The coordination of design is a multi-faceted problem in construction. In design interactions in particular the real-time coordination of design activity is a persistent concern. The use of objects to coordinate the activity of design is studied as this happens in interactions between an architect and a building user group, in a setting where maintaining awareness of the design situation is important. An account of ways in which this was accomplished and how design activity is coordinated through interactional practices is provided. The empirical analyses examine design interaction from an ethnomethodological/conversation analysis (EM/CA) informed perspective to examine: ways in which mutual orientation to design issues are accomplished, how objects can provide a resource for the recognition of the activities of others and ways in which objects might be observable as momentarily intelligible. Subtle interactional practices involving talk, gesture and gaze were some of the small ways in which mutual orientation to the design actions of others became observable. The production of actions sequentially, in response to another's action, marked the real-time coordination of design moves in this setting. The relevance of accounts of micro-interaction to develop understanding of design activity and how it is coordinated are considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bis-valine derivatives or malonamide (Guha,S.; Drew, M.G.B. Small 2008, 4, 1993-2005) and a bis-valine derivative of 1,1-cyclopropone dicarboxamide were used as building blocks for the construction of supramolecular helical structures. The six-membered intramolecular hydrogen-bonded scaffold is formed, and this acts as a unique supramolecular synthon for the construction of a pseudopeptide-based supramolecular helical structure. However, in absence of this intramolecular hydrogen bond. intermolecular hydrogen bonds are formed among the peptide strands. This leads to a supramolecular beta-sheet structure. Proper selection of the supramolecular synthon (six-membered intramolecular hydrogenbonded scaffold) promotes supramolecular helix formation, and a deviation from this molecular structure dictates the disruption of supramolecular helicity. In this study, six crystal structures have been used to demonstrate that a change in the central angle and/or the central core structure of dicarboxamides can be used to design either a supramolecular helix or a beta-sheet.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As digital technologies become widely used in designing buildings and infrastructure, questions arise about their impacts on construction safety. This review explores relationships between construction safety and digital design practices with the aim of fostering and directing further research. It surveys state-of-the-art research on databases, virtual reality, geographic information systems, 4D CAD, building information modeling and sensing technologies, finding various digital tools for addressing safety issues in the construction phase, but few tools to support design for construction safety. It also considers a literature on safety critical, digital and design practices that raises a general concern about ‘mindlessness’ in the use of technologies, and has implications for the emerging research agenda around construction safety and digital design. Bringing these strands of literature together suggests new kinds of interventions, such as the development of tools and processes for using digital models to promote mindfulness through multi-party collaboration on safety

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Demands for thermal comfort, better indoor air quality together with lower environmental impacts have had ascending trends in the last decade. In many circumstances, these demands could not be fully covered through the soft approach of bioclimatic design like optimisation of the building orientation and internal layout. This is mostly because of the dense urban environment and building internal energy loads. In such cases, heating, ventilation, air-conditioning and refrigeration (HVAC&R) systems make a key role to fulfill the requirements of indoor environment. Therefore, it is required to select the most proper HVAC&R system. In this study, a robust decision making approach for HVAC&R system selection is proposed. Technical performance, economic aspect and environmental impacts of 36 permutations of primary and secondary systems are taken into account to choose the most proper HVAC&R system for a case study office building. The building is a representative for the dominant form of office buildings in the UK. Dynamic performance evaluation of HVAC&R alternatives using TRNSYS package together with life cycle energy cost analysis provides a reliable basis for decision making. Six scenarios broadly cover the decision makers' attitudes on HVAC&R system selection which are analysed through Analytical Hierarchy Process (AHP). One of the significant outcomes reveals that, despite both the higher energy demand and more investment requirements associated with compound heating, cooling and power system (CCHP); this system is one of the top ranked alternatives due to the lower energy cost and C02 emissions. The sensitivity analysis reveals that in all six scenarios, the first five top ranked alternatives are not changed. Finally, the proposed approach and the results could be used by researchers and designers especially in the early stages of a design process in which all involved bodies face the lack of time, information and tools for evaluation of a variety of systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rapid urbanisation in China has resulted in great demands for energy, resources and pressure on the environment. The progress in China's development is considered in the context of energy efficiency in the built environment, including policy, technology and implementation. The key research challenges and opportunities are identified for delivering a low carbon built environment. The barriers include the existing traditional sequential design process, the lack of integrated approaches, and insufficient socio-technical knowledge. A proposed conceptual systemic model of an integrated approach identifies research opportunities. The organisation of research activities should be initiated, operated, and managed in a collaborative way among policy makers, professionals, researchers and stakeholders. More emphasis is needed on integrating social, economic and environmental impacts in the short, medium and long terms. An ideal opportunity exists for China to develop its own expertise, not merely in a technical sense but in terms of vision and intellectual leadership in order to flourish in global collaborations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The built environment in China is required to achieve a 50% reduction in carbon emissions by 2020 against the 1980 design standard. A particular challenge is how to maintain acceptable comfort conditions through the hot humid summers and cold desiccating winters of its continental climate regions. Fully air-conditioned sealed envelopes, often fully glazed, are becoming increasingly common in these regions. Remedial strategies involve technical refinements to the air-handling equipment and a contribution from renewable energy sources in an attempt to achieve the prescribed net reduction in energy use. However an alternative hybrid environmental design strategy is developed in this research project. It exploits observed temperate periods of weeks, days, even hours in duration to free-run an office and exhibition building configured to promote natural stack ventilation when ambient conditions permit and mechanical ventilation when conditions require it, the two modes delivered through the same physical infrastructure. The proposal is modelled in proprietary software and the methodology adopted is described. The challenge is compounded by its first practical application to an existing reinforced concrete frame originally designed to receive a highly glazed envelope. This original scheme is reviewed in comparison. Furthermore the practical delivery of the proposal value engineered out a proportion of the ventilation stacks. The likely consequence of this for the environmental performance of the building is investigated through a sensitivity study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This chapter aims to provide an overview of building simulation in a theoretical and practical context. The following sections demonstrate the importance of simulation programs at a time when society is shifting towards a low carbon future and the practice of sustainable design becomes mandatory. The initial sections acquaint the reader with basic terminology and comment on the capabilities and categories of simulation tools before discussing the historical development of programs. The main body of the chapter considers the primary benefits and users of simulation programs, looks at the role of simulation in the construction process and examines the validity and interpretation of simulation results. The latter half of the chapter looks at program selection and discusses software capability, product characteristics, input data and output formats. The inclusion of a case study demonstrates the simulation procedure and key concepts. Finally, the chapter closes with a sight into the future, commenting on the development of simulation capability, user interfaces and how simulation will continue to empower building professionals as society faces new challenges in a rapidly changing landscape.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of the surrounding lower buildings on the wind pressure distribution on a high-rise building is investigated by computational fluid dynamics (CFD). When B/H=0.1, it is found that the wind pressure on the windward side was reduced especially on the lower part, but for different layers of surrounding buildings, there was no great difference, which agrees with our previous wind tunnel experiment data. Then we changed the aspect ratio from 0.1 to 2, to represent different airflow regimes: skimming flow (SF), and wake interference (WI). It shows that the average Cp increases when B/H increases. For different air flow regimes, it is found that insignificant difference exists when the number of the building layers is more than 2. From the engineering point of view, it is sufficient to only include the first layer for natural ventilation design by using CFD simulation or wind tunnel experiment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Natural ventilation relies on less controllable natural forces so that it needs more artificial control, and thus its prediction, design and analysis become more important. This paper presents both theoretical and numerical simulations for predicting the natural ventilation flow in a two-zone building with multiple openings which is subjected to the combined natural forces. To our knowledge, this is the first analytical solutions obtained so far for a building with more than one zones and in each zone with possibly more than 2 openings. The analytical solution offers a possibility for validating a multi-zone airflow program. A computer program MIX is employed to conduct the numerical simulation. Good agreement is achieved. Different airflow modes are identified and some design recommendations are also provided.