1000 resultados para GAMMA SOURCES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Evidence for the possible effect of vitamin E on head and neck cancers (HNCs) is limited. METHODS: We used individual-level pooled data from 10 case-control studies (5959 cases and 12 248 controls) participating in the International Head and Neck Cancer Epidemiology (INHANCE) consortium to assess the association between vitamin E intake from natural sources and cancer of the oral cavity/pharynx and larynx. Adjusted odds ratios (ORs) and 95% confidence intervals (CIs) were estimated using unconditional logistic regression models applied to quintile categories of nonalcohol energy-adjusted vitamin E intake. RESULTS: Intake of vitamin E was inversely related to oral/pharyngeal cancer (OR for the fifth vs the first quintile category=0.59, 95% CI: 0.49-0.71; P for trend <0.001) and to laryngeal cancer (OR=0.67, 95% CI: 0.54-0.83, P for trend <0.001). There was, however, appreciable heterogeneity of the estimated effect across studies for oral/pharyngeal cancer. Inverse associations were generally observed for the anatomical subsites of oral and pharyngeal cancer and within covariate strata for both sites. CONCLUSION: Our findings suggest that greater vitamin E intake from foods may lower HNC risk, although we were not able to explain the heterogeneity observed across studies or rule out certain sources of bias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, the fusion of a stochastic metaheuristic as Simulated Annealing (SA) with classical criteria for convergence of Blind Separation of Sources (BSS), is shown. Although the topic of BSS, by means of various techniques, including ICA, PCA, and neural networks, has been amply discussed in the literature, to date the possibility of using simulated annealing algorithms has not been seriously explored. From experimental results, this paper demonstrates the possible benefits offered by SA in combination with high order statistical and mutual information criteria for BSS, such as robustness against local minima and a high degree of flexibility in the energy function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ingvaldsen et al. comment on our study assessing global fish interchanges between the North Atlantic and Pacific oceans for more than 500 species during the entire 21st century. They propose that discrepancies between our model projections and observed data for cod in the Barents Sea are the result of the choice of Atmosphere-Ocean General Circulation Models (AOGCMs). We address this assertion here, re-running the cod model with additional observation data from the Barents Sea1, 3, and show that the lack of open-access, archived data for the Barents Sea was the primary cause of local prediction mismatch. This finding recalls the importance of systematic deposit of biodiversity data in global databases

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wide-range spectral coverage of blazar-type active galactic nuclei is of paramount importance for understanding the particle acceleration mechanisms assumed to take place in their jets. The Major Atmospheric Gamma Imaging Cerenkov (MAGIC) telescope participated in three multiwavelength (MWL) campaigns, observing the blazar Markarian (Mkn) 421 during the nights of April 28 and 29, 2006, and June 14, 2006. Aims. We analyzed the corresponding MAGIC very-high energy observations during 9 nights from April 22 to 30, 2006 and on June 14, 2006. We inferred light curves with sub-day resolution and night-by-night energy spectra. Methods. MAGIC detects γ-rays by observing extended air showers in the atmosphere. The obtained air-shower images were analyzed using the standard MAGIC analysis chain. Results. A strong γ-ray signal was detected from Mkn 421 on all observation nights. The flux (E > 250 GeV) varied on night-by-night basis between (0.92±0.11) × 10-10 cm-2 s-1 (0.57 Crab units) and (3.21±0.15) × 10-10 cm-2 s-1 (2.0 Crab units) in April 2006. There is a clear indication for intra-night variability with a doubling time of 36± min on the night of April 29, 2006, establishing once more rapid flux variability for this object. For all individual nights γ-ray spectra could be inferred, with power-law indices ranging from 1.66 to 2.47. We did not find statistically significant correlations between the spectral index and the flux state for individual nights. During the June 2006 campaign, a flux substantially lower than the one measured by the Whipple 10-m telescope four days later was found. Using a log-parabolic power law fit we deduced for some data sets the location of the spectral peak in the very-high energy regime. Our results confirm the indications of rising peak energy with increasing flux, as expected in leptonic acceleration models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microquasars are stellar x-ray binaries that behave as a scaled down version of extragalactic quasars. The star LS 5039 is a new microquasar system with apparent persistent ejection of relativistic plasma at a 3 kiloparsec distance from the sun. It may also be associated with a gamma-ray source discovered by the Energetic Gamma Ray Experiment Telescope (EGRET) on board the COMPTON-Gamma Ray Observatory satellite. Before the discovery of LS 5039, merely a handful of microquasars had been identified in the Galaxy, and none of them was detected in high-energy gamma-rays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context. There are a number of very high energy sources in the Galaxy that remain unidentified. Multi-wavelength and variability studies, and catalogue searches, are powerful tools to identify the physical counterpart, given the uncertainty in the source location and extension. Aims. This work carries out a thorough multi-wavelength study of the unidentified, very high energy source HESS J1858+020 and its environs. Methods. We have performed Giant Metrewave Radio Telescope observations at 610 MHz and 1.4 GHz to obtain a deep, low-frequency radio image of the region surrounding HESS J1858+020. We analysed archival radio, infrared, and X-ray data as well. This observational information, combined with molecular data, catalogue sources, and a nearby Fermi gamma-ray detection of unidentified origin, are combined to explore possible counterparts to the very high energy source. Results. We provide with a deep radio image of a supernova remnant that might be related to the GeV and TeV emission in the region. We confirm the presence of an H ii region next to the supernova remnant and coincident with molecular emission. A potential region of star formation is also identified. We identify several radio and X-ray sources in the surroundings. Some of these sources are known planetary nebulae, whereas others may be non-thermal extended emitters and embedded young stellar objects. Three old, background Galactic pulsars also neighbour HESS J1858+020 along the line of sight. Conclusions. The region surrounding HESS J1858+020 is rich in molecular structures and non-thermal objects that may potentially be linked to this unidentified very high energy source. In particular, a supernova remnant interacting with nearby molecular clouds may be a good candidate, but a star forming region, or a non-thermal radio source of yet unclear nature, may also be behind the gamma-ray source. The neighbouring pulsars, despite being old and distant, cannot be discarded as candidates. Further observational studies are needed, however, to narrow the search for a counterpart to the HESS source.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context.Massive stars form in dense and massive molecular cores. The exact formation mechanism is unclear, but it is possible that some massive stars are formed by processes similar to those that produce the low-mass stars, with accretion/ejection phenomena occurring at some point of the evolution of the protostar. This picture seems to be supported by the detection of a collimated stellar wind emanating from the massive protostar IRAS 16547-4247. A triple radio source is associated with the protostar: a compact core and two radio lobes. The emission of the southern lobe is clearly non-thermal. Such emission is interpreted as synchrotron radiation produced by relativistic electrons locally accelerated at the termination point of a thermal jet. Since the ambient medium is determined by the properties of the molecular cloud in which the whole system is embedded, we can expect high densities of particles and infrared photons. Because of the confirmed presence of relativistic electrons, inverse Compton and relativistic Bremsstrahlung interactions are unavoidable. Aims.We aim to make quantitative predictions of the spectral energy distribution of the non-thermal spots generated by massive young stellar objects, with emphasis on the particular case of IRAS 16547-4247. Methods.We study the high-energy emission generated by the relativistic electrons which produce the non-thermal radio source in IRAS 16547-4247. We also study the result of proton acceleration at the terminal shock of the thermal jet and make estimates of the secondary gamma rays and electron-positron pairs produced by pion decay. Results.We present spectral energy distributions for the southern lobe of IRAS 16547-4247, for a variety of conditions. We show that high-energy emission might be detectable from this object in the gamma-ray domain. The source may also be detectable in X-rays through long exposures with current X-ray instruments. Conclusions.Gamma-ray telescopes such as GLAST, and even ground-based Cherenkov arrays of new generation can be used to study non-thermal processes occurring during the formation of massive stars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le traitement de radiochirurgie par Gamma Knife (GK) est utilisé de plus en plus souvent comme une alternative à la microchirurgie conventionnelle pour le traitement des pathologies neurochirurgicales intracrâniennes. Il s'agit d'irradier en dose unique et à haute énergie, en condition stéréotaxique et à l'aide d'une imagerie multimodale (imagerie par résonance magnétique [IRM], tomodensitométrie et éventuellement artériographie). Le GK a été inventé par le neurochirurgien suédois Lars Leksell, qui a réalisé le premier ciblage du nerf trijumeau en 1951, sur la base d'une radiographie standard. Depuis, les progrès de l'informatique et de la robotique ont permis d'améliorer la technique de radiochirurgie qui s'effectue actuellement soit par accélérateur linéaire de particules monté sur un bras robotisé (Novalis®, Cyberknife®), soit par collimation de près de 192 sources fixes (GK). La principale indication radiochirurgicale dans le traitement de la douleur est la névralgie du nerf trijumeau. Les autres indications, plus rares, sont la névralgie du nerf glossopharyngien, l'algie vasculaire de la face, ainsi qu'un traitement de la douleur d'origine cancéreuse par hypophysiolyse. Gamma Knife surgery (GKS) is widely used as an alternative to open microsurgical procedures as noninvasive treatment of many intracranial conditions. It consists of delivering a single dose of high energy in stereotactic conditions, and with the help of a multimodal imaging (e.g., magnetic resonance imaging [MRI], computer tomography, and eventually angiography). The Gamma Knife (GK) was invented by the Swedish neurosurgeon Lars Leksell who was the first to treat a trigeminal neuralgia sufferer in 1951 using an orthogonal X-ray tube. Since then, the progresses made both in the field of informatics and robotics have allowed to improve the radiosurgical technique, which is currently performed either by a linear accelerator of particles mounted on a robotized arm (Novalis®, Cyberknife®), or by collimation of 192 fixed Co-60 sources (GK). The main indication of GKS in the treatment of pain is trigeminal neuralgia. The other indications, less frequent, are: glossopharyngeal neuralgia, cluster headache, and hypophysiolyse for cancer pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intravascular brachytherapy with beta sources has become a useful technique to prevent restenosis after cardiovascular intervention. In particular, the Beta-Cath high-dose-rate system, manufactured by Novoste Corporation, is a commercially available 90Sr 90Y source for intravascular brachytherapy that is achieving widespread use. Its dosimetric characterization has attracted considerable attention in recent years. Unfortunately, the short ranges of the emitted beta particles and the associated large dose gradients make experimental measurements particularly difficult. This circumstance has motivated the appearance of a number of papers addressing the characterization of this source by means of Monte Carlo simulation techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Gamma Knife surgery (GKS) for vestibular schwannomas (VS) has a long-term clinical and scientific track record. After a period of de-escalation of dose prescription, results show a high rate of tumor control with improvement of clinical outcome (less than 1% facial palsy, 50-70% hearing preservation). Currently, there is controversial data about the active early treatment of intracanalicular (Koos I) VS. Methods: We prospectively analyzed 208 VS, focusing on 42 Koos I patients treated with GKS as first intention in Lausanne University Hospital, between July 2010 and February 2015. We concentrated on patient, tumor, and dosimetric characteristics. Special attention was given on the dose to the cochlea and its impact in maintaining serviceable hearing. Results: The mean follow-up period was 1.7 years (range 0.6-4.2). Twenty-six (61.9%) were females and 16 (38.1%) males. Preoperative serviceable hearing was present in 33 (78.57%) patients. The mean maximal diameter was 7.7 (5-10). The median target volume at the moment of GKS was 90 mm3 (range 17-317). The median prescription isodose volume was 118 mm3 (range 37-603). The median marginal dose administrated was 12 Gy (range 11-12). The median number of shots was 2 (range 1-9). The median isodose prescription was 50% (range 45-80%). The median maximal dose received by the cochlea in patients in GR class 1 and 2 was 4.2 Gy (mean 4.4 Gy, range 1.8-7.6). Our preliminary results showed 98% tumor control, with 30% shrinkage on MRI. The actuarial probability of keeping the same audition class for those with functional hearing at GKS was 80% at 3 years; the probability of keeping a functional hearing was more than 90%. A paraclinical evolution (on MRI and/or audiometry) at the time diagnosis, before GKS, was associated with a less good prognosis (p < 0.05). Conclusions: Our preliminary data suggest that Koos I patients should be treated early with GKS, before tumor growth, and/or hearing deterioration, as they have the highest probability of hearing preservation. The results in terms of functional outcome seemed comparable to, or even better than, the other Koos classes (i.e., larger lesions).