919 resultados para Gradient terms


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship between Islamic Law and other legal systems (basically western type domestic legal orders and international law) is often thought of in terms of compatibility or incompatibility. Concerning certain subject matters of choice, the compatibility of Islamic (legal) principles with the values embedded in legal systems that are regarded as characteristic of the Modern Age is tested by sets of questions: is democracy possible in Islam? Does Islam recognize human rights and are those rights equivalent to a more universal conception? Does Islam recognize or condone more extreme acts of violence and does it justify violence differently? Etc. Such questions and many more presuppose the existence of an ensemble of rules or principles which, as any other set of rules and principles, purport to regulate social behavior. This ensemble is generically referred to as Islamic Law. However, one set of questions is usually left unanswered: is Islamic Law a legal system? If it is a legal system, what are its specific characteristics? How does it work? Where does it apply? It is this paper`s argument that the relationship between Islamic Law and domestic and international law can only be understood if looked upon as a relationship between distinct legal systems or legal orders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A evidência empírica aponta que Termos de Troca é uma variável relevante tanto para dinâmica macroeconômica como para o risco de default em países emergentes. No entanto, a literatura de dívida soberana baseada nos trabalhos de Eaton e Gerzovitz (1981) e Arellano (2008) ainda não explorou de forma adequada as conecções entre a dinâmica de termos de troca e incentivos ao default. Nós contribuímos nessa área, introduzindo volatilidade de Termos de Troca no modelo proposto por Mendoza e Yue (2012), no qual as decisões de dívida soberana são vinculadas à um modelo de equilíbrio geral para a economia doméstica. Nós encontramos que uma economia exposta à volatilidade dos termos de troca consegue produzir uma variabilidade do consumo que supera significativamente a variabilidade do produto, característica que constitui um fato estilizado chave de business cycles de países emergentes. Nossos exercícios também mostram que decisões de default são geradas por mudanças bruscas nos termos de troca, mas não necessariamente estão vinculados à estados ruins da economia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ultra-fast and improved analytical methodology based on microextraction by packed sorbent (MEPS) combined with ultra-performance LC (UPLC) was developed and validated for determination of (E)-resveratrol in wines. Important factors affecting the performance of MEPS such as the type of sorbent material (C2, C8, C18, SIL, and M1), number of extraction cycles, and sample volume were studied. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (50–250mL) in one extraction cycle (extract–discard) and in a short time period (about 3 min for the entire sample preparation step). (E)-Resveratrol was eluted by 1 250mL of the mixture containing 95% methanol and 5% water, and the separation was carried out on a highstrength silica HSS T3 analytical column (100 mm 2.1 mm, 1.8mm particle size) using a binary mobile phase composed of aqueous 0.1% formic acid (eluent A) and methanol (eluent B) in the gradient elution mode (10 min of total analysis). The method was fully validated in terms of linearity, detection (LOD) and quantification (LOQ) limits, extraction yield, accuracy, and inter/intra-day precision, using a Madeira wine sample (ET) spiked with (E)-resveratrol at concentration levels ranging from 5 to 60mg/mL. Validation experiments revealed very good recovery rate of 9575.8% RSD, good linearity with r2 values 40.999 within the established concentration range, excellent repeatability (0.52%), and reproducibility (1.67%) values (expressed as RSD), thus demonstrating the robustness and accuracy of the MEPSC8/UPLC-photodiode array (PDA) method. The LOD of the method was 0.21mg/mL, whereas the LOQ was 0.68mg/mL. The validated methodology was applied to 30 commercial wines (24 red wines and six white wines) from different grape varieties, vintages, and regions. On the basis of the analytical validation, the MEPSC8/UPLC-PDA methodology shows to be an improved, sensitive, and ultra-fast approach for determination of (E)-resveratrol in wines with high resolving power within 6 min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel analytical approach, based on a miniaturized extraction technique, the microextraction by packed sorbent (MEPS), followed by ultrahigh pressure liquid chromatography (UHPLC) separation combined with a photodiode array (PDA) detection, has been developed and validated for the quantitative determination of sixteen biologically active phenolic constituents of wine. In addition to performing routine experiments to establish the validity of the assay to internationally accepted criteria (linearity, sensitivity, selectivity, precision, accuracy), experiments are included to assess the effect of the important experimental parameters on the MEPS performance such as the type of sorbent material (C2, C8, C18, SIL, and M1), number of extraction cycles (extract-discard), elution volume, sample volume, and ethanol content, were studied. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (250 μL) in five extraction cycle and in a short time period (about 5 min for the entire sample preparation step). The wine bioactive phenolics were eluted by 250 μL of the mixture containing 95% methanol and 5% water, and the separation was carried out on a HSS T3 analytical column (100 mm × 2.1 mm, 1.8 μm particle size) using a binary mobile phase composed of aqueous 0.1% formic acid (eluent A) and methanol (eluent B) in the gradient elution mode (10 min of total analysis). The method gave satisfactory results in terms of linearity with r2-values > 0.9986 within the established concentration range. The LOD varied from 85 ng mL−1 (ferulic acid) to 0.32 μg mL−1 ((+)-catechin), whereas the LOQ values from 0.028 μg mL−1 (ferulic acid) to 1.08 μg mL−1 ((+)-catechin). Typical recoveries ranged between 81.1 and 99.6% for red wines and between 77.1 and 99.3% for white wines, with relative standard deviations (RSD) no larger than 10%. The extraction yields of the MEPSC8/UHPLC–PDA methodology were found between 78.1 (syringic acid) and 99.6% (o-coumaric acid) for red wines and between 76.2 and 99.1% for white wines. The inter-day precision, expressed as the relative standard deviation (RSD%), varied between 0.2% (p-coumaric and o-coumaric acids) and 7.5% (gentisic acid) while the intra-day precision between 0.2% (o-coumaric and cinnamic acids) and 4.7% (gallic acid and (−)-epicatechin). On the basis of analytical validation, it is shown that the MEPSC8/UHPLC–PDA methodology proves to be an improved, reliable, and ultra-fast approach for wine bioactive phenolics analysis, because of its capability for determining simultaneously in a single chromatographic run several bioactive metabolites with high sensitivity, selectivity and resolving power within only 10 min. Preliminary studies have been carried out on 34 real whole wine samples, in order to assess the performance of the described procedure. The new approach offers decreased sample preparation and analysis time, and moreover is cheaper, more environmentally friendly and easier to perform as compared to traditional methodologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A large number of evidences correlate elevated levels of homocysteine (Hcys) with a higher cardiovascular diseases (CVDs) risk, especially, atherosclerosis. Similarly, abnormal low levels of the vitamins B6, B9 and B12 are associated to an instability in the methionine cycle with an over production of Hcys. Thus, biomedical sciences are looking forward for a cheaper, faster, precise and accurate analytical methodology to quantify these compounds in a suitable format for the clinical environment. Therefore the objective of this study was the development of a simple, inexpensive and appropriate methodology to use at the clinical level. To achieve this goal, a procedure integrating a digitally controlled (eVol®) microextraction by packed sorbent (MEPS) and an ultra performance liquid chromatography (UPLC) coupled to a photodiode array detector (PDA) was developed to identify and quantify Hcys vitamins B6, B9 and B12. Although different conditions were assayed, we were not able to combine Hcys with the vitamins in the same analytical procedure, and so we proceeded to the optimization of two methods differing only in the composition of the gradient of the mobile phase and the injected volume. It was found that MEPS did not bring any benefit to the quantification of the Hcys in the plasma. Therefore, we developed and validate an alternative method that uses the direct injection of treated plasma (reduced and precipitated). This same method was evaluated in terms of selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect and precision (intra-and inter-day) and applied to the determination of Hcys in a group composed by patients presenting augmented CVD risk. Good results in terms of selectivity and linearity (R2> 0.9968) were obtained, being the values of LOD and LOQ 0.007 and 0.21 mol / L, respectively. The intra-day precision (1.23-3.32%), inter-day precision (5.43-6.99%) and the recovery rate (82.5 to 93.1%) of this method were satisfactory. The matrix effect (>120%) was, however, higher than we were waiting for. Using this methodology it was possible to determine the amount of Hcys in real plasma samples from individuals presenting augmented CVD risk. Regarding the methodology developed for vitamins, despite the optimization of the extraction technique and the chromatographic conditions, it was found that the levels usually present in plasma are far below the sensitivity we obtained. Therefore, further optimizations of the methodology developed are needed. As conclusion, part of the objectives of this study was achieved with the development of a quick, simple and cheaper method for the quantification of Hcys.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As florestas secundárias e plantações de espécies exóticas estão se expandindo nas paisagens tropicais. No entanto, nossa compreensão sobre o valor destas florestas para a conservação da biodiversidade de invertebrados ainda é incipiente. Neste trabalho, usamos a fauna de formigas de serapilheira para avaliar a diversidade desses insetos entre três florestas de Eucalyptus, sendo uma comercial (quatro anos de idade) e duas abandonadas em diferentes idades de regeneração (16 e 31 anos) e uma área de Mata Atlântica secundária. A riqueza total foi mais alta na floresta secundária e nos plantios de Eucalyptus abandonados há mais tempo. A densidade de espécies na floresta secundária foi significativamente maior quando comparado as plantações de Eucalyptus, mas não difere entre eucaliptais; análise de ordenação revelou diferenças na composição de espécies entre as plantações de Eucalyptus com subbosque ausente e com subbosque desenvolvido ou em desenvolvimento. Ainda, foi constatada uma sobreposição acentuada entre amostras de serapilheira das florestas de eucaliptos abandonadas há mais tempo e a floresta secundária. em geral, plantações de eucalipto foram caracterizadas pela presença de espécies generalistas e de ampla distribuição. Nossos resultados indicam que embora o subbosque de plantações de eucaliptos com maior idade de regeneração suporte um conjunto relativamente alto de espécies generalistas de formigas, é improvável que eucaliptais conservem a maioria das espécies de florestas primárias, especialmente predadores especializados, Dacetini e espécies nômades.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar a influência do diluidor do sêmen no desenvolvimento in vitro de ovócitos bovinos após a maturação e fecundação in vitro. Ejaculado de um reprodutor foi fracionado e submetido a três diluidores: Lactose/gema de ovo (LG), Citrato/gema de ovo (CG) e Tris/gema de ovo (TG). Amostras deste material foram envasadas, congeladas e estocadas em N² e, posteriormente, descongeladas; a fração móvel foi separada por gradiente descontínuo de Percoll. A concentração espermática foi ajustada para 10 x 10(6)/mL e a capacitação espermática, induzida com 10 µg/mL de heparina. Após 24 horas de cultura para maturação in vitro, os ovócitos, aspirados de folículos ovarianos, foram inseminados com sêmen diluído em meio TALP e, após 48 horas de cultura, os zigotos foram transferidos para gotas de meio TCM 199, com 5% de soro fetal bovino, 5% de soro de vaca em estro e suspensão de células epiteliais do oviduto bovino, cobertas com óleo de silicone, e mantidos em cultura por nove dias. Todas as culturas foram realizadas a 38,5ºC em atmosfera com 5% de CO2. Os dados foram analisados pelo teste do qui-quadrado e houve diferença com relação à taxa de clivagem (TC), sendo as médias de 66,0; 69,3; e 54,4% para LG, CG e TG, respectivamente. Não houve diferença entre tratamentos com relação às taxas de mórulas/blastocistos ou de eclosão. O diluidor do sêmen não teve efeito sobre o desenvolvimento in vitro de embriões bovinos, embora a TC tenha sido afetada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to assess the morphometry and chromatin integrity of bovine sperm head after a three layers discontinuous Percoll (TM) density gradient centrifugation. Frozen semen doses were obtained from six bulls of different breeds, including three taurine and three Zebu animals. Three ejaculates per bull were evaluated. The semen doses were thawed and two smears were made from each sample before (control) and after the Percoll (TM) centrifugation (Percoll (TM) group). The smears were stained with toluidine blue and grayscale digital images were captured and processed in Scilab environment software. It was observed that chromatin heterogeneity was reduced (P<0.05) and chromatin decondensation was increased (P<0.05) after the Percollm treatment utilized. In addition, it was observed that sperm head length was higher (P<0.05) and the side symmetry was lower (P<0.05) in centrifuged sperm cells. When analyzed separately by subspecies, it was observed that the decrease (P<0.05) in chromatin heterogeneity and the increase (P<0.05) in chromatin decondensation occurred in Zebu sperm heads. In addition, the length and the width:length ratio of sperm heads was affected by Percoll (TM) centrifugation in Zebu semen. In conclusion, the three layers discontinuous Percoll (TM) centrifugation increased the chromatin decondensation and the morphometric alterations of frozen-thawed bovine semen. However, the real implication of these findings in fertility rates of centrifuged sperm must be investigated. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the quality of bovine frozen-thawed sperm cells after Percoll gradient centrifugation. Frozen semen doses were obtained from six bulls of different breeds, including three taurine and three Zebu animals. Four ejaculates per bull were evaluated before and after discontinuous Percoll gradient centrifugation. Sperm motility was assessed by computer-assisted semen analysis and the integrity of the plasma and acrosomal membranes, as well as mitochondrial function, were evaluated using a combination of fluorescent probes propidium iodide, fluorescein isothiocyanate-conjugated Pisum sativum agglutinin and 5,5',6,6'-tetrachloro-1,1',3,3'-tetraethylbenzimidazolcarbocyanine iodide. The procedure of Percoll gradient centrifugation increased the percentage of total and progressive sperm motility, beat frequency, rectilinear motility, linearity and rapidly moving cells. In addition, the percentage of cells with intact plasma membrane and mitochondrial membrane potential was increased in post-centrifugation samples. However, the percentage of sperm cells with intact acrosomal membrane was markedly reduced. The method used selected the motile cells with intact plasma membrane and higher mitochondrial functionality in frozen-thawed bull semen, but processing, centrifugation and/or the Percoll medium caused damage to the acrosomal membrane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to characterize acrosomal ultrastructure following discontinuous Percoll gradient centrifugation of cryopreserved bovine sperm. Semen was collected from six bulls of different breeds and three ejaculates per bull were evaluated. Frozen semen samples were thawed and the acrosomal region of sperm cells was evaluated by transmission electron microscopy (TEM) before (n = 18) and after (n = 18) Percoll centrifugation. The evaluation of 20 sperm heads from each of the 36 samples analyzed ensured that a large number of cells were investigated. The data were subjected to analysis of variance at a level of significance of 5%. Percoll centrifugation reduced the percentage of sperm exhibiting normal acrosomes (from 61.77 to 30.24%), reduced the percentage of sperm presenting atypical acrosome reactions (from 28.38 to 4.84%) and increased the percentage of sperm exhibiting damage in the acrosome (from 6.14 to 64.26%). The percentage of sperm with typical acrosome reactions was not significantly different before (3.70%) and after (0.67%) centrifugation. TEM distinguished four different types of acrosomal status and enabled ultrastructural characterization of acrosomal injuries. The percentage of sperm exhibiting normal acrosomes decreased and damage in the acrosome was the most frequent acrosomal injury with the Percoll gradient centrifugation protocol utilized.