967 resultados para Measurement range
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2012
Resumo:
Amphisbaena nigricauda Gans, 1966 is a small, poorly known amphisbaenid endemic to the restinga of the states of Espírito Santo and Bahia, Brazil. We analyze 178 specimens collected in Vitória municipality, state of Espírito Santo, Brazil, to investigate whether this species show sexual dimorphism in pre-cloacal pores and in morphological characters. Sex was determined by a ventral incision and direct inspection of gonads. A PCA analysis was performed to generate a general body size measurement. A T test and the non-parametric Mann-Whitney test were used to assess whether this species show sexual dimorphism on five morphometric and five meristic characters, respectively. Sex could not be determined in 36 specimens because they were mutilated in the posterior portion of their bodies. The diagnosis of the species is redefined based on this sample size: the smallest number of body annuli changes from 222 to 192, the number of dorsal and ventral segments in an annulus in the middle of the body changes to 9-11/13-16 (instead of 10/16), and the autotomic tail annulus lies between annulus 7-10 (instead of 6-9). The number of tail annuli remained within the known range of variation of the species (19-24). None of the 80 females analyzed showed pre-cloacal pores, whereas within males 59 out of 62 specimens displayed four and two specimens displayed five pre-cloacal pores. A single male did not possess pre-cloacal pores, but showed irregular scales on its cloacal region. Sex-based difference based on presence or absence of pre-cloacal pores as well as males with wider head was seen in other Neotropical amphisbaenids. However, a pattern of body size differences between males and females has not been identified so far in the few amphisbaenid species studied in this regard. Further studies on this taxonomic group are still needed to elucidate the existence of general patterns of sexual dimorphism and to identify the selective pressures driving these patterns.
Resumo:
This paper develops the link between poverty and inequality by focussing on a class of poverty indices (some of them well-known) which aggregate normative concerns for absolute and relative deprivation. The indices are distinguished by a parameter that captures the ethical sensitivity of poverty measurement to ``exclusion'' or ``relative-deprivation'' aversion. We also show how the indices can be readily used to predict the impact of growth on poverty. An illustration using LIS data finds that he United States show more relative deprivation than Denmark and Belgium whatever the percentiles considered, but that overall deprivation comparisons of the four countries considered will generally necessarily depend on the intensity of the ethical concern for relative deprivation. The impact of growth on poverty is also seen to depend on the presence of and on the attention granted to concerns over relative deprivation. }
Resumo:
In this paper well-known summary inequality indexes are used to explore interregional income inequalities in Europe. In particular, we mainly employ Theilspopulation-weighted index because of its appealing properties. Two decomposition analysis are applied. First, regional inequalities are decomposed by regional subgroups (countries). Second, intertemporal inequality changes are separated into income and population changes. The main results can be summarized as follows. First, data confirm a reduction in crossregional inequality during 1982-97. Second, this reduction is basically due to real convergence among countries. Third, currently the greater part of European interregional disparities is within-country by nature, which introduce an important challenge for the European policy. Fourth, inequality changes are due mainly to income variations, population changes playing a minor role.
Resumo:
PURPOSE: To evaluate a diagnostic strategy for pulmonary embolism that combined clinical assessment, plasma D-dimer measurement, lower limb venous ultrasonography, and helical computed tomography (CT). METHODS: A cohort of 965 consecutive patients presenting to the emergency departments of three general and teaching hospitals with clinically suspected pulmonary embolism underwent sequential noninvasive testing. Clinical probability was assessed by a prediction rule combined with implicit judgment. All patients were followed for 3 months. RESULTS: A normal D-dimer level (<500 microg/L by a rapid enzyme-linked immunosorbent assay) ruled out venous thromboembolism in 280 patients (29%), and finding a deep vein thrombosis by ultrasonography established the diagnosis in 92 patients (9.5%). Helical CT was required in only 593 patients (61%) and showed pulmonary embolism in 124 patients (12.8%). Pulmonary embolism was considered ruled out in the 450 patients (46.6%) with a negative ultrasound and CT scan and a low-to-intermediate clinical probability. The 8 patients with a negative ultrasound and CT scan despite a high clinical probability proceeded to pulmonary angiography (positive: 2; negative: 6). Helical CT was inconclusive in 11 patients (pulmonary embolism: 4; no pulmonary embolism: 7). The overall prevalence of pulmonary embolism was 23%. Patients classified as not having pulmonary embolism were not anticoagulated during follow-up and had a 3-month thromboembolic risk of 1.0% (95% confidence interval: 0.5% to 2.1%). CONCLUSION: A noninvasive diagnostic strategy combining clinical assessment, D-dimer measurement, ultrasonography, and helical CT yielded a diagnosis in 99% of outpatients suspected of pulmonary embolism, and appeared to be safe, provided that CT was combined with ultrasonography to rule out the disease.
Resumo:
OBJECTIVE: Local heating increases skin blood flow SkBF (thermal hyperemia). In a previous study, we reported that a first local thermal stimulus could attenuate the hyperemic response to a second one applied later on the same skin spot, a phenomenon that we termed desensitization. However, other studies found no evidence for desensitization in similar conditions. The aim of the present work was to test whether it was related to differences in instrumentation. METHODS: Twenty-eight healthy young males were studied. Two pairs of heating chambers, one custom-made (our study) and one commercial (other groups), were affixed to forearm skin. SkBF was measured with single-point laser-Doppler flowmetry (LDF) (780nm) in one pair, and laser-Doppler imaging (LDI) (633nm) in the other. A temperature step from 34 to 41°C, was applied for 30minutes and repeated after two hours. RESULTS: During the second thermal challenge, the plateau SkBF was lower than during the first thermal and was observed with each of the four combinations of SkBF measurement techniques and heating equipment (p<0.05 for all conditions, range -9% to -16% of the initial value). CONCLUSION: Desensitization of thermal hyperemia is not specific to peculiar operating conditions.
Resumo:
Polarization indices presented up to now have only focused their attention on the distribution of income/wealth. However, in many circumstances income is not the only relevant dimension that might be the cause of social conflict, so it is very important to have a social polarization index able to cope with alternative dimensions. In this paper we present an axiomatic characterization of one of such indices: it has been obtained as an extension of the (income) polarization measure introduced in Duclos, Esteban and Ray (2004) to a wider domain. It turns out that the axiomatic structure introduced in that paper alone is not appropriate to obtain a fully satisfactory characterization of our measure, so additional axioms are proposed. As a byproduct, we present an alternative axiomatization of the aforementioned income polarization measure.
Resumo:
The traditional basis for assessing the effect of antihypertensive therapy is the blood pressure reading taken by a physician. However, several recent trials have been designed to evaluate the blood pressure lowering effect of various therapeutic agents during the patients' normal daytime activities, using a portable, semi-automatic blood pressure recorder. The results have shown that in a given patient, blood pressure measured at the physician's office often differs greatly from that prevailing during the rest of the day. This is true both in treated and untreated hypertensive patients. The difference between office and ambulatory recorded pressures cannot be predicted from blood pressure levels measured by the physician. Therefore, a prospective study was carried out in patients with diastolic blood pressures that were uncontrolled at the physician's office despite antihypertensive therapy. The purpose was to evaluate the response of recorded ambulatory blood pressure to treatment adjustments aimed at reducing office blood pressure below a pre-set target level. Only patients with high ambulatory blood pressures at the outset appeared to benefit from further changes in therapy. Thus, ambulatory blood pressure monitoring can be used to identify those patients who remain hypertensive only when facing the physician, despite antihypertensive therapy. Ambulatory monitoring could thus help to evaluate the efficacy of antihypertensive therapy and allow individual treatment.
Resumo:
AIMS: Bicuspid aortic valve (BAV) causes complex flow patterns in the ascending aorta (AAo), which may compromise the accuracy of flow measurement by phase-contrast magnetic resonance (PC-MR). Therefore, we aimed to assess and compare the accuracy of forward flow measurement in the AAo, where complex flow is more dominant in BAV patients, with flow quantification in the left ventricular outflow tract (LVOT) and the aortic valve orifice (AV), where complex flow is less important, in BAV patients and controls. METHODS AND RESULTS: Flow was measured by PC-MR in 22 BAV patients and 20 controls at the following positions: (i) LVOT, (ii) AV, and (iii) AAo, and compared with the left ventricular stroke volume (LVSV). The correlation between the LVSV and the forward flow in the LVOT, the AV, and the AAo was good in BAV patients (r = 0.97/0.96/0.93; P < 0.01) and controls (r = 0.96/0.93/0.93; P < 0.01). However, in relation with the LVSV, the forward flow in the AAo was mildly underestimated in controls and much more in BAV patients [median (inter-quartile range): 9% (4%/15%) vs. 22% (8%/30%); P < 0.01]. This was not the case in the LVOT and the AV. The severity of flow underestimation in the AAo was associated with flow eccentricity. CONCLUSION: Flow measurement in the AAo leads to an underestimation of the forward flow in BAV patients. Measurement in the LVOT or the AV, where complex flow is less prominent, is an alternative means for quantifying the systolic forward flow in BAV patients.
Resumo:
Patient adherence to medications has been an issue challenging healthcare professionals for decades. Adherence rates, causes of non-adherence, barriers and enablers to medication taking, interventions to promote adherence, and the impact of non-adherence on health outcomes, have been extensively studied. In light of this, the area of adherence research has progressed conceptually and practically. This special issue contains a range of articles which focus on different aspects of adherence, from standardising terminology and methods of measurement, to non-adherence in a broad range of patient populations, and to interventions to promote adherence.
Resumo:
We propose a new method, based on inertial sensors, to automatically measure at high frequency the durations of the main phases of ski jumping (i.e. take-off release, take-off, and early flight). The kinematics of the ski jumping movement were recorded by four inertial sensors, attached to the thigh and shank of junior athletes, for 40 jumps performed during indoor conditions and 36 jumps in field conditions. An algorithm was designed to detect temporal events from the recorded signals and to estimate the duration of each phase. These durations were evaluated against a reference camera-based motion capture system and by trainers conducting video observations. The precision for the take-off release and take-off durations (indoor < 39 ms, outdoor = 27 ms) can be considered technically valid for performance assessment. The errors for early flight duration (indoor = 22 ms, outdoor = 119 ms) were comparable to the trainers' variability and should be interpreted with caution. No significant changes in the error were noted between indoor and outdoor conditions, and individual jumping technique did not influence the error of take-off release and take-off. Therefore, the proposed system can provide valuable information for performance evaluation of ski jumpers during training sessions.
Resumo:
Therapeutic drug monitoring (TDM) aims to optimize treatments by individualizing dosage regimens based on the measurement of blood concentrations. Dosage individualization to maintain concentrations within a target range requires pharmacokinetic and clinical capabilities. Bayesian calculations currently represent the gold standard TDM approach but require computation assistance. In recent decades computer programs have been developed to assist clinicians in this assignment. The aim of this survey was to assess and compare computer tools designed to support TDM clinical activities. The literature and the Internet were searched to identify software. All programs were tested on personal computers. Each program was scored against a standardized grid covering pharmacokinetic relevance, user friendliness, computing aspects, interfacing and storage. A weighting factor was applied to each criterion of the grid to account for its relative importance. To assess the robustness of the software, six representative clinical vignettes were processed through each of them. Altogether, 12 software tools were identified, tested and ranked, representing a comprehensive review of the available software. Numbers of drugs handled by the software vary widely (from two to 180), and eight programs offer users the possibility of adding new drug models based on population pharmacokinetic analyses. Bayesian computation to predict dosage adaptation from blood concentration (a posteriori adjustment) is performed by ten tools, while nine are also able to propose a priori dosage regimens, based only on individual patient covariates such as age, sex and bodyweight. Among those applying Bayesian calculation, MM-USC*PACK© uses the non-parametric approach. The top two programs emerging from this benchmark were MwPharm© and TCIWorks. Most other programs evaluated had good potential while being less sophisticated or less user friendly. Programs vary in complexity and might not fit all healthcare settings. Each software tool must therefore be regarded with respect to the individual needs of hospitals or clinicians. Programs should be easy and fast for routine activities, including for non-experienced users. Computer-assisted TDM is gaining growing interest and should further improve, especially in terms of information system interfacing, user friendliness, data storage capability and report generation.
Resumo:
BACKGROUND: The Adolescent Drug Abuse Diagnosis (ADAD) and Health of Nation Outcome Scales for Children and Adolescents (HoNOSCA) are both measures of outcome for adolescent mental health services. AIMS: To compare the ADAD with HoNOSCA; to examine their clinical usefulness. METHODS: Comparison of the ADAD and HoNOSCA outcome measures of 20 adolescents attending a psychiatric day care unit. RESULTS: ADAD change was positively correlated with HoNOSCA change. HoNOSCA assesses the clinic's day-care programme more positively than the ADAD. The ADAD detects a group for which the mean score remains unchanged whereas HoNOSCA does not. CONCLUSIONS: A good convergent validity emerges between the two assessment tools. The ADAD allows an evidence-based assessment and generally enables a better subject discrimination than HoNOSCA. HoNOSCA gives a less refined evaluation but is more economic in time and possibly more sensitive to change. Both assessment tools give useful information and enabled the Day-care Unit for Adolescents to rethink the process of care and of outcome, which benefited both the institution and the patients.
Resumo:
The paper employs a rank-dependent formulation of the social welfare function with time-separable utilities to evaluate the economic consequences of income mobility from an ex-ante perspective. The resultant class of measures can be decomposed not only in terms of structural and exchange mobility but also in terms of vertical and horizontal mobility, thereby encompassing two of the main approaches in the literature. We illustrate our measurement framework by comparing mobility in the USA and Germany using data from the Cross-National Equivalent File 1980-2005. We find that the pattern of income mobility in the USA was both less pro-poor and more horizontally inequitable than in Germany, but that the latter did not translate into higher levels of exchange mobility given higher levels of absolute inequality and the vertical stance of the growth process.
Resumo:
The aim of this study was to determine whether breath 13CO2 measurements could be used to assess the compliance to a diet containing carbohydrates naturally enriched in 13C. The study was divided into two periods: Period 1 (baseline of 4 days) with low 13C/12C ratio carbohydrates. Period 2 (5 days) isocaloric diet with a high 13C/12C ratio (corn, cane sugar, pineapple, millet) carbohydrates. Measurements were made of respiratory gas exchange by indirect calorimetry, urinary nitrogen excretion and breath 13CO2 every morning in post-absorptive conditions, both in resting state and during a 45-min low intensity exercise (walking on a treadmill). The subjects were 10 healthy lean women (BMI 20.4 +/- 1.7 kg/m2, % body fat 24.4 +/- 1.3%), the 13C enrichment of oxidized carbohydrate and breath 13CO2 were compared to the enrichment of exogenous dietary carbohydrates. At rest the enrichment of oxidized carbohydrate increased significantly after one day of 13C carbohydrate enriched diet and reached a steady value (103 +/- 16%) similar to the enrichment of exogenous carbohydrates. During exercise, the 13C enrichment of oxidized carbohydrate remained significantly lower (68 +/- 17%) than that of dietary carbohydrates. The compliance to a diet with a high content of carbohydrates naturally enriched in 13C may be assessed from the measurement of breath 13CO2 enrichment combined with respiratory gas exchange in resting, postabsorptive conditions.