994 resultados para Number States
Resumo:
The aim of this study was the assessment of exposure to ultrafine in the urban environment of Lisbon, Portugal, due to automobile traffic, and consisted of the determination of deposited alveolar surface area in an avenue leading to the town center during late spring. This study revealed differentiated patterns for weekdays and weekends, which could be related with the fluxes of automobile traffic. During a typical week, ultrafine particles alveolar deposited surface area varied between 35.0 and 89.2 mu m(2)/cm(3), which is comparable with levels reported for other towns such in Germany and the United States. These measurements were also complemented by measuring the electrical mobility diameter (varying from 18.3 to 128.3 nm) and number of particles that showed higher values than those previously reported for Madrid and Brisbane. Also, electron microscopy showed that the collected particles were composed of carbonaceous agglomerates, typical of particles emitted by the exhaustion of diesel vehicles. Implications: The approach of this study considers the measurement of surface deposited alveolar area of particles in the outdoor urban environment of Lisbon, Portugal. This type of measurements has not been done so far. Only particulate matter with aerodynamic diameters <2.5 (PM2.5) and >10 (PM10) mu m have been measured in outdoor environments and the levels found cannot be found responsible for all the observed health effects. Therefore, the exposure to nano- and ultrafine particles has not been assessed systematically, and several authors consider this as a real knowledge gap and claim for data such as these that will allow for deriving better and more comprehensive epidemiologic studies. Nanoparticle surface area monitor (NSAM) equipments are recent ones and their use has been limited to indoor atmospheres. However, as this study shows, NSAM is a very powerful tool for outdoor environments also. As most lung diseases are, in fact, related to deposition of the alveolar region of the lung, the metric used in this study is the ideal one.
Resumo:
A nationwide seroepidemiologic survey of human T. cruzi infection was carried out in Brazil from 1975 to 1980 as a joint programme of the Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) and the Superintendência de Campanhas (SUGAM), Ministry of Health, of Brazil. Due to the marked heterogeneity of urban populations as result of wide migratory movements in the country and since triatomine transmission of the disease occurs mostly in rural areas, the survey was limited to rural populations. The survey was based on a large cluster sampling of complete households, from randomly selected localities comprised of 10 to 500 houses, or up to 200 houses in the Amazon region. Random selection of localities and houses was permitted by a detailed mapping of every locality in the country, as performed and continuously adjusted, by SUCAM. In the selected houses duplicate samples on filter paper were collected from every resistent 1 year or older. Samples were tested in one of 14 laboratories scattered in the country by the indirect anti-IgG immunofluorescence test, with reagents produced and standardized by a central laboratory located at the Instituto de Medicina Tropical de São Paulo. A continuous quality control was performed at this laboratory, which tested duplicates of 10% to 15% of all samples examined by the collaborating laboratories. Data regarding number of sera collected, patients'age, sex, place of residence, place of birth and test result were computerized at the Department of Preventive Medicine, Medical School, University of São Paulo, São Paulo, Brazil. Serologic prevalence indices were estimated for each Municipality and mapped according to States and Territories in Brazil. Since data were already available for the State of São Paulo and the Federal District, these unities were not included in the survey.
Resumo:
Our main objective is to estimate the additional health care costs to the Portuguese National Health Service (NHS) due to domestic violence against women. We collected information through a survey addressed to health care centres’ female users. Both victims and non-victims of violence were inquired. We estimate costs according to five different groups – consultation costs, health care treatment and therapeutic costs, costs of complementary and diagnostic exams, drugs costs and transport costs. The estimations have been split into two perspectives – the NHS perspective (public perspective) and private perspective of inquired women (out of pocket payments). The timeframe of our calculations is one year, referring to all costs generated by domestic violence situations in the last twelve months. Essentially costs were estimated through the product of total number of episodes by the average estimated price per episode. Additionally, for the private costs, we also considered the costs originated by income losses, the opportunity cost of time spent on health care treatments and the work inability caused by sickness. The results suggest that the victims of domestic violence’s additional demand for health care is valued €140 per annum, that is about 22% higher than health care costs of non-victims. These results match those of similar studies for the United States, taking account of per capita differences in health care spending. A large proportion (90%) of the additional costs associated with domestic violence is supported by the NHS, where consultations and drugs are the most important contributors of such costs. Health consequences of domestic violence result from losses in quality of life and worst health status of victims and correspond to additional permanent economic costs of domestic violence episodes.
Resumo:
The aim of this study is to contribute to the assessment of exposure levels of ultrafine particles (UFP) in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung-deposited alveolar surface area (resulting from exposure to UFP) in a major avenue leading to the town centre during late Spring, as well as in indoor buildings facing it. This study revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels could be directly related with the fluxes of automobile traffic. During a typical week, UFP alveolar deposited surface area varied between 35.0 and 89.2 mu m(2)/cm(3), which is comparable with levels reported for other towns such in Germany and United States. The measured values allowed the determination of the number of UFP per cm(3), which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32-63%) outdoor, which is somewhat lower than levels observed in houses in Ontario.
Resumo:
The aim of this study was to contribute to the assessment of exposure levels of ultrafine particles in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung deposited alveolar surface area (resulting from exposure to ultrafine particles) in a major avenue leading to the town center during late spring, as well as in indoor buildings facing it. Data revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels may be directly correlated with fluxes in automobile traffic. During a typical week, amounts of ultrafine particles per alveolar deposited surface area varied between 35 and 89.2 mu m2/cm3, which are comparable with levels reported for other towns in Germany and the United States. The measured values allowed for determination of the number of ultrafine particles per cubic centimeter, which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32 to 63%) outdoors, which is somewhat lower than levels observed in houses in Ontario.
Resumo:
Dissertation presented to obtain the PhD degree in Biochemistry at the Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa
Resumo:
As Leis de Potência, LP, (Power Laws, em inglês), Leis de Pareto ou Leis de Zipf são distribuições estatísticas, com inúmeras aplicações práticas, em sistemas naturais e artificiais. Alguns exemplos são a variação dos rendimentos pessoais ou de empresas, a ocorrência de palavras em textos, as repetições de sons ou conjuntos de sons em composições musicais, o número de vítimas em guerras ou outros cataclismos, a magnitude de tremores de terra, o número de vendas de livros ou CD’s na internet, o número de sítios mais acedidos na Internet, entre muitos outros. Vilfredo Pareto (1897-1906) afirma, no manual de economia política “Cours d’Economie Politique”, que grande parte da economia mundial segue uma determinada distribuição, em que 20% da população reúne 80% da riqueza total do país, estando, assim uma pequena fração da sociedade a controlar a maior fatia do dinheiro. Isto resume o comportamento de uma variável que segue uma distribuição de Pareto (ou Lei de Potência). Neste trabalho pretende-se estudar em pormenor a aplicação das leis de potência a fenómenos da internet, como sendo o número de sítios mais visitados, o número de links existentes em determinado sítio, a distribuição de nós numa rede da internet, o número livros vendidos e as vendas em leilões online. Os resultados obtidos permitem-nos concluir que todos os dados estudados são bem aproximados, numa escala logarítmica, por uma reta com declive negativo, seguindo, assim, uma distribuição de Pareto. O desenvolvimento e crescimento da Web, tem proporcionado um aumento do número dos utilizadores, conteúdos e dos sítios. Grande parte dos exemplos presentes neste trabalho serão alvo de novos estudos e de novas conclusões. O fato da internet ter um papel preponderante nas sociedades modernas, faz com que esteja em constante evolução e cada vez mais seja possível apresentar fenómenos na internet associados Lei de Potência.
Resumo:
This paper deals with a hierarchical structure composed by an event-based supervisor in a higher level and two distinct proportional integral (PI) controllers in a lower level. The controllers are applied to a variable speed wind energy conversion system with doubly-fed induction generator, namely, the fuzzy PI control and the fractional-order PI control. The event-based supervisor analyses the operation state of the wind energy conversion system among four possible operational states: park, start-up, generating or brake and sends the operation state to the controllers in the lower level. In start-up state, the controllers only act on electric torque while pitch angle is equal to zero. In generating state, the controllers must act on the pitch angle of the blades in order to maintain the electric power around the nominal value, thus ensuring that the safety conditions required for integration in the electric grid are met. Comparisons between fuzzy PI and fractional-order PI pitch controllers applied to a wind turbine benchmark model are given and simulation results by Matlab/Simulink are shown. From the results regarding the closed loop point of view, fuzzy PI controller allows a smoother response at the expense of larger number of variations of the pitch angle, implying frequent switches between operational states. On the other hand fractional-order PI controller allows an oscillatory response with less control effort, reducing switches between operational states. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
Most of the cases of abdominal angiostrongyliasis in Brazil were reported from the southern States of São Paulo, Paraná, Santa Catarina and Rio Grande do Sul (RS). A study in 27 cases from RS revealed a distinct local epidemiology. Peasants were usually affected, either adults or children, from the mountainous areas in the north of the Suite. There was a seasonal increase in the number of cases, from late spring to autumn, that does not coincide with the rainy season. Besides the most common clinical features of abdominal pain, fever and cosinophilia in the leucogram, painful relapsing episodes were detected in some patients. The abdominal pain could be either localized or diffuse during the rapid evolution to a surgical abdominal condition, with a letality of 7.4%. The use of a serological test and the greater awareness of physicians working in endemic areas is expected to improve the recognition of uncomplicated and benign courses of the disease. This study confirms the known clinical manifestations of abdominal angiostrongyliasis and demonstrates the diversity of its epidemiology.
Resumo:
FCM: UC Bioquímica I - PhD Thesis
Resumo:
Session 7: Playing with Roles, images and improvising New States of Awareness, 3rd Global Conference, 1st November – 3rd November, 2014, Prague, Czech Republic.
Resumo:
Energy consumption is one of the major issues for modern embedded systems. Early, power saving approaches mainly focused on dynamic power dissipation, while neglecting the static (leakage) energy consumption. However, technology improvements resulted in a case where static power dissipation increasingly dominates. Addressing this issue, hardware vendors have equipped modern processors with several sleep states. We propose a set of leakage-aware energy management approaches that reduce the energy consumption of embedded real-time systems while respecting the real-time constraints. Our algorithms are based on the race-to-halt strategy that tends to run the system at top speed with an aim to create long idle intervals, which are used to deploy a sleep state. The effectiveness of our algorithms is illustrated with an extensive set of simulations that show an improvement of up to 8% reduction in energy consumption over existing work at high utilization. The complexity of our algorithms is smaller when compared to state-of-the-art algorithms. We also eliminate assumptions made in the related work that restrict the practical application of the respective algorithms. Moreover, a novel study about the relation between the use of sleep intervals and the number of pre-emptions is also presented utilizing a large set of simulation results, where our algorithms reduce the experienced number of pre-emptions in all cases. Our results show that sleep states in general can save up to 30% of the overall number of pre-emptions when compared to the sleep-agnostic earliest-deadline-first algorithm.
Resumo:
Mestrado em Engenharia Eletrotécnica e de Computadores - Área de Especialização de Sistemas e Planeamento Industrial
Resumo:
Neisseria meningitidis are gram-negative diplococci responsible for cases of meningococcal disease all over the world. The epidemic potential of N. meningitidis serogroup B and C is clearly a function of their serotype antigens more than of their capsular polysaccharides. Until recently, hiperimmune sera were used to detect typing antigens on the bacteria. The advent of monoclonal antibodies (MAbs) offered the opportunity to eliminate many of the cross-reactions and have improved the accuracy and reproducibility of meningococcal serotyping. We have produced a MAb to the outer membrane protein of the already existent serotype 17 that have been detected by the use of hiperimmune rabbit sera. The prevalence of this serotype epitope is low in the Brazilian strains. By using the MAb 17 we could not decrease the percentage of nontypeable serogroup C strains. However, there were a decreasing in nontypeable strains to 13% into serogroup B strains and to 25% into the other serogroups.
Resumo:
Dissertation presented at Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia in fulfilment of the requirements for the Masters degree in Mathematics and Applications, specialization in Actuarial Sciences, Statistics and Operations Research