835 resultados para Indirect costs
Resumo:
Density Functional Theory (DFT) has been used with an empirically-derived correction for the wavenumbers of vibrational band positions to predict the infrared spectra of several fluorinated esters (FESs). Radiative efficiencies (REs) were then determined using the method of Pinnock et al. and these were used with atmospheric lifetimes from the literature to determine the direct global warming potentials of FESs. FESs, in particular fluoroalkylacetates, alkylfluoroacetates and fluoroalkylformates, are potential greenhouse gases and their likely long atmospheric lifetimes and relatively large REs, compared to their parent HFEs, make them active contributors to global warming. Here, we use the concept of indirect global warming potential (indirect GWP) to assess the contribution to the warming of several commonly used HFEs emitted from the Earth's surface, explicitly taking into account that these HFEs will be converted into the corresponding FESs in the troposphere. The indirect GWP can be calculated using the radiative efficiencies and lifetimes of the HFE and its degradation FES products. We found that the GWPs of those studied HFEs which have the smallest direct GWP can be increased by 100-1600% when taking account of the cumulative effect due to the secondary FESs formed during HFE atmospheric oxidation. This effect may be particularly important for non-segregated HFEs and some segregated HFEs, which may contribute significantly more to global warming than can be concluded from examination of their direct GWPs.
Resumo:
The European Commission’s Biocidal Products Directive (Council Directive 98/8 EC), known as the BPD, is the largest regulatory exercise ever to affect the urban pest control industry. Although focussed in the European Union its impact is global because any company selling pest control products in the EU must follow its principles. All active substances, belonging to 23 different biocidal product types, come within the Directive’s scope of regulatory control. This will eventually involve re-registration of all existing products, as well as affecting any new product that comes to the market. Some active substances, such as the rodenticides and insecticides, are already highly regulated in Europe but others, such as embalming fluids, masonry preservatives, disinfectants and repellents/attractants will come under intensive regulatory scrutiny for the first time. One of the purposes of the Directive is to offer enhanced protection for human health and the environment. The potential benefit for suppliers of pest control products is mutual recognition of regulatory product dossiers across 25 Member States of the European Union. This process, requiring harmonisation of all regulatory decision-making processes, should reduce duplicated effort and, potentially, allow manufacturers speedier access to European markets. However, the cost to industry is enormous, both in terms of the regulatory resources required to assemble BPD dossiers and the development budgets required to conduct studies to meet its new standards. The cost to regulatory authorities is also tremendous, in terms of the need to upgrade staff capabilities to meet new challenges and the volume of the work expected by the Commission when they are appointed the Rapporteur Member State (RMS) for an active substance. Users of pest control products will pay a price too. The increased regulatory costs of maintaining products in the European market are likely to be passed on, at least in part, to users. Furthermore, where the costs of meeting new regulatory requirements cannot be recouped from product sales, many well-known products may leave the market. For example, it seems that in future few rodenticides that are not anticoagulants will be available within the EU. An understanding of the BPD is essential to those who intend to place urban pest control products on the European market and may be useful to those considering the harmonisation of regulatory processes elsewhere. This paper reviews the operation of the first stages of the BPD for rodenticides, examines the potential benefits and costs of the legislation to the urban pest control industry and looks forward to the next stages of implementation involving all insecticides used in urban pest management.
Resumo:
This study investigated whether children’s fears could be un-learned using Rachman’s indirect pathways for learning fear. We hypothesised that positive information and modelling a non-anxious response are effective methods of un-learning fears acquired through verbal information. One hundred and seven children aged 6–8 years received negative information about one animal and no information about another. Fear beliefs and behavioural avoidance were measured. Children were randomised to receive positive verbal information, modelling, or a control task. Fear beliefs and behavioural avoidance were measured again. Positive information and modelling led to lower fear beliefs and behavioural avoidance than the control condition. Positive information was more effective than modelling in reducing fear beliefs and both methods significantly reduced behavioural avoidance. The results support Rachman’s indirect pathways as viable fear un-learning pathways and supports associative learning theories.
Resumo:
In this paper, numerical analyses of the thermal performance of an indirect evaporative air cooler incorporating a M-cycle cross-flow heat exchanger has been carried out. The numerical model was established from solving the coupled governing equations for heat and mass transfer between the product and working air, using the finite-element method. The model was developed using the EES (Engineering Equation Solver) environment and validated by published experimental data. Correlation between the cooling (wet-bulb) effectiveness, system COP and a number of air flow/exchanger parameters was developed. It is found that lower channel air velocity, lower inlet air relative humidity, and higher working-to-product air ratio yielded higher cooling effectiveness. The recommended average air velocities in dry and wet channels should not be greater than 1.77 m/s and 0.7 m/s, respectively. The optimum flow ratio of working-to-product air for this cooler is 50%. The channel geometric sizes, i.e. channel length and height, also impose significant impact to system performance. Longer channel length and smaller channel height contribute to increase of the system cooling effectiveness but lead to reduced system COP. The recommend channel height is 4 mm and the dimensionless channel length, i.e., ratio of the channel length to height, should be in the range 100 to 300. Numerical study results indicated that this new type of M-cycle heat and mass exchanger can achieve 16.7% higher cooling effectiveness compared with the conventional cross-flow heat and mass exchanger for the indirect evaporative cooler. The model of this kind is new and not yet reported in literatures. The results of the study help with design and performance analyses of such a new type of indirect evaporative air cooler, and in further, help increasing market rating of the technology within building air conditioning sector, which is currently dominated by the conventional compression refrigeration technology.
Resumo:
This paper provides a comparative study of the performance of cross-flow and counter-flow M-cycle heat exchangers for dew point cooling. It is recognised that evaporative cooling systems offer a low energy alternative to conventional air conditioning units. Recently emerged dew point cooling, as the renovated evaporative cooling configuration, is claimed to have much higher cooling output over the conventional evaporative modes owing to use of the M-cycle heat exchangers. Cross-flow and counter-flow heat exchangers, as the available structures for M-cycle dew point cooling processing, were theoretically and experimentally investigated to identify the difference in cooling effectiveness of both under the parallel structural/operational conditions, optimise the geometrical sizes of the exchangers and suggest their favourite operational conditions. Through development of a dedicated computer model and case-by-case experimental testing and validation, a parametric study of the cooling performance of the counter-flow and cross-flow heat exchangers was carried out. The results showed the counter-flow exchanger offered greater (around 20% higher) cooling capacity, as well as greater (15%–23% higher) dew-point and wet-bulb effectiveness when equal in physical size and under the same operating conditions. The cross-flow system, however, had a greater (10% higher) Energy Efficiency (COP). As the increased cooling effectiveness will lead to reduced air volume flow rate, smaller system size and lower cost, whilst the size and cost are the inherent barriers for use of dew point cooling as the alternation of the conventional cooling systems, the counter-flow system is considered to offer practical advantages over the cross-flow system that would aid the uptake of this low energy cooling alternative. In line with increased global demand for energy in cooling of building, largely by economic booming of emerging developing nations and recognised global warming, the research results will be of significant importance in terms of promoting deployment of the low energy dew point cooling system, helping reduction of energy use in cooling of buildings and cut of the associated carbon emission.