957 resultados para Antenna Arrays


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the design and the architecture of a bit-level systolic array processor. The bit-level systolic array described is directly applicable to a wide range of image processing operations where high performance and throughput are essential. The architecture is illustrated by describing the operation of the correlator and convolver chips which are being developed. The advantage of the system is also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel bit-level systolic array architecture for implementing IIR (infinite-impulse response) filter sections is presented. A first-order section achieves a latency of only two clock cycles by using a radix-2 redundant number representation, performing the recursive computation most significant digit first, and feeding back each digit of the result as soon as it is available. The design is extended to produce a building block from which second- and higher-order sections can be connected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dual-reflector antenna composed by a small reconfigurable reflectarray subreflector and a large parabolic main reflector is proposed for beam scanning application in the 120 GHz frequency band. The beam scanning is achieved by changing the phase distribution on the reflectarray surface which is supposed to contain reconfigurable cells. The phase distribution for the different beam deflecting states is obtained with a synthesis technique based on the analysis of the antenna in receive mode.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a hybrid scanning antenna architecture for applications in mm-wave intelligent mobile sensing and communications. We experimentally demonstrate suitable W-band leaky-wave antenna prototypes in substrate integrated waveguide (SIW) technology. Three SIW antennas have been designed that within a 6.5 % fractional bandwidth provide beam scanning over three adjacent angular sectors. Prototypes have been fabricated and their performance has been experimentally evaluated. The measured radiation patterns have shown three frequency scanning beams covering angles from 11 to 56 degrees with beamwidth of 10?±?3 degrees within the 88-94 GHz frequency range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A plethora of studies have described the in vitro assessment of dissolving microneedle (MN) arrays for enhanced transdermal drug delivery, utilising a wide variety of model membranes as a representation of the skin barrier. However, to date, no discussion has taken place with regard to the choice of model skin membrane and the impact this may have on the evaluation of MN performance. In this study, we have, for the first time, critically assessed the most common types of in vitro skin permeation models - a synthetic hydrophobic membrane (Silescol(®) of 75 µm) and neonatal porcine skin of definable thickness (300-350 µm and 700-750 µm) - for evaluating the performance of drug loaded dissolving poly (methyl vinyl ether co maleic acid) (PMVE/MA) MN arrays. It was found that the choice of in vitro skin model had a significant effect on the permeation of a wide range of small hydrophilic molecules released from dissolving MNs. For example, when Silescol(®) was used as the model membrane, the cumulative percentage permeation of methylene blue 24h after the application of dissolvable MNs was found to be only approximately 3.7% of the total methylene blue loaded into the MN device. In comparison, when dermatomed and full thickness neonatal porcine skin were used as a skin model, approximately 67.4% and 47.5% of methylene blue loaded into the MN device was delivered across the skin 24h after the application of MN arrays, respectively. The application of methylene blue loaded MN arrays in a rat model in vivo revealed that the extent of MN-mediated percutaneous delivery achieved was most similar to that predicted from the in vitro investigations employing dermatomed neonatal porcine skin (300-350 µm) as the model skin membrane. On the basis of these results, a wider discussion within the MN community will be necessary to standardise the experimental protocols used for the evaluation and comparison of MN devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Design and evaluation of a novel laser-based method for micromoulding of microneedle arrays from polymeric materials under ambient conditions. The aim of this study was to optimise polymeric composition and assess the performance of microneedle devices that possess different geometries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficacious delivery of antigens to antigen-presenting cells (APCs), in particular, to dendritic cells (DCs), and their subsequent activation remains a significant challenge in the development of effective vaccines. This study highlights the potential of dissolving microneedle (MN) arrays laden with nanoencapsulated antigen to increase vaccine immunogenicity by targeting antigen specifically to contiguous DC networks within the skin. Following in situ uptake, skin-resident DCs were able to deliver antigen-encapsulated poly-d,l-lactide-co-glycolide (PGLA) nanoparticles to cutaneous draining lymph nodes where they subsequently induced significant expansion of antigen-specific T cells. Moreover, we show that antigen-encapsulated nanoparticle vaccination via microneedles generated robust antigen-specific cellular immune responses in mice. This approach provided complete protection in vivo against both the development of antigen-expressing B16 melanoma tumors and a murine model of para-influenza, through the activation of antigen-specific cytotoxic CD8(+) T cells that resulted in efficient clearance of tumors and virus, respectively. In addition, we show promising findings that nanoencapsulation facilitates antigen retention into skin layers and provides antigen stability in microneedles. Therefore, the use of biodegradable polymeric nanoparticles for selective targeting of antigen to skin DC subsets through dissolvable MNs provides a promising technology for improved vaccination efficacy, compliance, and coverage.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a multifunctional microstrip antenna is designed, fabricated and experimentally verified for operation in AWS, GSM, WiMAX and WLAN bands. This microstrip patch antenna has two U-shaped slots to achieve the dual wideband operation required to meet these specifications. The dimensions and locations of the U-slots are designed appropriately. The thick substrate used here helps in integrating the antenna with the existing aircraft panel material while achieving wide bandwidths. Experimental results of this single feed antenna indicate that it meets all current requirements for in-cabin wireless communication needs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microstrip patch antennas are strong candidates for use in many wireless communications applications. This paper proposes the use of a patch antenna with two U-shaped slots to achieve dual band operation. A thick substrate helps broaden the individual bandwidths. The antenna is designed based on extensive IE3D simulation studies. A prototype antenna is fabricated and experimentally verified for the required performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Digital Video Broadcast Terrestrial (DVB-T) based passive radar requires the development of an antenna array that performs satisfactorily over the entire DVB-T band. The array should require no mechanical adjustments to inter-element spacing to correspond to the DVB-T carrier frequency used for any particular measurement. This paper will describe the challenges involved in designing an antenna array with a bandwidth of 450 MHz. It will discuss the design procedure and demonstrate a number of simulated array configurations. The final configuration of the array will be shown as well as simulations of the expected performance over the desired frequency span.