988 resultados para tungsten trioxide


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate and compare the repair of bone defects filled with calcium aluminate cement (EndoBinder), mineral trioxide aggregate (MTA), and calcium hydroxide. Methods After mixing, the cements were inserted into bone defects (3.3 mm) mechanically created in the right and left tibias of 30 rats (Rattus norvegicus, Wistar). In the control group, the bone defects were filled with blood clot of the animal itself. After time intervals of 7, 30, and 90 days had elapsed, bone tissue biopsies (n = 5) were surgically obtained and submitted to laboratory processing. The response of bone tissue in contact with the materials was microscopically analyzed. The percentage of neoformed bone tissue in the defect was determined by means of planimetry counting points superimposed on the histologic image. Results Significant increase in the percentage of neoformed bone tissue was observed throughout the experimental periods in all groups (P < .05). For the cements EndoBinder and MTA (30 and 90 days), these percentage values were statistically higher than those of the control group (P < .05); however, they were similar to those of calcium hydroxide (P > .05). Conclusions EndoBinder and MTA allowed complete repair of bone defects created in rat tibias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Currently, there are many questions regarding the cleaning methods seeking greater efficiency and less loss of burs. Aim: the aim of this study was to evaluate the influence of cleaning methods on the cutting efficiency and morphological characteristics of stainless steel burs tungsten carbide (carbide). Materials and method: Thirty burs were divided into five groups (n = 5) according with the cleaning method: L1 - steel brush, L2 - nylon brush, L3 - ultrasound  +  distilled water, L4 - ultrasound + descaling solution and L5 - no cleaning method (control). The burs were used for the cutting of bovine enamel during six periods of 12 minutes each. After each period, the burs were cleaned (except L5 ) following the protocol established for each group. The cutting efficiency was determined by mass loss and morphological characteristics. Result: The average amount of wear after 72 minutes of use were L1  = 0.3558 g; L2  = 0.4275 g; L3  = 0.4652 g; L4  = 0.4396 g e L5  = 0.4854 g; significant differences in the time of use (p  <  0.001) and cleaning method (p  <  0.001). The L1 group showed the worst performance. Regardless of the experimental group, morphological analysis revealed alterations in the cutting blades soon after the first 12 minutes, being L1 the most affected group. Conclusion: The cleaning with wire brush was the most damaging method to the cutting efficiency and to the morphology of carbide burs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To evaluate the inflammatory process induced by Biodentine and mineral trioxide aggregate (MTA) in rat subcutaneous tissues. Methodology A polyethylene tube filled with Biodentine (n = 20) or MTA (n = 20) was placed into the dorsal subcutaneous of forty male rats; in the control group (CG; n = 20), empty tubes were implanted. After 7, 15, 30 and 60 days, the polyethylene tubes surrounded by connective tissue were fixed and embedded in paraffin. The number of inflammatory cells was estimated in HE-stained sections; numerical density of interleukin-6 (IL-6)-immunolabelled cells was also performed. The differences amongst the groups were analysed statistically by Tukey's test (P ≤ 0.05). Results A high number of inflammatory cells and IL-6-positive cells were observed at 7 days, in all groups; however, in the Biodentine group, the number of inflammatory cells and IL-6-immunolabelled cells was significantly higher (P ≤ 0.05) in comparison with the other groups at 7 and 15 days. In the capsules of animals from all groups, a gradual and significant reduction (P ≤ 0.05) of these parameters was seen over time. At 60 days, the capsules exhibited numerous fibroblasts and bundles of collagen fibres; in addition, the number of IL-6-positive cells was not significantly different amongst Biodentine, MTA and control groups. Conclusions There was a significant regression in the inflammatory reaction in the capsules indicating, therefore, that Biodentine is a biocompatible material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context: Calcium oxide (CaO) may be added to mineral trioxide aggregate (MTA) or Portland cement (PC) to improve physicochemical and biological properties. Aims: To evaluate the physicochemical properties of PC associated with radiopacifiers and CaO. Materials and Methods: MTA Angelus, PC + 30% zirconium oxide (Zr), or 30% niobium oxide (Nb) associated with 10 or 20% of CaO were evaluated. Gilmore needles were used to evaluate initial and final setting time. Compressive strength was evaluated after the periods of 24 hours and 21 days. pH was analyzed after 3, 12, 24 hours, 7, 14, 21 days. Solubility and flow tests were performed based on the ISO 6876. The data obtained were submitted to analysis of variance and Tukey tests (P ≤ 0.05). Results: The associations with 10% CaO showed greater strength that the associations with 20% CaO. The shortest initial setting time was observed for the association PC + Zr + 20% CaO and MTA. All the cements presented alkaline pH. The flow of all cements was similar. The highest solubility was found in the associations with 20% CaO. Conclusion: The addition of CaO to PC favored the alkaline property and the PC + Zr + 20% CaO presented setting time similar to MTA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the influence of the addition of 2% chlorhexidine digluconate (CHX) associated with 5% calcium chloride (CaCl2 ) on antimicrobial activity, setting time, pH and calcium release of gray mineral trioxide aggregate (GMTA). Materials and Methods: GMTA powder was mixed with water, 2% CHX alone or 2% CHX combined with 5% CaCl2 . Antimicrobial activity was determined against Enterococcus faecalis (ATCC 29212) strains by agar diffusion test. Data obtained were submitted to kruskal wallis tests. Analysis of the setting time was evaluated by American society for testing and materials C266-03 requirements. The pH and calcium release analysis were evaluated, in 24 h, 7, 14 and 28 days using pH meter equipment and atomic absorption spectrophotometer, respectively. Data obtained were analyzed by ANOVA, in 5% significance level. Results: Significant differences were seen (P < 0.01) among the zones of bacterial growth inhibition produced by 5% CaCl2 + 2% CHX combination against E. faecalis when compared with water (P < 0.05). Regarding the setting time, that combination had the shortest setting time (P < 0.05). All associations were alkaline and released calcium. No statistical difference was observed between the experimental groups at the different periods of analysis (P > 0.05). Conclusion: Combination of 5% CaCl2 + 2% CHX reduced the setting time and enhanced the antimicrobial activity of GMTA without changing the pH and calcium release.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Both Mineral Trioxide Aggregate (MTA) and Portland cement (PC) have been highlighted because of their favorable biological properties, with extensive applications in Endodontics, including the possibility of using into root canal filling. Objective: This article reviews literature related to MTA and PC comparing their physical, chemical and biological properties, as well as their indications. Literature review: Literature reports studies revealing the similarities between these materials’ properties, including both biocompatibility and bone repair induction. Moreover, there is the need for the development of a root canal sealer based on these materials (MTA and PC). Conclusion: MTA and CP show promissory perspective both in Dentistry and Endodontics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This case report presents an apical radicular perforation management using new calcium silicate-based cement (Biodentine) in a combined endodontic-periodontal lesion. The presence of apical radicular perforation may interfere in the endodontic treatment prognosis. Radicular perforation filling with bioactive cement through endodontic surgery is a possible treatment. This study presents an apical radicular perforation with periodontal involvement, due to alveolar bone loss on the buccal radicular surface from an incorrect intracanal preparation for the fiber post placing. The chosen alternative was a periapical surgery, the perforation was filled with a silicate and calcium chloride bioactive cement (Biodentine; Septodont, Saint-Maur-des-Fosses Cedex, France), and the radicular surface was etched with citric acid, because the access from root canal was impossible. The follow-up was for 8 months, through clinical and radiographic analysis. At the end of the follow-up, radiographic analyses showed the bone healing, and no clinical changes in periodontal probing depth, gingival recession, and the height of the interproximal mesial and distal papillae were observed. The root perforation treatment has a difficult management, especially when the dental root has a simultaneous periodontal commitment. The Biodentine proves to be a promising material for use in these situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study evaluated the radiopacity and flow of different endodontic sealers: AH Plus, Endo CPM, MTA Fillapex, Sealapex, Epiphany, and Epiphany SE. For the radiopacity test, six specimens measuring 10mm in diameter and 1mm in thickness were fabricated from each material. They were radiographed on an occlusal film alongside an aluminum step wedge. Radiographs were digitized to determine the radiopacity equivalence in millimeters of aluminum. To evaluate the flow, a 120 g load was placed on top of a glass slab containing 0.05 } 0.005ml of sealer. The diameters of each material were measured (mm) with a caliper and samples were photographed. Digitized images were analyzed using the UTHSCSA Image Tool for Windows software, to determine the sealer area (mm2). Data were submitted to ANOVA and Tukey's test at 5% significance. AH Plus and Epiphany SE presented the greatest radiopacity (12.5 mm Al and 12.0 mm Al, respectively) (p>0.05), followed by Epiphany (9.6 mm Al) and Fillapex (8.9 mm Al). Endo CPM (5.46 mm Al) and Sealapex (5.51 mm Al) presented lower radiopacity. MTA Fillapex presented significantly higher values of flow than other sealers (33.11 mm and 844.9 mm2). AH Plus, Epiphany, and Epiphany SE had similar values. Endo CPM (21.05 mm and 342.8 mm2) and Sealapex (19.98 mm and 352.5 mm2) presented the lowest flow values (p>0.05). All sealers presented radiopacity and flow values according to ISO and ANSI/ADA recommendations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the physicochemical properties and bioactivity of two formulations of calcium silicate-based cements containing additives (CSCM) or resin (CSCR), associated with radiopacifying agents zirconium oxide (ZrO2) and niobium oxide (Nb2O5) as micro- and nanoparticles; calcium tungstate (CaWO4); and bismuth oxide (Bi2O3). MTA Angelus was used as control. Methods. Surface features and bioactivity were evaluated by scanning electron microscopy and the chemical composition by energy dispersive X-ray spectrometry (EDS-X). Results. CSCM and CSCR presented larger particle sizes than MTA. Hydroxyapatite deposits were found on the surface of some materials, especially when associated with the radiopacifier with ZrO2 nanoparticles. All the cements presented calcium, silicon, and aluminum in their composition. Conclusion. Both calcium silicate-based cements presented composition and bioactivity similar to MTA when associated with the radiopacifiers evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Mineral Trioxide Aggregate (MTA) has excellent biological property. However, its consistency makes it difficult to be inserted into retrograde cavities. Objective:To evaluate the ability of different methods to fill retrograde cavities with MTA. Material and methods: Root canals of thirty single-rooted resin teeth were prepared and filled. After the cut of 3 mm short of apical third, retrograde cavities with 3 mm deep were prepared using an ultrasound device and retrotips (CVD, São José dos Campos, SP, Brazil). The retrograde preparation was evaluate by using an operative microscope (D.F. Vasconcellos, São Paulo, SP, Brazil). The teeth were randomly divided into three groups (n = 10), according to the method: 1) condenser (Trinity, São Paulo, SP, Brazil); 2) MTA applicator (Angelus, Londrina, Brazil) + condenser; 3) condenser associated with ultrasound (CVD, São José dos Campos, SP, Brazil). After the filling of retrograde cavities with white MTA (Angelus, Londrina, Brazil), teeth were radiographed using a digital system (Kodak RVG 6000, Rochester, NY, USA). The images were analyzed by UTHSCSA Image Tool 3.0 software. The percentage of filling was calculated by the proportion between the total area of retrograde cavity and the filled area. The radiographic density mean of each third of retrograde cavity filled with MTA was measured by using the histogram tool of the software. The results were submitted to ANOVA and Tukey tests, with 5% of significance. Results: There was no difference in percentage of filling among the groups (p > 0.05) (approximately 85%). By comparing the thirds, the condenser and MTA applicator groups showed higher density for apical and middle third than cervical third (p < 0.05). The ultrasound group presented similar density among the thirds. Conclusion: The filling ability was similar for the studied methods. Ultrasound promoted better distribution of MTA in retrograde cavity, but did not increase the density of material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to characterize and to evaluate the bioactivity potential of experimental root canal sealers (ES) based on Portland cement, epoxy resin with nano- and micro-particles of niobium or zirconium oxide used as radiopacifiers in comparison to AH Plus and MTA Fillapex. Methods Specimens of the sealers (10 mm in diameter × 1 mm thick) were prepared and the radiopacity was evaluated according to ISO 6876 (2012) specifications. Characterization of the sealers was performed under the scanning electron microscope (SEM) immediately after setting and after immersion for 28 days in Hank's balanced salt solution (HBSS). In addition X-ray energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy were also performed. The pH and calcium ion release were measured after 1, 7, 14, 21 and 28 days after completion of seating using a digital pH meter and an atomic absorption spectrophotometer, respectively. Results The experimental sealers exhibited an average radiopacity of 2.5 mm thickness of aluminum, which was similar to MTA Fillapex (P > 0.05) and inferior to AH Plus (P < 0.05). AH Plus did not show bioactivity. Although the experimental sealers did not exhibit the formation of hydration product, they encouraged the deposition of crystalline spherical structures of calcium deficient phosphate. The highest pH and calcium release values were observed with the experimental sealers (P < 0.01). ES-Nb-micro was the only sealer to present hexagonal shaped crystal deposition. Significance Novel root canal sealers based on a mixture of Portland cement, epoxy resin and radiopacifier exhibited a degree of bioactivity although no evidence of cement hydration was demonstrated on material characterization. The radiopacifier particle size had limited effect on the sealer microstructure and chemical properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)