903 resultados para Femoral shaft Fractures


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report clinical features associated with iatrogenic peripheral nerve injury in dogs and cats admitted (1997-2006) to a referral teaching hospital. STUDY DESIGN: Retrospective study. ANIMALS: Dogs (n=18), 9 cats. METHODS: Patients had acute signs of monoparesis attributable to sciatic nerve dysfunction that developed after treatment. Neurologic examination and electrodiagnostic testing were performed. Surgical therapy was used for nerve entrapment and delayed reconstructive surgery used in other cases. RESULTS: Of 27 nerve injuries, 25 resulted from surgery (18 with treatment of pelvic injuries). Iliosacral luxation repair resulted in tibial (4 cats) and peroneal (3 dogs) nerve dysfunction. Other causes were intramedullary pinning of femoral fractures (3), other orthopedic surgery (cemented hip prosthesis [2] and tibial plateau-leveling osteotomy [1]), and perineal herniorrhaphy [1]. Nerve injury occurred after intramuscular injection (1 cat, 1 dog). Immediate surgical treatment was removal of intramedullary nails, extruded cement, or entrapping suture. Delayed nerve transplantation was performed in 2 dogs. Within 1 year, 13 patients recovered completely, clinical improvement occurred in 7, and there was no improvement in 7. Five of the 7 dogs that did not recover had acetabular or ilium fracture. CONCLUSION: Iatrogenic sciatic nerve injury occurred most commonly during treatment of pelvic orthopedic diseases and had a poor prognosis. Clinical variation in sciatic nerve dysfunction in dogs and cats can be explained by species anatomic differences. CLINICAL RELEVANCE: Iatrogenic sciatic nerve injury leads to severely debilitating locomotor dysfunction with an uncertain prognosis for full-functional recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic and therapeutic interventions following dental injuries are not part of the routine practice in the dental office. Quite often, these patients are emergency cases who seek treatment after normal office hours. The objective of this and the future papers is to present the current treatment concepts in dental traumatology at the School of Dental Medicine, University of Berne. The fruitful cooperation in the field of dental traumatology between the Department of Oral Surgery and Stomatology, and the Department of Conservative Dentistry (including pediatric dentistry and endodontology), is based on the interdisciplinary approach that has been established four years ago. Following discussion and evaluation of such treated cases, and considering current clinical and experimental studies, the said concepts have been worked out. The present paper describes the therapeutic approach for root fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crown fractures and luxations occur most frequently of all dental injuries. An appropriate treatment plan after an injury is important for a good prognosis. Guidelines are useful for delivering the best care possible in an efficient manner. The International Association of Dental Traumatology (IADT) has developed a consensus statement after a review of the dental literature and group discussions. Experienced researchers and clinicians from various specialties were included in the group. In cases where the data did not appear conclusive, recommendations were based on the consensus opinion of the IADT board members. The guidelines represent the current best evidence, based on literature research and professional opinion. In this first article of three, the IADT Guidelines for management of fractures and luxations of permanent teeth will be presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: The aim of this study was to analyse the character of assault-related facial fractures in central Switzerland and to compare their prevalence with the data presented in similar reports from other countries. MATERIAL: The present study comprised 65 patients with assault-related maxillofacial fractures treated in the Department of Cranio-Maxillofacial Surgery, University Hospital of Bern between 2000 and 2002. METHODS: The mechanism, the causes of the injuries and the location of the fractures were analysed by reviewing emergency and hospital records. Concomitant injuries were also studied. RESULTS: The mean age of the patients was 33 years with the largest group being below 25 years. The male-to-female ratio was 56:9. The most common causes of assault-related injuries were fights, most frequently facial blows, accounting for 92.5% of all patients. Seventy-six per cent of the fractures occurred in the middle and upper facial skeleton with a predominance of 2:1 for the left side. In 39 patients (60%) surgery was necessary, with a mean hospital stay of 3.3 days. Thirty-five patients (54%) had concomitant injuries. Alcohol and drug abuse was found in 15 patients (23%). CONCLUSION: It seems that mostly young men suffer assault-related maxillofacial injuries. A contributing factor to the increased disposition for violence could be alcohol and drug abuse. Therefore, national prevention programmes for alcohol or drug abuse and addiction might have a positive effect on reducing the incidence of assault-related maxillofacial injuries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The inevitable detachment of tendons and the loss of the forefoot in Chopart and Lisfranc amputations result in equinus and varus of the residual foot. In an insensate foot these deformities can lead to keratotic lesions and ulcerations. The currently available prostheses cannot safely counteract the deforming forces and the resulting complications. METHODS: A new below-knee prosthesis was developed, combining a soft socket with a rigid shaft. The mold is taken with the foot in the corrected position. After manufacturing the shaft, the lateral third of the circumference of the shaft is cut away and reattached distally with a hinge, creating a lateral flap. By closing this flap the hindfoot is gently levered from the varus position into valgus. Ten patients (seven amputations at the Chopart-level, three amputations at the Lisfranc-level) with insensate feet were fitted with this prosthesis at an average of 3 (range 1.5 to 9) months after amputation. The handling, comfort, time of daily use, mobility, correction of malposition and complications were recorded to the latest followup (average 31 months, range 24 to 37 months after amputation). RESULTS: Eight patients evaluated the handling as easy, two as difficult. No patient felt discomfort in the prosthesis. The average time of daily use was 12 hours, and all patients were able to walk. All varus deformities were corrected in the prosthesis. Sagittal alignment was kept neutral. Complications were two minor skin lesions and one small ulcer, all of which responded to conservative treatment, and one ulcer healed after debridement and lengthening of the Achilles tendon. CONCLUSIONS: The "flap-shaft" prosthesis is a valuable option for primary or secondary prosthetic fitting of Chopart-level and Lisfranc-level amputees with insensate feet and flexible equinus and varus deformity at risk for recurrent ulceration. It provided safe and sufficient correction of malpositions and enabled the patients to walk as much as their general condition permitted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The stability of 2 fixation techniques for the tuberosities in patients with 3- or 4-part proximal humerus fractures treated with hemiarthroplasties was compared. DESIGN: Retrospective review of a nonrandomized sequential series of patients. SETTING: Level I university orthopaedic surgery department. PATIENTS: A consecutive series of 58 patients (average age, 64 years) from 1990 to 1999 with 3- and 4-part fractures of the proximal humerus. INTERVENTION: In group 1, 31 patients were treated with either a Neer or Aequalis shoulder prosthesis using nonabsorbable sutures and no bone graft for the reattachment of the tuberosities. In group 2, 27 patients were treated with either an Aequalis or Epoca shoulder prosthesis and a combination of cable fixation and bone grafting. MAIN OUTCOME MEASUREMENTS: At follow-up (average, 32 months), radiographs were taken to confirm tuberosity fixation or degree of displacement or resorption. Functional outcome was assessed by the Constant-Murley Score. RESULTS: Significantly more dislocated tuberosities were found radiographically in group 1 (10 of 13 in total, P = 0.011), and significantly more tuberosities were resorbed in group 1 (9 of 12 in total, P = 0.012). Significant differences in functional results among healed versus failed tuberosity fixation were observed for activity of daily living (P = 0.05), range of motion (P = 0.002), strength (P = 0.01), the total score (P = 0.008), and the passive rotation amplitude (P = 0.04). CONCLUSION: In hemiarthroplasties for proximal humeral fractures, the reattachment of the tuberosities with cable wire and bone grafting gives consistently better radiographic and functional results than with suture fixation alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic and therapeutic interventions following dental injuries are not part of the routine practice in the dental office. Quite often, these patients are emergency cases who seek treatment after normal office hours. The objective of this and the future papers is to present the current treatment concepts in dental traumatology at the School of Dental Medicine, University of Berne. The fruitful cooperation in the field of dental traumatology between the Department of Oral Surgery and Stomatology, and the Department of Conservative Dentistry (including pediatric dentistry and endodontology) is based on the interdisciplinary approach that has been established five years ago. Following discussion and evaluation of such treated cases, and considering current clinical and experimental references, the said concepts have been worked out. The present paper describes the therapeutic concepts of crown fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trousseau Syndrome is a paraneoplastic procoagulant phenomenon. Heparin-induced thrombocytopenia (HIT) is a rare complication of anticoagulation with heparin. To our knowledge, the coincidence of the two has not been reported so far. We report a case of an acute thrombosis of the left femoral artery and distal leg arteries in a patient with an otherwise normal cardiovascular status. Endovascular revascularization attempts using mechanical rotational thrombectomy catheter, aspiration and local thrombolysis were unsuccessful. Progressive coagulation along the intra-arterial catheter was seen. Surgical thrombectomy of the femoral-pedal axis was successful, but the patient developed an immune-mediated HIT postoperatively. An adenocarcinoma of the colon was the likely cause for the initial arterial thrombosis, and probably adversely affected endovascular revascularization attempts. Subsequent HIT with microvascular thrombosis worsened ischemic damage leading to a below knee-amputation, despite patent large vessels. Compared to venous thrombosis, arterial thrombosis is a rare manifestation of Trousseau syndrome. The coincidence of it with HIT is even rarer. There may be a causal relationship between the two.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Serum protein S-100B determinations have been widely proposed in the past as markers of traumatic brain injury and used as a predictor of injury severity and outcome. The purpose of this prospective observational case series was therefore to determine S-100B serum levels in patients with isolated injuries to the back. METHODS: Between 1 February and 1 May 2008, serum samples for S-100B analysis were obtained within 1 hour of injury from 285 trauma patients. All patients with a head injury, polytrauma, and intoxicated patients were excluded to select isolated injuries to the spine. 19 patients with isolated injury of the back were included. Serum samples for S-100B analysis and CT spine were obtained within 1 hours of injury. RESULTS: CT scans showed vertebral fractures in 12 of the 19 patients (63%). All patients with fractures had elevated S-100B levels. Amongst the remaining 7 patients without a fracture, only one patient with a severe spinal contusion had an S-100B concentration above the reference limit. The mean S-100B value of the group with fractures was more than 4 times higher than in the group without fractures (0.385 vs 0.087 mug/L, p = 0.0097). CONCLUSION: Our data, although limited due to a very small sample size, suggest that S-100B serum levels might be useful for the diagnosis of acute vertebral body and spinal cord injury with a high negative predictive power. According to the literature, the highest levels of serum S-100B are found when large bones are fractured. If a large prospective study confirms our findings, determining the S-100B level may contribute to more selective use of CT and MRI in spinal trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the introduction of strong discontinuities into a mesh will be developed. This method, applicable to a number of eXtended Finite Element Methods (XFEM) with intra-element strong discontinuities will be demonstrated with one specific method: the Generalized Cohesive Element (GCE) method. The algorithm utilizes a subgraph mesh representation which may insert the GCE either adaptively during the course of the analysis or a priori. Using this subgraphing algorithm, the insertion time is O(n) to the number of insertions. Numerical examples are presented demonstrating the advantages of the subgraph insertion method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate fracture patterns in bicondylar tibial plateau fractures and their impact on treatment strategy. DESIGN: Prospective data analysis with documentation of initial injury and treatment strategy, computed tomography scans, conventional x-rays, long-term evaluation of radiographs, and functional assessments. SETTING: Level 1 regional trauma center. PATIENTS: Prospective data acquisition of 14 consecutive patients (10 male and 4 female) with a bicondylar tibial plateau fracture (AO Type C). INTERVENTION: Application of a stepwise reconstruction strategy of the tibial plateau starting with the reposition and fixation of the posteromedial split fragment using a 3.5 buttress plate, followed by reposition and grafting of the lateral compartment and lateral fixation with a 3.5 plate in 90 degree to the medial fixation device. MAIN OUTCOME MEASUREMENTS: All patients were evaluated with full-length standing film, standardized x-rays, Lysholm score for functional assessment, and patient's self-appraisal. RESULTS: Most of the complex bicondylar fractures follow a regular pattern in that the medial compartment is split in a mediolateral direction with a posteromedial main fragment, combined with various amounts of multifragmental lateral compartment depression. The technique introduced allows for accurate and stable reduction and fixation of this fracture type. The final Lysholm knee score showed an average of 83.5 points (range: 64.5-92). CONCLUSIONS: Complex bicondylar tibial plateau fractures follow a regular pattern, which is not represented in existing 2-dimensional fracture classifications. A 2-incision technique starting with the reduction of the posteromedial edge results in accurate fracture reduction with low complication rates and excellent knee function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extended lateral L-shaped approach for the treatment of displaced intra-articular fractures of the calcaneum may be complicated by wound infection, haematoma, dehiscence and injury to the sural nerve. In an effort to reduce the risk of problems with wound healing a technique was developed that combined open reduction and fixation of the joint fragments and of the anterior process with percutaneous reduction and screw fixation of the tuberosity. A group of 24 patients with unilateral isolated closed Sanders type II and III fractures was treated using this technique and compared to a similar group of 26 patients managed by the extended approach and lateral plating. The operation was significantly shorter (p < 0.001) in the first group, but more minor secondary procedures and removal of heel screws were necessary. There were no wound complications in this group, whereas four minor complications occurred in the second group. The accuracy and maintenance of reduction, and ultimate function were equivalent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To present the functional and radiographic outcome 1 and 6 years after application of a new intramedullary fixation device for proximal humerus fractures. DESIGN: Retrospective case series. SETTING: Level II orthopaedic surgery hospital. PATIENTS: Twenty-six consecutive patients (average age 68.9 years) with 2-, 3- and 4-part fractures of the proximal humerus were operated at a single institution. Follow-up was performed after 1 year (26 patients) and 6 years (16 patients). INTERVENTION: All patients were treated with closed reduction and intramedullary helix wires. MAIN OUTCOME MEASUREMENTS: The Constant-Murley score and the University of California Los Angeles (UCLA) score. Clinical complications and radiological posttraumatic arthritis were recorded. RESULTS: The average Constant-Murley score was 70.3 (points) and 70.7 after 1 and 6 years, respectively; the average UCLA score was 27.2 and 31.5 after 1 and 6 years, respectively. Major complications were 4 revisions for 3 secondary fragment displacements and 1 nonunion with partial avascular osteonecrosis in the first postoperative year. Complications were found predominantly in 4-part fractures (3/5, 60%). There were no further complications or progressive posttraumatic arthritis up to 6 years following surgery. CONCLUSION: The helix wire is well suited for displaced or unstable 2- and 3-part proximal humerus fractures. Adequate functional outcome, a low number of implant displacements, a low number of application morbidity, and infrequent implant removals were recorded. The use of this device is not recommended for 4-part fractures.