926 resultados para FEMORAL-HEAD
Resumo:
[EN] Head and neck cancer is treated mainly by surgery and radiotherapy. Normal tissue toxicity due to x-ray exposure is a limiting factor for treatment success. Many efforts have been employed to develop predictive tests applied to clinical practice. Determination of lymphocyte radio-sensitivity by radio-induced apoptosis arises as a possible method to predict tissue toxicity due to radiotherapy. The aim of the present study was to analyze radio-induced apoptosis of peripheral blood lymphocytes in head and neck cancer patients and to explore their role in predicting radiation induced toxicity. Seventy nine consecutive patients suffering from head and neck cancer, diagnosed and treated in our institution, were included in the study. Toxicity was evaluated using the Radiation Therapy Oncology Group scale. Peripheral blood lymphocytes were isolated and irradiated at 0, 1, 2 and 8 Gy during 24 hours. Apoptosis was measured by flow cytometry using annexin V/propidium iodide. Lymphocytes were marked with CD45 APC-conjugated monoclonal antibody. Radiation-induced apoptosis increased in order to radiation dose and fitted to a semi logarithmic model defined by two constants: α and β. α, as the origin of the curve in the Y axis determining the percentage of spontaneous cell death, and β, as the slope of the curve determining the percentage of cell death induced at a determined radiation dose, were obtained. β value was statistically associated to normal tissue toxicity in terms of severe xerostomia, as higher levels of apoptosis were observed in patients with low toxicity (p = 0.035; Exp(B) 0.224, I.C.95% (0.060-0.904)). These data agree with our previous results and suggest that it is possible to estimate the radiosensitivity of peripheral blood lymphocytes from patients determining the radiation induced apoptosis with annexin V/propidium iodide staining. β values observed define an individual radiosensitivity profile that could predict late toxicity due to radiotherapy in locally advanced head and neck cancer patients. Anyhow, prospective studies with different cancer types and higher number of patients are needed to validate these results.
Resumo:
Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.
Resumo:
Le vene giugulari interne sembrano essere la via principale attraverso cui il sangue defluisce dal cervello verso il cuore, quando siamo in posizione supina. Nel 2008 il professor Paolo Zamboni ha scoperto che una diminuzione dell'attività giugulare può portare allo sviluppo di una condizione emodinamica chiamata CCSVI. Questa può causare ipossia, ritardi nella perfusione cerebrale e riduzione del drenaggio dei cataboliti, oltre ad un'attivazione infiammatoria delle piccole vene e dei tessuti vicini. Questa condizione è stata da subito associata alla sclerosi multipla e su questo argomento si sono dibattuti molti gruppi di ricerca. Inoltre, altre patologie sembrano essere associate alla CCSVI, come il morbo di Parkinson, l'Alzheimer e la sindrome di Meniere. Proprio quest'ultima è uno degli argomenti che attualmente interessa di più il gruppo di lavoro in cui mi sono inserita. Questa patologia comporta problemi uditivi, come sordità e tinnito, vertigini e nausea. Il gruppo Vascolar Disease Center (VDC) dell'Università di Ferrara ha previsto per l'anno 2015 uno studio multicentrico, in cui si cercherà di verificare la correlazione tra CCSVI e sindrome di Meniere. La mia tesi fa parte di un studio preliminare a quello multicentrico. All'inizio del lavoro mi sono dedicata ad un'analisi critica di un modello emodinamico per la quantificazione dei flussi sanguigni: il modello BMC, pubblicato nel 2013 dal gruppo VDC, effettuando in parallelo una ricerca bibliografica sullo stato dell'arte in materia. In seguito ho cominciato a studiare off-line diversi studi patologici e fisiologici, in modo da prendere confidenza con gli strumenti e con le metodologie da utilizzare. Sono stata poi coinvolta dal gruppo VDC per partecipare attivamente al miglioramento del protocollo legato al modello BMC. Infine ho analizzato, con due metodologie differenti, 35 studi effettuati su pazienti otorinolaringoiatrici. Con i risultati ottenuti ho potuto effettuare diverse analisi statistiche al fine di verificare l'equivalenza delle due metodologie. L'obiettivo ultimo era quello di stabilire quale delle due fosse la tecnica migliore da utilizzare, successivamente, nello studio multicentrico.
Resumo:
We performed a histopathologic analysis to assess the extent of the extracapsular extension (ECE) beyond the capsule of metastatic lymph nodes (LN) in head and neck cancer to determine appropriate clinical target volume (CTV) expansions.
Resumo:
During short-term postural changes, the factors determining the amplitude of intracranial pulse pressure (ICPPA) remain constant, except for cerebrovascular resistance (CVR). Therefore, it may be possible to draw conclusions from the ICPPA onto the cerebrovascular resistance (CVR) and thus the relative change in cerebral perfusion pressure (CPP).
Resumo:
Small lymph nodes (LN) show evidence of extracapsular extension (ECE) in a significant number of patients. This study was performed to determine the impact of ECE in LN 7 mm as compared with ECE in larger LN.
Resumo:
Traumatic posterior dislocation of the hip associated with a fracture of the posterior acetabular wall and of the neck of the femur is a rare injury. A 29-year-old man presented at a level 1 trauma centre with a locked posterior dislocation of the right hip, with fractures of the femoral neck and the posterior wall of the acetabulum after a bicycle accident. An attempted closed reduction had failed. This case report describes in detail the surgical management and the clinical and radiological outcome. Open reduction and fixation with preservation of the intact retinaculum was undertaken within five hours of injury with surgical dislocation of the hip and a trochanteric osteotomy. Two years after operation the function of the injured hip was good. Plain radiographs and MR scans showed early signs of osteoarthritis with some loss of joint space but no evidence of avascular necrosis. The patient had begun skiing and hiking again. The combination of fractures of the neck of the femur and of the posterior wall of the acetabulum hampers closed reduction of a posterior dislocation of the hip. Surgical dislocation of the hip with trochanteric flip osteotomy allows controlled open reduction of the fractures, with inspection of the hip joint and preservation of the vascular supply.
Resumo:
Computer modeling of 10 patients' computed tomographic scans was used to study the variables affecting hip arthroplasty range of motion before bony impingement (ROMBI) including acetabular offset and height, femoral offset, height and anteversion, and osteophyte removal. The ROMBI was compared with the ROM before component impingement and the native hip ROM. The ROMBI decreased with decreased total offset and limb shortening. Acetabular offset and height had a greater effect on ROMBI than femoral offset and height. The ROMBI lost with decreased acetabular offset was not fully recoverable with an increase in femoral offset or osteophyte removal. Bony impingement increased and component impingement decreased with decreased acetabular offset and increased head diameter.
Resumo:
The most widely accepted treatment for comminuted fractures of the radial head is either the excision or open reduction and internal fixation. The purpose of the present study is to evaluate the value of an 'on-table' reconstruction technique in severely comminuted fractures of the radial head. In this study, two patients with a Mason type-III and four patients with a Mason type-IV radial-head fracture were treated with 'on-table' reconstruction and fixation using low-profile mini-plates. After a mean follow-up of 112 months (47-154 months), the mean elbow motion was 0-6-141 degrees extension flexion with 79 degrees of pronation and 70 degrees of supination. The mean Broberg and Morrey functional rating score was 97.0 points, the Mayo Elbow Performance Index was 99.2 points and the mean Disabilities of the Arm, Shoulder, and Hand (DASH) Outcome Measure score was 1.94 points. One patient had symptoms of degenerative changes, with a slight joint-space narrowing. There were no radiographic signs of devitalisation at final examination. Comminuted fractures of the radial head, which would otherwise require excision, can be successfully treated with an 'on-table' reconstruction technique.
Resumo:
Residual acetabular dysplasia of the hip in most patients can be corrected by periacetabular osteotomy. However, some patients have intraarticular abnormalities causing insufficient coverage, containment or congruency after periacetabular osteotomy, or extraarticular abnormalities that limit either acetabular correction or hip motion. For these patients, we believe an additional proximal femoral osteotomy can improve coverage, containment, congruency and/or motion.
Resumo:
There is emerging evidence that even mild slipped capital femoral epiphysis leads to early articular damage. Therefore, we have begun treating patients with mild slips and signs of impingement with in situ pinning and immediate arthroscopic osteoplasty. DESCRIPTION OF TECHNIQUES: Surgery was performed using the fracture table. After in situ pinning and diagnostic arthroscopy, peripheral compartment access was obtained and head-neck osteoplasty was completed.