976 resultados para CONGENITAL ONYCHODYSPLASIA
Resumo:
Mestrado em Fisioterapia.
Resumo:
OBJECTIVE: To assess the performance of the rubella suspect case definition among patients with rash diseases seen at primary care units. METHODS: From January 1994 to December 2002, patients with acute rash, with or without fever, were seen at two large primary health care units and at a public general hospital in the municipality of Niterói, metropolitan area of Rio de Janeiro, Brazil. Data from clinical and serologic assessment were used to estimate the positive predictive values of the definition of rubella suspect case from the Brazilian Ministry of Health and other combination of signs/symptoms taking serologic status as the reference. Serum samples were tested for anti-rubella virus IgM using commercially available enzyme immunoassays. Positive predictive values and respective 95% confidence intervals were calculated. RESULTS: A total of 1,186 patients with an illness characterized by variable combinations of rash with fever, arthropathy and lymphadenopathy were studied. Patients with rash, regardless of other signs and symptoms, had 8.8% likelihood of being IgM-positive for rubella. The Brazilian suspect case definition (fever and lymphadenopathy in addition to rash) had low predictive value (13.5%). This case definition would correctly identify 42.3% of the IgM-positive cases, and misclassify 26.1% of the IgM-negative cases. CONCLUSIONS: These results support the recommendation to investigate and collect clinical specimens for laboratory diagnosis of all cases of rash, for surveillance purposes. Although this strategy may increase costs, the benefits of interrupting the circulation of rubella virus and preventing the occurrence of congenital rubella syndrome should pay off.
Resumo:
OBJECTIVE: To determine the prevalence of reagent serology for suspected acute toxoplasmosis in pregnant women and to describe clinical, laboratory and therapeutic profiles of mothers and their children. METHODS: A retrospective study was conducted with IgM-anti-Toxoplasma gondii-reagent pregnant women and their children who attended the public health system in the state of Paraná, Southern Brazil, from January 2001 to December 2003. Information were obtained from clinical, laboratory (ELISA IgM/IgG) and ultrasonographic data and from interviews with the mothers. To test the homogeneity of the IgM indices in relation to the treatment used, the Pearson's Chi-square test was applied. Comparisons were considered significant at a 5% level. RESULTS: Two hundred and ninety (1.0%) cases of suspected IgM-reagent infection were documented, with a prevalence of 10.7 IgM-reagent women per 1,000 births. Prenatal care started within the first 12 weeks for 214/290; 146/204 were asymptomatic. Frequent complaints included headaches, visual disturbance and myalgia. Ultrasonography revealed abnormalities in 13 of 204 pregnancies. Chemoprophylaxis was administered to 112/227; a single ELISA test supported most decisions to begin treatment. Pregnant women with IgM indices =2.000 tended to be treated more often. Among exposed children, 44/208 were serologically followed up and all were IgG-reagent, and three IgM-reagent cases showed clinical symptoms. CONCLUSIONS: The existence of pregnant women with laboratorially suspected acute toxoplasmosis who were not properly followed up, and of fetuses that were not adequately monitored, shows that basic aspects of the prenatal care are not being systematically observed. There is need of implementing a surveillance system of pregnant women and their children exposed to T. gondii.
Resumo:
OBJECTIVE: To assess risk factors for antepartum fetal deaths. METHODS: A population-based case-control study was carried out in the city of São Paulo from August 2000 to January 2001. Subjects were selected from a birth cohort from a linked birth and death certificate database. Cases were 164 antepartum fetal deaths and controls were drawn from a random sample of 313 births surviving at least 28 days. Information was collected from birth and death certificates, hospital records and home interviews. A hierarchical conceptual framework guided the logistic regression analysis. RESULTS: Statistically significant factors associated with antepartum fetal death were: mother without or recent marital union; mother's education under four years; mothers with previous low birth weight infant; mothers with hypertension, diabetes, bleeding during pregnancy; no or inadequate prenatal care; congenital malformation and intrauterine growth restriction. The highest population attributable fractions were for inadequacy of prenatal care (40%), hypertension (27%), intrauterine growth restriction (30%) and absence of a long-standing union (26%). CONCLUSIONS: Proximal biological risk factors are most important in antepartum fetal deaths. However, distal factors - mother's low education and marital status - are also significant. Improving access to and quality of prenatal care could have a large impact on fetal mortality.
Resumo:
OBJECTIVE: To assess the effect of hospital of birth on neonatal mortality. METHODS: A birth cohort study was carried out in Pelotas, Southern Brazil, in 2004. All hospital births were assessed by daily visits to all maternity hospitals and 4558 deliveries were included in the study. Mothers were interviewed regarding potential risk factors. Deaths were monitored through regular visits to hospitals, cemeteries and register offices. Two independent pediatricians established the underlying cause of death based on information obtained from medical records and home visits to parents. Logistic regression was used to estimate the effect of hospital of birth, controlling for confounders related to maternal and newborn characteristics, according to a conceptual model. RESULTS: Neonatal mortality rate was 12.7 and it was highly influenced by birthweight, gestational age, and socioeconomic variables. Immaturity was responsible for 65% of neonatal deaths, followed by congenital anomalies, infections and intrapartum asphyxia. Adjusting for maternal characteristics, a three-fold increase in neonatal mortality was seen between similar complexity hospitals. The effect of hospital remained, though lower, after controlling for newborn characteristics. CONCLUSIONS: Neonatal mortality was high, mainly related to immaturity, and varied significantly across maternity hospitals. Further investigations comparing delivery care practices across hospitals are needed to better understand NMR variation and to develop strategies for neonatal mortality reduction.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Imagem por Ressonância Magnética
Resumo:
Mestrado em Fisioterapia
Resumo:
Introdução – O efeito de êmbolo é um dos principais problemas relacionados com a eficácia de uma prótese. Uma diminuição do mesmo pode levar a uma marcha mais natural através do aumento da propriocetividade. Objetivos – Verificar se existe diferença de valores do efeito de êmbolo entre vários sistemas de suspensão para próteses transtibiais com a utilização de Liners e testar a aplicação de testes de imagiologia na análise da melhor solução protésica para um determinado indivíduo. Metodologia – Foi obtida uma radiografia da prótese em carga na posição ortostática, mantendo o peso do indivíduo igualmente distribuído pelos dois pés. Seguidamente foi realizada outra radiografia no plano sagital com o joelho com 30° de flexão, com a prótese suspensa e um peso de 5kg aplicado na extremidade distal da mesma durante 30 seg. Através destes dois exames efetuaram-se as medições do êmbolo para cada tipo de sistema de suspensão. Resultados – Dos quatro sistemas estudados apenas três apresentam valores de êmbolo, visto que um dos sistemas não criou suspensão suficiente para suportar o peso colocado na extremidade distal da prótese. Através das medições realizadas nos exames imagiológicos dos três sistemas pudemos encontrar variações de efeito de êmbolo que vão dos 47,91mm aos 72,55mm. Conclusão – Através da realização do estudo imagiológico verificaram-se diferenças a nível do efeito de êmbolo nos vários sistemas de suspensão, provando que esta é uma ferramenta viável na avaliação do mesmo. Também através da análise dos resultados ficou notório que o sistema de suspensão Vacuum Assisted Suspention System (VASS) é o que apresenta menos êmbolo.
Resumo:
OBJECTIVE Determine the coverage rate of syphilis testing during prenatal care and the prevalence of syphilis in pregnant women in Brazil. METHODS This is a national hospital-based cohort study conducted in Brazil with 23,894 postpartum women between 2011 and 2012. Data were obtained using interviews with postpartum women, hospital records, and prenatal care cards. All postpartum women with a reactive serological test result recorded in the prenatal care card or syphilis diagnosis during hospitalization for childbirth were considered cases of syphilis in pregnancy. The Chi-square test was used for determining the disease prevalence and testing coverage rate by region of residence, self-reported skin color, maternal age, and type of prenatal and child delivery care units. RESULTS Prenatal care covered 98.7% postpartum women. Syphilis testing coverage rate was 89.1% (one test) and 41.2% (two tests), and syphilis prevalence in pregnancy was 1.02% (95%CI 0.84;1.25). A lower prenatal coverage rate was observed among women in the North region, indigenous women, those with less education, and those who received prenatal care in public health care units. A lower testing coverage rate was observed among residents in the North, Northeast, and Midwest regions, among younger and non-white skin-color women, among those with lower education, and those who received prenatal care in public health care units. An increased prevalence of syphilis was observed among women with < 8 years of education (1.74%), who self-reported as black (1.8%) or mixed (1.2%), those who did not receive prenatal care (2.5%), and those attending public (1.37%) or mixed (0.93%) health care units. CONCLUSIONS The estimated prevalence of syphilis in pregnancy was similar to that reported in the last sentinel surveillance study conducted in 2006. There was an improvement in prenatal care and testing coverage rate, and the goals suggested by the World Health Organization were achieved in two regions. Regional and social inequalities in access to health care units, coupled with other gaps in health assistance, have led to the persistence of congenital syphilis as a major public health problem in Brazil.
Resumo:
Human term placental villi cultured ''in vitro" were maintained with bloodstream forms of Trypanosoma cruzi during various periods of time. Two different concentrations of the parasite were employed. Controls contained no T. cruzi. The alkaline phosphatase activity was determined in placental villi by electron microscopy and its specific activity in the culture medium by biochemical methods. Results showed that the hemoflagellate produces a significant decrease in enzyme activity as shown by both ultracytochemical and specific activity studies and this activity was lower in cultures with high doses of parasites. The above results indicate that the reduction in enzyme activity coincides with the time of penetration and proliferation of T. cruzi in mammalian cells. These changes may represent an interaction between human trophoblast and T. cruzi.
Resumo:
The author emphasizes the importance of the congenital transmission of Chagas' disease and discusses the possible risk factors for transmission such as age, origin, obstetrical history and maternal form of disease. Exacerbation of infection during pregnancy is also considered as a possible risk factor for transmission. Besides, a relationship between the frequency of transmission and gestational age is presented. Concerning breast-feeding, the risk of transmission is directly related to the acute phase of maternal disease and bleeding nipples. The deleterious effects of chagasic infection on the fetus and newborn are also considered.
Resumo:
The surface of human syncytiotrophoblast does not induce maternal blood platelet aggregation even though it is not an endothelium. It can be surmised that as occurs in endothelial injury the subcellular components of the syncytiotrophoblast may have pro-or antiaggregatory activity. During congenital Chagas' disease which is associated to trophoblast lesions, platelets may play a role in the development of T. cruzi-induced placentitis. In the present work the aggregatory behaviour of normal human blood platelets was recorded after their challenging with subcellular fractions of syncytiotrophoblast isolated from normal and chagasic women. Nuclear, Mitochondrial, Microsomal and Supernatant fractions isolated from normal and chagasic syncytiotrophoblast failed to induce per se any aggregatory reaction on platelets. When samples of platelet-rich plasma (PRP) were preincubated with normal and chagasic nuclear fractions and then stimulated with collagen at threshold level (CT-PRP) an inhibition of the aggregatory response was observed. Treatment of CT-PRP with normal and chagasic mitochondrial fractions induced inhibition of platelet aggregation whereas only chagasic fraction reduced latency time. Microsornal fraction from normal placentas showed no significant effects on platelet aggregation. It is concluded that subcellular fractions of normal human syncytiotrophoblast do not exhibit any effect on platelet aggregation, whereas those subcellular fractions enriched in intracellular membrane components isolated from chagasic placentas inhibit platelet aggregation.
Resumo:
Resumo O vírus citomegálico humano (CMV) é o principal agente de infecção congénita, atingindo cerca de 0.2 a 2.2% de todos os recém-nascidos. As crianças que nascem infectadas por este vírus têm cerca de 11% a 12.7% de probabilidades de apresentarem sintomas e sinais de doença citomegálica ao nascimento, podendo cerca de 40 a 58% destas virem a apresentar sequelas neurológicas permanentes. Das crianças infectadas que terão infecção assintomática no período neo-natal, 5 a 15% poderão vir igualmente a sofrer de sequelas tardias, sobretudo a surdez ou o atraso mental. Em Portugal, desconhece-se a dimensão deste problema. O primeiro objectivo desta dissertação foi, desta forma, a determinação da prevalência através do recurso aos cartões do diagnóstico precoce (“Guthrie cards”), utilizando uma técnica de nested-PCR dirigida para o vírus. Foram estudados 3600 cartões, seleccionados de todo o território nacional (continente e ilhas), de uma forma proporcional ao número de nascimentos em cada distrito, dos quais 38 foram positivos, o que dá uma prevalência de 1.05% (intervalo de confiança para 95%: 0.748-1.446). A revisão sobre a experiência acumulada nos últimos 15 anos, na área do diagnóstico pré-natal, juntamente com um estudo adicional sobre a técnica da avidez, permitiu retirar algumas ilações, nomeadamente que este diagnóstico constitui uma arma diagnostica fiável para a avaliação pré-natal desta infecção congénita e que a selecção dos casos para amniocentese deverá obedecer a indicações serológicas precisas, como a “seroconversão para IgG” ou a “IgM confirmada” (devendo o método de confirmação ser a avidez das IgG com um índice <0,6) e as alterações ecográficas de etiologia não esclarecida. A possibilidade de utilizar pools de urinas para detectar a infecção congénita por CMV foi abordada na terceira parte do trabalho experimental. A metodologia aí descrita teve correlação total com o método de referência, permitindo uma redução bastante significativa nos tempos de execução e nos custos em consumíveis, pelo que abre a possibilidade da sua utilização para o rastreio da infecção congénita por CMV nos recém-nascidos.
Resumo:
Dengue congenital disease was not confirmed in 10 children whose mothers had the infection during pregnancy. The fetal sera presented anti-dengue IgG antibodies which progressively declined, and disappeared after 8 months. IgM antibodies to dengue were not observed in the sera. Other normal data suggesting the healthy state of the children included: absence of malformations, pregnancy time, Apgar index, weight, and placenta aspect
Resumo:
RESUMO: Contexto: Indicadores fidedignos da composição corporal são importantes na orientação das estratégias nutricionais de recém-nascidos e pequenos lactentes submetidos a cuidados intensivos. O braço é uma região acessível para avaliar a composição corporal regional, pela medida dos seus compartimentos. A antropometria e a ultrassonografia (US) são métodos não invasivos, relativamente económicos, que podem ser usados à cabeceira do paciente na medição desses compartimentos, embora esses métodos não tenham ainda sido validados neste subgrupo etário. A ressonância magnética (RM) pode ser usada como método de referência na validação da medição dos compartimentos do braço. Objectivo: Validar em lactentes pré-termo, as medidas do braço por antropometria e por US. Métodos: Foi estudada uma coorte de recém-nascidos admitidos consecutivamente na unidade de cuidados intensivos neonatais, com 33 semanas de idade de gestação e peso adequado para a mesma, sem anomalias congénitas major e não submetidas a diuréticos ou oxigenoterapia no momento da avaliação. Nas vésperas da alta, foram efectuadas medições do braço, com ocultação, pelos métodos antropométrico, ultrassonográfico e RM. As medidas antropométricas directas foram: peso (P), comprimento (C), perímetro cefálico (PC), perímetro braquial (PB) e prega cutânea tricipital (PT). As área braquial total, área muscular (AM) e área adiposa foram calculadas pelos métodos de Jeliffee & Jeliffee e de Rolland-Cachera. Utilizando uma sonda PSH-7DLT de 7 Hz no ecógrafo Toshiba SSH 140A foram medidos os perímetros braquial e muscular e calculadas automaticamente as áreas braquial e muscular, sendo a área adiposa obtida por subtracção. Como método de referência foi utilizada a RM – Philips Gyroscan ACS-NT, Power-Track 1000 ®, 1.5 Tesla com uma antena de quadratura do joelho. Na análise estatística foram utilizados os métodos paramétricos e não paramétricos, conforme adequado. Resultados: Foram incluídas 30 crianças, nascidas com ( ±DP) 30.7 ±1.9 semanas de gestação, pesando 1380 ±325g, as quais foram avaliadas às 35.4 ±1.1 semanas de idade corrigida, quando pesavam 1786 ±93g. Nenhuma das medidas antropométricas, individualmente, constitui um indicador aceitável (r2 <0.5) das medições por RM. A melhor e mais simples equação alternativa encontrada é a que estima a AM (r2 = 0.56), derivada dos resultados da análise de regressão múltipla: AMRM = (P x 0.17) + (PB x 5.2) – (C x 6) – 150, sendo o P expresso em g, o C e o PB em cm. Nenhuma das medidas ultrassonográficas constitui um indicador aceitável (r2 <0.4) das medições por RM. Conclusões: A antropometria e as medidas ultrassonográficas do braço não são indicadores fidedignos da composição corporal regional em lactentes pré-termo, adequados para a idade de gestação.----------ABSTRACT: Background: Accurate predictors for body composition are valuable tools guiding nutritional strategies in infants needing intensive care. The upper-arm is a part of the body that is easily accessible and convenient for assessing the regional body composition, throughout the assessment of their compartments. Anthropometry and by ultrasonography (US) are noninvasive and relatively nonexpensive methods for bedside assessment of the upper-arm compartments. However, these methods have not yet been validated in infants. Magnetic resonance imaging (MRI) may be used as gold standard to validate the measurements of the upper-arm compartments. Objective: To validate the upper-arm measurements by anthropometry and by US in preterm infants. Methods: A cohort of neonates consecutively admitted at the neonatal intensive care unit, appropriate for gestational age, with 33 weeks, without major congenital abnormalities and not subjected to diuretics or oxygen therapy, was assessed. Before the discharge, the upper-arm was blindly measured by anthropometry, US and MRI. The direct anthropometric parameters measured were: weight (W), length (L), head circumference (HC), mid-arm circumference (MAC), and tricipital skinfold thickness. The arm area (AA), arm muscle area (AMA) and arm fat area were calculated applying the methods proposed by Jeliffee & Jeliffee and by Rolland-Cachera. Using the sonolayer Toshiba SSH 140A and the probe PSH-7DLT 7Hz, the arm and muscle perimeters were measured by US, the arm and muscle areas included were automatically calculated, and the fat area was calculated by subtraction. The MR images were acquired on a 1.5-T Philips Gyroscan ACS-NT, Power-Track 1000 scanner, and a knee coil was chosen for the upper-arm measurements. For statistical analysis parametric and nonparametric methods were used as appropriate. Results: Thirty infants born with ( ±SD) 30.7 ±1.9 weeks of gestational age and weighing 1380 ±325g were included in the study; they were assessed at 35.4 ±1.1 weeks of corrected age, weighing 1786 ±93g. None of the anthropometric measurements are individually acceptable (r2 <0.5) for prediction of the measurements obtained by MRI. The best and simple alternative equation found is the equation for prediction of the AMA (r2 = 0.56), derived from the results of multiple regression analysis: AMARM = (W x 0.17) + (MAC x 5.2) – (L x 6) – 150, being the W expressed in g, and L and MAC in cm. None of the ultrasonographic measurements are acceptable (r2 <0.5) predictors for the measurements obtained by MRI. Conclusions: The measurements of the upper-arm by anthropometry and by US are not accurate predictors for the regional body composition in preterm appropriate for gestational age infants.