998 resultados para Band characteristics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although physical activity is recommended in patients on maintenance hemodialysis (MHD), randomized controlled trials testing the effects of exercise in this population have given conflicting results. In general, aerobic exercises mostly failed to produce improvements in physical function, whereas resistance exercises, although less studied, appeared to be more promising. The use of sophisticated materials such as leg press and free weights may preclude widespread application of resistance training in patients on MHD. Simple and cheap elastic bands may thus be an attractive alternative. We tested the feasibility of a supervised intradialytic resistance band exercise training program, and its effects on physical function, in patients on MHD. A total of 11 unselected adult patients on MHD from our center, aged 70 ± 10.7 (mean ± standard deviation) years, including 8 men and 3 women, accepted to follow the program under the supervision of qualified physiotherapists. Thirty-six exercise sessions of moderate intensity (twice a week, mean duration 40 minutes each, during 4.5 to 6 months), mainly involving leg muscles against an elastic resistance, were performed. The exercise program was well tolerated and all patients completed it. Statistically significant improvements were observed in the following tests: Tinetti test, 23.9 ± 3.9 points before versus 25.7 ± 3.5 points after the program (P = .022); the Timed Up and Go test, 12.1 ± 6.6 versus 10 ± 5.8 seconds (P = .0156). Improvements in the 6-minute walk distance and in the one-leg balance tests just failed to reach statistical significance. In this single-center pilot study, an intradialytic resistance band exercise program was feasible, well tolerated, and showed encouraging results on physical function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report on a special investigation of the Clinton High School Band Boosters for the period August 1, 2014 through May 31, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data characteristics and species traits are expected to influence the accuracy with which species' distributions can be modeled and predicted. We compare 10 modeling techniques in terms of predictive power and sensitivity to location error, change in map resolution, and sample size, and assess whether some species traits can explain variation in model performance. We focused on 30 native tree species in Switzerland and used presence-only data to model current distribution, which we evaluated against independent presence-absence data. While there are important differences between the predictive performance of modeling methods, the variance in model performance is greater among species than among techniques. Within the range of data perturbations in this study, some extrinsic parameters of data affect model performance more than others: location error and sample size reduced performance of many techniques, whereas grain had little effect on most techniques. No technique can rescue species that are difficult to predict. The predictive power of species-distribution models can partly be predicted from a series of species characteristics and traits based on growth rate, elevational distribution range, and maximum elevation. Slow-growing species or species with narrow and specialized niches tend to be better modeled. The Swiss presence-only tree data produce models that are reliable enough to be useful in planning and management applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to assess the effects of the sward structure of Italian ryegrass (Lolium multiflorum), during the first grazing cycle, on its morphological and bromatological characteristics throughout the growing season, and on the performance of dairy cows. The treatments consisted of two structures obtained as a function of canopy-light interception: high-light interception (HLI) and low-light interception (LLI), with different pre-grazing heights in the first grazing cycle. Pasture was managed under rotational grazing with a herbage allowance not below 30 kg dry matter (DM) per cow per day. Three grazing cycles, with a grazing interval of 30 days, were evaluated. Pre-grazing herbage mass was greater (2,240 vs. 1,656 kg ha-1 DM), but the proportion of leaf blades was smaller (0.35 vs. 0.43) for HLI swards. Neutral detergent fiber (NDF) content and organic matter digestibility (OMD) were similar between treatments in the first grazing cycle, but in the second and third ones NDF was greater, and OMD lower, for the HLI swards. Milk yields were greater for cows grazing LLI swards (19.4 vs. 21.1 kg per day). Initial grazing with 90% of light interception promotes greater nutritional value in the subsequent cycles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a novel high capacity robust audio watermarking algorithm by using the high frequency band of the wavelet decomposition at which the human auditory system (HAS) is not very sensitive to alteration. The main idea is to divide the high frequency band into frames and, for embedding, to change the wavelet samples depending on the average of relevant frame¿s samples. The experimental results show that the method has a very high capacity (about 11,000 bps), without significant perceptual distortion (ODG in [¿1 ,0] and SNR about 30dB), and provides robustness against common audio signal processing such as additive noise, filtering, echo and MPEG compression (MP3).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Within the framework of the «Programme cantonal Diabète», we aimed at collecting data to 1) describe the population of diabetic patients in the canton of Vaud, and 2) assess the quality of their care. Methods: A cross-sectional study was conducted in the fall of 2011. Out of 140 randomly selected community pharmacies registered in the canton of Vaud, 56 accepted to participate in patients' recruitment. Noninstitutionalized adult diabetic patients (disease duration >12 months) visiting a pharmacy with a prescription for oral anti-diabetic drugs, insulin, glycemic strips or glucose meter were eligible. Patients not residing in the canton of Vaud, not speaking and understanding French well enough, presenting obvious cognitive impairment, and women with gestational diabetes, were excluded. Using a self-administered questionnaire, data was collected on patients' characteristics and diabetes as well as various process (e.g. recommended annual screenings) and outcomes quality of care indicators. Descriptive analyses were performed. Results: A total of 406 patients with diabetes participated. Mean age was 64 years, 41% were women and 63% were married. Patients reported type 1, 2 and other types of diabetes in 13%, 69% and 19%, respectively. They were treated with oral anti-diabetic drugs, insulin or both in 50%, 23% and 27% of the cases. Half of the patients did not report any diabetes-related complication. Glucose self-monitoring was reported by 82% of the patients. Of those who were aware of HbA1C (n = 218), 98% reported at least one HbA1C control during the last 12 months. During that same time frame, 97% and 95% reported at least one blood pressure and weight measure, 94% reported having had a cholesterol check, 74%, 68% and 64% had eyes, feet and urine screening respectively. 62% of the patients had been immunized against influenza. At least 76% of the patients had a minimum of 5 of the 7 described process indicators performed during the last 12 months. Among patients who knew the value (n = 145), mean HbA1C was 7.4 (SD 1.2). Conclusion: This study targeting community-based diabetic patients shows that while routine clinical and laboratory tests were annually performed in the vast majority of patients, feet and urine screening, as well as influenza immunization, were less often reported by patients. The proportion of patients with diabetes having had at least 5 out of the 7 annual screenings performed was nevertheless very high.