908 resultados para strip aquifers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The growing interest in the use of groundwater resources is directly related to the economic advantages that the groundwater exploitation offers when compared to surface waters. This happens especially in large urban centers, such as the city of Americana / SP, where the rivers are increasingly contaminated by household and industrial waste. Therefore, this study aimed to characterize the Tubarão Aquifer System, in the city of Americana, to identify and evaluate the spatial distribution of different hydrogeochemical facies as well as understand the rock-fluid interaction through the construction of a conceptual hydrogeochemical model. This study was made based on the recognition of the possible chemical reactions that print the chemical characteristics of groundwater in the area. To do the job, there were two water sampling campaigns of all deep wells used by the City of Americana public water supply. From the results of hydrochemical, classification of water was made by Piper and Stiff diagrams as well as geostatistical data using cluster analysis of principal components. Based on information from the profiles obtained from the survey SIAGAS as well as in geological profiles provided by the city of Americana, we sought to detail the subsurface geology of the Subgroup Itararé in the city of Americana. The results obtained allowed the identification of three hydrochemical types in the study area: Bicarbonated calcium-sodium (1), bicarbonate sodium (2) and sodium chloride (3). The waters have bicarbonate alkaline pH to alkaline and can be considered weakly saline, with electrical conductivity values of around 161 mS / cm. Samples classified as sodium bicarbonate average of 174.99 mS / cm. The pH values ranging from 6.74 to 7.99, averaging 7.52. For the group of waters classified as sodium chloride, conductivity average is 164.32 mS / cm and pH values ranging... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Concerns about the quality of groundwater have been continuously rising, considering its importance for the public water supply in the State of São Paulo, and even more due to the impact that anthropic action has been causing to the original quality of that natural resource. It is extremely relevant to identify the contamination focuses along the aquifers of the State of São Paulo. This report aims to evaluate nitrates and fluorides concentrations along the aquifers present in the state, in order to identify places where change in the quality of groundwater is observed, through the comparison between measured concentrations and reference values, such as: “Intervention Value” (maximum allowed value) and “Alert Value” (attention required value). To perform this research, a full compilation and organization has been done on chemical analysis data from the “Sistema de Informações de Águas Subterrâneas - SIDAS”, made available by the “Divisão de Procedimentos de Outorga – DPO” of the “Departamento de Água e Energia Elétrica – DAEE”. This work has made possible the build-up of a database composed by 6,860 wells, with analytical data ready to be interpreted, containing information about water pH, electrical conductivity, hardness and chloride, iron, fluoride, nitrogen, nitrates and total dissolved solids concentrations. This database shows concentration data for nitrates (6,157 wells) and fluoride (3,316 wells). From this information, maps for nitrates and fluorides concentration distributions have been made, by each aquifer and each “Unidade de Gerenciamento de Recursos Hídricos – UGRHI”, which has enabled the identification of wells where the concentrations of these chemical compounds exceeds the reference values. Concerning nitrates, these analysis indicated the existence of contamination sources from rural and urban zones, mostly present in the west region... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The success achieved by the use of composite resins in anterior teeth precipitately leads their use in posterior teeth. However, the indiscriminate application of these materials in cavities with several diverse sizes rapidly pointed out their lack of resistance to oclusal and proximal wear. OBJECTIVE: To evaluate the surface roughness of composite resin in relation to finishing and polishing technique. MATERIAL AND METHODS: Eight experimental groups (n = 15) were divided according to finishing and polishing technique: G1 – Z250TM composite resin without surface finishing and polishing; G2 – Z250TM composite resin plus surface finishing and polishing; G3 – P60TM composite resin without surface finishing and polishing; G4 – P60TM composite resin plus surface finishing and polishing; G5 – Prodigy CondensableTM composite resin without surface finishing and polishing; G6 – Prodigy CondensableTM composite resin plus surface finishing and polishing; G7 – SurefillTM composite resin without surface finishing and polishing; G8 – SurefillTM composite resin plus surface finishing and polishing. Three packable and one microhybrid (control group) composite resin was used. The surface roughness was measured using a profilometer at three points in each sample. The results were evaluated by ANOVA and Tukey test (p < 0.05). RESULTS: Prodigy CondensableTM composite resin showed the lowest surface roughness, while SurefillTM showed the highest surface roughness. Comparing the resins used, only between P60TM and SurefillTM there were no statistically significant differences (p > 0,05). CONCLUSION: Surface roughness was lower in all types of resin composites surfaces in contact with Mylar matrix strip than in areas submitted to finishing and polishing procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High fuel consumption and its inadequate control in fuel stations caused the pollution of soil and aquifers. These consequences created more concern with the increased exploration of aquifers to supply the groundwater demand. The objective of this study was to evaluate the eficiency and efectiveness of the of pump and treat technique of the water applied to the Coastal Aquifer in the cleaning up of the plumes produced by the leaking of fuel in the gas station Auto Posto Baía do Sol Ltda. The gas station is located in São Sebastião, in the north coast of São Paulo State. In the case of Auto Posto Baía do Sol Ltda., the technique of pump and treat was eficient and the plume produced by the leakage was completely removed. However, the efectiveness of this technique was low due to the long time required for the complete operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aims of this study were (1) to synthesize and characterize random and aligned nanocomposite fibers of multi-walled carbon nanotubes (MWCNT)/nylon-6 and (2) to determine their reinforcing effects on the flexural strength of a dental resin composite.Nylon-6 was dissolved in hexafluoropropanol (10 wt%), followed by the addition of MWCNT (hereafter referred to as nanotubes) at two distinct concentrations (i.e., 0.5 or 1.5 wt%). Neat nylon-6 fibers (without nanotubes) were also prepared. The solutions were electrospun using parameters under low- (120 rpm) or high-speed (6000 rpm) mandrel rotation to collect random and aligned fibers, respectively. The processed fiber mats were characterized by scanning (SEM) and transmission (TEM) electron microscopies, as well as by uni-axial tensile testing. To determine the reinforcing effects on the flexural strength of a dental resin composite, bar-shaped (20 x 2 x 2 mm(3)) resin composite specimens were prepared by first placing one increment of the composite, followed by one strip of the mat, and one last increment of composite. Non-reinforced composite specimens were used as the control. The specimens were then evaluated using flexural strength testing. SEM was done on the fractured surfaces. The data were analyzed using ANOVA and the Tukey's test (alpha=5%).Nanotubes were successfully incorporated into the nylon-6 fibers. Aligned and random fibers were obtained using high- and low-speed electrospinning, respectively, where the former were significantly (p<0.001) stronger than the latter, regardless of the nanotubes'presence. Indeed, the dental resin composite tested was significantly reinforced when combined with nylon-6 fibrous mats composed of aligned fibers (with or without nanotubes) or random fibers incorporated with nanotubes at 0.5 wt%. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiogenic He-4 is produced by the decay of uranium and thorium in the Earths mantle and crust. From here, it is degassed to the atmosphere(1-5) and eventually escapes to space(1,5,6). Assuming that all of the He-4 produced is degassed, about 70% of the total He-4 degassed from Earth comes from the continental crust(2,-5,7). However, the outgoing flux of crustal He-4 has not been directly measured at the Earths surface(2) and the migration pathways are poorly understood(2-4,7,8). Here we present measurements of helium isotopes and the long-lived cosmogenic radio-isotope Kr-81 in the deep, continental-scale Guarani aquifer in Brazil and show that crustal He-4 reaches the atmosphere primarily by the surficial discharge of deep groundwater. We estimate that He-4 in Guarani groundwater discharge accounts for about 20% of the assumed global flux from continental crust, and that other large aquifers may account for about 33%. Old groundwater ages suggest that He-4 in the Guarani aquifer accumulates over half- to one-million-year timescales. We conclude that He-4 degassing from the continents is regulated by groundwater discharge, rather than episodic tectonic events, and suggest that the assumed steady state between crustal production and degassing of He-4, and its resulting atmospheric residence time, should be re-examined.