934 resultados para Azuki -- Storage.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study describes detailed partitioning of phytomass carbon (C) and soil organic carbon (SOC) for four study areas in discontinuous permafrost terrain, Northeast European Russia. The mean aboveground phytomass C storage is 0.7 kg C/m**2. Estimated landscape SOC storage in the four areas varies between 34.5 and 47.0 kg C/m**2 with LCC (land cover classification) upscaling and 32.5-49.0 kg C/m**2 with soil map upscaling. A nested upscaling approach using a Landsat thematic mapper land cover classification for the surrounding region provides estimates within 5 ± 5% of the local high-resolution estimates. Permafrost peat plateaus hold the majority of total and frozen SOC, especially in the more southern study areas. Burying of SOC through cryoturbation of O- or A-horizons contributes between 1% and 16% (mean 5%) of total landscape SOC. The effect of active layer deepening and thermokarst expansion on SOC remobilization is modeled for one of the four areas. The active layer thickness dynamics from 1980 to 2099 is modeled using a transient spatially distributed permafrost model and lateral expansion of peat plateau thermokarst lakes is simulated using geographic information system analyses. Active layer deepening is expected to increase the proportion of SOC affected by seasonal thawing from 29% to 58%. A lateral expansion of 30 m would increase the amount of SOC stored in thermokarst lakes/fens from 2% to 22% of all SOC. By the end of this century, active layer deepening will likely affect more SOC than thermokarst expansion, but the SOC stores vulnerable to thermokarst are less decomposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Geological storage of CO2 is nowadays internationally considered as the most effective method for greenhouse gas emission mitigation, in order to minimize its effects on the global climatology. One of the main options is to store the CO2 in deep saline aquifers at more than 800 m depth, because it achieves its supercritical state. Among the most important aspects concerning the performance assessment of a deep CO2 geological repository is the evaluation of the CO2 leakage rate from the chosen storage geological formation. Therefore, it is absolutely necessary to increase the knowledge on the interaction among CO2, storage and sealing formations, as well as on the flow paths for CO2 and the physico-mechanical resistance of the sealing formation. Furthermore, the quantification of the CO2 leakage rate is essential to evaluate its effects on the environment. One way to achieve this objective is to study of CO2 leakage on natural analogue systems, because they can provide useful information about the natural performance of the CO2, which can be applied to an artificial CO2 geological storage. This work is focused on the retention capacity of the cap-rock by measuring the diffuse soil CO2 flux in a site selected based on: i) the presence of a natural and deep CO2 accumulation; ii) its structural geological characteristics; and iii) the nature of the cap-rocks. This site is located in the so-called Mazarrón-Gañuelas Tertiary Basin, in the Guadalentin Valley, province of Murcia (Spain) Therefore the main objective of this investigation has been to detect the possible leakages of CO2 from a deep saline aquifer to the surface in order to understand the capability of this area as a natural analogue for Carbon Capture and Sequestration (CCS). The results obtained allow to conclude that the geological sealing formation of the basin seems to be appropriate to avoid CO2 leakages from the storage formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La pérdida de tensión por relajación en las armaduras activas afecta de forma importante a las estructuras de hormigón pretensado. Por ello se realizan ensayos de relajación de los alambres y cordones de pretensado tras su fabricación. Después, el material es enrollado y almacenado durante periodos que en ocasiones pueden superar el año de duración. Generalmente se desprecia la influencia que estas operaciones posteriores a la fabricación pueden tener sobre el material. Sin embargo, diversos fabricantes y suministradores han constatado experimentalmente que, en ocasiones, el material almacenado durante un periodo prolongado presenta pérdidas de relajación mayores que inmediatamente tras su fabricación. En este trabajo se realizan ensayos de laboratorio para comprobar la influencia que el radio de enrollamiento y el periodo de almacenamiento tienen sobre las pérdidas de relajación. También se propone un modelo analítico que permite predecir de manera razonablemente aproximada el valor del ensayo de relajación sobre un alambre sometido a un enrollamiento prolongado. Este modelo explica la evolución del perfil de tensiones durante el proceso de enrollamiento-almacenamiento-desenrollamiento, así como la influencia de las tensiones residuales

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arquitectura de almacenamiento para imágenes JPEG2000 basado en la fragmentación del fichero para poder almacenar los datos en diferentes discos para optimizar el almacenamiento en función de la calidad de los datos y posibilitar el aumento de transferencia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the rising prices of the retail electricity and the decreasing cost of the PV technology, grid parity with commercial electricity will soon become a reality in Europe. This fact, together with less attractive PV feed-in-tariffs in the near future and incentives to promote self-consumption suggest, that new operation modes for the PV Distributed Generation should be explored; differently from the traditional approach which is only based on maximizing the exported electricity to the grid. The smart metering is experiencing a growth in Europe and the United States but the possibilities of its use are still uncertain, in our system we propose their use to manage the storage and to allow the user to know their electrical power and energy balances. The ADSM has many benefits studied previously but also it has important challenges, in this paper we can observe and ADSM implementation example where we propose a solution to these challenges. In this paper we study the effects of the Active Demand-Side Management (ADSM) and storage systems in the amount of consumed local electrical energy. It has been developed on a prototype of a self-sufficient solar house called “MagicBox” equipped with grid connection, PV generation, lead–acid batteries, controllable appliances and smart metering. We carried out simulations for long-time experiments (yearly studies) and real measures for short and mid-time experiments (daily and weekly studies). Results show the relationship between the electricity flows and the storage capacity, which is not linear and becomes an important design criterion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 72 eggs from a group of 100 white laying hens housed in standard cages were analyzed. Thirty-six eggs were retired when the hens had 44 week of age and the other 36 eggs were retired eight weeks afterwards. Each group of 36 eggs was radomly divided in three groups of 12 eggs. First group was analyzed at once (storage system C); second one was kept during one week in the refrigerator (5ºC) (storage system R), and third group were kept also one week but on ambient temperature (25ºC) (storage system ET). The hen age, egg weight and storage system had not significant (P>0.05) effect on shell thickness. The specific gravity (SG) has a positive relation with shell quality. The egg class and storage system significantly (P<0,05) affected to SG, while no influence of bird age on this variable was observed. The yolk color increased with hen age but storage system had not effect on this variable. The increase of the hen age and the R and AT storage systems significantly (P<0.05) reduced albumen height (H) and the interaction hen age x storage system was significant (P<0.025) for this variable. The reduction of the H due to R and ET storage systems was higher in the eggs from hens with 52 weeks of age than in those from hens with 44 weeks of age. The Haugh units (HU) was significantly (P<0.05) affected by hen age, egg class and storage system. The hen age increase reduced HU and the R and ET eggs had lower HU than C eggs. It is concluded that the bird age and storage system with high temperatures reduced the egg quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 108 eggs from a group of 100 brown laying hens housed in standard cages were analyzed. Thirty-six eggs were retired when the hens had 30 week of age, other 36 eggs were retired when the hens had 35 week of age and the remaining 36 eggs were retired five weeks afterwards. Each group of 36 eggs was radomly divided in three groups of 12 eggs. First group was analyzed at once, second group one was kept during one week in the refrigerator (5°C) and third group was kept also one week but on ambient temperature (25°C). Shell color, shell thickness, specific gravity, albumen height and Haugh units wre obtained. The bird age had significant effect on shell color and shell thickness, but the storage system had not influence on such variables. The hen age had not effect on specific gravity, but the storage system affected to this variable. Hen age and storage system had significant influence (P<0.05) on albumen height and Haugh units, and the interaction age × storage system was significant for these variables. The specific gravity had positive relations with shell thickness, yolk color, albumen height and Haugh units. It is concluded that bird age and storage system under high temperatures reduced the egg quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Massive integration of renewable energy sources in electrical power systems of remote islands is a subject of current interest. The increasing cost of fossil fuels, transport costs to isolated sites and environmental concerns constitute a serious drawback to the use of conventional fossil fuel plants. In a weak electrical grid, as it is typical on an island, if a large amount of conventional generation is substituted by renewable energy sources, power system safety and stability can be compromised, in the case of large grid disturbances. In this work, a model for transient stability analysis of an isolated electrical grid exclusively fed from a combination of renewable energy sources has been studied. This new generation model will be installed in El Hierro Island, in Spain. Additionally, an operation strategy to coordinate the generation units (wind, hydro) is also established. Attention is given to the assessment of inertial energy and reactive current to guarantee power system stability against large disturbances. The effectiveness of the proposed strategy is shown by means of simulation results.