874 resultados para strategic performance measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several methods have been suggested to estimate non-linear models with interaction terms in the presence of measurement error. Structural equation models eliminate measurement error bias, but require large samples. Ordinary least squares regression on summated scales, regression on factor scores and partial least squares are appropriate for small samples but do not correct measurement error bias. Two stage least squares regression does correct measurement error bias but the results strongly depend on the instrumental variable choice. This article discusses the old disattenuated regression method as an alternative for correcting measurement error in small samples. The method is extended to the case of interaction terms and is illustrated on a model that examines the interaction effect of innovation and style of use of budgets on business performance. Alternative reliability estimates that can be used to disattenuate the estimates are discussed. A comparison is made with the alternative methods. Methods that do not correct for measurement error bias perform very similarly and considerably worse than disattenuated regression

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In epidemiologic studies, measurement error in dietary variables often attenuates association between dietary intake and disease occurrence. To adjust for the attenuation caused by error in dietary intake, regression calibration is commonly used. To apply regression calibration, unbiased reference measurements are required. Short-term reference measurements for foods that are not consumed daily contain excess zeroes that pose challenges in the calibration model. We adapted two-part regression calibration model, initially developed for multiple replicates of reference measurements per individual to a single-replicate setting. We showed how to handle excess zero reference measurements by two-step modeling approach, how to explore heteroscedasticity in the consumed amount with variance-mean graph, how to explore nonlinearity with the generalized additive modeling (GAM) and the empirical logit approaches, and how to select covariates in the calibration model. The performance of two-part calibration model was compared with the one-part counterpart. We used vegetable intake and mortality data from European Prospective Investigation on Cancer and Nutrition (EPIC) study. In the EPIC, reference measurements were taken with 24-hour recalls. For each of the three vegetable subgroups assessed separately, correcting for error with an appropriately specified two-part calibration model resulted in about three fold increase in the strength of association with all-cause mortality, as measured by the log hazard ratio. Further found is that the standard way of including covariates in the calibration model can lead to over fitting the two-part calibration model. Moreover, the extent of adjusting for error is influenced by the number and forms of covariates in the calibration model. For episodically consumed foods, we advise researchers to pay special attention to response distribution, nonlinearity, and covariate inclusion in specifying the calibration model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Perfusion CT studies of regional cerebral blood flow (rCBF), involving sequential acquisition of cerebral CT sections during IV contrast material administration, have classically been reported to be achieved at 120 kVp. We hypothesized that using 80 kVp should result in the same image quality while significantly lowering the patient's radiation dose, and we evaluated this assumption. In five patients undergoing cerebral CT survey, one section level was imaged at 120 kVp and 80 kVp, before and after IV administration of iodinated contrast material. These four cerebral CT sections obtained in each patient were analyzed with special interest to contrast, noise, and radiation dose. Contrast enhancement at 80 kVp is significantly increased (P < .001), as well as contrast between gray matter and white matter after contrast enhancement (P < .001). Mean noise at 80 kVp is not statistically different (P = .042). Finally, performance of perfusion CT studies at 80 kVp, keeping mAs constant, lowers the radiation dose by a factor of 2.8. We, thus, conclude that 80 kVp acquisition of perfusion CT studies of rCBF will result in increased contrast enhancement and should improve rCBF analysis, with a reduced patient's irradiation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Given that firms develop their activities in a network of multiple players, interfirm rivalry is not only a matter of direct competitors, but also of indirect competition. In spite of this, the literature on competitive dynamics tends to focus on analyzing rivalry as an exclusive function of the competitive relationship between a focal firm and its direct rivals. In this article, we extend competitive dynamics literature by considering how focal firms are affected by the relationships of their rivals with third-party firms. Specifically, we study the effect that the multimarket contacts of rivals produces on the performance of the focal firm. Additionally, we incorporate the idea that there are different strategic options for operating in an industry that affect the intensity of multimarket contact externalities. Our results show that multimarket contact among firms causes externalities that indirectly affect firms that are not directly involved in this competitive relationship. We find that multimarket contact externalities differ between and within strategic groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Little attention has been paid so far to the influence of the chemical nature of the substance when measuring δ 15N by elemental analysis (EA)-isotope ratio mass spectrometry (IRMS). Although the bulk nitrogen isotope analysis of organic material is not to be questioned, literature from different disciplines using IRMS provides hints that the quantitative conversion of nitrate into nitrogen presents difficulties. We observed abnormal series of δ 15N values of laboratory standards and nitrates. These unexpected results were shown to be related to the tailing of the nitrogen peak of nitrate-containing compounds. A series of experiments were set up to investigate the cause of this phenomenon, using ammonium nitrate (NH4NO3) and potassium nitrate (KNO3) samples, two organic laboratory standards as well as the international secondary reference materials IAEA-N1, IAEA-N2-two ammonium sulphates [(NH4)2SO4]-and IAEA-NO-3, a potassium nitrate. In experiment 1, we used graphite and vanadium pentoxide (V2O5) as additives to observe if they could enhance the decomposition (combustion) of nitrates. In experiment 2, we tested another elemental analyser configuration including an additional section of reduced copper in order to see whether or not the tailing could originate from an incomplete reduction process. Finally, we modified several parameters of the method and observed their influence on the peak shape, δ 15N value and nitrogen content in weight percent of nitrogen of the target substances. We found the best results using mere thermal decomposition in helium, under exclusion of any oxygen. We show that the analytical procedure used for organic samples should not be used for nitrates because of their different chemical nature. We present the best performance given one set of sample introduction parameters for the analysis of nitrates, as well as for the ammonium sulphate IAEA-N1 and IAEA-N2 reference materials. We discuss these results considering the thermochemistry of the substances and the analytical technique itself. The results emphasise the difference in chemical nature of inorganic and organic samples, which necessarily involves distinct thermochemistry when analysed by EA-IRMS. Therefore, they should not be processed using the same analytical procedure. This clearly impacts on the way international secondary reference materials should be used for the calibration of organic laboratory standards.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Voriconazole (VRC) is a broad-spectrum antifungal triazole with nonlinear pharmacokinetics. The utility of measurement of voriconazole blood levels for optimizing therapy is a matter of debate. Available high-performance liquid chromatography (HPLC) and bioassay methods are technically complex, time-consuming, or have a narrow analytical range. Objectives of the present study were to develop new, simple analytical methods and to assess variability of voriconazole blood levels in patients with invasive mycoses. Acetonitrile precipitation, reverse-phase separation, and UV detection were used for HPLC. A voriconazole-hypersusceptible Candida albicans mutant lacking multidrug efflux transporters (cdr1Delta/cdr1Delta, cdr2Delta/cdr2Delta, flu1Delta/flu1Delta, and mdr1Delta/mdr1Delta) and calcineurin subunit A (cnaDelta/cnaDelta) was used for bioassay. Mean intra-/interrun accuracies over the VRC concentration range from 0.25 to 16 mg/liter were 93.7% +/- 5.0%/96.5% +/- 2.4% (HPLC) and 94.9% +/- 6.1%/94.7% +/- 3.3% (bioassay). Mean intra-/interrun coefficients of variation were 5.2% +/- 1.5%/5.4% +/- 0.9% and 6.5% +/- 2.5%/4.0% +/- 1.6% for HPLC and bioassay, respectively. The coefficient of concordance between HPLC and bioassay was 0.96. Sequential measurements in 10 patients with invasive mycoses showed important inter- and intraindividual variations of estimated voriconazole area under the concentration-time curve (AUC): median, 43.9 mg x h/liter (range, 12.9 to 71.1) on the first and 27.4 mg x h/liter (range, 2.9 to 93.1) on the last day of therapy. During therapy, AUC decreased in five patients, increased in three, and remained unchanged in two. A toxic encephalopathy probably related to the increase of the VRC AUC (from 71.1 to 93.1 mg x h/liter) was observed. The VRC AUC decreased (from 12.9 to 2.9 mg x h/liter) in a patient with persistent signs of invasive aspergillosis. These preliminary observations suggest that voriconazole over- or underexposure resulting from variability of blood levels might have clinical implications. Simple HPLC and bioassay methods offer new tools for monitoring voriconazole therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown into focus the differences in information provided by activity assays and immunoassays for renin and prorenin measurement and has drawn attention to the need for precautions to ensure their accurate measurement. CONTENT: Renin activity assays and immunoassays provide related but different information. Whereas activity assays measure only active renin, immunoassays measure both active and inhibited renin. Particular care must be taken in the collection and processing of blood samples and in the performance of these assays to avoid errors in renin measurement. Both activity assays and immunoassays are susceptible to renin overestimation due to prorenin activation. In addition, activity assays performed with peptidase inhibitors may overestimate the degree of inhibition of PRA by renin inhibitor therapy. Moreover, immunoassays may overestimate the reactive increase in plasma renin concentration in response to renin inhibitor therapy, owing to the inhibitor promoting conversion of prorenin to an open conformation that is recognized by renin immunoassays. CONCLUSIONS: The successful application of renin assays to patient care requires that the clinician and the clinical chemist understand the information provided by these assays and of the precautions necessary to ensure their accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Agency Performance Report for the Governor’s Office of Drug Control Policy is published in accordance with the Accountable Government Act. The information provided within this report is to aid in decision-making and to illustrate accountability to stakeholders and citizens. The report is indicative of the agency’s progress in meeting performance targets and achieving goals consistent with the enterprise strategic plan, the agency strategic plan and agency performance plan.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). METHODS: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. RESULTS: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. CONCLUSION: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Agency Performance Report for the Governor’s Office of Drug Control Policy is published in accordance with the Accountable Government Act. The information provided within this report is to aid in decision-making and to illustrate accountability to stakeholders and citizens. The report is indicative of the agency’s progress in meeting performance targets and achieving goals consistent with the enterprise strategic plan, the agency strategic plan and agency performance plan.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Organizations often face the challenge of communicating their strategiesto local decision makers. The difficulty presents itself in finding away to measure performance wich meaningfully conveys how to implement theorganization's strategy at local levels. I show that organizations solvethis communication problem by combining performance measures in such away that performance gains come closest to mimicking value-added asdefined by the organization's strategy. I further show how organizationsrebalance performance measures in response to changes in their strategies.Applications to the design of performance metrics, gaming, and divisionalperformance evaluation are considered. The paper also suggests severalempirical ways to evaluate the practical importance of the communicationrole of measurement systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The original and modified Wells score are widely used prediction rules for pre-test probability assessment of deep vein thrombosis (DVT). The objective of this study was to compare the predictive performance of both Wells scores in unselected patients with clinical suspicion of DVT.Methods: Consecutive inpatients and outpatients with a clinical suspicion of DVT were prospectively enrolled. Pre-test DVT probability (low/intermediate/high) was determined using both scores. Patients with a non-high probability based on the original Wells score underwent D-dimers measurement. Patients with D-dimers <500 mu g/L did not undergo further testing, and treatment was withheld. All others underwent complete lower limb compression ultrasound, and those diagnosed with DVT were anticoagulated. The primary study outcome was objectively confirmed symptomatic venous thromboembolism within 3 months of enrollment.Results: 298 patients with suspected DVT were included. Of these, 82 (27.5%) had DVT, and 46 of them were proximal. Compared to the modified score, the original Wells score classified a higher proportion of patients as low-risk (53 vs 48%; p<0.01) and a lower proportion as high-risk (17 vs 15%; p=0.02); the prevalence of proximal DVT in each category was similar with both scores (7-8% low, 16-19% intermediate, 36-37% high). The area under the receiver operating characteristic curve regarding proximal DVT detection was similar for both scores, but they both performed poorly in predicting isolated distal DVT and DVT in inpatients.Conclusion: The study demonstrates that both Wells scores perform equally well in proximal DVT pre-test probability prediction. Neither score appears to be particularly useful in hospitalized patients and those with isolated distal DVT. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

I am pleased to present the performance report for the Iowa Department for the Blind for fiscal year 2005. This report is provided in compliance with sections 8E.210 and 216B.7 of the Code of Iowa. It contains valuable information about the services the Department and its partners provided for Iowans during the past fiscal year in the areas of vocational rehabilitation, library services, and resource management. Major accomplishments of the year included new food service opportunities in the Randolph-Sheppard program, extensive remodeling of the Adult Orientation and Adjustment Center, and continued national prominence in vocational rehabilitation as measured by the U.S. Rehabilitation Services Administration, which on June 13, 2005 released data on federal standards and indicators for the year ended September 30, 2004. Earnings ratios and the percentage of employment for vocational rehabilitation clients of the Department remain among the best in the nation. This is corroborated by a report released in September, 2005 by the U.S. Government Accountability Office, which tested and summarized datasets compiled by the U.S. Department of Education for the nation’s 80 vocational rehabilitation agencies. Overall, we met or exceeded 26 of 32 results targets included in this report. Key strategic challenges, developments, and trends are also discussed in the "Department Overview" that follows. Sincerely, Allen C. Harris Director, Iowa Department for the Blind

Relevância:

30.00% 30.00%

Publicador:

Resumo:

I am pleased to present the performance report for the Iowa Department for the Blind for fiscal year 2006. This report is provided in compliance with sections 8E.210 and 216B.7 of the Code of Iowa. It contains valuable information about the services the Department and its partners provided for Iowans during the past fiscal year in the areas of vocational rehabilitation, library services, and resource management. Major accomplishments of the year included successful administration of a federally-funded mentoring program (Pathfinders) that matches young adults ages 16-26 who are blind or visually impaired with mentors who also have vision loss, installed a state-of-the art digital recording studio in the library, and continued national prominence in vocational rehabilitation. Earnings ratios and the percentage of employment for vocational rehabilitation clients of the Department remain among the best in the nation, as measured by the U.S. Rehabilitation Services Administration, which on July 3, 2006 released data on federal standards and indicators for the year ended September 30, 2005. Overall, we met or exceeded 15 of 20 results targets included in this report. Key strategic challenges, developments, and trends are also discussed in the "Department Overview" that follows. Sincerely, Allen C. Harris Director, Iowa Department for the Blind

Relevância:

30.00% 30.00%

Publicador:

Resumo:

I am pleased to present the performance report for the Iowa Department for the Blind for fiscal year 2007. This report is provided in compliance with sections 8E.210 and 216B.7 of the Code of Iowa. It contains valuable information about the services the Department and its partners provided for Iowans during the past fiscal year in the areas of Vocational Rehabilitation, Independent Living, Library Services, and Resource Management. The Department determines its competitive success in a number of ways. We look at the federal standards and indicators to learn our ranking in relation to the performance of other public rehabilitation agencies. We compare our library's production and circulation figures with those from previous years to determine trends. We set our own standards for success by looking at such factors as the number of successful case closures, average hourly wage at case closure, skills training provided, and compliance with regulations. Results show that the Department is working positively toward achieving its strategic goals of increasing the independence and productivity of blind Iowans and improving access to information for blind Iowans. Major accomplishments of the year included the selection of our Library as the only agency authorized to distribute educational materials using the National Instructional Materials Accessibility Standard (NIMAS) to students in Iowa. Our Independent Living program received the Shining Star award at the Governor's Conference on Aging for its work with and outreach to older blind Iowans. The Department, the Iowa Braille School, and the Department of Education implemented new cooperative efforts to improve the coordination and delivery of services to blind and visually impaired students in Iowa. Finally, earnings ratios and the percentage of employment for vocational rehabilitation clients of the Department remain among the best in the nation, as measured by the U.S. Rehabilitation Services Administration, which on June 27, 2007 released data on federal standards and indicators for the year ended September 30, 2006. Overall, we met or exceeded 11 of 16 results targets included in this report. A discussion of the Department's services, customers, organizational structure, and budget appears in the "Department Overview" that follows. The success of the Department's programs is evident in the success achieved by blind Iowans. It is reflected in the many blind persons who can be seen traveling about independently, going to their jobs and to the community and family activities in which they participate. Sincerely, Allen C. Harris Director, Iowa Department for the Blind