1000 resultados para Magnetic-mip
Resumo:
AbstractObjective:To define the distal femur rotation pattern in a Brazilian population, correlating such pattern with the one suggested by the arthroplasty instruments, and analyzing the variability of each anatomic parameter.Materials and Methods:A series of 101 magnetic resonance imaging studies were evaluated in the period between April and June 2012. The epidemiological data collection was performed with the aid of the institution's computed imaging system, and the sample included 52 male and 49 female patients. The measurements were made in the axial plane, with subsequent correlation and triangulation with the other plans. The posterior condylar line was used as a reference for angle measurements. Subsequently, the anatomical and surgical transepicondylar axes and the anteroposterior trochlear line were specified. The angles between the reference line and the studied lines were calculated with the aid of the institution's software.Results:The mean angle between the anatomical transepicondylar axis and the posterior condylar line was found to be 6.89°, ranging from 0.25° to 12°. For the surgical transepicondylar axis, the mean value was 2.89°, ranging from –2.23° (internal rotation) to 7.86°, and for the axis perpendicular to the anteroposterior trochlear line, the mean value was 4.77°, ranging from –2.09° to 12.2°.Conclusion:The anatomical transepicondylar angle showed mean values corresponding to the measurement observed in the Caucasian population. The utilized instruments are appropriate, but no anatomical parameter proved to be steady enough to be used in isolation.
Resumo:
Abstract Objective: To assess the prevalence of isolated findings of abnormalities leading to entrapment of the lateral plantar nerve and respective branches in patients complaining of chronic heel pain, whose magnetic resonance imaging exams have showed complete selective fatty atrophy of the abductor digiti quinti muscle. Materials and Methods: Retrospective, analytical, and cross-sectional study. The authors selected magnetic resonance imaging of hindfoot of 90 patients with grade IV abductor digiti quinti muscle atrophy according to Goutallier and Bernageau classification. Patients presenting with minor degrees of fatty muscle degeneration (below grade IV) and those who had been operated on for nerve decompression were excluded. Results: A female prevalence (78.8%) was observed, and a strong correlation was found between fatty muscle atrophy and plantar fasciitis in 21.2%, and ankle varices, in 16.8% of the patients. Conclusion: Fatty atrophy of the abductor digiti quinti muscle is strongly associated with neuropathic alterations of the first branch of the lateral plantar nerve. The present study showed a significant association between plantar fasciitis and ankle varices with grade IV atrophy of the abductor digiti quinti muscle.
Resumo:
Abstract In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI) has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation.
Resumo:
Abstract Ischemic cardiomyopathy is one of the major health problems worldwide, representing a significant part of mortality in the general population nowadays. Cardiac magnetic resonance imaging (CMRI) and cardiac computed tomography (CCT) are noninvasive imaging methods that serve as useful tools in the diagnosis of coronary artery disease and may also help in screening individuals with risk factors for developing this illness. Technological developments of CMRI and CCT have contributed to the rise of several clinical indications of these imaging methods complementarily to other investigation methods, particularly in cases where they are inconclusive. In terms of accuracy, CMRI and CCT are similar to the other imaging methods, with few absolute contraindications and minimal risks of adverse side-effects. This fact strengthens these methods as powerful and safe tools in the management of patients. The present study is aimed at describing the role played by CMRI and CCT in the diagnosis of ischemic cardiomyopathies.
Resumo:
Background and Question Paired-pulse TMS (Transcranial Magnetic Stimulation) paradigms allow explore motor cortex physiology. The Triple Stimulation Technique (TST) improves conventional TMS in quantifying cortico-spinal conduction. The objective of our study was to compare both methods in paired-pulse paradigms of inhibition and of facilitation. Method We investigated paired pulse paradigms of 2 ms (short intra-cortical inhibition) and of 10 ms intervals (intra cortical facilitation) in a randomized order in 22 healthy subjects applying conventional TMS and the TST protocol. Results Paired-pulse paradigms by both TMS and the TST yielded comparable results of short intra- cortical inhibition and intra cortical facilitation. However, the coefficient of variation was significantly smaller for SICI paradigm using TST. Conclusion These results suggest no greater sensitivity of the TST for quantifying inhibition and facilitation. The utility of TST to better quantify the individual amount of inhibition in SICI paradigms and its clinical utility need further studies.
Resumo:
PURPOSE: Orbital tumor recurrence is a rare but serious complication in children with retinoblastoma, leading to a high risk of metastasis and death. Therefore, we assume that these recurrences have to be detected and treated as early as possible. Preliminary studies used magnetic resonance imaging (MRI) to evaluate postsurgical findings in the orbit. In this study, we assessed the diagnostic accuracy of high-resolution MRI to detect orbital tumor recurrence in children with retinoblastoma in a large study cohort. DESIGN: Consecutive retrospective study (2007-2013) assessing MRI findings after enucleation. PARTICIPANTS: A total of 103 MRI examinations of 55 orbits (50 children, 27 male/23 female, mean age 16.3±12.4 months) with a median time of 8 months (range, 0-93) after enucleation for retinoblastoma. METHODS: High-resolution MRI using orbital surface coils was performed on 1.5 Tesla MRI systems to assess abnormal orbital findings. MAIN OUTCOME MEASURES: Five European experts in retinoblastoma imaging evaluated the MRI examinations regarding the presence of abnormal orbital gadolinium enhancement and judged them as "definitive tumor," "suspicious of tumor," "postsurgical condition/scar formation," or "without pathologic findings." The findings were correlated to histopathology (if available), MRI, and clinical follow-up. RESULTS: Abnormal orbital enhancement was a common finding after enucleation (100% in the first 3 months after enucleation, 64.3% >3 years after enucleation). All histopathologically confirmed tumor recurrences (3 of 55 orbits, 5.5%) were correctly judged as "definitive tumor" in MRI. Two orbits from 2 children rated as "suspicious of tumor" received intravenous chemotherapy without histopathologic confirmation; further follow-up (67 and 47 months) revealed no sign of tumor recurrence. In 90.2%, no tumor was suspected on MRI, which was clinically confirmed during follow-up (median follow-up after enucleation, 45 months; range, 8-126). CONCLUSIONS: High-resolution MRI with orbital surface coils may reliably distinguish between common postsurgical contrast enhancement and orbital tumor recurrence, and therefore may be a useful tool to evaluate orbital tumor recurrence after enucleation in children with retinoblastoma. We recommend high-resolution MRI as a potential screening tool for the orbit in children with retinoblastoma to exclude tumor recurrence, especially in high-risk patients within the critical first 2 years after enucleation.
Resumo:
Peer-reviewed
Resumo:
In this paper we present a multi-stage classifier for magnetic resonance spectra of human brain tumours which is being developed as part of a decision support system for radiologists. The basic idea is to decompose a complex classification scheme into a sequence of classifiers, each specialising in different classes of tumours and trying to reproducepart of the WHO classification hierarchy. Each stage uses a particular set of classification features, which are selected using a combination of classical statistical analysis, splitting performance and previous knowledge.Classifiers with different behaviour are combined using a simple voting scheme in order to extract different error patterns: LDA, decision trees and the k-NN classifier. A special label named "unknown¿ is used when the outcomes of the different classifiers disagree. Cascading is alsoused to incorporate class distances computed using LDA into decision trees. Both cascading and voting are effective tools to improve classification accuracy. Experiments also show that it is possible to extract useful information from the classification process itself in order to helpusers (clinicians and radiologists) to make more accurate predictions and reduce the number of possible classification mistakes.
Resumo:
Electrolyte solutions are of importance in a wide range of scientific contexts and as such have attracted considerable theoretical and experimental effort over many years. Nuclear Magnetic resonance provides a precise and versatile tool for investigation of electrolyte solutions, both in water and in organic solvents. Many structural and dynamic properties can be obtained through NMR experiments. The solution of aluminum chloride in water was studied. Different concentrations were taken for investigation. Independence of maximum line shift from concentration and acidity was shown. Six-coordinated structure of solvation shell was confirmed by experiments on 'H and 27A1 nuclei. Diffusion coefficients were studied. The solution of nickel chloride in methanol was studied. Lines, corresponding to coordinated and bulk methanol were found. Four-, five- and six-coordinated structures were found in different temperatures. The line for coordinated -OD group of deuterated methanol was observed on 2H spectrum for the first time. Partial deuteration of CH3 group was detected. Inability to observe coordinated -OH group was explained.
Resumo:
In this work AC magnetometer was developed and primary test measurements were performed for temperature range from 77 K up to 350 K in frequency range from 1 kHz up to 20 kHz. In the course of the present work dependencies of magnetization on temperature for Lao7Sr03Mni _yFeyO3 with y = 0.15, 0.20, 0.25 were obtained in DC magnetic field using SQUID magnetometer and in AC magnetic field using the developed AC magnetometer. Lai.XSrXMnO3 (LSMO) compounds belong to the class of Mn perovskites, which demonstrate very high degree of spin polarization. These materials are of great importance for nowadays applications in spintronics, where spin polarized electron transport is used. Spin glass like behavior was found as a characteristic feature of these solid solutions with the freezing temperature in the range 65 — 210 K.
Resumo:
Based on experimental observations of modulated magnetic patterns in a Co0.5Ni0.205Ga0.295 alloy, we propose a model to describe a (purely) magnetic tweed and a magnetoelastic tweed. The former arises above the Curie (or Nel) temperature due to magnetic disorder. The latter results from compositional fluctuations coupling to strain and then to magnetism through the magnetoelastic interaction above the structural transition temperature. We discuss the origin of purely magnetic and magnetoelastic precursor modulations and their experimental thermodynamic signatures.
Resumo:
In this work magnetic properties of ZnGeP2:Mn were investigated in DC magnetic field with SQUID magnetometer in the temperature range from 3 K up to 400 K and in AC magnetic field with AC magnetometer in the temperature range from 77 K up to 350 K in frequency range from 500 Hz up to 18 KHz. Three ZnGeP2:Mn samples were studied with Mn concentration c = 1.5 % mass, 3 % mass and 3.5 % mass.
Resumo:
In the present work structural, magnetic and transport properties of InGaAs quantum wells (QW) prepared by MBE with an remote Mn layer are investigated. By means of high-resolution X-ray diffractometry the structure of the samples is analyzed. It is shown that Mn ions penetrate into the QW. Influence of the thickness of GaAs spacer and annealing at 286 ºС on the properties of the system is shown. It is shown that annealing of the samples led to Mn activation and narrowing of the Mn layer. Substantial role of 2D holes in ferromagnetic ordering in Mn layer is shown. Evidence for that is observation of maximum at 25 – 55 K on the resistivity temperature dependence. Position of maximum, which is used for quantitative assessment of the Curie temperature, correlates with calculations of the Curie temperature for structures with indirect interaction via 2D holes’ channel. Dependence of the Curie temperature on the spacer thickness shows, that creation of applicable spintronic devices needs high-precision equipment to manufacture extra fine structures. The magnetotransport measurements show that charge carrier mobility is very low. This leads to deficiency of the anomalous Hall effect. At the same time, magnetic field dependences of the magnetization at different temperatures demonstrate that systems are ferromagnetically ordered. These facts, most probably, give evidence of presence of the ferromagnetic MnAs clusters.