968 resultados para 10-(Octyloxy) decyl-2-(trimethylammonium)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low level laser therapy (LLLT) is known for its positive results but studies on the biological and biomodulator characteristics of the effects produced in the skeletal muscle are Still lacking. In this Study the effects of two laser dosages, 5 or 10 J/cm(2), on the lesioned tibial muscle were compared. Gerbils previously lesioned by 100 g load impact were divided into three groups: GI (n = 5) controls, lesion non-irradiated; GII (n = 5), lesion irradiated with 5 J/Cm(2) and GIII (n = 5), lesion irradiated with 10 J/cm(2), and treated for 7 consecutive days with a laser He-Ne (lambda = 633 rim). After intracardiac perfusion, the muscles were dissected and reduced to small fragments, post-fixed in 1% osmium tetroxide, dehydrated in increasing alcohol concentrations, treated with propylene oxide and embedded in Spurr resin at 60 degrees C. Ultrafine Cuts examined on a transmission electron microscope (Jeol 1010) revealed in the control GI group a large number of altered Muscle fibers with degenerating mitochondria, intercellular substance containing degenerating cell fragments and budding blood capillaries with Underdeveloped endothelial cells. However, groups GII and GIII showed muscle fibers with few altered myofibrils, regularly contoured mitochondria, ample intermembrane spaces and dilated mitochondrial crests. The clean intercellular Substance showed numerous collagen fibers and capillaries with multiple abluminal processes, intraluminal protrusions and several pinocytic vesicles in endothelial cells. it was concluded that laser dosages of 5 or 10 J/cm(2) delivered by laser He-Ne (lambda = 633 rim) during 7 consecutive days increase mitochondrial activity in muscular fibers, activate fibroblasts and macrophages and stimulate angiogenesis, thus suggesting effectivity of laser therapy tinder these experimental conditions. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent results from our laboratory have shown that 30-bites social conflict in mice produces a high-intensity, short-term analgesia which is attenuated by systemically injected 5-HT1A receptor agonists, such as BAY R 1531 (6-methoxy-4-(di-n-propylamino)-1,3,4,5-tetrahydrobenz(c,d)indole hydrochloride) and gepirone. The present study investigated the effects of these drugs, as well as the 5-HT1A receptor antagonist WAY 100135 (N-tert-butyl-3-(4-(2-methoxyphenyl)piperazine-1-yl)-2-phenylpropanamide) injected into the midbrain periaqueductal gray matter of mice on 30-bites analgesia. Four to five days after guide-cannula implantation, each mouse received microinjection of gepirone (30 nmol/0.2 mu l), BAY R 1531 (10 nmol/0.2 mu l), WAY 100135 (10 nmol/0.2 mu l), saline (0.9% NaCl) or vehicle (saline + 4% Tween 80) 5 min before either an aggressive (30 bites) or a non-aggressive interaction. Nociception was assessed by the tail-flick test made before as well as 1, 5, 10 and 20 min after social interaction. The full 5-HT1A receptor agonist BAY R 1531 blocked, whereas, WAY 100135 and gepirone intensified 30-bites analgesia, Neither non-aggressive interaction, per se, nor the three compounds given after this type of social interaction significantly changed nociception. These results indicate that 5-HT1A receptors in the periaqueductal gray inhibit analgesia induced by social conflict in mice. (C) 1998 Elsevier B.V. B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the wound healing activity of a glycolic extract of Dillenia indica (GED) prepared from the mature fruits of the plant applied alone or in combination with microcurrent stimulation to skin wounds surgically induced on the back of Wistar rats. Methods. The animals were randomly divided into six groups: (A) negative control group; (B) group receiving microcurrent application (MC; [10 mu A/2 mins]); (C) group treated with GED; (D) group treated with an emulsion containing GED; (E) group treated with GED and MC, and (F) group treated with the emulsion containing GED and MC. Tissue samples were obtained 2, 6, and 10 days after injury and underwent structural and morphometric analysis, Results. There were observed differences in wound healing among the various treatments when compared to the control group. The combination of microcurrent plus extract or microcurrent plus emulsion containing GED was advantageous in all of the studied parameters (P < 0.05) when compared to the other groups with positive effects seen regarding newly formed tissue, number of fibroblasts, and number of newly formed blood vessels. The morphometric data confirmed the structural findings. Conclusion. Microcurrent application alone or combined with GED exerted significant effects on wound healing in this experimental model. This was probably due to the efficacy of microcurrent application since the extract alone did not significantly accelerate the healing process. D indica fruit extract most likely participates in the wound healing process as a result of its anti-inflammatory properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Injection-limited operation is identified in thin-film, alpha-NPD-based diodes. A detailed model for the impedance of the injection process is provided which considers the kinetics of filling/releasing of interface states as the key factor behind the injection mechanism. The injection model is able to simultaneously account for the steady-state, current-voltage (J-V) characteristics and impedance response. and is based on the sequential injection of holes mediated by energetically distributed surface states at the metal-organic interface. The model takes into account the vacuum level offset caused by the interface dipole, along with the partial shift of the interface level distribution with bias voltage. This approach connects the low-frequency (similar to 1 Hz) capacitance spectra, which exhibits a transition between positive to negative values, to the change in the occupancy of interface states with voltage. Simulations based on the model allow to derive the density of interface states effectively intervening in the carrier injection (similar to 5 x 10(12) cm(-2)), which exhibit a Gaussian-like distribution. A kinetically determined hole barrier is calculated at levels located similar to 0.4 eV below the contact work function. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capacitance spectra of thin (< 200 nm) Alq(3) electron-only devices have been measured as a function of bias voltage. Capacitance spectra exhibit a flat response at high frequencies (> 10(3) Hz) and no feature related to the carrier transit time is observed. Toward low frequencies the spectra reach a maximum and develop a negative excess capacitance. Capacitance response along with current-voltage (J-V) characteristics are interpreted in terms of the injection of electrons mediated by surface states at the metal organic interface. A detailed model for the impedance of the injection process is provided that highlights the role of the filling/releasing kinetics of energetically distributed interface states. This approach connects the whole capacitance spectra to the occupancy of interface states, with no additional information about bulk trap levels. Simulations based on the model allow to derive the density of interface states effectively intervening in the carrier injection (similar to 1.5 x 10(12) cm (2)). (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive flow-injection (FI) procedure with spectrophotometric detection in a micellar medium is proposed for the determination of novalgin. The method is based on the instantaneous formation of a red-orange product (lambda(max) = 510 nm) after the reaction between novalgin and p-dimethylaminocinnamaldehyde (p-DAC) in a dilute acid medium. The sensitivity of this reaction was increased by a factor of 5.6 in the presence of sodium dodecyl sulfate (SDS). Experimental design methodologies were used to optimize the chemical and FI variables. The calibration curve was linear in the range of 1.45 x 10(-6) to 2.90 x 10(-5) mol L-1 with an excellent correlation coefficient (r = 0.9999). The detection limit was 1.31 x 10(-7) mol L-1 (n = 20, RSD = 2.0%). No interferences were observed from the common excipients. The results obtained by the proposed method were favorably compared with those given by the iodometric reference method at 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surfaces of silicon wafers implanted with N and C, respectively, and aluminum 5052 implanted with N alone by plasma immersion ion implantation WHO were probed by a nanoindentor and analyzed by the contact-angle method to provide information on surface nanohardness and wettability. Silicon nitride and silicon carbide are important ceramic materials for microelectronics, especially for high-temperature applications. These compounds can be synthesized by high-dose ion implantation. The nanohardness of a silicon sample implanted with 12-keV nitrogen PIII (with 3 X 10(17) cm(-2) dose) increased by 10% compared to the unimplanted sample, in layers deeper than the regions where the formation of the Si,N, compound occurred. A factor of 2.5 increase in hardness was obtained for C-implanted Si wafer at 35 keV (with 6 X 10(17) cm(-2) dose), again deeper than the SiC-rich layer, Both compounds are in the amorphous state and their hardness is much lower than that of the crystalline compounds, which require an annealing process after ion implantation. In the same targets, the contact angle increased by 65% and 35% for N- and C-implanted samples, respectively. Compared to the Si target, the nitrogen PIII-irradiated Al 5052 (wish 15 keV) showed negligible change in its hydrophobic character after ion implantation. Its near-surface nanohardness measurement showed a slight increase for doses of 1 X 10(17) cm(-2). We have been searching for an AlN layer of the order of 1000 A thick, using such a low-energy PIII process, but oxide formation during processing has precluded its synthesis. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The non-ohmic and dielectric properties as well as the dependence on the microstructural features of CaCu(3)Ti(4)O(12)/CaTiO(3) ceramic composites obtained by conventional and microwave sintering were investigated. It was demonstrated that the non-ohmic and dielectric properties depend strongly on the sintering conditions. It was found that the non-linear coefficient reaches values of 65 for microwave-sintered samples and 42 for samples sintered in a conventional furnace when a current density interval of 1-10 mA cm(-2) is considered. The non-linear coefficient value of 65 is equivalent to 1500 for samples sintered in the microwave if a current interval of 5-30 mA is considered as is shortly discussed by Chung et al (2004 Nature Mater. 3 774). Due to a high non-linear coefficient and a low leakage current (90 mu A) under both processing conditions, these samples are promising for varistor applications. The conventionally sintered samples exhibit a higher relative dielectric constant at 1 kHz (2960) compared with the samples sintered in the microwave furnace (2100). At high frequencies, the dielectric constant is also larger in the samples sintered in the conventional furnace. Depending on the application, one or another synthesis methodology is recommended, that is, for varistor applications sintered in a microwave furnace and for dielectric application sintered in a conventional furnace.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to analyze variability, linear and spatial correlations of forage dry mass yield (FDM) and dry matter percentage (DM%) of Brachiaria decumbens with the bulk density (BD), gravimetric (GM) and volumetric (VM) moisture, mechanical resistance to penetration (RP) and organic matter content (OM), at depths 1 (0-0.10 m) and 2 (0.10-0.20 m), in a Red Latosol (Oxisol), in order to select an indicator of soil physical quality and identify possible causes of pasture degradation. The geostatistical grid was installed to collect soil and plant data, with 121 sampling points, over an area of 2.56 ha. The linear correlation between FDM × DM% and FDM × BD2 was low, but highly significant. Spatial correlations varied inversely and positively, respectively. Except for DM% and BD, at both depths, the other attributes showed average to high variability, indicating a heterogeneous environment. Thus, geostatistics emerges as an important tool in understanding the interactions in pasture ecosystems, in order to minimize possible causes of degradation and indicate better alternatives for soil-plant-animal management. The decrease in FDM and increased BD1 are indicators of physical degradation (compaction) of Red Latosol (Oxisol), particularly in the places with the highest concentration of animals and excessive trampling, in Cerrado conditions, in the municipality of Selvíria, Mato Grosso do Sul State, Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Não existem estudos que relatem as repercussões renais determinadas pela injeção de doses elevadas de clonidina no espaço peridural. O objetivo do estudo foi avaliar os efeitos hemodinâmicos e renais determinados pela injeção de doses elevadas de clonidina no espaço peridural do cão. MÉTODO: Vinte animais anestesiados com tiopental sódico e fentanil foram distribuídos aleatoriamente e de forma duplamente encoberta em dois grupos: Grupo 1 ou placebo (n = 10), que recebeu 0,2 mL.kg-1 de solução fisiológica, e Grupo 2 ou clonidina (n = 10), que recebeu 0,2 mL.kg-1 de uma solução contendo 50 µg.mL-1 de clonidina, no espaço peridural. Foram avaliados os seguintes parâmetros hemodinâmicos: freqüência cardíaca (FC): bat.min-1; pressão arterial média (PAM): mmHg; pressão da artéria pulmonar ocluida (PAOP): mmHg; débito cardíaco (DC): L.min-1; volume sistólico (VS): mL; também, os seguintes parâmetros da função renal foram avaliados: fluxo sangüíneo renal (FSR): mL.min-1; resistência vascular renal (RVR): mmHg.mL-1.min; volume urinário minuto (VUM): mL.min-1; depuração de creatinina (D Cr): mL.min-1; depuração de para-aminohipurato (D PAH): mL.min-1; fração de filtração (FF); depuração de sódio (D Na): mL.min-1; depuração de potássio (D K): mL.min-1; excreção fracionária de sódio (EF Na): %; excreção urinária de sódio (U NaV): µEq.min-1; excreção urinária de potássio (U K V): µEq.min-1. O experimento consistiu em três momentos de 20 minutos cada. Os dados foram coletados aos 10 minutos de cada momento e a diurese, no início e no final de cada momento. Ao término de M1, a clonidina ou a solução fisiológica foi administrada no espaço peridural. Após período de 20 minutos iniciou-se M2 e, em seguida, M3. RESULTADOS: A clonidina na dose de 10 µg.kg-1 no espaço peridural do cão promoveu alterações significativas, com diminuições da freqüência cardíaca e do débito cardíaco e aumento da relação depuração de para-aminohipurato de sódio/débito cardíaco. CONCLUSÕES: Nas condições realizadas e nas doses empregadas, pode-se concluir que a clonidina não promoveu alteração da função renal, mas diminuiu valores hemodinâmicos (freqüência e débito cardíaco).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)