993 resultados para OPTICAL-DETECTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present results on the use of multilayered a-SiC:H heterostructures as a device for wavelength-division demultiplexing of optical signals. These devices are useful in optical communications applications that use the wavelength division multiplexing technique to encode multiple signals into the same transmission medium. The device is composed of two stacked p-i-n photodiodes, both optimized for the selective collection of photo generated carriers. Band gap engineering was used to adjust the photogeneration and recombination rate profiles of the intrinsic absorber regions of each photodiode to short and long wavelength absorption in the visible spectrum. The photocurrent signal using different input optical channels was analyzed at reverse and forward bias and under steady state illumination. A demux algorithm based on the voltage controlled sensitivity of the device was proposed and tested. An electrical model of the WDM device is presented and supported by the solution of the respective circuit equations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present structural, optical and transport data on GaN samples grown by hybrid, two-step low temperature pulsed laser deposition. The band gap of samples with good crystallinity has been deduced from optical spectra. Large below gap band tails were observed. In samples with the lowest crystalline quality the PL spectra are quite dependent on spot laser incidence. The most intense PL lines can be attributed to excitons bounded to stacking faults. When the crystalline quality of the samples is increased the ubiquitous yellow emission band can be detected following a quenching process described by a similar activation energy to that one found in MOCVD grown samples. The samples with the highest quality present, besides the yellow band, show a large near band edge emission which peaked at 3.47 eV and could be observed up to room temperature. The large width of the NBE is attributed to effect of a wide distribution of band tail states on the excitons. Photoconductivity data supports this interpretation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this review paper different designs based on stacked p-i'-n-p-i-n heterojunctions are presented and compared with the single p-i-n sensing structures. The imagers utilise self-field induced depletion layers for light detection and a modulated laser beam for sequential readout. The effect of the sensing element structure, cell configurations (single or tandem), and light source properties (intensity and wavelength) are correlated with the sensor output characteristics (light-to-dark sensivity, spatial resolution, linearity and S/N ratio). The readout frequency is optimized showing that scans speeds up to 104 lines per second can be achieved without degradation in the resolution. Multilayered p-i'-n-p-i-n heterostructures can also be used as wavelength-division multiplexing /demultiplexing devices in the visible range. Here the sensor element faces the modulated light from different input colour channels, each one with a specific wavelength and bit rate. By reading out the photocurrent at appropriated applied bias, the information is multiplexed or demultiplexed and can be transmitted or recovered again. Electrical models are present to support the sensing methodologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVES: To detect anti-Giardia lamblia serum antibodies in healthy children attending public day care centers and to assess serological tests as tools for estimating the prevalence of G. lamblia in endemic areas. METHODS: Three separate stool specimens and filter paper blood samples were collected from 147 children ranging from 0 to 6 years old. Each stool sample was processed using spontaneous sedimentation and zinc sulfate flotation methods. Blood samples were tested by indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assay (ELISA) for Giardia IgG. RESULTS AND CONCLUSIONS: Of 147 individuals tested, 93 (63.3%) showed Giardia cysts in their feces. Using IIF and ELISA, serum antibodies were detected in 93 (63.3%) and 100 (68%) samples , respectively. Sensitivity of IIF and ELISA was 82% and 72%, respectively. However, ELISA revealed to be less specific (39%) than IIF (70%). IIF also showed a higher concordance with microscopic examination than ELISA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Characteristics of tunable wavelength pi'n/pin filters based on a-SiC:H multilayered stacked cells are studied both experimental and theoretically. Results show that the device combines the demultiplexing operation with the simultaneous photodetection and self amplification of the signal. An algorithm to decode the multiplex signal is established. A capacitive active band-pass filter model is presented and supported by an electrical simulation of the state variable filter circuit. Experimental and simulated results show that the device acts as a state variable filter. It combines the properties of active high-pass and low-pass filter sections into a capacitive active band-pass filter using a changing photo capacitance to control the power delivered to the load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin films of TiO2 were doped with Au by ion implantation and in situ during the deposition. The films were grown by reactive magnetron sputtering and deposited in silicon and glass substrates at a temperature around 150 degrees C. The undoped films were implanted with Au fiuences in the range of 5 x 10(15) Au/cm(2)-1 x 10(17) Au/cm(2) with a energy of 150 keV. At a fluence of 5 x 10(16) Au/cm(2) the formation of Au nanoclusters in the films is observed during the implantation at room temperature. The clustering process starts to occur during the implantation where XRD estimates the presence of 3-5 nm precipitates. After annealing in a reducing atmosphere, the small precipitates coalesce into larger ones following an Ostwald ripening mechanism. In situ XRD studies reveal that Au atoms start to coalesce at 350 degrees C, reaching the precipitates dimensions larger than 40 nm at 600 degrees C. Annealing above 700 degrees C promotes drastic changes in the Au profile of in situ doped films with the formation of two Au rich regions at the interface and surface respectively. The optical properties reveal the presence of a broad band centered at 550 nm related to the plasmon resonance of gold particles visible in AFM maps. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – A diabetes é uma das maiores epidemias do último século. Mais de 250 milhões de pessoas, em todo o mundo, sofrem de diabetes. Das complicações derivadas da diabetes são as principais causas de cegueira, de insuficiência renal e de amputação de membros inferiores, derivando estes, predominantemente, da disfunção vascular. Quando surge perda de pericitos na parede vascular ocorrem uma série de alterações da microcirculação que levam ao aparecimento de microaneurismas e outras alterações vasculares que possibilitam a passagem de componentes sanguíneos para o tecido retiniano adjacente que, em situação de normalidade, não ocorreriam, sendo esta uma das causas do edema macular exsudativo diabético. A perimetria de hiperacuidade preferencial (PHP) é um teste psicofísico que pretende detetar metamorfopsias na Degenerescência Macular ligada à Idade (DMI). Uma vez que o edema macular diabético (EMD) se destaca como uma das principais causas de deficiência visual e baixa visão, pretende-se verificar a eficácia do PHP no estudo do edema macular diabético, respondendo à seguinte questão: “Qual a capacidade do perímetro de hiperacuidade preferencial em detetar metamorfopsias em pacientes com edema macular diabético?“ Metodologia – Estudo quantitativo, do tipo descritivo e correlacional. Selecionou-se uma amostra de 33 pacientes, onde se analisou um total de 60 olhos. Resultados – A sensibilidade do PHP na deteção de metamorfopsias associadas ao EMD na tomografia de coerência ótica (OCT) foi de 70,6%, a especificidade foi de 11,5% e a eficiência global do teste de 45%. Comparando os resultados encontrados no PHP e no OCT, constatou-se a existência de uma correlação inversa fraca (Phi = -0,215). Conclusões – Este novo método de diagnóstico revela-se sensível, contudo pouco específico e eficaz na deteção de metamorfopsias consequentes da existência de EMD. - ABSTRACT - Introduction – Preferential hyperacuity perimeter (PHP) is a new psychophysical test, which principle is based on the detection of metamorphopsia in age-related macular degeneration (AMD). It is intended to verify its effectiveness in the study of diabetic macular edema (DME). When there is loss of pericytes in the vascular wall occur a number of microcirculatory changes that lead to the appearance of microaneurysms and other vascular changes that allow the passage of blood components to the surrounding retinal tissue than in normal situation does not occur, this being one of the causes exudative diabetic macular edema. Methodology – It was performed a quantitative study, using descriptive and correlational analysis. A sample of 33 patients was selected, and 60 eyes were analyzed. Results – The sensitivity of PHP on the detection of metamorphopsia associated to EMD was 70.6%, the specificity was 11.5% and the global efficiency of the test was 45%. It was found a weak negative correlation (Phi= -0.215) between the PHP and optical coherence tomography (OCT). Conclusions – This new method of diagnosis was sensitive, but not very specific and effective on the detection of metamorphopsia, due to the DME.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structures experience various types of loads along their lifetime, which can be either static or dynamic and may be associated to phenomena of corrosion and chemical attack, among others. As a consequence, different types of structural damage can be produced; the deteriorated structure may have its capacity affected, leading to excessive vibration problems or even possible failure. It is very important to develop methods that are able to simultaneously detect the existence of damage and to quantify its extent. In this paper the authors propose a method to detect and quantify structural damage, using response transmissibilities measured along the structure. Some numerical simulations are presented and a comparison is made with results using frequency response functions. Experimental tests are also undertaken to validate the proposed technique. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amorphous Si/SiC photodiodes working as photo-sensing or wavelength sensitive devices have been widely studied. In this paper single and stacked a-SiC:H p-i-n devices, in different geometries and configurations, are reviewed. Several readout techniques, depending on the desired applications (image sensor, color sensor, wavelength division multiplexer/demultiplexer device) are proposed. Physical models are presented and supported by electrical and numerical simulations of the output characteristics of the sensors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present results on the use of a multilayered a-SiC:H heterostructure as a wavelength-division demultiplexing device for the visible light spectrum. The proposed device is composed of two stacked p-i-n photodiodes with intrinsic absorber regions adjusted to short and long wavelength absorption and carrier collection. An optoelectronic characterisation of the device was performed in the visible spectrum. Demonstration of the device functionality for WDM applications was done with three different input channels covering the long, the medium and the short wavelengths in the visible range. The recovery of the input channels is explained using the photocurrent spectral dependence on the applied voltage. An electrical model of the WDM device is proposed and supported by the solution of the respective circuit equations. Short range optical communications constitute the major application field, however other applications are also foreseen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To comparatively detect A. actinomycetemcomitans and F. nucleatum from periodontal and healthy sites. METHODS: Subgingival clinical samples from 50 periodontitis adult patients and 50 healthy subjects were analyzed. Both organisms were isolated using a trypticase soy agar-bacitracin-vancomycin (TSBV) medium and detected by PCR. Conventional biochemical tests were used for bacteria identification. RESULTS: A. actinomycetemcomitans and F. nucleatum were isolated in 18% and 20% of the patients, respectively, and in 2% and 24% of healthy subjects. Among A. actinomycetemcomitans isolates, biotype II was the most prevalent. Primer pair AA was 100% sensitive in the detection of A. actinomycetemcomitans from both subject groups. Primers ASH and FU were also 100% sensitive to detect this organism in healthy subject samples. Primer pair FN5047 was more sensitive to detect F. nucleatum in patients or in healthy samples than primer 5059S. Primers ASH and 5059S were more specific in the detection of A. actinomycetemcomitans and F. nucleatum, respectively, in patients and in healthy subject samples. CONCLUSIONS: PCR is an effective tool for detecting periodontal pathogens in subgingival samples, providing a faster and safer diagnostic tool of periodontal diseases. The method's sensitivity and specificity is conditioned by the choice of the set of primers used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the capacity of laser scanning cytometry (LSC) to detect acid-fast bacilli directly on clinical samples, a comparison between Kinyoun-stained smears analyzed under light microscopy and propidium iodide-auramine-stained smears analyzed by LSC was performed. The results were compared with those for culture on BACTEC MGIT 960. LSC is a new, reliable methodology to detect Mycobacteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presença de sistemas eletrónicos nos veículos automóveis tem vindo a aumentar de forma considerável nos últimos 30 anos, tornando possível o aumento dos padrões de eficiência, segurança e conforto dos mesmos. Os sistemas de acionamento automático dos limpa-para-brisas, baseados em sensores de chuva óticos, têm registado um crescimento quase exponencial nos últimos 10 a 15 anos; no ano 2000, apenas 5 % dos veículos novos produzidos na Europa estavam equipados com este sistema, hoje é um equipamento amplamente difundido na oferta automóvel existente. O presente trabalho consistiu no estudo de uma solução para deteção de chuva em veículos automóveis com a aplicação de um sensor piezoelétrico, tendo em vista a obtenção de uma solução mais versátil e aplicável em vários pontos do veículo. As reduzidas dimensões, a elevada sensibilidade do sensor e a facilidade de aplicação nas superfícies de ensaio foram fatores que motivaram a escolha deste tipo de equipamento como elemento sensorial. As hipóteses definidas para o procedimento laboratorial basearam-se nas conclusões obtidas em estudos anteriormente desenvolvidos no campo dos sensores de chuva para automóveis e nas capacidades dos materiais piezoelétricos para medição de pluviosidade. Os sensores foram instalados sob as superfícies do veículo que apresentavam, simultaneamente, uma maior exposição à pluviosidade, quando este está em movimento, e um menor risco de sofrer danos. Os resultados obtidos permitiram concluir que a utilização deste tipo de sensores permite detetar elevados níveis de pluviosidade e em superfícies com considerável capacidade de deformação elástica. A sua implementação futura em veículos automóveis exige mais algum trabalho de melhoria dos processos de fixação dos sensores e do condicionamento de sinal utilizados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on optical filters based on a-SiC:H tandem pi'n/pin heterostructures. The spectral sensitivity is analyzed. Steady state optical bias with different wavelengths are applied from each front and back sides and the photocurrent is measured. Results show that it is possible to control the sensitivity of the device and to tune a specific wavelength range by combining radiations with complementary light penetration depths. The transfer characteristics effects due to changes in the front and back optical bias wavelength are discussed. Depending on the wavelength of the external background and irradiation side, the device acts either as a short- or a long-pass band filter or as a band-stop filter. The output waveform presents a nonlinear amplitude-dependent response to the wavelengths of the input channels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glucose sensing is an issue with great interest in medical and biological applications. One possible approach to glucose detection takes advantage of measuring changes in fluorescence resonance energy transfer (FRET) between a fluorescent donor and an acceptor within a protein which undergoes glucose-induced changes in conformation. This demands the detection of fluorescent signals in the visible spectrum. In this paper we analyzed the emission spectrum obtained from fluorescent labels attached to a protein which changes its conformation in the presence of glucose using a commercial spectrofluorometer. Different glucose nanosensors were used to measure the output spectra with fluorescent signals located at the cyan and yellow bands of the spectrum. A new device is presented based on multilayered a-SiC:H heterostructures to detect identical transient visible signals. The transducer consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructure optimized for the detection of the fluorescence resonance energy transfer between fluorophores with excitation in the violet (400 nm) and emissions in the cyan (470 nm) and yellow (588 nm) range of the spectrum. Results show that the device photocurrent signal measured under reverse bias and using appropriate steady state optical bias, allows the separate detection of the cyan and yellow fluorescence signals presented.