927 resultados para Error correction coding


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Nucleus accumbens (Nacc) has been proposed to act as a limbic-motor interface. Here, using invasive intraoperative recordings in an awake patient suffering from obsessive-compulsive disease (OCD), we demonstrate that its activity is modulated by the quality of performance of the subject in a choice reaction time task designed to tap action monitoring processes. Action monitoring, that is, error detection and correction, is thought to be supported by a system involving the dopaminergic midbrain, the basal ganglia, and the medial prefrontal cortex. In surface electrophysiological recordings, action monitoring is indexed by an error-related negativity (ERN) appearing time-locked to the erroneous responses and emanating from the medial frontal cortex. In preoperative scalp recordings the patient's ERN was found to be signifi cantly increased compared to a large (n = 83) normal sample, suggesting enhanced action monitoring processes. Intraoperatively, error-related modulations were obtained from the Nacc but not from a site 5 mm above. Importantly, crosscorrelation analysis showed that error-related activity in the Nacc preceded surface activity by 40 ms. We propose that the Nacc is involved in action monitoring, possibly by using error signals from the dopaminergic midbrain to adjust the relative impact of limbic and prefrontal inputs on frontal control systems in order to optimize goal-directed behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The directional consistency and skew-symmetry statistics have been proposed as global measurements of social reciprocity. Although both measures can be useful for quantifying social reciprocity, researchers need to know whether these estimators are biased in order to assess descriptive results properly. That is, if estimators are biased, researchers should compare actual values with expected values under the specified null hypothesis. Furthermore, standard errors are needed to enable suitable assessment of discrepancies between actual and expected values. This paper aims to derive some exact and approximate expressions in order to obtain bias and standard error values for both estimators for round-robin designs, although the results can also be extended to other reciprocal designs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a fast method for the determination of the total sugar levels in samples of raw coffee was developed using the near infrared spectroscopy technique and multivariate regression. The sugar levels were initially obtained using gravimety as the reference method. Later on, the regression models were built from the near infrared spectra of the coffee samples. The original spectra were pre-treated according to the Kubelka-Munk transformation and multiplicative signal correction. The proposed analytical method made possible the direct determination of the total sugar levels in the samples with an error lower by 8% with respect to the conventional methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Entrevista con Manuel Villegas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a new mathematical equation correction approach for overcoming spectral and transport interferences was proposed. The proposal was applied to eliminate spectral interference caused by PO molecules at the 217.0005 nm Pb line, and the transport interference caused by variations in phosphoric acid concentrations. Correction may be necessary at 217.0005 nm to account for the contribution of PO, since Atotal217.0005 nm = A Pb217.0005 nm + A PO217.0005 nm. This may be easily done by measuring other PO wavelengths (e.g. 217.0458 nm) and calculating the relative contribution of PO absorbance (A PO) to the total absorbance (Atotal) at 217.0005 nm: A Pb217.0005 nm = Atotal217.0005 nm - A PO217.0005 nm = Atotal217.0005 nm - k (A PO217.0458 nm). The correction factor k is calculated from slopes of calibration curves built up for phosphorous (P) standard solutions measured at 217.0005 and 217.0458 nm, i.e. k = (slope217.0005 nm/slope217.0458 nm). For wavelength integrated absorbance of 3 pixels, sample aspiration rate of 5.0 ml min-1, analytical curves in the 0.1 - 1.0 mg L-1 Pb range with linearity better than 0.9990 were consistently obtained. Calibration curves for P at 217.0005 and 217.0458 nm with linearity better than 0.998 were obtained. Relative standard deviations (RSD) of measurements (n = 12) in the range of 1.4 - 4.3% and 2.0 - 6.0% without and with mathematical equation correction approach were obtained respectively. The limit of detection calculated to analytical line at 217.0005 nm was 10 µg L-1 Pb. Recoveries for Pb spikes were in the 97.5 - 100% and 105 - 230% intervals with and without mathematical equation correction approach, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal and air conditions inside animal facilities change during the day due to the influence of the external environment. For statistical and geostatistical analyses to be representative, a large number of points spatially distributed in the facility area must be monitored. This work suggests that the time variation of environmental variables of interest for animal production, monitored within animal facility, can be modeled accurately from discrete-time records. The aim of this study was to develop a numerical method to correct the temporal variations of these environmental variables, transforming the data so that such observations are independent of the time spent during the measurement. The proposed method approached values recorded with time delays to those expected at the exact moment of interest, if the data were measured simultaneously at the moment at all points distributed spatially. The correction model for numerical environmental variables was validated for environmental air temperature parameter, and the values corrected by the method did not differ by Tukey's test at 5% significance of real values recorded by data loggers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traumatic diaphragmatic hernia is defined as a laceration of the diaphragm with an abdominal viscera herniation into the thorax. It is usually asymptomatic, with the exception of the cases with obstruction, strangulation, necrosis or perforation of the herniaded viscera. It is classified as acute, latent or chronic, in accordance with the evolutive period. At the latent phase, symptoms are indefinite and the radiological signals, which are suggestive of thoracic affections, are frequent and can induce a diagnosis error, leading to inadequate treatment.This article presents a case of chronic traumatic diaphragmatic hernia which was complicated by a gastricpleuralcutaneous fistula, due to an inadequate thoracic drainage. Considering that this is a chronic affection with an unquestionable surgical indication, due to the complications risk, it is essential to have a detailed diagnostic investigation, which aims at both avoiding an intempestive or inadequate therapeutics behaviour and reducing the affection morbimortality. Recently, the videolaparoscopic approach has proved to be more precise when compared to the other diagnostic methods, by direct visualization of the diaphragmatic laceration, allowing its correction by an immediate suture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACTObjective:to assess the impact of the shift inlet trauma patients, who underwent surgery, in-hospital mortality.Methods:a retrospective observational cohort study from November 2011 to March 2012, with data collected through electronic medical records. The following variables were statistically analyzed: age, gender, city of origin, marital status, admission to the risk classification (based on the Manchester Protocol), degree of contamination, time / admission round, admission day and hospital outcome.Results:during the study period, 563 patients injured victims underwent surgery, with a mean age of 35.5 years (± 20.7), 422 (75%) were male, with 276 (49.9%) received in the night shift and 205 (36.4%) on weekends. Patients admitted at night and on weekends had higher mortality [19 (6.9%) vs. 6 (2.2%), p=0.014, and 11 (5.4%) vs. 14 (3.9%), p=0.014, respectively]. In the multivariate analysis, independent predictors of mortality were the night admission (OR 3.15), the red risk classification (OR 4.87), and age (OR 1.17).Conclusion:the admission of night shift and weekend patients was associated with more severe and presented higher mortality rate. Admission to the night shift was an independent factor of surgical mortality in trauma patients, along with the red risk classification and age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyze the performance of two surgical meshes of different compositions during the defect healing process of the abdominal wall of rats. Methods: thirty-three adult Wistar rats were anesthetized and subjected to removal of an area of 1.5 cm x 2 cm of the anterior abdominal wall, except for the skin; 17 animals had the defect corrected by edge-to-edge surgical suture of a mesh made of polypropylene + poliglecaprone (Group U - UltraproTM); 16 animals had the defect corrected with a surgical mesh made of polypropylene + polidioxanone + cellulose (Group P - ProceedTM). Each group was divided into two subgroups, according to the euthanasia moment (seven days or 28 days after the operation). Parameters analyzed were macroscopic (adherence), microscopic (quantification of mature and immature collagen) and tensiometric (maximum tension and maximum rupture strength). Results : there was an increase in collagen type I in the ProceedTM group from seven to 28 days, p = 0.047. Also, there was an increase in the rupture tension on both groups when comparing the two periods. There was a lower rupture tension and tissue deformity with ProceedTM mesh in seven days, becoming equal at day 28. Conclusion : the meshes retain similarities in the final result and more studies with larger numbers of animals must be carried for better assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To obtain the desirable accuracy of a robot, there are two techniques available. The first option would be to make the robot match the nominal mathematic model. In other words, the manufacturing and assembling tolerances of every part would be extremely tight so that all of the various parameters would match the “design” or “nominal” values as closely as possible. This method can satisfy most of the accuracy requirements, but the cost would increase dramatically as the accuracy requirement increases. Alternatively, a more cost-effective solution is to build a manipulator with relaxed manufacturing and assembling tolerances. By modifying the mathematical model in the controller, the actual errors of the robot can be compensated. This is the essence of robot calibration. Simply put, robot calibration is the process of defining an appropriate error model and then identifying the various parameter errors that make the error model match the robot as closely as possible. This work focuses on kinematic calibration of a 10 degree-of-freedom (DOF) redundant serial-parallel hybrid robot. The robot consists of a 4-DOF serial mechanism and a 6-DOF hexapod parallel manipulator. The redundant 4-DOF serial structure is used to enlarge workspace and the 6-DOF hexapod manipulator is used to provide high load capabilities and stiffness for the whole structure. The main objective of the study is to develop a suitable calibration method to improve the accuracy of the redundant serial-parallel hybrid robot. To this end, a Denavit–Hartenberg (DH) hybrid error model and a Product-of-Exponential (POE) error model are developed for error modeling of the proposed robot. Furthermore, two kinds of global optimization methods, i.e. the differential-evolution (DE) algorithm and the Markov Chain Monte Carlo (MCMC) algorithm, are employed to identify the parameter errors of the derived error model. A measurement method based on a 3-2-1 wire-based pose estimation system is proposed and implemented in a Solidworks environment to simulate the real experimental validations. Numerical simulations and Solidworks prototype-model validations are carried out on the hybrid robot to verify the effectiveness, accuracy and robustness of the calibration algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To evaluate the precision of both two- and three-dimensional ultrasonography in determining vertebral lesion level (the first open vertebra) in patients with spina bifida. Methods This was a prospective longitudinal study comprising of fetuses with open spina bifida who were treated in the fetal medicine division of the department of obstetrics of Hospital das Clínicas of the Universidade de São Paulo between 2004 and 2013. Vertebral lesion level was established by using both two- and three-dimensional ultrasonography in 50 fetuses (two examiners in each method). The lesion level in the neonatal period was established by radiological assessment of the spine. All pregnancies were followed in our hospital prenatally, and delivery was scheduled to allow immediate postnatal surgical correction. Results Two-dimensional sonography precisely estimated the spina bifida level in 53% of the cases. The estimate error was within one vertebra in 80% of the cases, in up to two vertebrae in 89%, and in up to three vertebrae in 100%, showing a good interobserver agreement. Three-dimensional ultrasonography precisely estimated the lesion level in 50% of the cases. The estimate error was within one vertebra in 82% of the cases, in up to two vertebrae in 90%, and in up to three vertebrae in 100%, also showing good interobserver agreement. Whenever an estimate error was observed, both two- and three-dimensional ultrasonography scans tended to underestimate the true lesion level (55.3% and 62% of the cases, respectively). Conclusions No relevant difference in diagnostic performance was observed between the two- and three-dimensional ultrasonography. The use of three-dimensional ultrasonography showed no additional benefit in diagnosing the lesion level in the fetuses with spina bifida. Errors in both methods showed a tendency to underestimate lesion level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the surface hardening of steels via experimental tests using a multi-kilowatt fiber laser as the laser source. The influence of laser power and laser power density on the hardening effect was investigated. The microhardness analysis of various laser hardened steels was done. A thermodynamic model was developed to evaluate the thermal process of the surface treatment of a wide thin steel plate with a Gaussian laser beam. The effect of laser linear oscillation hardening (LLOS) of steel was examined. An as-rolled ferritic-pearlitic steel and a tempered martensitic steel with 0.37 wt% C content were hardened under various laser power levels and laser power densities. The optimum power density that produced the maximum hardness was found to be dependent on the laser power. The effect of laser power density on the produced hardness was revealed. The surface hardness, hardened depth and required laser power density were compared between the samples. Fiber laser was briefly compared with high power diode laser in hardening medium-carbon steel. Microhardness (HV0.01) test was done on seven different laser hardened steels, including rolled steel, quenched and tempered steel, soft annealed alloyed steel and conventionally through-hardened steel consisting of different carbon and alloy contents. The surface hardness and hardened depth were compared among the samples. The effect of grain size on surface hardness of ferritic-pearlitic steel and pearlitic-cementite steel was evaluated. In-grain indentation was done to measure the hardness of pearlitic and cementite structures. The macrohardness of the base material was found to be related to the microhardness of the softer phase structure. The measured microhardness values were compared with the conventional macrohardness (HV5) results. A thermodynamic model was developed to calculate the temperature cycle, Ac1 and Ac3 boundaries, homogenization time and cooling rate. The equations were numerically solved with an error of less than 10-8. The temperature distributions for various thicknesses were compared under different laser traverse speed. The lag of the was verified by experiments done on six different steels. The calculated thermal cycle and hardened depth were compared with measured data. Correction coefficients were applied to the model for AISI 4340 steel. AISI 4340 steel was hardened by laser linear oscillation hardening (LLOS). Equations were derived to calculate the overlapped width of adjacent tracks and the number of overlapped scans in the center of the scanned track. The effect of oscillation frequency on the hardened depth was investigated by microscopic evaluation and hardness measurement. The homogeneity of hardness and hardened depth with different processing parameters were investigated. The hardness profiles were compared with the results obtained with conventional single-track hardening. LLOS was proved to be well suitable for surface hardening in a relatively large rectangular area with considerable depth of hardening. Compared with conventional single-track scanning, LLOS produced notably smaller hardened depths while at 40 and 100 Hz LLOS resulted in higher hardness within a depth of about 0.6 mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä tutkitaan tiedonsiirtoa eri modulaatioilla, bittinopeuksilla ja amplitudin voimakkuuksilla ja tuloksia tarkastellaan Bit Error Ration avulla. Signaaleja siirrettiiin myös koodattuna ja vertailtiin koodauksen etuja ja haittoja verrattuna koodaamattomaan tietoon. Datavirta kulkee AXMK-kaapelissa, joko tasasähkön mukana, tai maadoituskaapelissa. Tuloksissa havaittiin, että suurempi bittinopeus ei kasvattanut häviöiden määrää. Koodauksen käyttö toisaalta vähenti bittivirheiden määrää.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article deals with a contour error controller (CEC) applied in a high speed biaxial table. It works simultaneously with the table axes controllers, helping them. In the early stages of the investigation, it was observed that its main problem is imprecision when tracking non-linear contours at high speeds. The objectives of this work are to show that this problem is caused by the lack of exactness of the contour error mathematical model and to propose modifications in it. An additional term is included, resulting in a more accurate value of the contour error, enabling the use of this type of motion controller at higher feedrate. The response results from simulated and experimental tests are compared with those of common PID and non-corrected CEC in order to analyse the effectiveness of this controller over the system. The main conclusions are that the proposed contour error mathematical model is simple, accurate, almost insensible to the feedrate and that a 20:1 reduction of the integral absolute contour error is possible.