898 resultados para standard vector control scheme
Resumo:
PURPOSE: To evaluate the safety and efficacy of an intravitreal fluocinolone acetonide (FA) implant compared with standard therapy in subjects with noninfectious posterior uveitis (NIPU). DESIGN: Randomized, controlled, phase 2b/3, open-label, multicenter superiority trial. PARTICIPANTS: Subjects with unilateral or bilateral NIPU. METHODS: One hundred forty subjects received either a 0.59-mg FA intravitreal implant (n = 66) or standard of care (SOC; n = 74) with either systemic prednisolone or equivalent corticosteroid as monotherapy (> or =0.2 mg/kg daily) or, if judged necessary by the investigator, combination therapy with an immunosuppressive agent plus a lower dose of prednisolone or equivalent corticosteroid (> or =0.1 mg/kg daily). MAIN OUTCOME MEASURES: Time to first recurrence of uveitis. RESULTS: Eyes that received the FA intravitreal implant experienced delayed onset of observed recurrence of uveitis (P<0.01) and a lower rate of recurrence of uveitis (18.2% vs. 63.5%; P< or =0.01) compared with SOC study eyes. Adverse events frequently observed in implanted eyes included elevated intraocular pressure (IOP) requiring IOP-lowering surgery (occurring in 21.2% of implanted eyes) and cataracts requiring extraction (occurring in 87.8% of phakic implanted eyes). No treatment-related nonocular adverse events were observed in the implant group, whereas such events occurred in 25.7% of subjects in the SOC group. CONCLUSIONS: The FA intravitreal implant provided better control of inflammation in patients with uveitis compared with systemic therapy. Intraocular pressure and lens clarity of implanted eyes need close monitoring in patients receiving the FA intravitreal implant.
Resumo:
Background: Urine is still the matrix of choice to fight against doping, because it can be collected non-invasively during anti-doping tests. Most of the World Anti-Doping Agency's accredited laboratories have more than 20 years experience in analyzing this biological fluid and the majority of the compounds listed in the 2010 Prohibited List - International Standard are eliminated through the urinary apparatus. Storing and transporting urine samples for doping analyses does not include a specific protocol to prevent microbial and thermal degradation. The use of a rapid and reliable screening method could enable determine reference intervals for urine specimens in doping control samples and evaluate notably the prevalence of microbial contamination known to be responsible for the degradation of chemical substances in urine.Methods: The Sysmex(R) UF-500i is a recent urine flow cytometer analyzer capable of quantifying BACT and other urinary particles such as RBC, WBC, EC, DEBRIS, CAST, PATH. CAST, YLC, SRC as well as measuring urine conductivity. To determine urine anti-doping reference intervals, 501 samples received in our laboratory over a period of two months were submitted to an immediate examination. All samples were collected and then transported at room temperature. Analysis of variance was performed to test the effects of factors such as gender, test type [in-competition, out-of-competition] and delivery time.Results: The data obtained showed that most of the urine samples were highly contaminated with bacteria. The other urine particles were also very different according to the factors.Conclusions: The Sysmex(R) UF-500i was capable of providing a snapshot of urine particles present in the samples at the time of the delivery to the laboratory. These particles, BACT in particular, gave a good idea of the possible microbial degradation which had and/or could have occurred in the sample. This information could be used as the first quality control set up in WADA (World Anti-Doping Agency) accredited laboratories to determine if steroid profiles, endogenous and prohibited substances have possibly been altered. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Peer-reviewed
Resumo:
This paper describes an audio watermarking scheme based on lossy compression. The main idea is taken from an image watermarking approach where the JPEG compression algorithm is used to determine where and how the mark should be placed. Similarly, in the audio scheme suggested in this paper, an MPEG 1 Layer 3 algorithm is chosen for compression to determine the position of the mark bits and, thus, the psychoacoustic masking of the MPEG 1 Layer 3compression is implicitly used. This methodology provides with a high robustness degree against compression attacks. The suggested scheme is also shown to succeed against most of the StirMark benchmark attacks for audio.
Resumo:
Tutkielman tavoitteena on rakentaa toimiva ympäristöjärjestelmä Thermo Fisher Scientific Oy:lle. Tutkimuksen tarkoituksena on myös löytää kahdelle täysin erilaiselle toiminnalle yhtenäinen ympäristöjärjestelmä, jonka avulla pystytään ottamaan huomioon molempien toimipaikkojen hieman erilaiset vaatimukset. Lisäksi tavoitteena on muodostaa ympäristöjärjestelmälle oma organisaatio, jonka avulla ympäristöjärjestelmän integrointi yrityksen prosesseihin voidaan suorittaa sujuvasti. Aluksi tutkimusongelmaa lähestytään teoreettisesta näkökulmasta,jossa tarkastellaan ympäristöjärjestelmän historiaa, rakennetta, etuja sekä ISO 14001–standardin rakennetta ja sen etenemistä ympäristöjärjestelmän rakentamisen yhteydessä aina kolmannen osapuolen sertifiointiin asti. Empiria osa alkaa alustavalla ympäristökatselmuksella, jossa selvitetään ympäristöasioiden hoidon nykytaso ja luodaan pohja koko ympäristöjärjestelmän luomiselle, jonka vankimpana perustana on ympäristöpolitiikka. Johdon hyväksymä ympäristöpolitiikka varmistaa johdon sitoutumisen järjestelmään. Ympäristöjärjestelmän toimintarakenteen muodostaminen kahdelle erilaiselle toiminnalle onnistui tutkimuksessa kiitettävästi. Se miten ympäristöjärjestelmä toimii todellisuudessa, tullaan näkemään käytännön kokemuksien yhteydessä.
Resumo:
Carnitine palmitoyltransferase-1 (CPT-1) liver isoform or CPT-1a is implicated in CNS control of food intake. However, the exact brain nucleus site(s) in mediating this action of CPT-1a has not been identified. In this report, we assess the role of CPT-1a in hypothalamic ventromedial nucleus (VMN). We stereotaxically injected an adenoviral vector containing CPT-1a coding sequence into the VMN of rats to induce overexpression and activation of CPT-1a. The VMN-selective activation of CPT-1a induced orexigenic effect, suggesting CPT-1a in the VMN is involved in the central control of feeding. Intracerebroventricular administration of etomoxir, a CPT-1 inhibitor, decreases food intake. Importantly, in the animals with VMN-overexpression of a CPT-1a mutant that antagonizes the CPT-1 inhibition by etomoxir, the anorectic response to etomoxir was attenuated. This suggests that VMN is involved in mediating the anorectic effect of central inhibition of CPT-1a. In contrast, Arc overexpression of the mutant did not alter etomoxir-induced inhibition of food intake, suggesting that Arc CPT-1a does not play significant roles in this anorectic action. Furthermore, in the VMN, CPT-1a appears to act downstream of hypothalamic malonyl-CoA action of feeding. Finally, we show that in the VMN, CPT-1 activity altered in concert with fasting and refeeding states, supporting a physiological role of CPT-1a in mediating the control of feeding. Taking together, CPT-1a in the hypothalamic VMN appears to play an important role in the central control of food intake. VMN-selective modulation of CPT-1a activity may therefore be a promising strategy in controlling food intake and maintaining normal body weight.
Resumo:
Monitoring of cytomegalovirus cell-mediated immunity is a promising tool for the refinement of preventative and therapeutic strategies posttransplantation. Typically, the interferon-γ response to T cell stimulation is measured. We evaluated a broad range of cytokine and chemokines to better characterize the ex vivo host-response to CMV peptide stimulation. In a cohort of CMV viremic organ transplant recipients, chemokine expression-specifically CCL8 (AUC 0.849 95% CI 0.721-0.978; p = 0.003) and CXCL10 (AUC 0.841, 95% CI 0.707-0.974; p = 0.004)-was associated with control of viral replication. In a second cohort of transplant recipients at high-risk for CMV, the presence of a polymorphism in the CCL8 promoter conferred an increased risk of viral replication after discontinuation of antiviral prophylaxis (logrank hazard ratio 3.6; 95% CI 2.077-51.88). Using cell-sorting experiments, we determined that the primary cell type producing CCL8 in response to CMV peptide stimulation was the monocyte fraction. Finally, in vitro experiments using standard immunosuppressive agents demonstrated a dose-dependent reduction in CCL8 production. Chemokines appear to be important elements of the cell-mediated response to CMV infection posttransplant, as here suggested for CCL8, and translation of this knowledge may allow for the tailoring and improvement of preventative strategies.
Resumo:
BACKGROUND: Survival outcomes for patients with glioblastoma remain poor, particularly for patients with unmethylated O(6)-methylguanine-DNA methyltransferase (MGMT) gene promoter. This phase II, randomized, open-label, multicenter trial investigated the efficacy and safety of 2 dose regimens of the selective integrin inhibitor cilengitide combined with standard chemoradiotherapy in patients with newly diagnosed glioblastoma and an unmethylated MGMT promoter. METHODS: Overall, 265 patients were randomized (1:1:1) to standard cilengitide (2000 mg 2×/wk; n = 88), intensive cilengitide (2000 mg 5×/wk during wk 1-6, thereafter 2×/wk; n = 88), or a control arm (chemoradiotherapy alone; n = 89). Cilengitide was administered intravenously in combination with daily temozolomide (TMZ) and concomitant radiotherapy (RT; wk 1-6), followed by TMZ maintenance therapy (TMZ/RT→TMZ). The primary endpoint was overall survival; secondary endpoints included progression-free survival, pharmacokinetics, and safety and tolerability. RESULTS: Median overall survival was 16.3 months in the standard cilengitide arm (hazard ratio [HR], 0.686; 95% CI: 0.484, 0.972; P = .032) and 14.5 months in the intensive cilengitide arm (HR, 0.858; 95% CI: 0.612, 1.204; P = .3771) versus 13.4 months in the control arm. Median progression-free survival assessed per independent review committee was 5.6 months (HR, 0.822; 95% CI: 0.595, 1.134) and 5.9 months (HR, 0.794; 95% CI: 0.575, 1.096) in the standard and intensive cilengitide arms, respectively, versus 4.1 months in the control arm. Cilengitide was well tolerated. CONCLUSIONS: Standard and intensive cilengitide dose regimens were well tolerated in combination with TMZ/RT→TMZ. Inconsistent overall survival and progression-free survival outcomes and a limited sample size did not allow firm conclusions regarding clinical efficacy in this exploratory phase II study.
Resumo:
Tässä työssä käsitellään muutoksia, joita EGPRS-standardi aiheuttaa matkapuhelimen fyysiselle signalointiprotokollatasolle. EGPRS on laajennus normaaliin GPRS-verkkoon ja se mahdollistaa yhteistoiminnan Yhdysvalloissa käytetyn TDMA-matkapuhelinstandardin kanssa. EGPRS-puhelimessa puhelut hoidetaan TDMA-verkon kautta ja datan siirto GPRS-verkon kautta. EGPRS operoi GSM850 ja GSM1900 taajuusalueilla. EGPRS:n merkittävimpiä uusia ominaisuuksia ovat modulointimenetelmä EDGE ja kompaktit kontrollikanavat. Uudella modulointimenetelmällä saavutetaan kolminkertainen tiedonsiirtonopeus vanhaan modulointimenetelmään verrattuna. Kompaktien kontrollikanavien avulla voidaan tukiaseman taajuuskaistan tarvetta pienentää huomattavasti. Tukiasema voi käyttää vanhaa ja uutta modulointimenetelmää yhtä aikaa. EGPRS-verkko voi sisältää sekä kompakteja että normaaleja tukiasemia.
Resumo:
This work describes different possibilities of protection and control system improvement of primary distribution substation. The status of condition and main problems of power networks from reliability point of view in Russia are described. This work studies technologies used today in Russia for protection of distribution networks with their disadvantages. Majority of medium voltage networks (6-35 kV) has isolated network point. There is still no any protection available on the market which allows to estimate distance to fault in case of earth fault. The thesis analyses methods of earth fault distance calculation. On the basis of computer simulation the influence of various factors on calculation accuracy is studied. The practical implementation of the method presupposes usage of digital relay. Application of digital relay is accompanied by numerous opportunities which are described in this work. Also advantages of system implemented on the basis of IEC 61850 standard are examined. Finally, suitability of modern digital relays from GOST standard point of view is analyzed.
Resumo:
The fight against doping in sports has been governed since 1999 by the World Anti-Doping Agency (WADA), an independent institution behind the implementation of the World Anti-Doping Code (Code). The intent of the Code is to protect clean athletes through the harmonization of anti-doping programs at the international level with special attention to detection, deterrence and prevention of doping.1 A new version of the Code came into force on January 1st 2015, introducing, among other improvements, longer periods of sanctioning for athletes (up to four years) and measures to strengthen the role of anti-doping investigations and intelligence. To ensure optimal harmonization, five International Standards covering different technical aspects of the Code are also currently in force: the List of Prohibited Substances and Methods (List), Testing and Investigations, Laboratories, Therapeutic Use Exemptions (TUE) and Protection of Privacy and Personal Information. Adherence to these standards is mandatory for all anti-doping stakeholders to be compliant with the Code. Among these documents, the eighth version of International Standard for Laboratories (ISL), which also came into effect on January 1st 2015, includes regulations for WADA and ISO/IEC 17025 accreditations and their application for urine and blood sample analysis by anti-doping laboratories.2 Specific requirements are also described in several Technical Documents or Guidelines in which various topics are highlighted such as the identification criteria for gas chromatography (GC) and liquid chromatography (LC) coupled to mass spectrometry (MS) techniques (IDCR), measurements and reporting of endogenous androgenic anabolic agents (EAAS) and analytical requirements for the Athlete Biological Passport (ABP).
Resumo:
An experiment conducted in the field the action of mancozeb, a fungicide of multi-site action was tested, to control soybean rust caused by Phakopsora pachyrhizi. Its performance was compared to that of the mixture cyproconazole (DMI) + azoxystrobin (QoI). The soybean cultivar NA 7337 RR was used with a population of 400,000 plants/ha cultivated in 20m2 plots. Treatments consisted of mancozeb levels (1.5 and 2.0 kg/ha) applied four, six and eight times. The DMI + QoI mixture was applied three times at 0.3 L/ha + Nimbus. Rust severity was assessed six times in the plots and data were integrated as the area under the disease progress curve (AUDPC). The plots were harvested and grain yield was expressed as kg/ha. Data on AUDPC and yield were subjected to analysis of variance and means compared according to Turkey's test (p = 0.005). Treatments with mancozeb were superior to DMI + QoI mixture both for rust control and grain yield. Four applications of 2.0 k/ha mancozeb were more efficient than three applications of the mixture used as standard. Mancozeb has the potential to be added to fungicide mixtures in the establishment of soybean rust anti-resistance strategy.
Resumo:
The implementation of local geodetic networks for georeferencing of rural properties has become a requirement after publication of the Georeferencing Technical Standard by INCRA. According to this standard, the maximum distance of baselines to GNSS L1 receivers is of 20 km. Besides the length of the baseline, the geometry and the number of geodetic control stations are other factors to be considered in the implementation of geodetic networks. Thus, this research aimed to examine the influence of baseline lengths higher than the regulated limit of 20 km, the geometry and the number of control stations on quality of local geodetic networks for georeferencing, and also to demonstrate the importance of using specific tests to evaluate the solution of ambiguities and on the quality of the adjustment. The results indicated that the increasing number of control stations has improved the quality of the network, the geometry has not influenced on the quality and the baseline length has influenced on the quality; however, lengths higher than 20 km has not interrupted the implementation, with GPS L1 receiver, of the local geodetic network for the purpose of georeferencing. Also, the use of different statistical tests, both for the evaluation of the resolution of ambiguities and for the adjustment, have enabled greater clearness in analyzing the results, which allow that unsuitable observations may be eliminated.
Resumo:
The current study used statistical methods of quality control to evaluate the performance of a sewage treatment station. The concerned station is located in Cascavel city, Paraná State. The evaluated parameters were hydrogenionic potential, settleable solids, total suspended solids, chemical oxygen demand and biochemical oxygen demand in five days. Statistical analysis was performed through Shewhart control charts and process capability ratio. According to Shewhart charts, only the BOD(5.20) variable was under statistical control. Through capability ratios, we observed that except for pH the sewage treatment station is not capable to produce effluents under characteristics that fulfill specifications or standard launching required by environmental legislation.
Resumo:
The objective of this master’s thesis is to investigate the loss behavior of three-level ANPC inverter and compare it with conventional NPC inverter. The both inverters are controlled with mature space vector modulation strategy. In order to provide the comparison both accurate and detailed enough NPC and ANPC simulation models should be obtained. The similar control model of SVM is utilized for both NPC and ANPC inverter models. The principles of control algorithms, the structure and description of models are clarified. The power loss calculation model is based on practical calculation approaches with certain assumptions. The comparison between NPC and ANPC topologies is presented based on results obtained for each semiconductor device, their switching and conduction losses and efficiency of the inverters. Alternative switching states of ANPC topology allow distributing losses among the switches more evenly, than in NPC inverter. Obviously, the losses of a switching device depend on its position in the topology. Losses distribution among the components in ANPC topology allows reducing the stress on certain switches, thus losses are equally distributed among the semiconductors, however the efficiency of the inverters is the same. As a new contribution to earlier studies, the obtained models of SVM control, NPC and ANPC inverters have been built. Thus, this thesis can be used in further more complicated modelling of full-power converters for modern multi-megawatt wind energy conversion systems.