970 resultados para Closed swimming chambers, gas chromatography
Resumo:
CONTEXT: Complex steroid disorders such as P450 oxidoreductase deficiency or apparent cortisone reductase deficiency may be recognized by steroid profiling using chromatographic mass spectrometric methods. These methods are highly specific and sensitive, and provide a complete spectrum of steroid metabolites in a single measurement of one sample which makes them superior to immunoassays. The steroid metabolome during the fetal-neonatal transition is characterized by (a) the metabolites of the fetal-placental unit at birth, (b) the fetal adrenal androgens until its involution 3-6 months postnatally, and (c) the steroid metabolites produced by the developing endocrine organs. All these developmental events change the steroid metabolome in an age- and sex-dependent manner during the first year of life. OBJECTIVE: The aim of this study was to provide normative values for the urinary steroid metabolome of healthy newborns at short time intervals in the first year of life. METHODS: We conducted a prospective, longitudinal study to measure 67 urinary steroid metabolites in 21 male and 22 female term healthy newborn infants at 13 time-points from week 1 to week 49 of life. Urine samples were collected from newborn infants before discharge from hospital and from healthy infants at home. Steroid metabolites were measured by gas chromatography-mass spectrometry (GC-MS) and steroid concentrations corrected for urinary creatinine excretion were calculated. RESULTS: 61 steroids showed age and 15 steroids sex specificity. Highest urinary steroid concentrations were found in both sexes for progesterone derivatives, in particular 20α-DH-5α-DH-progesterone, and for highly polar 6α-hydroxylated glucocorticoids. The steroids peaked at week 3 and decreased by ∼80% at week 25 in both sexes. The decline of progestins, androgens and estrogens was more pronounced than of glucocorticoids whereas the excretion of corticosterone and its metabolites and of mineralocorticoids remained constant during the first year of life. CONCLUSION: The urinary steroid profile changes dramatically during the first year of life and correlates with the physiologic developmental changes during the fetal-neonatal transition. Thus detailed normative data during this time period permit the use of steroid profiling as a powerful diagnostic tool.
Resumo:
The fight against doping in sports has been governed since 1999 by the World Anti-Doping Agency (WADA), an independent institution behind the implementation of the World Anti-Doping Code (Code). The intent of the Code is to protect clean athletes through the harmonization of anti-doping programs at the international level with special attention to detection, deterrence and prevention of doping.1 A new version of the Code came into force on January 1st 2015, introducing, among other improvements, longer periods of sanctioning for athletes (up to four years) and measures to strengthen the role of anti-doping investigations and intelligence. To ensure optimal harmonization, five International Standards covering different technical aspects of the Code are also currently in force: the List of Prohibited Substances and Methods (List), Testing and Investigations, Laboratories, Therapeutic Use Exemptions (TUE) and Protection of Privacy and Personal Information. Adherence to these standards is mandatory for all anti-doping stakeholders to be compliant with the Code. Among these documents, the eighth version of International Standard for Laboratories (ISL), which also came into effect on January 1st 2015, includes regulations for WADA and ISO/IEC 17025 accreditations and their application for urine and blood sample analysis by anti-doping laboratories.2 Specific requirements are also described in several Technical Documents or Guidelines in which various topics are highlighted such as the identification criteria for gas chromatography (GC) and liquid chromatography (LC) coupled to mass spectrometry (MS) techniques (IDCR), measurements and reporting of endogenous androgenic anabolic agents (EAAS) and analytical requirements for the Athlete Biological Passport (ABP).
Resumo:
The cuticle is an essential diffusion barrier on aerial surfaces of land plants whose structural component is the polyester cutin. The PERMEABLE CUTICLE1/ABCG32 (PEC1) transporter is involved in plant cuticle formation in Arabidopsis. The gpat6 pec1 and gpat4 gapt8 pec1 double and triple mutants are characterized. Their PEC1-specific contributions to aliphatic cutin composition and cuticle formation during plant development are revealed by gas chromatography/mass spectrometry and Fourier-transform infrared spectroscopy. The composition of cutin changes during rosette leaf expansion in Arabidopsis. C16:0 monomers are in higher abundance in expanding than in fully expanded leaves. The atypical cutin monomer C18:2 dicarboxylic acid is more prominent in fully expanded leaves. Findings point to differences in the regulation of several pathways of cutin precursor synthesis. PEC1 plays an essential role during expansion of the rosette leaf cuticle. The reduction of C16 monomers in the pec1 mutant during leaf expansion is unlikely to cause permeability of the leaf cuticle because the gpat6 mutant with even fewer C16:0 monomers forms a functional rosette leaf cuticle at all stages of development. PEC1/ABCG32 transport activity affects cutin composition and cuticle structure in a specific and non-redundant fashion.
Resumo:
Thermal processes are widely used in small molecule chemical analysis and metabolomics for derivatization, vaporization, chromatography, and ionization, especially in gas chromatography mass spectrometry (GC/MS). In this study the effect of heating was examined on a set of 64 small molecule standards and, separately, on human plasma metabolite extracts. The samples, either derivatized or underivatized, were heated at three different temperatures (60, 100, and 250 °C) at different exposure times (30 s, 60 s, and 300 s). All the samples were analyzed by liquid chromatography coupled to electrospray ionization mass spectrometry (LC/MS) and the data processed by XCMS Online ( xcmsonline.scripps.edu ). The results showed that heating at an elevated temperature of 100 °C had an appreciable effect on both the underivatized and derivatized molecules, and heating at 250 °C created substantial changes in the profile. For example, over 40% of the molecular peaks were altered in the plasma metabolite analysis after heating (250 °C, 300s) with a significant formation of degradation and transformation products. The analysis of 64 small molecule standards validated the temperature-induced changes observed on the plasma metabolites, where most of the small molecules degraded at elevated temperatures even after minimal exposure times (30 s). For example, tri- and diorganophosphates (e.g., adenosine triphosphate and adenosine diphosphate) were readily degraded into a mono-organophosphate (e.g., adenosine monophosphate) during heating. Nucleosides and nucleotides (e.g., inosine and inosine monophosphate) were also found to be transformed into purine derivatives (e.g., hypoxanthine). A newly formed transformation product, oleoyl ethyl amide, was identified in both the underivatized and derivatized forms of the plasma extracts and small molecule standard mixture, and was likely generated from oleic acid. Overall these analyses show that small molecules and metabolites undergo significant time-sensitive alterations when exposed to elevated temperatures, especially those conditions that mimic sample preparation and analysis in GC/MS experiments.
Resumo:
The combination of high performance exclusion chromatography (HPEC) and gas chromatography (GC) was applied to the analysis of six coffee samples that were previously characterized by sensory tests as of good or poor quality. The data obtained by the two techniques were statistically evaluated by "Principal Components Analysis" (PCA) using selected peak areas. The results showed the potential of the described techniques for coffee analysis. The HPEC technique monitored with the U.V. detector at 272 nm and followed by PCA may be correlated with sensorial data, particularly if a wider group of samples is used.
Resumo:
A simple chemical method has been developed to quantify the silanol groups (º Si-OH) in silica as well as in coated chromatographic supports for use in packed - column Gas Chromatography. After adsorption of 10 mg/mL methylene blue, centrifuging action and filtration, the absorbance of the solution was inversely proportional to the silanol quantity. The difference between the absorbance of the pure solution and that of the solid - free filtrate was related to the silica weight, yielding a quantitative analysis of these groups.
Resumo:
Copaiba oil is a resin extracted from the trunk of trees of Copaifera species which grow in Brazil where it is widely used in popular medicine as an anti-inflammatory, antiseptic anti-bactericidal, diuretic, dermatological, expectorant, and anti-infective. The comparative study of the composition of commercial copaiba oils was carried out by high resolution gas chromatography (HRGC) and high resolution gas chromatography-mass spectrometry (HRGC-MS) analysis. The commercial oils were compared with authentic oils, collected from the southeast and northern regions of Brazil. Sixteen commercial oils were analysed and two of them revealed adulterations with fatty acids. Using the chromatographic profile of authentic copaiba species oils, it is possible to analyse commercial oils and determine the authenticity of these materials.
Resumo:
Hexafluoroacetylaceton derivatives of some synthesized components of the guazatine fungicide were prepared, and their separation and identification performed through gas chromatography and gas chromatography-mass spectrometry. The chromatogram obtained from hexafluoroacetylacetone derivative of the commercial guazatine presented 14 major peaks, and 9 of them were identified through both techniques mentioned above.
Resumo:
The present work describes a rapid and sensitive method for the determination of carbon monoxide and carbon dioxide at low concentration levels, on line, in ethylene and hydrogen lines. These gases were separated in a column filled with Porapak Q, converted to methane and quantified by a flame ionization detector. Some modifications were made in the injection system and in the lines of the carrier gas. The detection limits of 2,6 ppbV and 4,85 ppbV for CO and CO2, respectively, were reached after modifications.
Resumo:
The herbicides are being used in huge quantities for various porpouses. Once the herbicide finds its way into the environment, a major part of it comes in contact with soil. Humic substances are major organic constituents of soil. These substances may interact with herbicides in different modes and adsorption is probably the most important one. Adsorption will control the quantity of herbicide in the soil solution, and determines its persistence, leaching, mobility and bioavailability. In this work we studied the interaction between the herbicide 2,4D and soil in the presence and absence of organic matter. The methodology utilized for the determination of 2,4D was gas chromatography with eletron capture detector. The behavior of 2,4D was evaluated through Freundlich isotherms. It was verified that the herbicide 2,4D has a large adsorption in the humic acid .
Resumo:
In this work the contamination, by organochlorinated, of a drinking water source located in the region of Viçosa, MG, was evaluated. The identification and quantification of the analytes was carried out using a gas-chromatograph equipped with an electron capture detector after liquid-liquid extraction and concentration. Four insecticides, Aldrin, Epoxy heptachloride, Endrin and op'- DDT were detected in concentrations that are higher than the safety limits established in the Brazilian legislation.
Resumo:
The hexane and methanolic extracts from pheromonal glands of Castnia licus (Drury) virgin females have been studied. Analyses by gas chromatography and mass spectrometry allowed us to determine the major constituents present in the hexane extract as n-alkanes C21 to C30, (Z)-9-hexadecenoic acid (C16), and (Z)-9-octadecenoic acid (C18) and hexadecanoic acid (C16). Aldehyds, alkenes and acetates were also detected in low concentrations in the extracts. Female pheromone glands were analysed for pheromone precursors using the methanolic extract. In addition to the compounds methyl hexadecanoate and methyl (Z)-9-octadecenoate, the glandular tissue contains a homologous series of methyl esters from C12 to C24. The hexane extract of the female abdomenal glands elicited activity from males in a behavioural bioassay.
Resumo:
This work discusses sample preparation processes for gas chromatography (GC) based on the technique of extraction through membrane permeation (MPE). The MPE technique may be easily coupled to GC via a relatively simple device, which is a module that holds the membrane and is directly connected to the GC column. The possibility of operational errors due to sample handling is substantially reduced in an MPE-GC system because the sample preparation and the chemical analysis are accomplished as a one-step process. The MPE technique is of relatively wide application as it can be used for aqueous samples, solid samples and gaseous samples. Depending on the type of sample the extraction is performed with the membrane in direct contact with the sample or in contact with its headspace. The MPE-GC technique is very useful in trace analysis, due to the time-dependent enrichment of the analyte. A typical application of MPE-GC is the analysis of VOCs present in water that may be accomplished with detection limits at the low ppb (mugL-1) level.
Resumo:
The developments in stationary phase synthesis and capillary column technology, have opened new perspectives in analysis of high molecular mass compounds (³600 daltons) and thermolabile organic compounds by High Temperature High Resolution Gas Chromatography (HT-HRGC). HT-HRGC is a new analytical borderline and its application to the analysis of high molecular mass compounds is still in its infancy. The apolar and medium polar gum phases can now be operated at temperatures up to 400-480ºC, being used for the analysis of n-alcanes up to C-100, lipids, oligosaccharides, industrial resins, polyglycerols, cyclodextrins, porphyrins, etc. This technique should play a leading role as a powerful tool, for many different analysis types, in multidisciplinary fields of Science.
Resumo:
The analysis of water samples containing volatile organic compounds has become an important task in analytical chemistry. Gas chromatography has been widely used for the analysis of volatile organic compounds in water. The headspace analysis shows as a principal characteristic the possibility of determination of the volatile components in drinking water. Benzene, Toluene and Xylene (BTX) are important compounds usually present in drinking water, from contamination by petroleum derivatives. Since they are toxic compounds even when present in low concentration levels, their determination is important in order to define the quality of the water. The sampling technique using headspace, coupled with gas chromatography as the separation method, showed to be suitable for BTX analysis in several samples at the mug/L (ppb) level.