891 resultados para Microscópio óptico


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of the stomach of ruminants requires further studies because it is a complex process. Therefore, was analyzed the histology and histomorphometry of reticulum at each gestation period. Samples of Nelore fetuses (Bos taurus indicus) was divided in 5 groups: 1 - fetuses at 9 to 15 weeks (8 to 21cm) of gestation, 2 - fetuses at 16 to 22 weeks (23 to 37cm) 3 - fetuses at 23 to 29 weeks (40 to 58cm), 4 - fetuses at 30 to 36 weeks (61 to 77cm) and 5 - fetuses at 37-43 weeks (79 to 88cm). The histological sections were stained with hematoxylin and eosin and Mallory's trichrome and examined by light microscopy. In group 1, the fetuses with 11 cm, showed mucosal projections that eventually become primary crests, lamina propria and submucosa are fused and external and internal muscular and similar. At 16.5 inches, the primary crests had lamina propria and at 18.5 cm, appeared connections between the ridges. In group 2, at 31 cm started epithelial involvement around the crests. In group 3, the fetuses of 42 cm revealed the first secondary papillae and muscular mucosa in the upper portion of the primary crests. Thereafter, it was increased epithelial due to its positioning around the crests, thickening of the lamina propriasubmucosa, muscular layer, especially the internal muscular and serosa. It was concluded that the most visible changes occur in fetuses belonging to the first 3 groups, measurements for the epithelium, muscle layer and total wall were increasing and the other analyzed layers showed variations during fetal development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of the domestic mammals’ stomach is a complex process, especially in ruminants. The objective of this research was to perform the analysis of structures of this organ during prenatal period. Samples of Nelore fetuses rumen (Bos Taurus indicus) were divided into five groups: 1 - fetuses with 9 to 15 weeks (8 to 21cm) of gestation, 2 - fetuses with 16 to 22 weeks (23 to 37cm), 3 - fetuses at 23 to 29 weeks (40 to 58cm) 4 - fetuses with 30 to 36 weeks (61 to 77cm) and 5 - fetuses with 37 to 43 weeks (79 to 88cm). Sections were stained with Hematoxylin and eosin and Mallory's trichrome and examined at light microscope. In group 1, in fetuses with 11 cm, could be seen all the layers, mucosa with high epithelium and light cells, lamina propria fused with submucosa, the muscular layer was with two thin sublayers similar in thickness and serosa was thin too. With 13.5 cm, was observed the first irregularities in the mucosa with epithelium projections and lamina propria that will lead rumen papillae. With 16.5 cm there was differentiation of the lamina propria to the submucosa. In group 2, in fetuses with 28 cm were observed complete papillae. From this stage, the remaining groups, there was an increase in thickness of the epithelium, lamina propria, submucosal and muscular layer whit the inner sublayer more thicker than the external and serosa. It was concluded that the main variations occur in fetuses of groups 1 and 2, and after this phase, there is increased in thickness of all layers until the end of the pregnancy period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Foi atendido no Hospital Veterinário “Luiz Quintiliano de Oliveira”, o felino Nick, SRD, de quatro meses de idade, pesando 700 gramas, com histórico de trauma por arranhadura em bulbo ocular esquerdo. Ao exame físico específico, evidenciou-se úlcera profunda e prolapso de íris, sendo então indicada a enucleação. Ao exame físico geral, observou-se freqüência cardíaca (FC) de 160 batimentos.min-1, frequência respiratória (f) de 80 movimentos.min-1, tempo de preenchimento capilar menor do que dois segundos, temperatura retal (TR) de 39,2oC e mucosas normocoradas. Como medicação pré-anestésica, empregou-se acepromazina (0,04 mg.kg-1) e metadona (0,3 mg.kg-1), administradas pela via intramuscular. A veia femoral esquerda foi cateterizada com cateter 24G para administração de Ringer com Lactato de sódio (10 mL.kg-1.h- 1 ). A indução foi realizada por máscara facial tendo-se como agente o isofluorano em fluxo diluente de 100 mL.kg-1.min-1 de oxigênio a 100%, seguida de intubação orotraqueal com sonda n o 2,5 sem cuff. Seguiu-se a manutenção anestésica com a mesma mistura da indução, administrada por meio de circuito anestésico sem reinalação de gases, do tipo Baraka, mantendose o paciente sob ventilação assistida. Ato contínuo, realizou-se a técnica anestésica peribulbar de punção única inferior, utilizando-se lidocaína 2% com vasoconstritor (3mg.kg-1) associada a bupivacaína 0,5% sem vasoconstritor (0,8mg.kg-1), perfazendo um volume total de 0,3ml.kg-1 . Uma agulha 13x4,5 foi introduzida em todo o seu comprimento com o bisel voltado para a órbita, no terço lateral do fórnice conjuntival inferior da órbita esquerda, administrando-se a associação dos agentes anestésicos locais, seguida de compressão manual da área para facilitar a difusão dos mesmos. Durante o procedimento anestésico, realizou-se a monitoração da FC, f, pressão arterial sistólica (PAS), TR e saturação periférica da hemoglobina (SpO2). O tempo total de anestesia e cirurgia foi de 30 e 20 minutos, respectivamente, e a SpO2, concentração de isofluorano e TR mantiveram-se em 99±1%, 1,7±0,8% e 37,4±1,5oC, respectivamente. O plano anestésico manteve-se estável, sem a necessidade de resgate analgésico. Não houve a ocorrência de reflexo óculo-cardíaco (ROC) frente à manipulação do nervo óptico, o que pode ser atribuída provavelmente ao bloqueio peribulbar. A anestesia regional é frequentemente empregada para cirurgias oftálmicas em humanos, como a facoemulsificação, sendo que o manejo anestésico pode contribuir para o sucesso do procedimento. Pode-se concluir que, também na espécie felina, o bloqueio peribulbar pode ser uma boa alternativa para a realização de protocolos de anestesia balanceada para procedimentos oftálmicos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Risk of mechanical injuries contraindicate brushing and elect chemical agents as appropriate for daily cleaning of dentures relined with resilient materials. It was evaluated the effect of denture cleansers on the wettability of denture relining material (Dentusoft, Dental Medrano). We used 20 discs of acrylic resin thermoactivated VipiCril ® with 30mm diameter and 4mm thick, covered by 2mm Dentusoft ®. Divided into 4grupos were stored in artificial saliva at 37 +1 º C for 30 days, immersed daily for 15minutes in distilled water (GI), Corega ® Tabs (GII), a solution of sodium bicarbonate (GIII) or solution of sodium hypochlorite (GIV) after which, on the soft liner were poured 2 ml of type IV gypsum (Durone IV, Dentsply). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to analysis, showed non-normal distribution, opting for non-parametric test. Kruskal Wallis test performed at 5% significance, there was statistical difference between the groups with lower average contact angle for GII. It was concluded that the chemical cleaning Corega Tabs ® allowed a better adaptation of relining the gypsum studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dental trade has offered dental impression and dental stone for orthodontic use ensuring accurate models. The compatibility between these materials is defined by the wetting of the model surfaces by the mixture water/stone poured over it and the influenced by the method of disinfection of model and disinfectant solution used. It was evaluated the influence of spray disinfection with sodium hypochlorite 1% on the wettability of two commercial alginate (Jeltrate ® - Dentsply and Orthoprint ® - Zhermack) at two commercial type III gypsum (Rio ® - ME and AOBussoli Orthogesso Orthogesso ®-SA). Twenty models were fabricated for each type of alginate, which were divided into two groups (water and sodium hypochlorite), receiving respectively water and sodium hypochlorite 1% spray. Each group of models was then further divided into two subgroups, and on their surface were poured 2 ml of type III gypsum (Gesso Rio® or Orthogesso®). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to ANOVA and founded statistical significance for solutions used. It was concluded that sodium hypochlorite spray improved wettability of alginates studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cares at the manipulation of the alginate (condensation, disinfection of the impression and the time elapsed until the leak of the plaster) deserve special attention considering the great amount of distortions occurring every time the impression is not fill of plaster in a brief space of time and appropriate storage conditions. Besides its adaptation to the plaster suffers influence of the events happened after the impression is removed of the mouth. The purpose of this research was to evaluate the wetting capacity of three brands of alginate (Jeltrate™,Hydrogum™ e Orthoprint™) by the plaster type III (Rio™) under the influence of disinfection by sodium hypochlorite 1% sprays and the time of storage of 15 minutes,30 minutes, 1 hour, 6, 12 and 24 hours. There were made 60 impressions of each brand of alginate divided in two groups (water and sodium hypochlorite 1%) rearranged after the application of the sodium hypochlorite spray according to the storage time (15 or 30 minutes and 1,6,12, or 24 hours). On the surface of the impressions 2ml of plaster were flowed, proportioned and condensed in agreement with manufacturer‘s instructions. After the final setting expansion the casts were sectioned vertically and medially, regularized at the cut surface (emery paper 400) and setted for reading the contact angle at the microscope Carl Zeiss. The obtained results, submitted to statistical treatment (ANOVA) revealed significant differences when compared the employed solutions (water and sodium hypochlorite 1%) and the time of storage. The sodium hypochlorite 1% exhibited the smallest contact angles and the times of storage of 15 minutes and 6 hours the smallest and larger angles, respectively. It can be concluded that the alginate impressions exhibited larger adaptation to the plaster when disinfected by hypochlorite of sodium 1% and stocked by 15 minutes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nanotubes have been subject of studies with regard to their ability to promote differentiation of several cells lines. Nanotubes have been used to increase the roughness of the implant surfaces and to improve bone tissue integration on dental implant. In this study TiO2 nanotube layer prepared by anodic oxidation was evaluated. Nanotube formation was carried out using Glycerol-H2O DI(50-50 v/v)+NH4F(0,5 a 1,5% and 10-30V) for 1-3 hours at 37ºC. After nanostructure formation the topography of surface was observed using field-emission-scanning-microscope (FE-SEM). Contact angle was evaluated on the anodized and non-anodized surfaces using a water contact angle goniometer in sessile drop mode with 5 μL drops. In the case of nanotube formation and no treatment surface were presented 39,1° and 75,9°, respectively. The contact angle describing the wettability of the surface is enhanced, more hydrophilic, on the nanotube surfaces, which can be advantageous for enhancing protein adsorption and cell adhesion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This in vitro study evaluated the demineralization around restorations class V made on the buccal and lingual surfaces of teeth when using different restorative materials. Thirty extracted teeth were randomly divided into 3 groups (n=10) according to the restorative material: Group I - Fuji II LC (GC America Inc., Alsip, Illinois, USA), Group II - Tetric (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Group III - Chelon Fil (3M/ESPE., Seefeld, Germany). The teeth were submitted to a pH-cycling model associated to a thermocycling model. Sections were made and the specimens were analyzed under a polarized light microscopy as for the presence of demineralization. Measurements were performed and the results were subjected to statistical analysis using Anova and Tukey´s Test (α=0.05). Mean values of demineralization depth (µm) according to each positions showed that the demineralization was significantly reduced when Chelon Fil (Group III) was used for all depths, when compared to fluoridated resin materials. Also, it was verified that non-fluoridated resin material, composite resin Tetric, had the lowest inhibitory effect on the development of demineralization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This confocal microscopy study evaluated the cement/dentin and cement/post interfaces along theroot canalwallswhenfiberglasspostswerebonded to dentin using different types of cements. Material & Methods: Thirty endodontically treated premolars were divided into 3 groups according to the adhesive materials used in the bonding procedure: Prime & Bond 2.1/Self Cure + Enforce, RelyX Unicem and RelyX Luting. Rhodamine B dye was incorporated in the luting materials for the cementation of the fiber glass posts (Exacto, Angelus) to dentin. Three transversal slices (apical, middle and coronal) were examined under confocal laser scanning microscopy. Statistical analysis was performed using the Kappa, Kruskal-Wallis and Dunnet tests, in a significance level of 5%. Results: The Prime & Bond 2.1/Self Cure + Enforce presented a uniform formation of tags in the dentin but gaps in the cement/dentin interface. The RelyX Unicem and RelyX Luting presented an adhesive interface with a fewer amount of gaps, but showed shorter tag formation than the Enforce system. All cements presented the same pattern of bubbles inside the cements. The RelyX Luting presented a greater amount of cracks inside the cement in comparison with the other cements in the coronal third, while no difference was observed between RelyX Unicem and Enforce. The RelyX Luting showed the lowest quantity of cement penetration into the post. Conclusion: In general, the quality of bonding interfaces of fiber posts luted to root canals was affected by both location and type of cement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For this purpose, samples of Nelore fetus abomasum (Bos taurus indicus) were classified into five groups: 1 – fetuses with 9 to 15 weeks (8 to 21 cm) of gestation, 2 – fetuses with 16 to 22 weeks (23 to 37 cm), 3 – fetuses at 23 to 29 weeks (40 to 58 cm) 4 – fetuses with 30 to 36 weeks (61 to 77 cm) and 5 – fetuses with 37 to 43 weeks (79 to 88 cm). Histologic sections were stained with Hematoxylin and eosin, picrosirius and Mallory’s trichrome methods and examined under light microscopy. In fetus with 11 cm of length showed deep mucosa, wide folds and villi lined by single cylindrical epithelium, lamina propria, submucosa, muscular sublayers and serosa. Fetus with 13.5 cm, villi were evident and muscular layer of the mucosa was formed. At 16.5 cm, could be seen an increase in mucosa glands size and number. In fetus of 26 cm, showed gastric mucous glands at great number and ramifications. At 29 cm large folds, were observed. At 37 cm, showed glandular epithelium, muscular layer of the mucosa and muscular layer well development. Fetus with 42 cm, showed deep glands with corresponding mucous cells surrounding by thin lamina propria. It was concluded that the histomorphometric values of muscular layer and total abomasum wall were increased for all groups except for groups 4 and 5 which there was a decline of values, without presenting a significant difference and there was no continuous pattern of growth for other components of abomasum wall.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Histomorphometric data were obtained from cats uterine horns: either nulliparous (n = 6), primiparous (n = 6), multiparous (n = 6) and treated with contraceptive (n = 6). The material was collected after surgery, fixed in paraformaldehyde and embedded in paraplast® resin to be sliced in a microtome. The obtained sections were stained with hematoxylin - eosin and measured under a light microscope: uterine wall total thickness (μm), endometrium total height, endometrial glands diameter and glandular epithelia height, total myometrium, internal and external myometrium and vascular layer thickness. It was concluded that: 1 - contraceptive use and number of pregnancies altered the uterine structure, 2 - one pregnancy does not appear to affect the uterine lining structures as occurs in multiparous cats, 3 – there was no variation on the evaluated structures between nulliparous and primiparous cats except for inner myometrium, 4 - the total myometrium hight and the endometrium hight showed similar variations except for the contraceptive treated cats group, 5 - the outer myometrium showed marked changes in the treated cats, 6 – the less marked morphological variations were for the endometrial glands diameter and glandular epithelium hight, 7 - the presence of dilated endometrial glands was found only in treated cats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)