983 resultados para Gibbs stability test
Resumo:
In occupational accidents involving health professionals handling potentially contaminated material, the decision to start or to continue prophylactic medication against infection by Human Immunodeficiency Virus (HIV) has been based on the ELISA test applied to a blood sample from the source patient. In order to rationalize the prophylactic use of antiretroviral agents, a rapid serologic diagnostic test of HIV infection was tested by the enzymatic immunoabsorption method (SUDS HIV 1+2, MUREX®) and compared to conventional ELISA (Abbott HIV-1/ HIV-2 3rd Generation plus EIA®). A total of 592 cases of occupational accidents were recorded at the University Hospital of Ribeirão Preto from July 1998 to April 1999. Of these, 109 were simultaneously evaluated by the rapid test and by ELISA HIV. The rapid test was positive in three cases and was confirmed by ELISA and in one the result was inconclusive and later found to be negative by ELISA. In the 106 accidents in which the rapid test was negative no prophylactic medication was instituted, with an estimated reduction in costs of US$ 2,889.35. In addition to this advantage, the good correlation of the rapid test with ELISA, the shorter duration of stress and the absence of exposure of the health worker to the adverse effects of antiretroviral agents suggest the adoption of this test in Programs of Attention to Accidents with Potentially Contaminated Material.
Resumo:
RESUMO: Introdução/Objectivo: A influência dos factores psicossociais, e nomeadamente da catastrofização da dor, na percepção da intensidade da dor e na incapacidade funcional, auto-reportada por indivíduos com dor crónica cervical (DCC), tem sido alvo de estudo em vários países, evidenciando o constructo multidimensional da DCC. Neste sentido, esta investigação pretende estudar se a catastrofização da dor, é uma variável preditiva relativamente à percepção da intensidade da dor, e à incapacidade funcional. Secundariamente procurou-se averiguar se as relações encontradas se mantêm estáveis antes e após exposição a uma intervenção em fisioterapia. Metodologia: Neste estudo participaram 40 indivíduos com DCC de origem músculo-esquelética e causa não traumática, que foram expostos a uma intervenção em fisioterapia no Centro de Medicina de Reabilitação do Alcoitão e na Clinica AlcaisFisio, que cumpriram os critérios de inclusão e aceitarem participar livremente no mesmo. A recolha de dados realizou-se em dois momentos distintos, antes e após exposição à intervenção em fisioterapia. A catastrofização da dor foi avaliada por meio da Escala de Catastrofização da Dor (PCS), a intensidade da dor pela Escala Numérica da Dor (END), sendo realizada a medição da incapacidade funcional através do Neck Disability Index versão Portuguesa (NDI-PT). A análise estatística incluiu duas fases: fase descritiva e fase inferencial. Foram desenvolvidos modelos de regressão linear com vista a testar o poder preditivo da catastrofização da dor sobre a intensidade da dor e a incapacidade funcional. O nível de significância para o qual os valores se consideraram satisfatórios foi de p<0,05. O tratamento dos dados foi realizado no software PASW versão 18. Resultados: Observou-se que existe uma relação moderada, positiva e significativa, nos dois momentos de avaliação, entre a catastrofização da dor e a percepção da intensidade da dor (p<0,001), apresentando um poder preditivo de 27,9% e 46,7%, das pontuações da intensidade da dor, antes e após exposição à intervenção em fisioterapia, espectivamente. Observou-se que a catastrofização da dor tem uma relação forte, positiva e significativa com a incapacidade funcional, nos dois momentos de avaliação (p<0,001), predizendo 51,8% e 61,8%, das pontuações da incapacidade funcional, antes e após exposição à intervenção em fisioterapia, respectivamente. Conclusão: A catastrofização da dor é um factor psicossocial que apresenta relação moderada com a percepção da intensidade da dor, e forte com a incapacidade funcional auto-reportada por indivíduos com DCC de origem músculo-esquelética e causa não traumática, antes e após exposição à intervenção em fisioterapia. Os resultados do estudo sugerem, assim, uma importante influência da catastrofização da dor sobre a percepção da intensidade da dor e a incapacidade funcional em indivíduos com DCC, realçando o constructo multidimensional da DCC. ------------ABSTRACT: Background and Purpose: The influence of psychosocial factors, particularly, the pain catastrophizing, on pain intensity and functional disability in individuals with chronic neck pain (CNP) has been report among recent research literature. The first aim of this research was to verify the predictive value of pain catastrophizing on pain intensity and patient’s functional disability. Secondly it aimed to verify the stability of these relations before and after a physiotherapy treatment. Methodology: A sample of 40 subjects with CNP of musculoskeletal and non-traumatic causes was recruited from the patient’s list of two private clinics in Lisbon district following verification of the inclusion criteria. All participants agree to participate in the study and signed a consent form. Data was collected immediately before and after a period of physiotherapy treatment. Pain catastrophizing was assessed by the Pain Catastrophizing Scale (PCS-PT), patient perception of pain intensity was measured by the Numerical Rating Scale (NRS), and functional disability was measured through the Neck Disability Index (NDI-PT). Data was analyzed through descriptive and inferential statistics. Linear regression models were developed in order to test the predictive power of pain catastrophizing on pain intensity and functional disability. The minimal level of significance established was p<0,05. Data analysis was performed using the software PASW version 18. Results: A positive moderate relationship between pain catastrophizing and pain intensity was founded in both moments, before and after physiotherapy intervention, of data collection (p<0,001) with a predictive power of 27,9% and 46,7%, respectively. A positive strong relationship between pain catastrophizing and functional disability was founded in both moments, before and after physiotherapy intervention, of data collection (p<0,001), with a predictive power of 51,8% and 61,8%, respectively. Conclusion: Pain catastrophizing is a psychosocial factor that is correlated moderately with the perception of pain intensity and strongly with self-reported functionaldisability for individuals with CNP musculoskeletal origin and non-traumatic causes,before and after a physiotherapy intervention. The results of this study suggest that pain catastrophizing has an important influence on the report levels of pain intensity and functional disability in CNP patients. These results also emphasize the multidimensional nature of chronic neck pain.
Resumo:
Simple and rapid latex-based diagnostic tests have been used for detecting specific antigens or antibodies in several diseases. In this article, we present the preliminary results obtained with a latex agglutination test (LAT) for diagnosing neurocysticercosis by detection of antibodies in CSF. A total of 43 CSF samples were assayed by the LAT: 19 CSF samples from patients with neurocysticercosis and 24 CSF samples from patients with other neurologic disorders (neurosyphilis, n = 8; neurotoxoplasmosis, n = 3; viral meningitis, n = 4, chronic headache, n = 9). The LAT exhibited 89.5% sensitivity and 75% specificity. The use of LAT seems to be an additional approach for the screening of neurocysticercosis with advantage of simplicity and rapidity. Further studies could be performed using purified antigens and serum samples.
Resumo:
The present study was carried out to evaluate the Malar-CheckTM Pf test, an immunochromatographic assay that detects Plasmodium falciparum Histidine Rich Protein II, does not require equipment, and is easy and rapid to perform. In dilution assays performed to test sensitivity against known parasite density, Malar-CheckTMwere compared with thick blood smear (TBS), the gold standard for diagnosis. Palo Alto isolate or P. falciparum blood from patients with different parasitemias was used. The average cut-off points for each technique in three independent experiments were 12 and 71 parasites/mm³ (TBS and Malar-CheckTM, respectively). In the field assays, samples were collected from patients with fever who visited endemic regions. Compared to TBS, Malar-CheckTMyielded true-positive results in 38 patients, false-positive results in 3, true-negative results in 23, and false-negative result in 1. Malar-CheckTMperformed with samples from falciparum-infected patients after treatment showed persistence of antigen up to 30 days. Malar-CheckTM should aid the diagnosis of P. falciparum in remote areas and improve routine diagnosis even when microscopy is available. Previous P. falciparum infection, which can determine a false-positive test in cured individuals, should be considered. The prompt results obtained with the Malar-CheckTM for early diagnosis could avoid disease evolution to severe cases.
Resumo:
This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.
Resumo:
Radio link quality estimation is essential for protocols and mechanisms such as routing, mobility management and localization, particularly for low-power wireless networks such as wireless sensor networks. Commodity Link Quality Estimators (LQEs), e.g. PRR, RNP, ETX, four-bit and RSSI, can only provide a partial characterization of links as they ignore several link properties such as channel quality and stability. In this paper, we propose F-LQE (Fuzzy Link Quality Estimator, a holistic metric that estimates link quality on the basis of four link quality properties—packet delivery, asymmetry, stability, and channel quality—that are expressed and combined using Fuzzy Logic. We demonstrate through an extensive experimental analysis that F-LQE is more reliable than existing estimators (e.g., PRR, WMEWMA, ETX, RNP, and four-bit) as it provides a finer grain link classification. It is also more stable as it has lower coefficient of variation of link estimates. Importantly, we evaluate the impact of F-LQE on the performance of tree routing, specifically the CTP (Collection Tree Protocol). For this purpose, we adapted F-LQE to build a new routing metric for CTP, which we dubbed as F-LQE/RM. Extensive experimental results obtained with state-of-the-art widely used test-beds show that F-LQE/RM improves significantly CTP routing performance over four-bit (the default LQE of CTP) and ETX (another popular LQE). F-LQE/RM improves the end-to-end packet delivery by up to 16%, reduces the number of packet retransmissions by up to 32%, reduces the Hop count by up to 4%, and improves the topology stability by up to 47%.
Resumo:
The wide use of antibiotics in aquaculture has led to the emergence of resistant microbial species. It should be avoided/minimized by controlling the amount of drug employed in fish farming. For this purpose, the present work proposes test-strip papers aiming at the detection/semi-quantitative determination of organic drugs by visual comparison of color changes, in a similar analytical procedure to that of pH monitoring by universal pH paper. This is done by establishing suitable chemical changes upon cellulose, attributing the paper the ability to react with the organic drug and to produce a color change. Quantitative data is also enabled by taking a picture and applying a suitable mathematical treatment to the color coordinates given by the HSL system used by windows. As proof of concept, this approach was applied to oxytetracycline (OXY), one of the antibiotics frequently used in aquaculture. A bottom-up modification of paper was established, starting by the reaction of the glucose moieties on the paper with 3-triethoxysilylpropylamine (APTES). The so-formed amine layer allowed binding to a metal ion by coordination chemistry, while the metal ion reacted after with the drug to produce a colored compound. The most suitable metals to carry out such modification were selected by bulk studies, and the several stages of the paper modification were optimized to produce an intense color change against the concentration of the drug. The paper strips were applied to the analysis of spiked environmental water, allowing a quantitative determination for OXY concentrations as low as 30 ng/mL. In general, this work provided a simple, method to screen and discriminate tetracycline drugs, in aquaculture, being a promising tool for local, quick and cheap monitoring of drugs.
Resumo:
XIX Meeting of the Portuguese Electrochemical Society - XVI Iberic Meeting of Electrochemistry
Resumo:
A rapid test based on an immunochromatography assay - Determine Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.
Resumo:
The pathogenesis of the renal lesion upon envenomation by snakebite has been related to myolysis, hemolysis, hypotension and/or direct venom nephrotoxicity caused by the venom. Both primary and continuous cell culture systems provide an in vitro alternative for quantitative evaluation of the toxicity of snake venoms. Crude Crotalus vegrandis venom was fractionated by molecular exclusion chromatography. The toxicity of C. vegrandis crude venom, hemorrhagic, and neurotoxic fractions were evaluated on mouse primary renal cells and a continuous cell line of Vero cells maintained in vitro. Cells were isolated from murine renal cortex and were grown in 96 well plates with Dulbecco's Modified Essential Medium (DMEM) and challenged with crude and venom fractions. The murine renal cortex cells exhibited epithelial morphology and the majority showed smooth muscle actin determined by immune-staining. The cytotoxicity was evaluated by the tetrazolium colorimetric method. Cell viability was less for crude venom, followed by the hemorrhagic and neurotoxic fractions with a CT50 of 4.93, 18.41 and 50.22 µg/mL, respectively. The Vero cell cultures seemed to be more sensitive with a CT50 of 2.9 and 1.4 µg/mL for crude venom and the hemorrhagic peak, respectively. The results of this study show the potential of using cell culture system to evaluate venom toxicity.
Resumo:
This paper presents the TEC4SEA research infrastructure created in Portugal to support research, development, and validation of marine technologies. It is a multidisciplinary open platform, capable of supporting research, development, and test of marine robotics, telecommunications, and sensing technologies for monitoring and operating in the ocean environment. Due to the installed research facilities and its privileged geographic location, it allows fast access to deep sea, and can support multidisciplinary research, enabling full validation and evaluation of technological solutions designed for the ocean environment. It is a vertically integrated infrastructure, in the sense that it possesses a set of skills and resources which range from pure conceptual research to field deployment missions, with strong industrial and logistic capacities in the middle tier of prototype production. TEC4SEA is open to the entire scientific and enterprise community, with a free access policy for researchers affiliated with the research units that ensure its maintenance and sustainability. The paper describes the infrastructure in detail, and discusses associated research programs, providing a strategic vision for deep sea research initiatives, within the context of both the Portuguese National Ocean Strategy and European Strategy frameworks.