofovir (TDF) resistance mutations in a group of patients co-infected with HIV and hepatitis B virus (HBV). A cross-sectional study of 847 patients with HIV was conducted. Patients provided blood samples for HBsAg detection. The load of HBV was determined using an ""in-house"" real-time polymerase chain reaction. HBV genotypes/subgenotypes, antiviral resistance, basal core promoter (BCP), and precore mutations were detected by DNA sequencing. Twenty-eight patients with co-infection were identified. The distribution of HBV genotypes among these patients was A (n = 9; 50%), D (n = 4; 22.2%), G (n = 3; 16.7%), and F (n = 2; 11.1%). Eighteen patients were treated with LAM and six patients were treated with LAM plus TDF. The length of exposure to LAM and TDF varied from 4 to 216 months. LAM resistance substitutions (rtL180M + rtM204V) were detected in 10 (50%) of the 20 patients with viremia. This pattern and an accompanying rtV173L mutation was found in four patients. Three patients with the triple polymerase substitution pattern (rtV173L+ rtL180M + rtM204V) had associated changes in the envelope gene (sE164D + sl195M). Mutations in the BCP region (A1762T, G1764A) and in the precore region (G1896A, G1899A) were also found. No putative TDF resistance substitution was detected. The data suggest that prolonged LAM use is associated with the emergence of particular changes in the HBV genome, including substitutions that may elicit a vaccine escape phenotype. No putative TDF resistance change was detected after prolonged use of TDF. J. Med. Virol. 82:1481-1488, 2010. (C) 2010 Wiley-Liss, Inc.
Resumo:
The technical reliability (i.e., interinstrument and interoperator reliability) of three SEAC-swept frequency bioimpedance monitors was assessed for both errors of measurement and associated analyses. In addition, intraoperator and intrainstrument variability was evaluated for repeat measures over a 4-hour period. The measured impedance values from a range of resistance-capacitance circuits were accurate to within 3% of theoretical values over a range of 50-800 ohms. Similarly, phase was measured over the range 1 degrees-19 degrees with a maximum deviation of 1.3 degrees from the theoretical value. The extrapolated impedance at zero frequency was equally well determined (+/-3%). However, the accuracy of the extrapolated value at infinite frequency was decreased, particularly at impedances below 50 ohms (approaching the lower limit of the measurement range of the instrument). The interinstrument/operator variation for whole body measurements were recorded on human volunteers with biases of less than +/-1% for measured impedance values and less than 3% for phase. The variation in the extrapolated values of impedance at zero and infinite frequencies included variations due to operator choice of the analysis parameters but was still less than +/-0.5%. (C) 1997 Wiley-Liss, Inc.
Resumo:
The acceptance-probability-controlled simulated annealing with an adaptive move generation procedure, an optimization technique derived from the simulated annealing algorithm, is presented. The adaptive move generation procedure was compared against the random move generation procedure on seven multiminima test functions, as well as on the synthetic data, resembling the optical constants of a metal. In all cases the algorithm proved to have faster convergence and superior escaping from local minima. This algorithm was then applied to fit the model dielectric function to data for platinum and aluminum.
Resumo:
We report the observation of the quantum effects of competing chi((2)) nonlinearities. We also report classical signatures of competition, namely, clamping of the second-harmonic power and production of nondegenerate frequencies in the visible. Theory is presented that describes the observations as resulting from competition between various chi((2)) up-conversion and down-conversion processes. We show that competition imposes hitherto unsuspected limits to both power generation and squeezing. The observed signatures are expected to be significant effects in practical systems.
Resumo:
We have designed, built, and tested an early prototype of a novel subxiphoid access system intended to facilitate epicardial electrophysiology, but with possible applications elsewhere in the body. The present version of the system consists of a commercially available insertion needle, a miniature pressure sensor and interconnect tubing, read-out electronics to monitor the pressures measured during the access procedure, and a host computer with user-interface software. The nominal resolution of the system is <0.1 mmHg, and it has deviations from linearity of <1%. During a pilot series of human clinical studies with this system, as well as in an auxiliary study done with an independent method, we observed that the pericardial space contained pressure-frequency components related to both the heart rate and respiratory rate, while the thorax contained components related only to the respiratory rate, a previously unobserved finding that could facilitate access to the pericardial space. We present and discuss the design principles, details of construction, and performance characteristics of this system.
Resumo:
As nuclear magnetic resonance imaging and spectroscopy move inexorably toward higher field-strength magnets in search of improved signal-to-noise ratio, spectral resolution, and spatial resolution, the way in which radiofrequency (RF) probes are designed changes. At higher frequencies, resonant cavities become the favored RF ''coil'' type and may be built using streamline elements to reduce the inductance of the system. In modeling such systems, the quasi-static approach of assuming that current flows evenly in all conductor cross sections and that adjacent conductors do not affect each other becomes less reasonable. The proximity of RF conductors in resonators typically causes RF eddy currents to flow, whereby the current density in each rung is altered by the RF fields generated by nearby conductors. The proper understanding and prediction of how resonators will perform require a model of the current densities flowing in conducting sections, including all RF eddy current effects. Very few models of this type have been presented in the literature. This article presents an overview of one such model and of how it may be applied to a variety of resonators, both shielded and unshielded, circular, and elliptical, in cross section. Results are presented from a shielded head coil operating at 2 tesla. (C) 1997 John Wiley & Sons, Inc.
Resumo:
Background: Tetralogy of Fallot (TOF) is a congenital conotruncal heart defect commonly found in DiGeorge (DGS) and velocardiofacial (VCFS) syndromes. The deletion of chromosome 22q11 has also been demonstrated in sporadic or familial cases of TOF. The aim of the present study was to investigate the frequency of del22q11 in patients with non-syndromic TOF seen at a tertiary Pediatric Cardiology care center. Method: One hundred and twenty three non-syndromic TOF patients were selected and evaluated by history, physical examination and review of medical records. Venous blood was drawn for genomic DNA extraction after informed consent 22q11 microdeletion diagnosis was conducted through a standardized SNP genotyping assay and consecutive homozygosity mapping. Phenotype-genotype correlations regarding cardiac anatomy were conducted. Results: We evaluated 123 non-syndromic TOF patients for a 22q11 deletion. 105 (85.4%) patients presented pulmonary stenosis and 18 (14.6%) had pulmonary atresia. Eight patients (6.5%) were found to have a deletion. Of the deleted patients, three (37.5%) presented pulmonary atresia. We have verified a tendency towards a higher prevalence of pulmonary atresia when comparing TOF patients with and without 22q11 microdeletion. Conclusions: 22q11.2 deletion in non-syndromic TOF patients is present in approximately 6% of patients. We suggest a tendency towards a higher prevalence of pulmonary atresia in non-syndromic TOF patients with 22q11 microdeletion. Molecular genetic screening of non-syndromic TOF patient may be important for the correct care of these patients and a more specific genetic diagnostic and counseling. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Quantum information theory, applied to optical interferometry, yields a 1/n scaling of phase uncertainty Delta phi independent of the applied phase shift phi, where n is the number of photons in the interferometer. This 1/n scaling is achieved provided that the output state is subjected to an optimal phase measurement. We establish this scaling law for both passive (linear) and active (nonlinear) interferometers and identify the coefficient of proportionality. Whereas a highly nonclassical state is required to achieve optimal scaling for passive interferometry, a classical input state yields a 1/n scaling of phase uncertainty for active interferometry.