927 resultados para HARMONIC IMPEDANCE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this paper is to show a methodology to estimate the longitudinal parameters of transmission lines. The method is based on the modal analysis theory and developed from the currents and voltages measured at the sending and receiving ends of the line. Another proposal is to estimate the line impedance in function of the real-time load apparent power and power factor. The procedure is applied for a non-transposed 440 kV three-phase line. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The intent of this paper is to present contributions focused on the analysis and development of harmonic attenuator devices. Among these, highlights here the so-called electromagnetic zero-sequence suppressor. This arrangement consists of a filter and a blocker, both electromagnetic, whose combined operation provides paths for low and high impedance, respectively, which can be conveniently adjusted to the desired performance. In this context, here are present results related to experimental studies that show the behavior of the equipment in front of different operating conditions. The tests were performed on a low-power prototype (1kVA/220V) and the analysis results show the main motivator aspects for the use of these devices. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrochemical impedance spectroscopy measurements using two carbon steel electrodes in soybean biodiesel medium, produced by methylic route, were performed in an electrochemical cell that allows positioning the two electrodes face-to-face. To retain the biodiesel between the electrodes and prevent its leakage a porous membrane soaked in biodiesel was used. The amplitude of the AC potential and the area of the electrodes were varied. The linearity between disturbance and response signals was observed for tests when the amplitude of the AC potential was lower than 1500 mV (rms). The electrical resistance of biodiesel dominates the global response and carbon steel presents low corrosion, which is observed only at low frequency, and was confirmed by chemical tests performed in the membrane. In conclusion the electrical resistance of biodiesel can be estimated using electrochemical impedance spectroscopy with two electrodes set up. ©The Electrochemical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Malnutrition and fluid overload contribute to the poor cardiovascular prognosis of dialysis patients. Since bioelectrical impedance analysis is an option for the evaluation of body composition and for the monitoring of hydration state, it may assist in the identification of subjects at high cardiovascular risk. The objective of this study was to evaluate the association between bioelectrical impedance parameters and cardiovascular events. Methods: The association between bioelectrical impedance parameters and fatal and non-fatal cardiovascular outcome was evaluated in 145 dialysis patients. Results: The mean age of the population studied was 54.9 ± 15.4 years, 49.7 % were males, and 35.9 % had diabetes. Forty (27.6 %) patients developed cardiovascular events during the 16 months (8; 32) of follow-up. Comparison of patients with and without cardiovascular events revealed higher extracellular mass/body cell mass (ECM/BCM) and extracellular water/total body water ratios and higher C-reactive protein levels in the former. Survival analysis showed that an ECM/BCM ratio >1.2 and a phase angle <6° were associated with poor cardiovascular prognosis. Among nondiabetic patients, these parameters and capacitance were independently associated with cardiovascular events, suggesting that poor nutritional status and fluid overload are associated with the occurrence of these events. Conclusions: Phase angle, capacitance and ECM/BCM ratio are valuable parameters for the evaluation of cardiovascular prognosis, supporting the use of bioelectrical impedance for the clinical assessment of dialysis patients. © 2012 Springer Science+Business Media Dordrecht.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eigenstates of a particle in a localized and unconfined harmonic potential well are investigated. Effects due to the variation of the potential parameters as well as certain results from asymptotic expansions are discussed. © 2012 Springer Science+Business Media, LLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents a new method to detect damage in structures based on the electromechanical impedance principle. The system follows the variations in the output voltage of piezoelectric transducers and does not compute the impedance itself. The proposed system is portable, autonomous, versatile, and could efficiently replace commercial instruments in different structural health monitoring applications. The identification of damage is performed by simply comparing the variations of root mean square voltage from response signals of piezoelectric transducers, such as lead zirconate titanate patches bonded to the structure, obtained for different frequencies of the excitation signal. The proposed system is not limited by the sampling rate of analog-to-digital converters, dispenses Fourier transform algorithms, and does not require a computer for processing, operating autonomously. A low-cost prototype based on microcontroller and digital synthesizer was built, and experiments were carried out on an aluminum structure and excellent results have been obtained. © The Author(s) 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On-shell supergravity vertex operators in an AdS 5 × S 5 background are described in the pure spinor formalism by the zero mode cohomology of a BRST operator. After expanding the pure spinor BRST operator in terms of the AdS 5 radius variable, this cohomology is computed using $ \mathcal{N}=4 $ harmonic superspace variables and explicit super-field expressions are obtained for the behavior of supergravity vertex operators near the boundary of AdS 5. © 2013 SISSA, Trieste, Italy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The aim of this study was to compare the rates of local postoperative complications among women undergoing modified radical mastectomy with an electric scalpel (ES) or a harmonic scalpel (HS). It is thought that HS use has less postoperative complications, mainly seroma formation. Methods: This study was a prospective non-randomised clinical trial (NCT01391988) among consecutive patients, performed in parallel. Patients underwent modified radical mastectomy using an HS or ES. We analysed the following operative variables: time, blood loss and seroma volume drainage. Postoperative complications, including seroma, flap necrosis, haematoma and infection were evaluated on the 7th and 14th days. Results: Forty-six patients underwent a MRM with ES and 49 with HS; no differences were observed between the groups. The rate of local complications was 29% in the HS group and 52% in the ES group (p=0.024). The rates of seroma (16.3% versus 28.3%; p=0.161), necrosis (4.1% vs. 21.7%; p=0.013; OR=0.15), haematoma (2.0% vs. 8.7%; p=0.195) and infection (2.0% vs. 6.5%; p=0.351) were lower in the HS group. Adding the findings of all comparative studies using HSs in MRM to the seroma rates in the current study, the seroma rate, expressed as a categorical variable, did not decrease with HS. Seroma was present in 60/219 cases using an HS and in 69/239 cases utilising an ES (p=0.72). Based on a multivariate analysis, HS decreased the risk of skin necrosis (p=0.015). Conclusions: HSs do not decrease the seroma rate. However, this method may be useful in skin sparing mastectomy because it decreases skin flap necrosis. © 2013 Surgical Associates Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the current article, we studied the effect of yttrium [Y3+] ions' substitution on the structure and electric behavior of barium zirconate titanate (BZT) ceramics with a general formula [Ba1-x Y 2x/3](Zr0.25Ti0.75)O3 (BYZT) with [x = 0, 0.025, 0.05] which were prepared by the solid-state reaction method. X-ray diffraction patterns indicate that these ceramics have a single phase with a perovskite-type cubic structure. Rietveld refinement data confirmed [BaO 12], [ZrO6], [TiO6], [YO6] clusters in the cubic lattice. The Y3+ ions' effects on the electric conductivity behavior of BZT ceramics as a function of temperature and frequency are described, which are based on impedance spectroscopy analyses. The complex impedance plots display a double semicircle which highlights the influences of grain and grain boundary on the ceramics. Impedance analyses showed that the resistance decreased with the increasing temperature and resulted in a negative temperature coefficient of the resistance property in all compositions. Modulus plots represent a non-Debye-type dielectric relaxation which is related to the grain and grain boundary as well as temperature-dependent electric relaxation phenomenon and an enhancement in the mobility barrier by Y3+ ions. Moreover, the electric conductivity increases with the replacement of Ba 2+ by Y3+ ions may be due to the rise in oxygen vacancies. © 2013 The Minerals, Metals & Materials Society and ASM International.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel time domain approach for Structural Health Monitoring (SHM) systems based on Electromechanical Impedance (EMI) principle and Principal Component Coefficients (PCC), also known as loadings. Differently of typical applications of EMI applied to SHM, which are based on computing the Frequency Response Function (FRF), in this work the procedure is based on the EMI principle but all analysis is conducted directly in time-domain. For this, the PCC are computed from the time response of PZT (Lead Zirconate Titanate) transducers bonded to the monitored structure, which act as actuator and sensor at the same time. The procedure is carried out exciting the PZT transducers using a wide band chirp signal and getting their time responses. The PCC are obtained in both healthy and damaged conditions and used to compute statistics indexes. Tests were carried out on an aircraft aluminum plate and the results have demonstrated the effectiveness of the proposed method making it an excellent approach for SHM applications. Finally, the results using EMI signals in both frequency and time responses are obtained and compared. © The Society for Experimental Mechanics 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta tese enfoca o estudo de métodos para compensação de harmônicos em sistemas de energia elétrica e aborda diversos aspectos relacionados à presença de harmônicos nos mesmos, como a apresentação de conceitos e definições em sistemas não-senoidais e estratégias de compensação de potência. Enfatiza-se neste estudo, exemplificado por meio de medições e simulações realizadas, a influência da forma de onda de alimentação sobre cargas não-lineares; a interação harmônica entre a tensão de suprimento e a corrente das cargas, devido à impedância série do sistema; e a influência mútua entre cargas não-lineares em paralelo, como possível forma de atenuação de harmônicos. Para simular e predizer o impacto causado por cargas não-lineares em um sistema, assim como a implementação de ações para mitigar esses impactos, visando à melhoria da qualidade da energia, é necessário o conhecimento das respostas das mesmas. Como produto do presente trabalho, destacam-se as técnicas desenvolvidas para a modelagem de cargas nãolineares sob diferentes condições de alimentação, em especial o uso de técnicas de inteligência computacional, como o sistema neuro-fuzzy e as redes neurais artificiais; assim como o emprego da série de Volterra para predição do comportamento das cargas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)