992 resultados para 1059
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Purpose: This study aimed to investigate the influence of ceramic thickness and shade on the Knoop hardness and dynamic elastic modulus of a dual-cured resin cement.Materials and Methods: Six ceramic shades (Bleaching, A1, A2, A3, A3.5, B3) and two ceramic thicknesses (1 mm, 3 mm) were evaluated. Disk specimens (diameter: 7 mm; thickness: 2 mm) of the resin cement were light cured under a ceramic block. Light-cured specimens without the ceramic block at distances of 1 and 3mm were also produced. The Knoop hardness number (KHN), density, and dynamic Young's moduli were determined. Statistical analysis was conducted using ANOVA and a Tukey B rank order test (p = 0.05).Results: The bleaching 1-mm-thick group exhibited significantly higher dynamic Young's modulus. Lower dynamic Young's moduli were observed for the 3-mm-thick ceramic groups compared to bleaching 3-mm-thick group, and no difference was found among the other 3-mm groups. For the KHN, when A3.5 3-mm-thick was used, the KHN was significantly lower than bleaching and A1 1-mm-thick ceramic; however, no difference was exhibited between the thicknesses of the same shade.Conclusions: The dual-cured resin cement studied irradiated through the 1-mm-thick ceramic with the lightest shade (bleaching ceramic) exhibited a better elastic modulus, and there was no effect in KHN of the resin cement when light cured under different ceramic shades and thicknesses (1 and 3 mm), except when the A3.5 3-mm-thick ceramic was used.Clinical Significance: Variolink II irradiated through ceramic with the lowest chroma exhibited the highest elastic modulus; therefore, the light activation method might not be the same for all clinical situations.
Resumo:
PurposeThe mechanical properties of acrylic resins used in intraoral prostheses may be altered by frequent exposure to liquids such as beverages and mouthwashes. This study aimed to evaluate the effect of thermocycling and liquid immersion on the hardness of four brands of acrylic resins commonly used in removable prostheses (Onda Cryl, QC-20, Classico, Lucitone).Materials and MethodsFor each brand of resin, seven specimens were immersed in each of six solutions (coffee, cola, red wine, Plax-Colgate, Listerine [LI], Oral B), and seven more were placed in artificial saliva (control). The hardness was tested using a microhardness tester before and after 5000 thermocycles and after 1, 3, 24, 48, and 96 hours of immersion. The results were analyzed using three-way repeated-measures ANOVA and Tukey's test (p < 0.05).ResultsThe hardness of the resins decreased following thermocycling and immersion in the solutions. Specimens immersed in cola and wine exhibited significant decreases in hardness after immersion for 96 hours, although the greatest significant decrease in hardness occurred in specimens immersed in LI. However, according to American Dental Association specification 12, the Knoop hardness of acrylic resins for intraoral prostheses should not be below 15. Thus, the median values of superficial hardness observed in most of the acrylic resins in this study are considered clinically acceptable.ConclusionsThe microhardness of polymers used for intraoral prostheses decreases following thermocycling. Among specimens immersed in beverages, those immersed in cola or wine experienced the greatest decrease in microhardness. Immersion of acrylic resins in LI significantly decreased the microhardness in relation to the initial value. Among the resins assessed, QC-20 exhibited the lowest initial hardness.
Resumo:
The CAD/CAM technology associated with rapid prototyping (RP) is already widely used in the fabrication of all-ceramic fixed prostheses and in the biomedical area; however, the use of this technology for the manufacture of metal frames for removable dentures is new. This work reports the results of a literature review conducted on the use of CAD/CAM and RP in the manufacture of removable partial dentures.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: Temporomandibular disorders (TMD) are recognized as one of the mostcontroversial topics in dentistry, despite the fact that both basic science and clinicalresearchers have currently reached some degree of consensus. This study aimed toconduct a questionnaire-based survey about the management of TMD patients bygeneral dental practitioners (GDPs).Materials and Methods: One hundred fifty-one GDPs with a private practice in a cityof southern Brazil were included, independent of school of origin, gender, graduationyear, and curriculum content. All participants were administered a questionnaire aboutthe management of patients with TMD, and the responses were analyzed by binomialand chi-square tests (α = 0.05).Results: Of the GDPs, 88.7% received TMD patients, who were primarily diagnosedon the basis of medical history (36.6%) or physical examination (30.4%). Of these,65.4% referred the patients elsewhere, primarily to specialists in occlusion (36.1%) ororthodontics (29.7%). Occlusal splinting was the most commonly used managementmodality (20.8%), followed by occlusal adjustment (18.1%) and pharmacotherapy(16.6%). Splints were fabricated in maximum habitual intercuspation or centric re-lation depending on individual patient (54.8%). The hard stabilization form was themost common type of appliance used (35.0%). Moreover, 73.8% of the GDPs didnot employ semi-adjustable articulators, and 69.5% adjusted the appliances at thetime of fixing. The duration of splint use and the frequency of follow-up were con-sidered patient dependent by 62.1% and 72.8%, respectively. GDPs considered thetwo major TMD etiologic categories as multifactorial (20.8%) and occlusion (19.9%).Multidisciplinary medical and dental treatment was considered necessary by 97.9%.Conclusions: The evaluated general dental practitioners manage TMD patients ac-cording to international guidelines.
Resumo:
Purpose: The objective of this article is to describe a method to construct an intraoralacrylic device that permits a reline material to be added to the inner surface of thepalatal plate.Materials and Methods: Fifteen 60-day-old adult female rats (Rattus NorvegicusAlbinus Wistar), weighing 150 to 250 g were used for this study and allocated to threegroups (n = 5): G1, animals wearing a heat-polymerized acrylic resin palatal plate(Lucitone 550) for 14 days; G2, animals wearing a heat-polymerized acrylic resinpalatal plate (Lucitone 550) relined with Tokuyama Rebase II for 14 days; and G3,animals maintained under the same conditions as the experimental groups, withoutwearing palatal plates for 14 days. The manipulation of the animals followed theguidelines of the Brazilian College of Animal Experimentation, under the approval ofthe animal ethics committee of the State University of Ponta Grossa. The palatal platescovered the whole palate, were fixed in the molar region with light-cured resin, andwere kept there for 14 days. The animals received a paste diet and water ad libitum.Before and after the trial period, the rats were weighed individually on a precisionscale. Statistical analysis was performed using a two-way analysis of variance (α =0.05) test for comparison of the animals’ weight (g) at time 0 and after 14 days ofusing the palatal plate.Results: No statistical differences were observed regarding the weight of the animalsamong the experimental groups in the study.Conclusions: The individual master impressions, the molar teeth coverage, and themethod of cementation with nonadhesive composite resin provided good stability forthe palatal plate showed in this study, not disturbing the eating habits and nutritionof the animals. This model seems reproducible, offering adequate histopathologicalevaluation. Differences in tissue morphology exist between the animals that used thepalatal plate and the animals that did not use this device. Use of these palatal platescould clarify how prostheses bring changes in the palatal mucosa of users.
Resumo:
The objective of this study is to report the clinical use of 2% Uncaria tomentosa gel against denture stomatitis (DS) as an alternative treatment. The patient was a 65-year-old, denture-wearing woman. At the clinical examination, her palate showed hyperplasic and erythematous mucosa indicating DS type II. DS is a chronic oral disease that affects denture wearers. It occurs as an inflammatory reaction in denture-wearing patients under maxillary prostheses. Candida albicans has been reported as the principal etiological agent. An alternative treatment, the topical application of a gel of 2% U. tomentosa three times a day for 1 week was given to the patient. After 1 week of this treatment, she had significantly reduced signs of the disease. Despite the existence of a great number of antifungal agents, treatment failure is observed frequently. Phytotherapy is becoming more popular worldwide. Currently, the most promising medicinal Amazonian herb is U. tomentosa (Willd.) DC., known as Cat's Claw. Studies of the chemical and pharmacological properties of this medicinal plant have allowed researchers to develop indications for its use. This report demonstrates the effectiveness of U. tomentosa against DS.
Resumo:
The aim of this study was to evaluate the presence of residues of sodium hypo-chlorite gel, chlorhexidine gel, and EDTA gel on dentina l walls after canal preparat ion throughchemical SEM- elemental chemical microanal ys is (EDS) analysis. Forty-eight single-rootedteeth were selected. They had their crowns sectioned and were instrumented with a reciprocat-ing system. The canals were irrigated with 5 mL of saline solution during root canal preparation.After instrumentation, the root canals were irrigated with 3 mL 17% EDTA followed by 1 min ofultrasonic passive activation (33 20 sec) to remove the smear layer, and then irrigated with3 mL of saline solution. The specimens were randomized into three groups (n 5 12) accord ing tothe chemical substance that filled the root canal for 30 min: GI: 5.5% sodium hypochlorite gel;GII: 2% chlorhexidine gel; GIII: 24% EDTA gel; Negative c ontrol group: no substance was used.Then, the root canals were irrigated with 6 mL of saline solution followed by 1 min of ultrasonicpassive activation (33 20 sec). After ultrasonic activation , the canals were irrigated with 2 mLsaline. The roots were sect ioned, and the perce ntage of each chemical element present in thesamples was analyzed through chemi cal SEM-EDS microanalysis. All expe rimental groupsshowed a significantly higher percentage of chemical elements (Na and/or Cl) than the controlgroup (P < 0.03). This in vitro study has shown that, regardless of chemical solutions used evenafter the final irrigation protocol, chemical residues of d ifferent substances remained attached tothe r oot c anal wa lls. Microsc. Res. Tech. 78:495–49 9, 2015.
Resumo:
This study evaluated the influence of finishing and polishing procedures and differ-ent fluoride solutions on superficial morphology and chemistry of the nanofilled composite resinSupreme XT (3M) through the EDX analysis and SEM evaluation. Circular specimens (n 5 30) of 10mm diameter and 2 mm thickness were prepared, with half of the sample assays finished and polishedwith Super-Snap1sandpaper. The experimental groups were divided according to the presence or ab-sence of finishing and polishing and solutions (arti ficial saliva, 0.0 5% of manipulated sodium fluoridesolution, Fluordent Re ach, Oral B, Fluorgard). Specimens were immersed in each respective solutionfor 1 min per day, during 60 days and stored in artificial saliva at 37 6 18C between immersion peri-ods. Topography and chemical analysis was qualitative. It was observed that specimens submitted tofinishing and polishing procedures had lower superficial degradation. Fluoride solutio ns promoted su-perficial alterations on specimens, being the highest degradation obtained with Fluordent Reach. Itca n be concluded that finishing and polishing procedures and the immersion media influence the su-perficial morphology of composite resin tested; the Fluordent Reach was the flu oride solution thatmo st affected the material’s surface.
Resumo:
Composite resin is a dental material susceptible to color change over time which limits the longevity of restorations made with this material. The influence of light curing units and different fluoride mouthrinses on superficial morphology and color stability of a nanofilled composite resin was evaluated. Specimens (N = 150) were prepared and polished. The experimental groups were divided according to the type of light source (halogen and LED) and immersion media (artificial saliva, 0.05% sodium fluoride solution-manipulated, Fluordent Reach, Oral B, Fluorgard). Specimens remained in artificial saliva for 24-h baseline. For 60 days, they were immersed in solutions for 1 min. Color readout was taken at baseline and after 60 days of immersion. Surface morphology was analyzed by Scanning Electron Microscopy (SEM) after 60 days of immersion. Color change data were submitted to two-way Analysis of Variance and Tukey tests (α = 0.05). Surface morphology was qualitatively analyzed. The factor light source presented no significant variability (P = 0.281), the immersion media, significant variability (P < 0.001) and interaction between factors, no significant variability (P = 0.050). According to SEM observations, no difference was noted in the surface of the specimens polymerized by different light sources, irrespective of the immersion medium. It was concluded that the light source did not influence the color stability of composite, irrespective of the immersion media, and among the fluoride solutions analyzed, Fluorgard was the one that promoted the greatest color change, however, this was not clinically perceptible. The immersion media did not influence the morphology of the studied resin. Microsc. Res. Tech. 77:941–946, 2014. © 2014 Wiley Periodicals, Inc.
Resumo:
The aim of this study was to evaluate the effects of different power parameters of an Erbium, Cromium: Yttrium, Scandium, Gallium, Garnet laser (Er,Cr:YSGG laser) on the morphology, attachment of blood components (ABC), roughness, and wear on irradiated root surfaces. Sixty-five incisive bovine teeth were used in this study, 35 of which were used for the analysis of root surface morphology and ABC. The remaining 30 teeth were used for roughness and root wear analysis. The samples were randomly allocated into seven groups: G1: Er,Cr:YSGG laser, 0.5 W; G2: Er,Cr:YSGG laser, 1.0 W; G3: Er,Cr:YSGG laser, 1.5 W; G4: Er,Cr:YSGG laser, 2.0 W; G5: Er,Cr:YSGG laser, 2.5 W; G6: Er,Cr:YSGG laser, 3.0 W; G7: scaling and root planning (SRP) with manual curettes. The root surfaces irradiated by Er,Cr:YSGG at 1.0 W and scaling with manual curettes presented the highest degrees of ABC. The samples irradiated by the Er,Cr:YSGG laser were rougher than the samples treated by the manual curette, and increasing the laser power parameters caused more root wear and greater roughness on the root surface. The Er,Cr:YSGG laser is safe to use for periodontal treatment, but it is not appropriate to use irradiation greater than 1.0 W for this purpose. Microsc. Res. Tech. 78:529–535, 2015. © 2015 Wiley Periodicals, Inc.
Resumo:
Cisplatin (CPL) is one of the most widely used and effective chemotherapeutic agents for the treatment of several human malignancies. However, it causes serious side effects, especially on reproduction. In order to reduce the undesirable effects caused by many drugs, liposomes have been used as a good system for drug delivery. The aim of this study was to investigate, for the first time, the effects of CPL incorporated into the dipalmitoyl phosphatidylcholine liposome (DPPC) on the testicular tissue of adult Wistar rats. The animals (n = 20) were distributed into four experimental groups: (a) control (distillated water); (b) liposome (DPPC, 1 mL), (c) cisplatin incorporated into liposome (CPL/DPPC), and (d) CPL (8 mg/kg body weight). The animals received a single intraperitoneal injection and were killed 10 days after each treatment for histopathological analysis of testes. The results showed that the testicular histomorphometric parameters in rats of DPPC and CPL/DPPC groups were similar to those of the control group. Meanwhile, rats of the CPL-treated group showed a variety of morphological alterations, including atrophy of seminiferous tubules and presence of multinucleated cells in the germinal epithelium. The incorporation of CPL into the liposome had no influence on the testicular weight or any other stereological parameters, but it was beneficial in maintaining the body weight of the animals. In conclusion, the liposome suppressed the cytotoxic effects caused by cisplatin in the testes of rats, suggesting a possible use in chemotherapy against cancer to reduce the side effects seen on reproduction.
Resumo:
Purpose: The aim of this systematic review was to compare straight-line and offset implant configurations for three-element implant-retained prostheses. Materials and Methods: Two independent reviewers conducted a review on PubMed/Medline, EMBASE, and Cochrane Library for studies published in English, from January 1, 1995 to January 17, 2014. A systematic review was conducted following the PRISMA statement. All relevant titles were selected according to inclusion/exclusion criteria. From this pool of titles, abstracts and full texts were reviewed. Results: A total of 6080 titles were identified with the initial search. Twenty-one were selected based on title and abstract. Of these, after discussion and complete reading, 12 studies were selected according to the inclusion and exclusion criteria, all of which were in vitro studies. Conclusions: A systematic review of the current literature showed only in vitro evidence that there is no consensus on the advantage of using an offset configuration implant compared to those in straight-line configuration, even though some studies present a slight improvement of bone stress distribution when an offset implant is under oblique loading (PICO).