998 resultados para Optical clearing agents
Resumo:
En se focalisant sur le cas des joueurs de football professionnels et des danseuses de cabaret, cet article met en lumière le rôle joué par différents types d'intermédiaire dans la mise en place, le développement et la gestion de canaux migratoires. Une attention particulière est accordée aux procédures recrutement et à la gestion de la circulation de ces deux catégories de travailleurs.
Resumo:
In this thesis, cleaning of ceramic filter media was studied. Mechanisms of fouling and dissolution of iron compounds, as well as methods for cleaning ceramic membranes fouled by iron deposits were studied in the literature part. Cleaning agents and different methods were closer examined in the experimental part of the thesis. Pyrite is found in the geologic strata. It is oxidized to form ferrous ions Fe(II) and ferric ions Fe(III). Fe(III) is further oxidized in the hydrolysis to form ferric hydroxide. Hematite and goethite, for instance, are naturally occurring iron oxidesand hydroxides. In contact with filter media, they can cause severe fouling, which common cleaning techniques competent enough to remove. Mechanisms for the dissolution of iron oxides include the ligand-promoted pathway and the proton-promoted pathway. The dissolution can also be reductive or non-reductive. The most efficient mechanism is the ligand-promoted reductive mechanism that comprises two stages: the induction period and the autocatalytic dissolution.Reducing agents(such as hydroquinone and hydroxylamine hydrochloride), chelating agents (such as EDTA) and organic acids are used for the removal of iron compounds. Oxalic acid is the most effective known cleaning agent for iron deposits. Since formulations are often more effective than organic acids, reducing agents or chelating agents alone, the citrate¿bicarbonate¿dithionite system among others is well studied in the literature. The cleaning is also enhanced with ultrasound and backpulsing.In the experimental part, oxalic acid and nitric acid were studied alone andin combinations. Also citric acid and ascorbic acid among other chemicals were tested. Soaking experiments, experiments with ultrasound and experiments for alternative methods to apply the cleaning solution on the filter samples were carried out. Permeability and ISO Brightness measurements were performed to examine the influence of the cleaning methods on the samples. Inductively coupled plasma optical emission spectroscopy (ICP-OES) analysis of the solutions was carried out to determine the dissolved metals.
Resumo:
Despite using modern microbiological diagnostic approaches, the aetiological agents of pneumonia remain unidentified in about 50% of cases. Some bacteria that grow poorly or not at all in axenic media used in routine clinical bacteriology laboratory but which can develop inside amoebae may be the agents of these lower respiratory tract infections (RTIs) of unexplained aetiology. Such amoebae-resisting bacteria, which coevolved with amoebae to resist their microbicidal machinery, may have developed virulence traits that help them survive within human macrophages, i.e. the first line of innate immune defence in the lung. We review here the current evidence for the emerging pathogenic role of various amoebae-resisting microorganisms as agents of RTIs in humans. Specifically, we discuss the emerging pathogenic roles of Legionella-like amoebal pathogens, novel Chlamydiae (Parachlamydia acanthamoebae, Simkania negevensis), waterborne mycobacteria and Bradyrhizobiaceae (Bosea and Afipia spp.).
Resumo:
PURPOSE: To investigate choroidal vascular abnormalities in peripheral exudative hemorrhagic chorioretinopathy, using dynamic ultrawide-field fluorescein angiography (FA) and indocyanine green angiography (ICGA).¦DESIGN: Prospective observational case series.¦METHODS: This institutional study comprised a consecutive series of 40 patients (48 eyes) with peripheral exudative hemorrhagic chorioretinopathy. Choroidal vascular abnormalities were assessed with dynamic ultrawide-field (150-degree) FA and ICGA, using the Staurenghi 230 SLO Retina Lens and the Heidelberg scanning laser ophthalmoscope. The main outcome measures were morphologic descriptions of structural vascular abnormalities and choroidal hemodynamics (comparison with 30 normal eyes).¦RESULTS: The peripheral mass lesions were highly exudative and hemorrhagic, and usually associated with a pigment epithelium detachment. FA revealed nonspecific alterations corresponding to the visible fundoscopic changes (window defects, blockage, staining), but no neovascular membrane. However, despite frequent masking, ICGA showed hyperfluorescent polyp-like structures in the choroid of the lesion area in 33 eyes (69%) and an abnormal choroidal vascular network in 24 eyes (50%). The abnormal choroidal vascular network filled in the arterial or early venous phase, while the polyp-like structures filled some seconds later. Optical coherence tomography revealed the typical dome-shaped elevation of the pigment epithelium over the vascular polyps. Peripheral choriocapillaris closure was observed as well as dilated shunting vessels.¦CONCLUSION: Peripheral exudative hemorrhagic chorioretinopathy shares many characteristics (polyp-like choroidal telangiectases, abnormal choroidal vascular networks, exudative and hemorrhagic presentation) with polypoidal choroidal vasculopathy. Clarification of the precise role of these abnormalities requires further studies.
Resumo:
We have synthesized a family of rheinhuprine hybrids to hit several key targets for Alzheimer"s disease. Biological screening performed in vitro and in Escherichia coli cells has shown that these hybrids exhibit potent inhibitory activities against human acetylcholinesterase butyrylcholinesterase, and BACE-1, dual Aβ42 and tau anti-aggregating activity, and brain permeability. Ex vivo studies with the leads (+)- and ()-7e in brain slices of C57bl6 mice have revealed that they efficiently protect against the Aβ-induced synaptic dysfunction , preventing the loss of synaptic proteins and/or have a positive effect on the induction of long term potentiation. In vivo studies in APP-PS1 transgenic mice treated i.p. for 4 weeks with (+)- and ()-7e have shown a central soluble Aβ lowering effect, accompanied by an increase in the levels of mature amyloid precursor protein (APP). Thus, (+)- and ()-7e emerge as very promising disease-modifying anti-Alzheimer drug candidates.
Resumo:
We have synthesized a family of rheinhuprine hybrids to hit several key targets for Alzheimer"s disease. Biological screening performed in vitro and in Escherichia coli cells has shown that these hybrids exhibit potent inhibitory activities against human acetylcholinesterase butyrylcholinesterase, and BACE-1, dual Aβ42 and tau anti-aggregating activity, and brain permeability. Ex vivo studies with the leads (+)- and ()-7e in brain slices of C57bl6 mice have revealed that they efficiently protect against the Aβ-induced synaptic dysfunction , preventing the loss of synaptic proteins and/or have a positive effect on the induction of long term potentiation. In vivo studies in APP-PS1 transgenic mice treated i.p. for 4 weeks with (+)- and ()-7e have shown a central soluble Aβ lowering effect, accompanied by an increase in the levels of mature amyloid precursor protein (APP). Thus, (+)- and ()-7e emerge as very promising disease-modifying anti-Alzheimer drug candidates.
Resumo:
Thanks to the continuous progress made in recent years, medical imaging has become an important tool in the diagnosis of various pathologies. In particular, magnetic resonance imaging (MRI) permits to obtain images with a remarkably high resolution without the use of ionizing radiation and is consequently widely applied for a broad range of conditions in all parts of the body. Contrast agents are used in MRI to improve tissue discrimination. Different categories of contrast agents are clinically available, the most widely used being gadolinium chelates. One can distinguish between extracellular gadolinium chelates such as Gd-DTPA, and hepatobiliary gadolinium chelates such as Gd-BOPTA. The latter are able to enter hepatocytes from where they are partially excreted into the bile to an extent dependent on the contrast agent and animal species. Due to this property, hepatobiliary contrast agents are particularly interesting for the MRI of the liver. Actually, a change in signal intensity can result from a change in transport functions signaling the presence of impaired hepatocytes, e.g. in the case of focal (like cancer) or diffuse (like cirrhosis) liver diseases. Although the excretion mechanism into the bile is well known, the uptake mechanisms of hepatobiliary contrast agents into hepatocytes are still not completely understood and several hypotheses have been proposed. As a good knowledge of these transport mechanisms is required to allow an efficient diagnosis by MRI of the functional state of the liver, more fundamental research is needed and an efficient MRI compatible in vitro model would be an asset. So far, most data concerning these transport mechanisms have been obtained by MRI with in vivo models or by a method of detection other than MRI with cellular or sub-cellular models. Actually, no in vitro model is currently available for the study and quantification of contrast agents by MRI notably because high cellular densities are needed to allow detection, and no metallic devices can be used inside the magnet room, which is incompatible with most tissue or cell cultures that require controlled temperature and oxygenation. The aim of this thesis is thus to develop an MRI compatible in vitro cellular model to study the transport of hepatobiliary contrast agents, in particular Gd-BOPTA, into hepatocytes directly by MRI. A better understanding of this transport and especially of its modification in case of hepatic disorder could permit in a second step to extrapolate this knowledge to humans and to use the kinetics of hepatobiliary contrast agents as a tool for the diagnosis of hepatic diseases.
Resumo:
In this thesis fouling of conventional filter fabrics and membranes was studied. In the beginning of the thesis fouling and how it can be measured and predicted is reviewed. Information on different methods on how fouling canbe decreased or cleaned away is also given. The experimental part is divided into two sections; fabric filtration and membrane filtration. Fouling of the filter fabrics was studied with silica or cupper slurries and fouling of the membranes was studied with pulp and paper mill waters. The fouled filter materials were characterised according to many different methods. The most useful way to observe fouling is to measure the changes in the permeate flux. Fouling can also be seen visually e.g. with scanning electron microscopy. Consequently, also the reason for the fouling in question might be found. Different filtration characteristics affect fouling e.g. as the filtration pressure was increased it did not have much influence on the permeate flux, but the pressure caused the membrane to get fouled faster. Also, an increase of shear rate on the membrane surface decreased fouling. Different pretreatment methods for the effluent were tested in membrane filtration to decrease fouling. The tested methods; biological treatment, ozonation, enzymatic treatment and flocculation, did not have a clear influence on the fouling of the membrane, but e.g. a biological treatment combined with ultrafiltration made the tested groundwood mill circulation water purer than ultrafiltration alone.
Resumo:
This thesis considers nondestructive optical methods for metal surface and subsurface inspection. The main purpose of this thesis was to study some optical methods in order to find out their applicability to industrial measurements. In laboratory testing the simplest light scattering approach, measurement of specular reflectance, was used for surface roughness evaluation. Surface roughness, curvature and finishing process of metal sheets were determined by specular reflectance measurements. Using a fixed angleof incidence, the specular reflectance method might be automated for industrialinspection. For defect detection holographic interferometry and thermography were compared. Using either holographic interferometry or thermography, relativelysmall-size defects in metal plates could be revealed. Holographic techniques have some limitations for industrial measurements. On the contrary, thermography has excellent prospects for on-line inspection, especially with scanning techniques.
Resumo:
In this paper, the sensor of an optical mouse is presented as a counterfeit coin detector applied to the two-Euro case. The detection process is based on the short distance image acquisition capabilities of the optical mouse sensor where partial images of the coin under analysis are compared with some partial reference coin images for matching. Results show that, using only the vision sense, the counterfeit acceptance and rejection rates are very similar to those of a trained user and better than those of an untrained user.
Resumo:
The following paper introduces the work conducted to create a relative virtual mouse based on the interpretation of head movements and face gesture through a low cost camera and the optical flow of the images. This virtual device is designed specifically as an alternative non-contact pointer for people with mobility impairments in the upper extremities and reduced head control. The proposed virtual device was compared with a conventional mouse, a touchpad and a digital joystick. Validation results show performances close to a digital joystick but far away from a conventional mouse.
Resumo:
We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and gradient waveforms such that the field-of-view was realigned to match the subject's head movement. Task-free fMRI experiments on five healthy volunteers followed a 2×2×3 factorial design with the following factors: PMC on or off; 3.0mm or 1.5mm isotropic resolution; and no, slow, or fast head movements. Visual and motor fMRI experiments were additionally performed on one of the volunteers at 1.5mm resolution comparing PMC on vs PMC off for no and slow head movements. Metrics were developed to quantify the amount of motion as it occurred relative to k-space data acquisition. The motion quantification metric collapsed the very rich camera tracking data into one scalar value for each image volume that was strongly predictive of motion-induced artifacts. The PMC system did not introduce extraneous artifacts for the no motion conditions and improved the time series temporal signal-to-noise by 30% to 40% for all combinations of low/high resolution and slow/fast head movement relative to the standard acquisition with no prospective correction. The numbers of activated voxels (p<0.001, uncorrected) in both task-based experiments were comparable for the no motion cases and increased by 78% and 330%, respectively, for PMC on versus PMC off in the slow motion cases. The PMC system is a robust solution to decrease the motion sensitivity of multi-shot 3D EPI sequences and thereby overcome one of the main roadblocks to their widespread use in fMRI studies.
Resumo:
Es descriu la síntesi de nous compostos ciclopal·ladats derivats d'imines i amines primàries, òpticament actius, així com les seves aplicacions per a la determinació de l'excés enantiomèric i per a la resolució de bases de Lewis. També es comenta la síntesi i resolució de noves fosfines P-quirals, així com la seva aplicació a processos de catàlisi asimètrica. A més, es descriu la preparació d'algunes fosfines secundàries quirals i s'estudia la seva estabilitat configuracional.