959 resultados para Diagnostic Test Accuracy
Resumo:
BACKGROUND: Ultrasonography (US), Computed Tomography (CT), and Magnetic Resonance imaging (MR) were compared for the staging of renal tumors. The differences between these imaging techniques were also studied for their ability to detect adenopathies, vascular invasion, distant intra-abdominal metastases, and particularly adjacent organ invasion. METHODS: Thirty-one patients with solid or complex renal masses were prospectively studied using US, CT, and MR. Differences between the results obtained were studied using the COCHRAN G test and the McNEMAR test. The sensitivity and specificity of each diagnostic technique were compared against a gold standard of the surgical and histopathological findings. RESULTS: The following sensitivities were obtained: For the detection of adenopathy, US 63.6%, CT and MR 90.9%. For vascular invasion, US 42.8%, CT and MR 85.7%. For the adjacent organ invasion, US 28.5%, CT 85.7%, and MR 71.4%. Some of the criteria that suggest invasion of adjacent structures include: the envelopment of the adjacent structures by the tumor, tumor extension into the adjacent structures with an irregular appearance, and alterations in shape, size, and density of adjacent structures. Loss of fat planes between the tumor and adjacent structures is not a sign of tumor invasion. CONCLUSIONS: Significant differences were found in the detection capacity of US in relation to CT and MR, which were similar. All three techniques were highly sensitive and specific only in the detection of distant abdominal metastases. In addition to the accuracy of these diagnostic modalities for the detection and staging of tumors, invasiveness, risks and cost should be considered in relation to relative costs and benefits.
Resumo:
Indirect ELISA and IFAT have been reported to be more sensitive and specific than agglutination tests. However, MAT is cheaper, easier than the others and does not need special equipment. The purpose of this study was to compare an enzyme linked immunosorbent assay using crude rhoptries of Toxoplasma gondii as coating wells (r-ELISA) with indirect fluorescence antibody test (IFAT) and modified agglutination test (MAT) to detect anti-T. gondii antibodies in sera of experimentally infected pigs. Ten mixed breed pigs between 6.5 and 7.5 weeks old were used. All pigs were negative for the presence of T. gondii antibodies by IFAT (titre < 16), r-ELISA (OD < 0.295) and MAT (titre < 16). Animals received 7 × 107 viable tachyzoites of the RH strain by intramuscular (IM) route at day 0. Serum samples were collected at days -6, 0, 7, 14, 21, 28, 35, 42, 50, and 57. IFAT detected anti-T. gondii antibodies earlier than r-ELISA and MAT. The average of antibody levels was higher at day 35 in IFAT (Log10 = 2.9) and in MAT (Log10 = 3.5), and at day 42 in r-ELISA (OD = 0.797). The antibody levels remained high through the 57th day after inoculation in MAT, and there was a decrease tendency in r-ELISA and IFAT. IFAT was used as gold standard and r-ELISA demonstrated a higher prevalence (73.3%), sensitivity (94.3%), negative predictive value (83.3%), and accuracy (95.6%) than MAT. Kappa agreements among tests were calculated, and the best results were shown by r-ELISA × IFAT (κ = 0.88, p < 0.001). Cross-reaction with Sarcocystis miescheriana was investigated in r-ELISA and OD mean was 0.163 ± 0.035 (n = 65). Additionally, none of the animals inoculated with Sarcocystis reacted positively in r-ELISA. Our results indicate that r-ELISA could be a good method for serological detection of T. gondii infection in pigs. © 2005 Elsevier Inc. All rights reserved.
Resumo:
This study was performed to standardize parasite egg counting in feces of sheep by TF-Test, in addition to compare this test to the Gordon & Whitlock technique (G&W). Twenty-four lambs were artificially infected with Haemonchus contortus throughout 12 weeks. At the end of this time, faecal samples were taken and animals were slaughtered for worm identification and counting. G&W and TF-Test methods were carried out on each fecal sample. Both tests showed Haemonchus eggs in 95.8% of the samples (P>0.05). The correlation coefficients (r) between fecal egg counts (FEC) using G&W × Total Worm Count (TWC) were r=0.52 (not transformed data) and r=0.85 (transformed data); between FEC by TF-Test × TWC were r=0.51 (not transformed data) and r=0.87 (transformed data). Other 100 fecal samples were taken from naturally infected sheep. In these animals, the G&W and TF-Test methods showed 85% and 86% of fecal samples positive for Strongylidea eggs, respectively (P>0.05). Also in those animals, Eimeria oocysts were found in 33% of fecal samples by TF-Test, whereas in the G&W only 12% were positive (P<0.001). For Strongyloides spp., TF-Test showed 15% of positive fecal samples, whereas G&W showed 5% (P<0.05). In conclusion, both methods were efficient to diagnose gastrointestinal nematodes and TF-Test was superior to diagnose oocysts of Eimeria spp. and eggs of Strongyloides spp; conversely, Strongylidea eggs counting using TF-Test was underestimated.
Resumo:
Objective: To evaluate data from patients with normal oral glucose tolerance test (OGTT) results and a normal or impaired glycemic profile (GP) to determine whether lower cutoff values for the OGTT and GP (alone or combined) could identify pregnant women at risk for excessive fetal growth. Methods: We classified 701 pregnant women with positive screening for gestational diabetes mellitus (GDM) into 2 categories - (1) normal 100-g OGTT and normal GP and (2) normal 100-g OGTT and impaired GP - to evaluate the influence of lower cutoff points in a 100-g OGTT and GP (alone or in combination) for identification of pregnant women at excessive fetal growth risk. The OGTT is considered impaired if 2 or more values are above the normal range, and the GP is impaired if the fasting glucose level or at least 1 postprandial glucose value is above the normal range. To establish the criteria for the OGTT (for fasting and 1, 2, and 3 hours after an oral glucose load, respectively), we considered the mean (75 mg/dL, 120 mg/dL, 113 mg/dL, and 97 mg/dL), mean plus 1 SD (85 mg/dL, 151 mg/dL, 133 mg/dL, and 118 mg/dL), and mean plus 2 SD (95 mg/dL, 182 mg/dL, 153 mg/dL, and 139 mg/dL); and for the GP, we considered the mean and mean plus 1 SD (78 mg/dL and 92 mg/dL for fasting glucose levels and 90 mg/dL and 130 mg/dL for 1- or 2-hour postprandial glucose levels, respectively). Results: Subsequently, the women were reclassified according to the new cutoff points for both tests (OGTT and GP). Consideration of values, in isolation or combination, yielded 6 new diagnostic criteria. Excessive fetal growth was the response variable for analysis of the new cutoff points. Odds ratios and their respective confidence intervals were estimated, as were the sensitivity and specificity related to diagnosis of excessive fetal growth for each criterion. The new cutoff points for the tests, when used independently rather than collectively, did not help to predict excessive fetal growth in the presence of mild hyperglycemia. Conclusion: Decreasing the cutoff point for the 100-g OGTT (for fasting and 1, 2, and 3 hours) to the mean (75 mg/dL, 120 mg/dL, 113 mg/dL, and 97 mg/dL) in association with the GP (mean or mean plus 1 SD-78 mg/dL and 92 mg/dL for the fasting state and 90 mg/dL and 130 mg/dL for 1- or 2-hour postprandial values-increased the sensitivity and specificity, and both criteria had statistically significant predictive power for detection of excessive fetal growth. © 2008 AACE.
Resumo:
Purpose: This study evaluated the influence of surface abrasion of transfer copings to obtain a precise master cast for a partially edentulous restoration with different inclinations. Materials and Methods: Replicas (N = 30) of a metal matrix (control group) containing two implants at 90° and 65° in relation to the benchtop were obtained using a polyether impression material and three impression techniques: square impression copings splint with dental floss and autopolymerizing acrylic resin (TRS), square impression copings abraded with aluminum oxide (TA), and square impression copings abraded with aluminum oxide and adhesive-coated (TAA). The replicas obtained in type V stone were digitalized, and the images were exported to AutoCAD software to perform the readings of possible degree alterations in implant inclinations. The results were submitted to analysis of variance (ANOVA) and Tukey test (α < 0.05). Results: Comparing the techniques with regard to the 90° implant inclination, no statistical difference was observed between the three techniques and the control group. Analyzing the three techniques with regard to the 65° implant inclination, no significant difference was seen between technique TA and the control group. Conclusions: Technique TA presented more accurate master casts than TRS and TAA techniques. The angulated implant (65°) tended to generate more imprecise master casts than implants perpendicular to the surface. © 2008 by The American College of Prosthodontists.
Resumo:
The aim of this study was to evaluate the dimensional changes of denture bases made from different resins after different storage periods. For this purpose, 25 sets of plaster models/resin bases were prepared using 4 acrylic resins submitted to two types of polymerization: 1- QC-20 submitted to polymerization by microwave energy; 2- QC-20 submitted to polymerization by water hot bath; 3- Vipi Cril submitted to polymerization by water hot bath; 4- Vipi Wave submitted to polymerization by microwave energy; and 5- Onda Cryl submitted to polymerization by microwave energy. After polymerization, the specimens were sectioned for accuracy readings using a comparison microscope. Readings were taken at 3 points: the crests of the right (A) and left (B) ridges, and the median region of the palate, in 4 different periods. The data obtained were submitted to two-way ANOVA and Tukey's test at 5% significance level. The greatest distortions were found in the posterior palatal region of the base (M), with statistically significant difference (p<0.05) for the studied resins. All acrylic resins presented dimensional changes and the storage period influenced these alterations.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this study was to evaluate whether digitized images obtained from occlusal radiographs taken with low or over dose of radiation could be improved with the aid of computer software for digital treatment. Thirteen occlusal radiographs of a dry skull were taken employing 13 different exposure times. The radiographs were digitized and then manipulated with the program for image editing. 143 evaluations were performed by specialists in dental radiology who classified radiographs as appropriate or not appropriate for interpretation. Test Z was used for statistical analysis of the data and the results showed that it is possible to manipulate digitized radiographic images taken with 75% of the ideal exposure time and to make them suitable for interpretation and diagnosis. Conversely, it was concluded that the over exposed images, 57.50% above the standard exposure time, were inadequate.
Resumo:
The influence of soil drill rod length on the N value in the SPT-T test has been studied extensively by Mello (1971), Schmertmann & Palacios (1979), Odebrecht et al. (2002) and Cavalcante (2002). This paper presents an analysis of the Standard Penetration Test supplemented with torque measurement (SPT-T). A theoretical study of the resistance of the rod material to torsion and bending indicated that the shear stress caused by the rod self-weight represents less than 1% of that caused by the torsional moment. An experimental study with electric torquemeters attached to a horizontal rod system, as well as two field tests in the vertical direction, were also carried out to compare and substantiate the results. The purpose of these tests was to analyze changes along the length of the rod in response to successive increments at 1-meter intervals. Torque measurements were taken at each increment of the length to ascertain the accuracy of the theoretical data. The difference between the applied torque and the measured torque at the end of rod system was lower than the minimum scale of mechanical torquemeters used in practice.
Resumo:
This study evaluated the influence of tooth embedding media on the accuracy ofan electronic apex locator. The root canal length of 20 human mandibular canines was measured by inserting a 15 K-file into the root canal up to the apical foramen. The distance was measured with a digital caliper. The embedding media evaluated were alginate, saline, floral foam or gauze soaked in saline. Electronic root canal length measurement was performed with Root ZX II. Data were analysed using ANOVA for repeated measurements and Tukey test, at a significance level of 5%. There was no difference between the actual root canal length measurement and the electronic reading recorded with alginate medium. The readings obtained with the other media differed from the actual root canal length measurements. Alginate provided greater accuracy in electronic root canal length determination by Root ZX II than saline, floral foam and gauze.
Resumo:
Objectives: The stair-climbing test as measured in meters or number of steps has been proposed to predict the risk of postoperative complications. The study objective was to determine whether the stair-climbing time can predict the risk of postoperative complications. Methods: Patients aged more than 18 years with a recommendation of thoracotomy for lung resection were included in the study. Spirometry was performed according to the criteria by the American Thoracic Society. The stair-climbing test was performed on shaded stairs with a total of 12.16 m in height, and the stair-climbing time in seconds elapsed during the climb of the total height was measured. The accuracy test was applied to obtain stair-climbing time predictive values, and the receiver operating characteristic curve was calculated. Variables were tested for association with postoperative cardiopulmonary complications using the Student t test for independent populations, the Mann-Whitney test, and the chi-square or Fisher exact test. Logistic regression analysis was performed. Results: Ninety-eight patients were evaluated. Of these, 27 showed postoperative complications. Differences were found between the groups for age and attributes obtained from the stair-climbing test. The cutoff point for stair-climbing time obtained from the receiver operating characteristic curve was 37.5 seconds. No differences were found between the groups for forced expiratory volume in 1 second. In the logistic regression, stair-climbing time was the only variable associated with postoperative complications, suggesting that the risk of postoperative complications increases with increased stair-climbing time. Conclusions: The only variable showing association with complications, according to multivariate analysis, was stair-climbing time. © 2013 by The American Association for Thoracic Surgery.
Resumo:
Background: This study aimed to establish reference values for selected ophthalmic diagnostic tests in healthy neotropical primates from Salvador, Brazil. Methods: A total of 73 intact adults, including Callithrix jacchus (n = 31), Callithrix penicillata (n = 8), Cebus sp. (n = 22), and Cebus xanthosternos (n = 9) were used to evaluate the normal conjunctival bacterial flora. Cebus xanthosternos (n = 12) were used to evaluate tear production with Schirmer's tear test (STT), intraocular pressure (IOP), and conjunctival cytology. Results: For all animals evaluated, Gram-positive bacteria were predominant. Results of the diagnostic tests in Cebus xanthosternos were as follows: STT: 14.92 ± 5.46 mm/minutes, IOP: 19.62 ± 4.57 mmHg, and conjunctival cytology revealed intermediate squamous epithelial cells in great quantities. Conclusions: These ophthalmic reference values will be particularly useful to diagnose discrete or unusual pathological changes in the neotropical primates eye. © 2013 John Wiley & Sons A/S.
Resumo:
Objectives: This in vitro study compared the dimensional accuracy of stone index (I) and three impression techniques: tapered impression copings (T), squared impression copings (S) and modified squared impression copings (MS) for implant-supported prostheses. Methods: A master cast, with four parallel implant abutment analogs and a passive framework, were fabricated. Vinyl polysiloxane impression material was used for all impressions with two metal stock trays (open and closed tray). Four groups (I, T, S and MS) were tested (n = 5). A metallic framework was seated on each of the casts, one abutment screw was tightened, and the gap between the analog of implant and the framework was measured with a stereomicroscope. The groups' measurements (80 gap values) were analyzed using software (LeicaQWin - Leica Imaging Systems Ltd.) that received the images of a video camera coupled to a Leica stereomicroscope at 100× magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, 0.05. Results: The mean values of abutment/framework interface gaps were: Master Cast = 32 μm (SD 2); Group I = 45 μm (SD 3); Group T = 78 μm (SD 25); Group S = 134 μm (SD 30); Group MS = 143 μm (SD 27). No significant difference was detected among Index and Master Cast (P = .05). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast is possible using tapered impression copings techniques and stone index. © 2013 Japan Prosthodontic Society.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)