995 resultados para DISSOLVED COPPER


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cu samples were subjected to high-pressure torsion (HPT) with up to 6 turns at room temperature (RT) and liquid nitrogen temperature (LNT), respectively. The effects of temperature on grain refinement and microhardness variation were investigated. For the samples after HPT processing at RT, the grain size reduced from 43 mu m to 265 nm, and the Vickers microhardness increased from HV52 to HV140. However, for the samples after HPT processing at LNT, the value of microhardness reached its maximum of HV150 near the center of the sample and it decreased to HV80 at the periphery region. Microstructure observations revealed that HPT straining at LNT induced lamellar structures with thickness less than 100 nm appearing near the central region of the sample, but further deformation induced an inhomogeneous distribution of grain sizes, with submicrometer-sized grains embedded inside micrometer-sized grains. The submicrometer-sized grains with high dislocation density indicated their nonequilibrium nature. On the contrary, the micrometer-sized grains were nearly free of dislocation, without obvious deformation trace remaining in them. These images demonstrated that the appearance of micrometer-sized grains is the result of abnormal grain growth of the deformed fine grains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A capillary electrophoresis microchip coupled with a confocal laser-induced fluorescence (LIF) detector was successfully constructed for the analysis of trace amounts of heavy metals in environmental sources. A new fluorescence dye, RBPhOH, synthesized from rhodamine B, was utilized in a glass microchip to selectively determine copper with high sensitivity. A series of factors including running buffer concentration, detection voltage, and sample loading time were optimized for maximum LIF detector response and, hence, method sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new copper-(Schiff-base) complex, derived from (S)-2-amino-1,1-di(3,5-di-t-butylphenyl)propanol, 2-hydroxy-5-nitrobenzaldehyde and copper acetate monohydrate, was used as an efficient catalyst for the cyclopropanation of styrene with diazoacetates, affording ees of up to 98%. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Geochemical processes in estuarine and coastal waters often occur on temporally and spatially small scales, resulting in variability of metal speciation and dissolved concentrations. Thus, surveys, which are aimed to improve our understanding of metal behaviour in such systems, benefit from high-resolution, interactive sampling campaigns. The present paper discusses a high-resolution approach to coastal monitoring, with the application of an automated voltammetric metal analyser for on-line measurements of dissolved trace metals in the Gulf of Cadiz, south-west Spain. This coastal sea receives metal-rich inputs from a metalliferous mining area, mainly via the Huelva estuary. On-line measurements of dissolved Cu, Zn, Ni and Co were carried out on-board ship during an eight-day sampling campaign in the study area in June 1997. A pumping system operated continuously underway and provided sampled water from a depth of ca. 4 m. Total dissolved metal concentrations measured on-line in the Gulf of Cadiz ranged between <5 nM Cu (<3 nM Ni) ca. 50 km off-shore and 60–90 nM Cu (5–13 nM Ni) in the vicinity of the Huelva estuary. The survey revealed steep gradients and strong tidal variability in the dissolved metal plume extending from the Huelva estuary into the Gulf of Cadiz. Further on-line measurements were carried out with the automatic metal monitor from the bank of the Odiel estuary over a full tidal cycle, at dissolved metal concentrations in the μM range. The application confirmed the suitability of the automated metal monitor for coastal sampling, and demonstrated its adaptability to a wide range of environmental conditions in the dynamic waters of estuaries and coastal seas. The near-real time acquisition of dissolved metal concentrations at high resolution enabled an interactive sampling campaign and therefore the close investigation of tidal variability in the development of the Huelva estuary metal plume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validation of a fully automated dissolved Ni monitor for in situ estuarine studies is presented, based on adsorptive cathodic stripping voltammetry (AdCSV). Dissolved Ni concentrations were determined following on-line filtration and UV digestion, and addition of an AdCSV ligand (dimethyl glyoxime) and pH buffer (N-2-hydroxyethylpiperazine-N′-2-ethanesulphonic acid). The technique is capable of up to six fully quantified Ni measurements per hour. The automated in situ methodology was applied successfully during two surveys on the Tamar estuary (south west Britain). The strongly varying sample matrix encountered in the estuarine system did not present analytical interferences, and each sample was quantified using internal standard additions. Up to 37 Ni measurements were performed during each survey, which involved 13 h of continuous sampling and analysis. The high resolution data from the winter and summer tidal cycle studies allowed a thorough interpretation of the biogeochemical processes in the studied estuarine system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have found that a commonly used complexation and solvent extraction technique (using mixed dithiocarbamates/Freon/HNO3) does not always extract Cd, Co, Cu and Ni from estuarine samples with the same efficiency as from Milli-Q water. For samples collected from the Derwent Estuary (Australia), the reduced extraction efficiency only occurred for unfiltered samples, but low extraction efficiencies were also observed for a (filtered) riverine certified reference material (SLRS-3) suggesting that the effect may be widespread. We have not been able to identify the reason for the low extraction efficiency and, although it is strongly correlated with the presence of high concentrations of suspended solids, dissolved organic matter and particulate iron, we have no experimental evidence to directly link any of these parameters to the effect. It is possible that similar effects may occur in other techniques which rely on a preconcentration step prior to analysis and that some literature values of heavy metals in estuarine waters may be low. We propose a modification of the standard complexation/solvent extraction method which overcomes these difficulties without adding significantly to the time taken for analyses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temporal trends in total ozone for the St. Lawrence estuary were estimated from ground-based measurements at the NOAA/CMDL station in Caribou, Maine. Linear regression analysis showed that from 1979 to 1999 total ozone has decreased by about 3.3% per decade on an annual basis and ≤6.2% per decade on a monthly basis relative to unperturbed (pre-CFC) levels. The influence of increased ultraviolet-B (280–320 nm) radiation associated with ozone depletion on water column photochemical processes was evaluated by modeling the photobleaching of chromophoric dissolved organic material (CDOM). Linear regression analysis showed small (<0.5% per decade), but statistically significant upward trends in maximum noontime photobleaching rates. Most notably, positive trends in relative rates for May, June, and July, when maximum absolute rates are expected, were predicted. A global model based on TOMS ozone data revealed increases in photobleaching of ≤3% per decade at high latitudes in the Southern Hemisphere. Radiation amplification factors for increases in photochemically weighted UV (280–400 nm) in response to ozone depletion were estimated at 0.1 and 0.08 for photobleaching of CDOM absorbance at 300 and 350 nm, respectively. Application of the laboratory-based model to conditions that more closely resembled those in situ were variable with both overestimation and underestimation of measured rates. The differences between modeled rates and observed rates under quasi-natural conditions were as large or larger than the predicted increases due to ozone depletion. These comparisons suggest that biological activity and mixing play an important, but as yet ill-defined, role in modifying photochemical processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Levels of the heavy metals Cd, Cr, Cu, Pb and Zn, in both the dissolved and particulate phase, were determined in two sampling campaigns in August 1978 and August 1984 in the Dutch Rhine-Meuse (Maas) Delta. Besides the heavy metal concentrations, other important parameters were determined, such as the concentrations of seston, chlorophyll and nutrients. The concentrations of dissolved Cd and of Cd, Pb and Cu in particulate matter were much higher in 1978 than in 1984, especially for Cd. This may be due to the strict regulations implemented in Germany to reduce the pollution of natural waters by heavy metals. The correlation between the high Cd content and the chlorophyll content is explained by the binding of Cd to living and dead organisms. The distribution of the metals between the dissolved and the particulate phase, indicated by the distribution quotient Kd , increases from low values of Kd for Cu and Zn, to higher values for Cd and Cr, and the highest values for Pb. The differences are explained by various binding forms of each of these metals in natural waters