980 resultados para root canal filling materials


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption) that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm). The apparent tooth length (APTL) was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0), whereas the actual tooth length (ACTL) was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson’s correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study is to evaluate the measurement accuracy of endodontic files obtained by digital and conventional radiographies in primary teeth. Kerr and Hedströen files (# 20), with the reference as the apparent length of tooth, were inserted in the root canal of 18 extracted primary teeth, which were x-rayed by digital and conventional techniques. Measurements from a reference point to the apical end were carried out by an experienced operator twice in a week. An electronic ruler was used for the digital method and a caliper was used for the conventional method. The data were subjected to Pearson correlation test and Student´s t test (p = 0.05). The correlation between the first and the second measurements was r = 0.99, regardless the type of file and method. Comparing the measurements within the methods, the agreement was r = 0.96 for Kerr and r = 0.95 for Hedströen files. The values of length files in the digital radiographies were statistically lower than that obtained in the conventional radiographies (p = 0.02). However, the values obtained by the two methods were statistically similar to real length of teeth for Kerr files (p = 0.29) and for Hedströen files (p = 0.18). The digital radiography was a more trustful method to obtain the lengths of endodontic files.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The relationship of Orthodontics and Endodontics is being clarified with the development of evidence-based dentistry. However, few studies have reported the repair of periapical lesions with orthodontic treatment. Therefore, the aim of this study was to evaluate the available evidence on periapical repair of endodontically treated teeth during orthodontic movement. The strategy used was the electronic search with keywords and criteria including studies published up to July 2011. It was also carried out qualitative assessment of the articles methodology. Although a significant number of studies have reported this topic, only two filled the criteria for inclusion in this systematic review. The results obtained in the literature suggest that orthodontic treatment should be interrupted to perform endodontic treatment. During this therapy, the use of root canal dressing based on calcium hydroxide for at least 14 days, and sealer with adequate biological property are indicated. After this phase, orthodontic movement of the endodontically treated teeth can be resumed without waiting period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nickel-titanium rotatory systems should remove dentin during the root canal preparation to promote the enlargement and tapered shape with continuously narrowing towards the apex. Objective: The aim of this study was to analyze the cutting ability of three NiTi rotatory systems (n = 12): ProTaper (group 1), Mtwo (group 2), and K3 (group 3). Material and methods: Thirty six maxillary molar teeth were weighted on an analytical balance before and after the rotatory preparation of the mesio-buccal root canal. Data was statistically analyzed by ANOVA and Tukey s test with a significance level of 5%. Results: The results revealed the following mass differences (g) before and after the root canal preparation: ProTaper (group 1 – 0.0159 ± 0.004), Mtwo (group 2 – 0.0125 ± 0.002), and K3 (group 3 – 0.007 ± 0.003). Conclusion: ProTaper showed the highest cutting ability among the three tested nickel-titanium rotatory systems followed by Mtwo and K3.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this review was reporting an overview about the properties of two irrigating solutions, solution of sodium hypochlorite and chlorhexidine, used in the treatment of root canals. A solution must submit irrigating antimicrobial action, dissolve waste tissue, promote wetting to facilitate the instrumentation, and present biocompatibility with the adjacent tissues. The sodium hypochlorite used in different concentrations has been the solution of choice among professionals by presenting antimicrobial action and act as a solvent tissue. However, today, chlorhexidine has been widely used as an irrigating solution due to specific properties that enable its use, such as substantivity, antimicrobial effectiveness, and low toxicity. Thus the solution of chlorhexidine with different concentrations is presented as an alternative to irrigating solution for the treatment of root canals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The irrigation of root canals aims to their cleaning and disinfection, improving endodontic treatment success. OBJECTIVE: To investigate the influence of the diameter and type of irrigation needle and the root canal enlargement on the mechanical efficacy of endodontic irrigation. MATERIAL AND METHODS: Twelve human single-rooted mandibular incisors were used. During some instrumentation stages (enlargement by #20, #30, and #40 K file), root canals were filled with radiographic contrast solution mixed to propyleneglycol and zinc oxide. Needles with different diameters and designs were employed: G1 – 23G and lateral opening; G2 – 22G and apical opening; G3 – 30G and lateral opening; G4 – 30G and apical opening. The needles were inserted up to resistance, with 1 mm step-back to avoid root canal obliteration. The irrigation was performed with 2 mL of distilled water. Before and after irrigation/aspiration, teeth were radiographed at bucco-lingual and mesiodistal direction, using a digital radiographic system. Then, root canal areas, before (filled by contrast solution) and after irrigation (remnant of contrast solution), were submitted to image subtraction with Adobe Photoshop CS4 software. Subsequently, the areas were measured by Image Tool 3.0 software, allowing the obtaining of the cleaning percentage for each modality. Data were analysed by using Anova and Tukey's test. The level of significance was set at P < 0.05. RESULTS: For all root canal enlargements, 30G needles (G3 e G4) presented a better cleaning efficacy. In all groups, higher cleaning efficacy percentage was observed at #30 and #40 K file enlargement. CONCLUSION: Regardless their design, thinner needles were more effective; a better cleaning efficacy occurred in more enlarged root canals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The restoration of endodontically treated teeth is one of the most challenging situations of the dentist`s clinical practice, because it involves procedures related to several areas, such as Endodontics, Operative Dentistry, and Prosthetics. These restorations aim to replace the structures lost during endodontic surgery and access to both the pulp chamber and root canal system during the instrumentation, as well as the removal of the carious tissue and temporary restorations. It is also important to remember that the prognosis of endodontically treated teeth depends not only on endodontic treatment success itself, but also on the amount of remnant tooth tissue and the definitive restoration that will be placed onto the dental element.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the presence of residues of sodium hypo-chlorite gel, chlorhexidine gel, and EDTA gel on dentina l walls after canal preparat ion throughchemical SEM- elemental chemical microanal ys is (EDS) analysis. Forty-eight single-rootedteeth were selected. They had their crowns sectioned and were instrumented with a reciprocat-ing system. The canals were irrigated with 5 mL of saline solution during root canal preparation.After instrumentation, the root canals were irrigated with 3 mL 17% EDTA followed by 1 min ofultrasonic passive activation (33 20 sec) to remove the smear layer, and then irrigated with3 mL of saline solution. The specimens were randomized into three groups (n 5 12) accord ing tothe chemical substance that filled the root canal for 30 min: GI: 5.5% sodium hypochlorite gel;GII: 2% chlorhexidine gel; GIII: 24% EDTA gel; Negative c ontrol group: no substance was used.Then, the root canals were irrigated with 6 mL of saline solution followed by 1 min of ultrasonicpassive activation (33 20 sec). After ultrasonic activation , the canals were irrigated with 2 mLsaline. The roots were sect ioned, and the perce ntage of each chemical element present in thesamples was analyzed through chemi cal SEM-EDS microanalysis. All expe rimental groupsshowed a significantly higher percentage of chemical elements (Na and/or Cl) than the controlgroup (P < 0.03). This in vitro study has shown that, regardless of chemical solutions used evenafter the final irrigation protocol, chemical residues of d ifferent substances remained attached tothe r oot c anal wa lls. Microsc. Res. Tech. 78:495–49 9, 2015.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Lateral condensation effectiveness may be influenced by the gutta-percha and finger spreader taper used during root canal obturation. Objective: To evaluate the penetration ability of finger spreader into simulated root canals prepared using MTwo rotary system and filled with different gutta-percha and finger spreader tapers. Material and methods: Resin blocks with curved root canals had the apical diameter enlarged up to #25.06 and distributed into groups (n = 6) according to the gutta-percha taper (#25.02, #25.04, and #25.06) and the finger spreader (#30 and #35 NiTi, and stainless steel B) used to perform cold lateral condensation. After applying a load of 1.5 Kg over the finger spreaders’ head, the distance between the finger spread tip and the apical limit of the root canal preparation were obtained. The data were submitted to Anova and Tukey-Krammer’s test, with 5% of significance. Results: The gutta-percha cones with 0.02 taper enabled higher finger spreader penetration when compared to 0.04 and 0.06 tapers (p < 0.05), which were similar between each other (p > 0.05), regardless of the type and diameter of the finger spreader used. When different finger spreaders were compared among themselves, stainless steel B showed higher penetration ability (p < 0.05). Conclusion: It was concluded that the stainless-steel finger spreaders showed superior penetration ability and gutta-percha with lower tapers enabled a more effective lateral condensation at the apical third.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to develop, implement and evaluate the performance of a new type of bioreactor for anaerobic treatment of wastewater using different filling materials like trickling filters post-reactor. This bioreactor has mixed characteristics of the UASB reactors and horizontal flow from the point of view of removal of BOD (Biochemical Oxygen Demand) ssed (settled solids), TS (Total Solids), SS (Suspended Solid), SD (Dissolved Solids) and turbidity. The experimental model consists of a bioreactor with a volume of 12 m³, 2/3 filled by fluidized bed and 1/3 for fixed. The fluidized bed is made of polystyrene plates used as a system percolation and compartmentalized trickling filters, where each compartment was filled with a support medium with different characteristics (gravel number 4, plastic rings of polystyrene, PET and HDPE) . In addition, the output of a filter system was installed three entries filled with activated carbon. The bioreactor was installed in private residence in the city of Igarapava-SP (20° 02'40.18"S and 47° 45'01.36" W). The system was highly efficient as the removal of organic contaminant load 92% on average reducing the BOD, a significant result when compared to other anaerobic systems. For the other parameters, the mean reduction was 96% for turbidity, 99% ssed, 67.5% ST, 57% SD and 88% of SS. As for its operation the system was capable of operating in continuous flow without the need for maintenance during the entire period of evaluation and without energy, as it operates taking advantage of the natural slope of the terrain where it is installed. The environmental impacts were minimized due to the preservation of local vegetation allowing the ecosystem to remain unchanged beyond the prototype was completely sealed preventing exhalation of odors and therefore not causing inconvenience to neighboring populations. Given these facts it was concluded that the prototype is shown to be highly feasible deployed as a new alternative for treatment of sewage in rural and urban settings (individual homes, condos, farms, ranches, etc.) Due to ease of design and operability, and sustainability at all stages of execution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Antibiotic-containing polymer-based nanofibers (hereafter referred to as scaffolds) have demonstrated great potential for their use in regenerative endodontics from both an antimicrobial and cytocompatibility perspective. This study sought to evaluate in vitro the effects of ciprofloxacin (CIP)-containing polymer scaffolds against Enterococcus faecalis biofilms. Methods: Human mandibular incisors were longitudinally sectioned to prepare radicular dentin specimens. Sterile dentin specimens were distributed in 24-well plates and inoculated with E. faecalisfor biofilm formation. Infected dentin specimens were exposed to 3 groups of scaffolds, namely polydioxanone (PDS) (control), PDS + 5 wt% CIP, and PDS + 25 wt% CIP for 2 days. Colony-forming units (CFU/mL) (n = 10) and scanning electron microscopy (SEM) (n -= 2) were performed to quantitatively and qualitatively assess the antimicrobial effectiveness, respectively. Results: PDS scaffold containing CIP at 25 wt% showed maximum bacteria elimination with no microbial growth, differing statistically (P < .05) from the control (PDS) and from PDS scaffold containing CIP at 5 wt%. Statistical differences (P < .05) were also seen for the CFU/mL data between pure PDS (5.92-6.02 log CFU/mL) and the PDS scaffold containing CIP at 5 wt% (5.39 5.87 log CFU/mL). SEM images revealed a greater concentration of bacteria on the middle third of the dentin specimen. after 5 days of biofilm formation. On scaffold exposures, SEM images showed similar results when compared with the CFU/mL data. Dentin specimens exposed to PDS + 25 wt% CIP scaffolds displayed a practically bacteria-free surface. Conclusions: On the basis of the data presented, newly developed antibiotic-containing electrospun scaffolds hold promise as an intracanal medicament to eliminate biofilm/infection before regenerative procedures.