1000 resultados para Electrical profiling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The working condition and atmosphere in a wooden fishing vessel are generally most injurious to the electrical systems. Therefore great care has to be taken in designing electrical systems for small c1afts. This paper deals with the difficult operating conditions and standardisation of electrical systems as applicable to small fishing vessels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was carried out for recognized ichthyophon and investigation of feeding and effects of water temperature, salinity and electrical conductivity on the population dynamic of Barbus grypus in the Dalaki and Helle river. In the study period, 2949 Barbus grypus was cached. The most of total length frequency was 200 to 300 mm and 2 to 3 years old. The oldest fish was8 years old with 756 mm total length. Fecundity was 950 upto 57400 oocyt per fish. Station no. 6 and 7 showed more temperature, fecundity and GSI than other stations. Females adulated before then males. Multiple stepwise regression of fecundity and RE (reproduction effort) showed significant correlation. Fishes of the upper parts of stream was more L than down stream stations. Condition factor of males was more than female, and for down stream stations was better than the other stations. Barbus grypus is omnivorous. Ichthyophon of Dalaki river include 4 family and 9 species that Capoeta capoeta intermadia was more than others species, but in the Helle river was 5 family and 9 species, that Liza abu zarudni was more than others.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present experimental results describing enhanced readout of the vibratory response of a doubly clamped zinc oxide (ZnO) nanowire employing a purely electrical actuation and detection scheme. The measured response suggests that the piezoelectric and semiconducting properties of ZnO effectively enhance the motional current for electromechanical transduction. For a doubly clamped ZnO nanowire resonator with radius ~10 nm and length ~1.91 µm, a resonant frequency around 21.4 MHz is observed with a quality factor (Q) of ~358 in vacuum. A comparison with the Q obtained in air (~242) shows that these nano-scale devices may be operated in fluid as viscous damping is less significant at these length scales. Additionally, the suspended nanowire bridges show field effect transistor (FET) characteristics when the underlying silicon substrate is used as a gate electrode or using a lithographically patterned in-plane gate electrode. Moreover, the Young's modulus of ZnO nanowires is extracted from a static bending test performed on a nanowire cantilever using an AFM and the value is compared to that obtained from resonant frequency measurements of electrically addressed clamped–clamped beam nanowire resonators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On-body sensor systems for sport are challenging since the sensors must be lightweight and small to avoid discomfort, and yet robust and highly accurate to withstand and capture the fast movements associated with sport. In this work, we detail our experience of building such an on-body system for track athletes. The paper describes the design, implementation and deployment of an on-body sensor system for sprint training sessions. We autonomously profile sprints to derive quantitative metrics to improve training sessions. Inexpensive Force Sensitive Resistors (FSRs) are used to capture foot events that are subsequently analysed and presented back to the coach. We show how to identify periods of sprinting from the FSR data and how to compute metrics such as ground contact time. We evaluate our system using force plates and show that millisecond-level accuracy is achievable when estimating contact times. © 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A superconducting fault current limiter (SFCL) in series with a downstream circuit breaker could provide a viable solution to controlling fault current levels in electrical distribution networks. In order to integrate the SFCL into power grids, we need a way to conveniently predict the performance of the SFCL in a given scenario. In this paper, short circuit analysis based on the electromagnetic transient program was used to investigate the operational behavior of the SFCL installed in an electrical distribution grid. System studies show that the SFCL can not only limit the fault current to an acceptable value, but also mitigate the voltage sag. The transient recovery voltage (TRV) could be remarkably damped and improved by the presence of the SFCL after the circuit breaker is opened to clear the fault. © 2007 British Crown Copyright.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the electrical properties of Silicon-on-Insulator photonic crystals as a function of doping level and air filling factor. A very interesting trade-off between conductivity and optical losses in L3 cavities is also found. © 2011 IEEE.