998 resultados para 989
Resumo:
BACKGROUND: Transient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique. METHODS: A 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner. RESULTS: The 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively). CONCLUSIONS: The 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period.
Resumo:
INTRODUCTION: The arteries of bifurcation aneurysms are sometimes so angulated or tortuous that an exchange maneuver is necessary to catheterize them with a balloon or stent delivery catheter. Because of the risk of distal wire perforation associated with exchange maneuvers, we sought to find an alternative technique. METHODS: Our experience shows that a microcatheter tends to preferentially follow a previously placed microcatheter, even if the initial catheterization might be challenging. Accessing an artery with two microcatheters simultaneously may thus be an alternative to an exchange maneuver. Because of this tendency for catheters to behave like sheep following one another, we named this method the sheeping technique (ST). The ST consists of (a) first placing a 1.7 French microcatheter into the division branch requiring balloon or stent protection to straighten the course of the arteries in order to facilitate and (b) positioning in the same artery of a larger and stiffer balloon or stent microcatheter. Once the second balloon or stent microcatheter is in place, the first microcatheter can be pulled back and used to coil the aneurysm. RESULTS: Between January 2009 and December 2012, The ST was successfully used in 208/246 procedures (85 %). Conversion to an exchange maneuver was necessary in 38/246 (15 %). There were no arterial perforations or ischemic events related to the handling of both microcatheters. CONCLUSION: The sheeping technique may improve safety by replacing the need for an exchange maneuver during difficult balloon- or stent-assisted coiling.
Resumo:
Even if only a small proportion of asylum seekers obtains a permanent resident permit, a significant number of them stay for a prolonged or indefinite period in Switzerland in a legal or illegal way. The asylum seekers can be either vectors or victims of infectious diseases. Some of these diseases can be prevented by vaccination. This article summarizes the recent decisions which have been taken in the canton Vaud concerning the vaccination of asylum seekers. These new recommendations privilege a large coverage of a maximum number of asylum seekers. Vaccinations against varicella and human papillomavirus will be proposed in addition to the already previously recommended vaccines. Finally the medical visits for the vaccinations will also be an opportunity to screen for chronic hepatitis B which has been neglected until now.
Resumo:
Ski resorts are deploying more and more systems of artificial snow. These tools are necessary to ensure an important economic activity for the high alpine valleys. However, artificial snow raises important environmental issues that can be reduced by an optimization of its production. This paper presents a software prototype based on artificial intelligence to help ski resorts better manage their snowpack. It combines on one hand a General Neural Network for the analysis of the snow cover and the spatial prediction, with on the other hand a multiagent simulation of skiers for the analysis of the spatial impact of ski practice. The prototype has been tested on the ski resort of Verbier (Switzerland).
Resumo:
The activation of an apo-cytochrome c-specific T cell clone was found to differ, depending on the antigen-presenting cell population. Whereas total syngeneic spleen cells and bone marrow macrophages could be shown to trigger proliferation, IL 2, and MAF production by the T cell clone, a B cell lymphoma only induced MAF secretion. Further studies demonstrated that this effect was not due to a different antigen processing by the B lymphoma or to limiting amounts of Ia and antigen molecules on the B lymphoma cell surface. The dissociation of induction of MAF production from IL-2 production/proliferation found with the different antigen-presenting cells indicates strongly that molecules other than Ia and antigen may be required for the complete functional activation of antigen-specific T cell clones.
Resumo:
Retrospective single institution analysis of all patients undergoing sleeve lobectomy or pneumonectomy between 2000 and 2005. Seventy-eight patients underwent pneumonectomy (65 patients <70 years, 13 patients >70 years) and 69 sleeve lobectomy (50 patients <70 years, 19 patients >70 years). Pre-existing co-morbidity, surgical indication and induction therapy was similarly distributed between treatment by age-groups. In patients <70 years, pneumonectomy and sleeve lobectomy resulted in a 30-day mortality of 3% vs. 0 and an overall complication rate of 26% vs. 44%, respectively. In patients >70 years, pneumonectomy and sleeve lobectomy resulted in a 30-day mortality of 15% vs. 0 and an overall complication rate of 23% vs. 32%. In both age groups, pneumonectomy was associated with more airway complications (NS) and a significantly higher postoperative loss of FEV(1) than sleeve lobectomy (P<0.0001, P<0.03). Age per se did not influence the loss of FEV(1) and DLCO for a given type of resection. Sleeve lobectomy may have a therapeutic advantage over pneumonectomy in the postoperative course of elderly patients.
Resumo:
The original cefepime product was withdrawn from the Swiss market in January 2007, and replaced by a generic 10 months later. The goals of the study were to assess the impact of this cefepime shortage on the use and costs of alternative broad-spectrum antibiotics, on antibiotic policy, and on resistance of Pseudomonas aeruginosa towards carbapenems, ceftazidime and piperacillin-tazobactam. A generalized regression-based interrupted time series model assessed how much the shortage changed the monthly use and costs of cefepime and of selected alternative broad-spectrum antibiotics (ceftazidime, imipenem-cilastatin, meropenem, piperacillin-tazobactam) in 15 Swiss acute care hospitals from January 2005 to December 2008. Resistance of P. aeruginosa was compared before and after the cefepime shortage. There was a statistically significant increase in the consumption of piperacillin-tazobactam in hospitals with definitive interruption of cefepime supply, and of meropenem in hospitals with transient interruption of cefepime supply. Consumption of each alternative antibiotic tended to increase during the cefepime shortage and to decrease when the cefepime generic was released. These shifts were associated with significantly higher overall costs. There was no significant change in hospitals with uninterrupted cefepime supply. The alternative antibiotics for which an increase in consumption showed the strongest association with a progression of resistance were the carbapenems. The use of alternative antibiotics after cefepime withdrawal was associated with a significant increase in piperacillin-tazobactam and meropenem use and in overall costs, and with a decrease in susceptibility of P. aeruginosa in hospitals. This warrants caution with regard to shortages and withdrawals of antibiotics.
Resumo:
AIMS: To evaluate short-term clinical outcomes following transcatheter aortic valve implantation (TAVI) using CE-mark approved devices in Switzerland. METHODS AND RESULTS: The Swiss TAVI registry is a national, prospective, multicentre, monitored cohort study evaluating clinical outcomes in consecutive patients undergoing TAVI at cardiovascular centres in Switzerland. From February 2011 to March 2013, a total of 697 patients underwent TAVI for native aortic valve stenosis (98.1%), degenerative aortic bioprosthesis (1.6%) or severe aortic regurgitation (0.3%). Patients were elderly (82.4±6 years), 52% were females, and the majority highly symptomatic (73.1% NYHA III/IV). Patients with severe aortic stenosis (mean gradient 44.8±17 mmHg, aortic valve area 0.7±0.3 cm²) were either deemed inoperable or at high risk for conventional surgery (STS 8.2%±7). The transfemoral access was the most frequently used (79.1%), followed by transapical (18.1%), direct aortic (1.7%) and subclavian access (1.1%). At 30 days, rates of all-cause mortality, cerebrovascular events and myocardial infarction were 4.8%, 3.3% and 0.4%, respectively. The most frequently observed adverse events were access-related complications (11.8%), permanent pacemaker implantation (20.5%) and bleeding complications (16.6%). The Swiss TAVI registry is registered at ClinicalTrials.gov (NCT01368250). CONCLUSIONS: The Swiss TAVI registry is a national cohort study evaluating consecutive TAVI procedures in Switzerland. This first outcome report provides favourable short-term clinical outcomes in unselected TAVI patients.