894 resultados para Measurement in tank
Resumo:
OBJECT: To determine whether glycine can be measured at 7 T in human brain with (1)H magnetic resonance spectroscopy (MRS). MATERIALS AND METHODS: The glycine singlet is overlapped by the larger signal of myo-inositol. Density matrix simulations were performed to determine the TE at which the myo-inositol signal was reduced the most, following a single spin-echo excitation. (1)H MRS was performed on an actively shielded 7 T scanner, in five healthy volunteers. RESULTS: At the TE of 30 ms, the myo-inositol signal intensity was substantially reduced. Quantification using LCModel yielded a glycine-to-creatine ratio of 0.14 +/- 0.01, with a Cramer-Rao lower bound (CRLB) of 7 +/- 1%. Furthermore, quantification of metabolites other than glycine was possible as well, with a CRLB mostly below 10%. CONCLUSION: It is possible to detect glycine at 7 T in human brain, at the short TE of 30 ms with a single spin-echo excitation scheme.
Resumo:
Mast cells are well known for their role in hypersensitivity reactions. However, there is increasing evidence that they might also participate in both developing and weakening atherosclerotic plaques, potentially causing plaque instability. Some clinical studies have therefore postulated the existence of relationships between blood β-tryptase levels and acute coronary syndromes. In this study, we investigated postmortem serum β-tryptase levels in a series of 90 autopsy cases with various degrees of coronary atherosclerosisthat had undergone medico-legal investigations. β-tryptase concentrations in these cases were compared to levels observed in 6 fatal anaphylaxis cases following contrast material administration. Postmortem serum β-tryptase concentrations in the anaphylactic deaths ranged from 146 to 979 ng/ml. In 9 out of 90 cases of cardiac deaths, β-tryptase levels were higher than clinical reference values of 11.4 ng/ml and ranged from 21 to 65 ng/ml. These results indicate that increased postmortem serum β-tryptase levels can be observed, though not systematically, in cardiac deaths with varying degrees of coronary atherosclerosis disease, thereby suggesting that mast cell activation in this disease cannot be ascertained by postmortem serum β-tryptase measurements.
Resumo:
Purpose: The accurate estimation of total energy expenditure (TEE) is essential to allow the provision of nutritional requirements in patients treated by maintenance hemodialysis (MHD). The measurement of TEE and resting energy expenditure (REE) by direct or indirect calorimetry and doubly labeled water are complicated, timeconsuming and cumbersome in this population. Recently, a new system called SenseWear® armband (SWA) was developed to assess TEE, physical activity and REE. This device works by measurements of body acceleration in two axes, heat production and steps counts. REE measured by indirect calorimetry and SWA are well correlated. The aim of this study was to determine TEE, physical activity and REE on patients on MHD using this new device. Methods and materials: Daily TEE, REE, step count, activity time, intensity of activity and lying time were determined for 7 consecutive days in unselected stable patients on MHD and sex, age and weightmatched healthy controls (HC). Patients with malnutrition, cancer, use of immunosuppressive drugs, hypoalbumemia <35 g/L and those hospitalized in the last 3 months, were excluded. For MHD patients, separate analyses were conducted in dialysis and non-dialysis days. Relevant parameters known to affect REE, such as BMI, albumin, pre-albumin, hemoglobin, Kt/V, CRP, bicarbonate, PTH, TSH, were recorded. Results: Thirty patients on MHD and 30 HC were included. In MHD patients, there were 20 men and 10 women. Age was 60,13 years ± 14.97 (mean ± SD), BMI was 25.77 kg/m² ± 4.73 and body weight was 74.65 kg ± 16.16. There were no significant differences between the two groups. TEE was lower in MHD patients compared to HC (28.79 ± 5.51 SD versus 32.91 ± 5.75 SD kcal/kg/day; p <0.01). Activity time was significantly lower in patients on MHD (101.3 ± 12.6SD versus 50.7 ± 9.4 SD min; p = 0.0021). Energy expenditure during the time of activity was significantly lower in MHD patients. MHD patients walked 4543 ± 643 SD vs 8537 ± 744 SD steps per day (p <0.0001). Age was negatively correlated with TEE (r = -0.70) and intensity of activity (r = -0.61) in HC, but not in patients on MHD. TEE showed no difference between dialysis and non-dialysis days (29.92 ± 2.03 SD versus 28.44 ± 1.90 SD kcal/kg/day; p = NS), reflecting a lack of difference in activity (number of steps, time of physical activity) and REE. This finding was observed in MHD patients both older and younger than 60 years. However, age stratification appeared to have an influence on TEE, regardless of dialysis day, (29.92 ± 2.07 SD kcal/kg/day for <60 years-old versus 27.41 ± 1.04 SD kcal/kg/day for ≥60 years old), although failing to reach statistical significance. Conclusion: Using SWA, we have shown that stable patients on MHD have a lower TEE than matched HC. On average, a TEE of 28.79 kcal/kg/day, partially affected by age, was measured. This finding gives support to the clinical impression that it is difficult and probably unnecessary to provide an energy amount of 30-35 kcal/kg/day, as proposed by international guidelines for this population. In addition, we documented for the first time that MHD patients exert a reduced physical activity as compared to HC. There were surprisingly no differences in TEE, REE and physical activity parameters between dialysis and non-dialysis days. This observation might be due to the fact that patients on MHD produce a physical effort to reach the dialysis centre. Age per se did not influence physical activity in MHD patients, contrary to HC, reflecting the impact of co-morbidities on physical activity in this group of patients.
Resumo:
This study tested for the measurement equivalence of a four-factor measure of career indecision (Career Indecision Profile-65 [CIP-65]) between a U.S. sample and two international samples; one composed of French-speaking young adults from France and Switzerland and the other of Italian ado- lescents. Previous research had supported the four-factor structure of the CIP-65 in both the United States and Iceland but also showed that items on two of the four scales may be interpreted differently by young adults growing up in these two countries. This study extends previous research by testing whether the four CIP-65 factors are measured equivalently in two additional international samples. Results largely supported the configural and metric invariance of the CIP-65 in the United States and international samples, but several scales showed a lack of scalar invariance. Some explanations are offered for these findings along with suggestions for future research and implications for practice.
Resumo:
Winter weather in Iowa is often unpredictable and can have an adverse impact on traffic flow. The Iowa Department of Transportation (Iowa DOT) attempts to lessen the impact of winter weather events on traffic speeds with various proactive maintenance operations. In order to assess the performance of these maintenance operations, it would be beneficial to develop a model for expected speed reduction based on weather variables and normal maintenance schedules. Such a model would allow the Iowa DOT to identify situations in which speed reductions were much greater than or less than would be expected for a given set of storm conditions, and make modifications to improve efficiency and effectiveness. The objective of this work was to predict speed changes relative to baseline speed under normal conditions, based on nominal maintenance schedules and winter weather covariates (snow type, temperature, and wind speed), as measured by roadside weather stations. This allows for an assessment of the impact of winter weather covariates on traffic speed changes, and estimation of the effect of regular maintenance passes. The researchers chose events from Adair County, Iowa and fit a linear model incorporating the covariates mentioned previously. A Bayesian analysis was conducted to estimate the values of the parameters of this model. Specifically, the analysis produces a distribution for the parameter value that represents the impact of maintenance on traffic speeds. The effect of maintenance is not a constant, but rather a value that the researchers have some uncertainty about and this distribution represents what they know about the effects of maintenance. Similarly, examinations of the distributions for the effects of winter weather covariates are possible. Plots of observed and expected traffic speed changes allow a visual assessment of the model fit. Future work involves expanding this model to incorporate many events at multiple locations. This would allow for assessment of the impact of winter weather maintenance across various situations, and eventually identify locations and times in which maintenance could be improved.
Resumo:
The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning.
Resumo:
Mast cells are well known for their role in hypersensitivity reactions. However, there is increasing evidence that they might also participate in both developing and weakening atherosclerotic plaques, potentially causing plaque instability. Some clinical studies have therefore postulated the existence of relationships between blood β-tryptase levels and acute coronary syndromes. In this study, we investigated postmortem serum β-tryptase levels in a series of 90 autopsy cases with various degrees of coronary atherosclerosis that had undergone medico-legal investigations. β-tryptase concentrations in these cases were compared to levels observed in 6 fatal anaphylaxis cases following contrast material administration. Postmortem serum β-tryptase concentrations in the anaphylactic deaths ranged from 146 to 979 ng/ml. In 9 out of 90 cases of cardiac deaths, β-tryptase levels were higher than clinical reference values of 11.4 ng/ml and ranged from 21 to 65 ng/ml. These results indicate that increased postmortem serum β-tryptase levels can be observed, though not systematically, in cardiac deaths with varying degrees of coronary atherosclerosis disease, thereby suggesting that mast cell activation in this disease cannot be ascertained by postmortem serum β-tryptase measurements.
The Europeanisation of the measurement of diversity in education: a soft instrument of public policy
Resumo:
Faced with an increasing number of data and rankings, the author questions the roles of the different groups of actors who were originally involved in questioning the use of statistical indicators as a means of addressing issues of access to higher education. The comparison and nature of these international (UNESCO, OECD, EUROSTAT) and national (Germany, England, France, Switzerland) indicators in matters of inequalities of access to higher education question the tension between the discourses and the indicators they generate, and their recording at the national level. Who says what and with what consequences? What range of actors are involved in this process? What kind of power relations forms them? The author discusses how the issue of inequalities of access to higher education got on to the agendas of European organisations, identifies the policies that were defined, and sets them against an array of indicators, showing the discrepancy between the discourses and what the indicators reveal, the gap between the recommendations and the available tools. Why is there such a contrast? What are the mechanisms at work? Is it a technical or a political problem? What does this discrepancy reveal as far as national specificities within the construction of social inequalities are concerned?
Resumo:
In the realm of forensic pathology, β-tryptase measurement for diagnostic purposes is performed in postmortem serum obtained from femoral blood. This may be partially or completely unavailable in some specific cases, such as infant autopsies and severely damaged bodies. The aim of this study was to investigate the usefulness of determining β-tryptase levels for diagnostic purposes in alternative biological samples. Urine, vitreous humor and pericardial fluid were selected and measured in 94 subjects including: fatal anaphylaxis following contrast material administration (6 cases), hypothermia (10 cases), diabetic ketoacidosis (10 cases), gunshot suicide (10 cases), heroin injection-related deaths (18 cases), trauma (10 cases), sudden death with minimal coronary atherosclerosis (10 cases), severe coronary atherosclerosis without myocardial infarction (10 cases) and severe coronary atherosclerosis with myocardial infarction (10 cases). Postmortem serum and pericardial fluid β-tryptase levels higher than the clinical reference value (11.4ng/ml) were systematically identified in fatal anaphylaxis following contrast material administration and 6 cases unrelated to anaphylaxis. β-tryptase concentrations in urine and vitreous humor were lower than the clinical reference value in all cases included in this study. Determination of β-tryptase in pericardial fluid appears to be a possible alternative to postmortem serum in the early postmortem period when femoral blood cannot be collected during autopsy and biochemical investigations are required to objectify increased β-tryptase levels.
Resumo:
The aim of this work is to study the influence of several analytical parameters on the variability of Raman spectra of paint samples. In the present study, microtome thin section and direct (no preparation) analysis are considered as sample preparation. In order to evaluate their influence on the measures, an experimental design such as 'fractional full factorial' with seven factors (including the sampling process) is applied, for a total of 32 experiments representing 160 measures. Once the influence of sample preparation highlighted, a depth profile of a paint sample is carried out by changing the focusing plane in order to measure the colored layer under a clearcoat. This is undertaken in order to avoid sample preparation such a microtome sectioning. Finally, chemometric treatments such as principal component analysis are applied to the resulting spectra. The findings of this study indicate the importance of sample preparation, or more specifically, the surface roughness, on the variability of the measurements on a same sample. Moreover, the depth profile experiment highlights the influence of the refractive index of the upper layer (clearcoat) when measuring through a transparent layer.
Resumo:
The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT.
Resumo:
BACKGROUND: Endothelin-1 is an endothelium-derived potent vasoconstrictor peptide of 21 amino acids. To establish reference values in different models of hypertension and in human subjects an assay for plasma immunoreactive endothelin-1 (ET-1) was optimized. METHODS: ET-1 is extracted by acetone from 1 mL of plasma and subjected to a sensitive enzyme-linked immunosorbent assay. RESULTS: The detection limit for plasma ET-1 is 0.05 fmol/mL. Mean recoveries of the 1, 2, 5, and 10 fmol of ET-1 added to 1 mL of plasma were 66%, 75%, 85%, and 92%, respectively. Within- and between-assay coefficients of variation were < or =12% and < or =10%, respectively. Assay accuracy was demonstrated by consistent recoveries of added ET-1 over the entire physiologic range of plasma concentrations and by the linearity of ET-1 concentrations measured in serially diluted plasma extracts (r = 0.99). No ET-1 was detected when albumin buffer was extracted instead of plasma. Using this method, we found increased ET-1 levels in plasma of three experimental rat models of hypertension: stroke prone spontaneously hypertensive rats (SP-SHR), deoxycorticosterone acetate-salt hypertensive rats, and one kidney-one clip hypertensive rats. In contrast, plasma ET-1 levels of SHR were half those of normotensive Wistar rats. In two kidney-one clip hypertensive rats, plasma ET-1 concentrations were not different from those found in sham-operated control rats. Plasma ET-1 concentrations of 37 healthy men were 0.85 +/- 0.26 fmol/ml (mean +/- SD). CONCLUSIONS: The present assay reliably measures ET-1 levels in rat and human plasma. It allows to discriminate between different forms of hypertension with high or low circulating levels of ET-1.
Resumo:
Velocity-density tests conducted in the laboratory involved small 4-inch diameter by 4.58-inch-long compacted soil cylinders made up of 3 differing soil types and for varying degrees of density and moisture content, the latter being varied well beyond optimum moisture values. Seventeen specimens were tested, 9 with velocity determinations made along two elements of the cylinder, 180 degrees apart, and 8 along three elements, 120 degrees apart. Seismic energy was developed by blows of a small tack hammer on a 5/8-inch diameter steel ball placed at the center of the top of the cylinder, with the detector placed successively at four points spaced 1/2-inch apart on the side of the specimen involving wave travel paths varying from 3.36 inches to 4.66 inches in length. Time intervals were measured using a model 217 micro-seismic timer in both laboratory and field measurements. Forty blows of the hammer were required for each velocity determination, which amounted to 80 blows on 9 laboratory specimens and 120 blows on the remaining 8 cylinders. Thirty-five field tests were made over the three selected soil types, all fine-grained, using a 2-foot seismic line with hammer-impact points at 6-inch intervals. The small tack hammer and 5/8-inch steel ball was, again, used to develop seismic wave energy. Generally, the densities obtained from the velocity measurements were lower than those measured in the conventional field testing. Conclusions were reached that: (1) the method does not appear to be usable for measurement of density of essentially fine-grained soils when the moisture content greatly exceeds the optimum for compaction, and (2) due to a gradual reduction in velocity upon aging, apparently because of gradual absorption of pore water into the expandable interlayer region of the clay, the seismic test should be conducted immediately after soil compaction to obtain a meaningful velocity value.
Resumo:
Ambulatory blood pressure monitoring (ABPM) has become indispensable for the diagnosis and control of hypertension. However, no consensus exists on how daytime and nighttime periods should be defined. OBJECTIVE: To compare daytime and nighttime blood pressure (BP) defined by an actigraph and by body position with BP resulting from arbitrary daytime and nighttime periods. PATIENTS AND METHOD: ABPM, sleeping periods and body position were recorded simultaneously using an actigraph (SenseWear Armband(®)) in patients referred for ABPM. BP results obtained with the actigraph (sleep and position) were compared to the results obtained with fixed daytime (7a.m.-10p.m.) and nighttime (10p.m.-7a.m.) periods. RESULTS: Data from 103 participants were available. More than half of them were taking antihypertensive drugs. Nocturnal BP was lower (systolic BP: 2.08±4.50mmHg; diastolic BP: 1.84±2.99mmHg, P<0.05) and dipping was more marked (systolic BP: 1.54±3.76%; diastolic BP: 2.27±3.48%, P<0.05) when nighttime was defined with the actigraph. Standing BP was higher (systolic BP 1.07±2.81mmHg; diastolic BP: 1.34±2.50mmHg) than daytime BP defined by a fixed period. CONCLUSION: Diurnal BP, nocturnal BP and dipping are influenced by the definition of daytime and nighttime periods. Studies evaluating the prognostic value of each method are needed to clarify which definition should be used.
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.