913 resultados para Corneal biomechanics


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Convective transport, both pure and combined with diffusion and reaction, can be observed in a wide range of physical and industrial applications, such as heat and mass transfer, crystal growth or biomechanics. The numerical approximation of this class of problemscan present substantial difficulties clue to regions of high gradients (steep fronts) of the solution, where generation of spurious oscillations or smearing should be precluded. This work is devoted to the development of an efficient numerical technique to deal with pure linear convection and convection-dominated problems in the frame-work of convection-diffusion-reaction systems. The particle transport method, developed in this study, is based on using rneshless numerical particles which carry out the solution along the characteristics defining the convective transport. The resolution of steep fronts of the solution is controlled by a special spacial adaptivity procedure. The serni-Lagrangian particle transport method uses an Eulerian fixed grid to represent the solution. In the case of convection-diffusion-reaction problems, the method is combined with diffusion and reaction solvers within an operator splitting approach. To transfer the solution from the particle set onto the grid, a fast monotone projection technique is designed. Our numerical results confirm that the method has a spacial accuracy of the second order and can be faster than typical grid-based methods of the same order; for pure linear convection problems the method demonstrates optimal linear complexity. The method works on structured and unstructured meshes, demonstrating a high-resolution property in the regions of steep fronts of the solution. Moreover, the particle transport method can be successfully used for the numerical simulation of the real-life problems in, for example, chemical engineering.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Hallux valgus is one of the most common forefoot problems in females. Studies have looked at gait alterations due to hallux valgus deformity, assessing temporal, kinematic or plantar pressure parameters individually. The present study, however, aims to assess all listed parameters at once and to isolate the most clinically relevant gait parameters for moderate to severe hallux valgus deformity with the intent of improving post-operative patient prognosis and rehabilitation. METHODS: The study included 26 feet with moderate to severe hallux valgus deformity and 30 feet with no sign of hallux valgus in female participants. Initially, weight bearing radiographs and foot and ankle clinical scores were assessed. Gait assessment was then performed utilizing pressure insoles (PEDAR®) and inertial sensors (Physilog®) and the two groups were compared using a non-parametric statistical hypothesis test (Wilcoxon rank sum, P<0.05). Furthermore, forward stepwise regression was used to reduce the number of gait parameters to the most clinically relevant and correlation of these parameters was assessed with the clinical score. FINDINGS: Overall, the results showed clear deterioration in several gait parameters in the hallux valgus group compared to controls and 9 gait parameters (effect size between 1.03 and 1.76) were successfully isolated to best describe the altered gait in hallux valgus deformity (r(2)=0.71) as well as showed good correlation with clinical scores. INTERPRETATION: Our results, and nine listed parameters, could serve as benchmark for characterization of hallux valgus and objective evaluation of treatment efficacy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nipple-like nanostructures covering the corneal surfaces of moths, butterflies, and Drosophila have been studied by electron and atomic force microscopy, and their antireflective properties have been described. In contrast, corneal nanostructures of the majority of other insect orders have either been unexamined or examined by methods that did not allow precise morphological characterization. Here we provide a comprehensive analysis of corneal surfaces in 23 insect orders, revealing a rich diversity of insect corneal nanocoatings. These nanocoatings are categorized into four major morphological patterns and various transitions between them, many, to our knowledge, never described before. Remarkably, this unexpectedly diverse range of the corneal nanostructures replicates the complete set of Turing patterns, thus likely being a result of processes similar to those modeled by Alan Turing in his famous reaction-diffusion system. These findings reveal a beautiful diversity of insect corneal nanostructures and shed light on their molecular origin and evolutionary diversification. They may also be the first-ever biological example of Turing nanopatterns.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study proposes a method based on ski fixed inertial sensors to automatically compute spatio-temporal parameters (phase durations, cycle speed and cycle length) for the diagonal stride in classical cross-country skiing. The proposed system was validated against a marker-based motion capture system during indoor treadmill skiing. Skiing movement of 10 junior to world-cup athletes was measured for four different conditions. The accuracy (i.e. median error) and precision (i.e. interquartile range of error) of the system was below 6ms for cycle duration and ski thrust duration and below 35ms for pole push duration. Cycle speed precision (accuracy) was below 0.1m/s (0.005m/s) and cycle length precision (accuracy) was below 0.15m (0.005m). The system was sensitive to changes of conditions and was accurate enough to detect significant differences reported in previous studies. Since capture volume is not limited and setup is simple, the system would be well suited for outdoor measurements on snow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To test if the relationship between knee kinetics during walking and regional patterns of cartilage thickness is influenced by disease severity we tested the following hypotheses in a cross-sectional study of medial compartment osteoarthritis (OA) subjects: (1) the peak knee flexion (KFM) and adduction moments (KAM) during walking are associated with regional cartilage thickness and medial-to-lateral cartilage thickness ratios, and (2) the associations between knee moments and cartilage thickness data are dependent on disease severity. Seventy individuals with medial compartment knee OA were studied. Gait analysis was used to determine the knee moments and cartilage thickness was measured from magnetic resonance imaging. Multiple linear regression analyses tested for associations between cartilage thickness and knee kinetics. Medial cartilage thickness and medial-to-lateral cartilage thickness ratios were lower in subjects with greater KAM for specific regions of the femoral condyle and tibial plateau with no associations for KFM in patients of all disease severities. When separated by severity, the association between KAM and cartilage thickness was found only in patients with more severe OA, and KFM was significantly associated with cartilage thickness only for the less severe OA subjects for specific tibial plateau regions. The results support the idea that the KAM is larger in patients with more severe disease and the KFM has greater influence early in the disease process, which may lessen as pain increases with disease severity. Each component influences different regions of cartilage. Thus the relative contributions of both KAM and KFM should be considered when evaluating gait mechanics and the influence of any intervention for knee OA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modelling the shoulder's musculature is challenging given its mechanical and geometric complexity. The use of the ideal fibre model to represent a muscle's line of action cannot always faithfully represent the mechanical effect of each muscle, leading to considerable differences between model-estimated and in vivo measured muscle activity. While the musculo-tendon force coordination problem has been extensively analysed in terms of the cost function, only few works have investigated the existence and sensitivity of solutions to fibre topology. The goal of this paper is to present an analysis of the solution set using the concepts of torque-feasible space (TFS) and wrench-feasible space (WFS) from cable-driven robotics. A shoulder model is presented and a simple musculo-tendon force coordination problem is defined. The ideal fibre model for representing muscles is reviewed and the TFS and WFS are defined, leading to the necessary and sufficient conditions for the existence of a solution. The shoulder model's TFS is analysed to explain the lack of anterior deltoid (DLTa) activity. Based on the analysis, a modification of the model's muscle fibre geometry is proposed. The performance with and without the modification is assessed by solving the musculo-tendon force coordination problem for quasi-static abduction in the scapular plane. After the proposed modification, the DLTa reaches 20% of activation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of footwear and inclination on running biomechanics over short intervals are well documented. Although recognized that exercise duration can impact running biomechanics, it remains unclear how biomechanics change over time when running in minimalist shoes and on slopes. Our aims were to describe these biomechanical changes during a 50-minute run and compare them to those observed in standard shoes. Thirteen trained recreational male runners ran 50 minutes at 65% of their maximal aerobic velocity on a treadmill, once in minimalist shoes and once in standard shoes, 1 week apart in a random order. The 50-minute trial was divided into 5-minute segments of running at 0%, +5%, and -5% of treadmill incline sequentially. Data were collected using photocells, high-speed video cameras, and plantar-pressure insoles. At 0% incline, runners exhibited reduced leg stiffness and plantar flexion angles at foot strike and lower plantar pressure at the forefoot and toes in minimalist shoes from minute 34 of the protocol onward. However, only reduced plantar pressure at the toes was observed in standard shoes. Overall, similar biomechanical changes with increased exercise time were observed on the uphill and downhill inclines. The results might be due to the unfamiliarity of subjects to running in minimalist shoes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We compared different approaches to analyze running mechanics alterations during repeated treadmill sprints. Thirteen active male athletes performed five 5-second sprints with 25 seconds of recovery on an instrumented treadmill. This approach allowed continuous measurement of running kinetics/kinematics and calculation of vertical and leg stiffness variables that were subsequently averaged over 3 distinct sections of the 5-second sprint (steps 2-5, 7-10, and 12-15) and for all steps (steps 2-15). Independently from the analyzed section, propulsive power and step frequency decreased with fatigue, while contact time and step length increased (P < .05). Except for step frequency, all mechanical variables varied (P < .05) across sprint sections. The only parameters that highly depend on running velocity (propulsive power and vertical stiffness) showed a significant interaction (P < .05) between the analyzed sections, with smaller magnitude of fatigue-induced change observed for steps 2-5. Considering all steps or only a few steps during early, middle, or late phases of 5-second sprints provides similar mechanical outcomes during repeated treadmill sprinting, although acceleration induces noticeable differences between the sections studied. Furthermore, quantifying mechanical alterations from the early acceleration phase may not be readily detectable, and is not recommended.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the past 2 decades, there has been an increase in both basic science research detailing the anatomy and biomechanics of the native posterior cruciate ligament (PCL) and outcome studies evaluating manage- ment of the ruptured PCL. While the methodology of the latter continues to improve, results based on the current level of evidence must be interpreted cautiously (18). The focus of many recent studies has been double-bundle versus single-bundle reconstruction techniques. The theoretical advantage goes to double-bundle techniques, but a clinical difference in outcome has not been consistently demonstrated (8,17). Some biomechanical studies have reported improved control of posterior laxity with double-bundle reconstruc- tion; however, results appear to be more dependent on tunnel position and graft tensioning (13). In acute isolated symptomatic PCL injuries in which the posteromedial bundle and the meniscofemoral ligament remain intact, a single-bundle augmentation procedure may be the preferred surgical technique. In more complex PCL ruptures with associated injuries involving the posterolateral structures (PLS) or medial collateral ligament, more benefit may be derived from double-bundle reconstruction. Again, cadaveric testing of double-bundle PCL reconstruction has not consistently outperformed single-bundle techniques in combined PCL/PLS injury (3). Multi-ligamentous injuries are commonly associated with PCL rupture (15), and their management should be considered carefully in the decision to reconstruct one or both of the functionally dis- tinct PCL bundles. However, the technical complexity of double-bundle reconstruction, the longer surgical time required, as well as the inconclusive clinical outcome are all factors that must be weighed carefully.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biomecánica es la parte de la cibernética aplicada al ser vivo, el hombre gracias al desarrollo de su gran masa encefálica y su enorme diferencia con el resto de los seres vivos ha seguido un proceso evolutivo, que le ha permitido adaptarse y aprender a utilizar su cerebro, es capaz de efectuar hazañas extraordinarias que le hacen superior a cualquier otro ser vivo y le permite reconocer las leyes naturales...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La biomecánica de la carrera de Marathón supone un gran esfuerzo en el comportamiento dinámico del pie. El caso clínico de un corredor de esta especialidad con pies cavas varas y alteración de la marcha, nos demuestra que con un tratamiento ortopodológico adecuado a base de ortesis y soporte plantar obtuvimos resultados satisfactorios.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BIGH3 is a secreted protein, part of the extracellular matrix where it interacts with collagen and integrins on the cell surface. BIGH3 can play opposing roles in cancer, acting as either tumor suppressor or promoter, and its mutations lead to different forms of corneal dystrophy. Although many studies have been carried out, little is known about the physiological role of BIGH3. Using the cre-loxP system, we generated a mouse model with disruption of the Bigh3 genomic locus. Bigh3 silencing did not result in any apparent phenotype modifications, the mice remained viable and fertile. We were able to determine the presence of BIGH3 in the retinal pigment epithelium (RPE). In the absence of BIGH3, a transient decrease in the apoptotic process involved in retina maturation was observed, leading to a transient increase in the INL thickness at P15. This phenomenon was accompanied by an increased activity of the pro-survival ERK pathway.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The kinematics of the anatomical shoulder are analysed and modelled as a parallel mechanism similar to a Stewart platform. A new method is proposed to describe the shoulder kinematics with minimal coordinates and solve the indeterminacy. The minimal coordinates are defined from bony landmarks and the scapulothoracic kinematic constraints. Independent from one another, they uniquely characterise the shoulder motion. A humanoid mechanism is then proposed with identical kinematic properties. It is then shown how minimal coordinates can be obtained for this mechanism and how the coordinates simplify both the motion-planning task and trajectory-tracking control. Lastly, the coordinates are also shown to have an application in the field of biomechanics where they can be used to model the scapulohumeral rhythm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Partial-thickness tears of the supraspinatus tendon frequently occur at its insertion on the greater tubercule of the humerus, causing pain and reduced strength and range of motion. The goal of this work was to quantify the loss of loading capacity due to tendon tears at the insertion area. A finite element model of the supraspinatus tendon was developed using in vivo magnetic resonance images data. The tendon was represented by an anisotropic hyperelastic constitutive law identified with experimental measurements. A failure criterion was proposed and calibrated with experimental data. A partial-thickness tear was gradually increased, starting from the deep articular-sided fibres. For different values of tendon tear thickness, the tendon was mechanically loaded up to failure. The numerical model predicted a loss in loading capacity of the tendon as the tear thickness progressed. Tendon failure was more likely when the tendon tear exceeded 20%. The predictions of the model were consistent with experimental studies. Partial-thickness tears below 40% tear are sufficiently stable to persist physiotherapeutic exercises. Above 60% tear surgery should be considered to restore shoulder strength.