953 resultados para road safety application


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose The accuracy, efficiency, and efficacy of four commonly recommended medication safety assessment methodologies were systematically reviewed. Methods Medical literature databases were systematically searched for any comparative study conducted between January 2000 and October 2009 in which at least two of the four methodologies—incident report review, direct observation, chart review, and trigger tool—were compared with one another. Any study that compared two or more methodologies for quantitative accuracy (adequacy of the assessment of medication errors and adverse drug events) efficiency (effort and cost), and efficacy and that provided numerical data was included in the analysis. Results Twenty-eight studies were included in this review. Of these, 22 compared two of the methodologies, and 6 compared three methods. Direct observation identified the greatest number of reports of drug-related problems (DRPs), while incident report review identified the fewest. However, incident report review generally showed a higher specificity compared to the other methods and most effectively captured severe DRPs. In contrast, the sensitivity of incident report review was lower when compared with trigger tool. While trigger tool was the least labor-intensive of the four methodologies, incident report review appeared to be the least expensive, but only when linked with concomitant automated reporting systems and targeted follow-up. Conclusion All four medication safety assessment techniques—incident report review, chart review, direct observation, and trigger tool—have different strengths and weaknesses. Overlap between different methods in identifying DRPs is minimal. While trigger tool appeared to be the most effective and labor-efficient method, incident report review best identified high-severity DRPs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Acute BAO is a devastating neurological condition associated with a poor clinical outcome and a high mortality rate. Recanalization has been identified as a major prognostic factor for good outcome in BAO. Mechanical thrombectomy using retrievable stents is an emerging treatment option for acute stroke. First clinical trials using stent retrievers have shown promising high recanalization rates. However, these studies mainly included large artery occlusions in the anterior circulation with only a few or single cases of BAO. Therefore, the purpose of this study was to evaluate technical feasibility, safety, and efficacy of mechanical thrombectomy using retrievable stent in the treatment of acute BAO.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Visual hallucinations (VH) are a common experience and can be distressing and disabling, particularly for people suffering from psychotic illness. However, not everyone with visual hallucinations reports the experience to be distressing. Models of VH propose that appraisals of VH as a threat to wellbeing and the use of safety seeking behaviours help maintain the distress.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To assess frequency and severity of patient safety incidents in primary care. Study Design: Cross-sectional survey of health-care professionals in Swiss primary care offices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A systematic literature review was conducted to assess the effectiveness of, compliance with, and critical factors for the implementation of safety checklists in surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Foreign-language (FL) patients are at increased risk for adverse drug events. Evidence regarding communication barriers and the safety of pharmaceutical care of FL patients in European countries is scarce despite large migrant populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Medical errors and adverse events are a serious threat to patients worldwide. In recent years methodologically sound studies have demonstrated that interventions exist, can be implemented and can have sustainable, measurable positive effects on patient safety. Nonetheless, system-wide progress and adoption of safety practices is slow and evidence of improvements on the organisational and systems level is scarce and ambiguous. This paper reports on the Swiss Patient Safety Conference in 2011 and addresses emerging issues for patient safety and future challenges.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients can contribute to the improvement in patient safety. They are usually vigilant observers of the care they receive and can provide information about adverse events and safety-related processes. In addition, they can help to prevent errors by active engagement in safety. This potential for involvement in error prevention is increasingly acknowledged internationally. Educational material has been developed and can be used to instruct and motivate patients to monitor care for failures and errors and communicate their observations towards health care workers. Preliminary research suggests that this approach can be successful in improving patient safety.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and purpose Intra-arterial treatment (IAT) is effective when performed within 6 h of symptom onset in selected stroke patients (‘T < 6H’). Its safety and efficacy is unclear when the patient has had symptoms for more than 6 h (‘T > 6H’) or for an unknown time (unclear-onset stroke, UOS), or woke up with a stroke (wake-up stroke, WUS). In this study we compared the safety of IAT in these four patient groups. Methods Eight-hundred and fifty-nine patients treated with IAT were enrolled. The main outcome parameters were clinical outcome [excellent: modified Rankin Scale (mRS) 0 or 1; or favorable: mRS 0–2] or mortality 3 months after treatment. Further outcome parameters were the rates of vessel recanalization, and cerebral and systemic hemorrhage. Results Six-hundred and fifty-four patients were treated before (T < 6H) and 205 after 6 h or an unknown time (128 T > 6H, 55 WUS and 22 UOS). NIHSS scores were higher in UOS patients than in T < 6H patients, vertebrobasilar occlusion was more common in T > 6H and UOS patients, and middle cerebral artery occlusions less common in T > 6H than in T < 6H patients. Other baseline characteristics were similar. There was no significant difference in clinical outcome and the rate of hemorrhage in multivariable regression analysis. Conclusions Clinical outcome of our four groups of patients was similar with no increase of hemorrhage rates in patients treated after awakening, after an unknown time or more than 6 h. Our preliminary data suggest that treatment of such patients may be performed safely. If confirmed in randomized trials, this would have major clinical implications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis presents a metric for assessing the commonality and differentiation of packaging-family planning with application to medical labels along with supporting background research and findings. Consumable products such as medications rely on the package or label to represent the contents. Package confusion has been widely recognized as a major problem for both over-the-counter and pharmacy-dispensed medications with potentially lethal consequences. It is critical to identify a medication as a member of a product family and differentiate its contributing elements based on visual features on the package or label to avoid consumer confusion and reduce dispensing errors. Indices that indicate degrees of commonality and differentiation of features in consumer products such as batteries, light bulbs, handles, etc for platforms have been shown to benefit development of engineered product families [6]. It is possible to take a similar approach for visual features in packaging such as typography, shape/form, imagery and color to benefit packaging-family development. This thesis establishes a commonality differentiation index for prominence of visual features on over-the-counter and pharmacy-dispensed medications based on occurrence, size, and location of features. It provides a quantitative measure to assist package designers in evaluating alternatives to satisfy strategic goals and improve safety. The index is demonstrated with several medications that have been identified by the Institute for Safe Medication Practice as commonly confused.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The Health Technology Assessment report on effectiveness, cost-effectiveness and appropriateness of homeopathy was compiled on behalf of the Swiss Federal Office for Public Health (BAG) within the framework of the 'Program of Evaluation of Complementary Medicine (PEK)'. Materials and Methods: Databases accessible by Internet were systematically searched, complemented by manual search and contacts with experts, and evaluated according to internal and external validity criteria. Results: Many high-quality investigations of pre-clinical basic research proved homeopathic high-potencies inducing regulative and specific changes in cells or living organisms. 20 of 22 systematic reviews detected at least a trend in favor of homeopathy. In our estimation 5 studies yielded results indicating clear evidence for homeopathic therapy. The evaluation of 29 studies in the domain 'Upper Respiratory Tract Infections/Allergic Reactions' showed a positive overall result in favor of homeopathy. 6 out of 7 controlled studies were at least equivalent to conventional medical interventions. 8 out of 16 placebocontrolled studies were significant in favor of homeopathy. Swiss regulations grant a high degree of safety due to product and training requirements for homeopathic physicians. Applied properly, classical homeopathy has few side-effects and the use of high-potencies is free of toxic effects. A general health-economic statement about homeopathy cannot be made from the available data. Conclusion: Taking internal and external validity criteria into account, effectiveness of homeopathy can be supported by clinical evidence and professional and adequate application be regarded as safe. Reliable statements of cost-effectiveness are not available at the moment. External and model validity will have to be taken more strongly into consideration in future studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aerosols are the most promising non-injectable method of measles vaccination studied so far and their efficacy is thought to be comparable to injected vaccine. We conducted a systematic review up to May 2006 to examine the immunogenicity and safety of aerosolized measles vaccine (Edmonston-Zagreb or Schwarz strains) 1 month or more after vaccination. Where possible we estimated pooled serological response rates and odds ratios (with 95% confidence intervals, CI) comparing aerosolized and subcutaneous vaccines in children in three age groups and adults. We included seven randomized trials, four non-randomized trials and six uncontrolled studies providing serological outcome data on 2887 individuals. In children below 10 months, the studies were heterogeneous. In four comparative studies, seroconversion rates were lower with aerosolized than with subcutaneous vaccine and in two of these the difference was unlikely to be due to chance. In children 10-36 months, the pooled seroconversion rate with aerosolized vaccine was 93.5% (89.4-97.7%) and 97.1% (92.4-100%) with subcutaneous vaccine (odds ratio 0.27, 0.04-1.62). In 5-15-year olds the studies were heterogeneous. In all comparative studies aerosolized vaccine was more immunogenic than subcutaneous. Reported side effects were mild. Aerosolized measles vaccine appears to be equally or more immunogenic than subcutaneous vaccine in children aged 10 months and older. Large randomized trials are needed to establish the efficacy and safety of aerosolized measles vaccine as primary and booster doses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Drug-eluting stents (DESs) effectively reduce angiographic restenosis and the clinical need for repeat revascularization procedures as compared with bare-metal stents. Widely publicized concerns arose recently about the incidence of late and very late stent thrombosis with the use of first-generation DESs. Recent systematic reviews and large-scale registry studies demonstrated similar rates of overall mortality and myocardial infarction for patients treated with either DESs or bare-metal stents during long-term follow-up. Careful selection of stent type according to patient and lesion characteristics as well as monitoring of adherence to dual antiplatelet therapy could maximize the therapeutic potential of these devices. The purpose of the present Review is to provide the reader with an overview of the benefits and risks of first-generation DESs that could help physicians select the most appropriate stent type for each patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Pelvic x-ray is a routine part of the primary survey of polytraumatized patients according to Advanced Trauma Life Support (ATLS) guidelines. However, pelvic CT is the gold standard imaging technique in the diagnosis of pelvic fractures. This study was conducted to confirm the safety of a modified ATLS algorithm omitting pelvic x-ray in hemodynamically stable polytraumatized patients with clinically stable pelvis in favour of later pelvic examination by CT scan. METHODS: We conducted a retrospective analysis of all polytraumatized patients in our emergency room between 01.07.2004 and 31.01.2006. Inclusion criteria were blunt abdominal trauma, initial hemodynamic stability and a stable pelvis on clinical examination. We excluded patients requiring immediate intervention because of hemodynamic instability. RESULTS: We reviewed the records of n = 452 polytraumatized patients, of which n = 91 fulfilled inclusion criteria (56% male, mean age = 45 years). The mechanism of trauma included 43% road traffic accidents, 47% falls. In 68/91 (75%) patients, both a pelvic x-ray and a CT examination were performed; the remainder had only pelvic CT. In 6/68 (9%) patients, pelvic fracture was diagnosed by pelvic x-ray. None of these 6 patients was found having a false positive pelvic x-ray, i.e. there was no fracture on pelvic CT scan. In 3/68 (4%) cases a fracture was missed in the pelvic x-ray, but confirmed on CT (false negative on x-ray). None of the diagnosed fractures needed an immediate therapeutic intervention. 5 (56%) were classified type A fractures, and another 4 (44%) B 2.1 in computed tomography (AO classification). One A 2.1 fracture was found in a clinically stable patient who only received CT scan (1/23). CONCLUSION: While pelvic x-ray is an integral part of ATLS assessment, this retrospective study suggests that in hemodynamically stable patients with clinically stable pevis, its sensitivity is only 67% and it may safely be omitted in favor of a pelvic CT examination if such is planned in adjunct assessment and available. The results support the safety and utility of our modified ATLS algorithm. A randomized controlled trial using the algorithm can safely be conducted to confirm the results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As an important Civil Engineering material, asphalt concrete (AC) is commonly used to build road surfaces, airports, and parking lots. With traditional laboratory tests and theoretical equations, it is a challenge to fully understand such a random composite material. Based on the discrete element method (DEM), this research seeks to develop and implement computer models as research approaches for improving understandings of AC microstructure-based mechanics. In this research, three categories of approaches were developed or employed to simulate microstructures of AC materials, namely the randomly-generated models, the idealized models, and image-based models. The image-based models were recommended for accurately predicting AC performance, while the other models were recommended as research tools to obtain deep insight into the AC microstructure-based mechanics. A viscoelastic micromechanical model was developed to capture viscoelastic interactions within the AC microstructure. Four types of constitutive models were built to address the four categories of interactions within an AC specimen. Each of the constitutive models consists of three parts which represent three different interaction behaviors: a stiffness model (force-displace relation), a bonding model (shear and tensile strengths), and a slip model (frictional property). Three techniques were developed to reduce the computational time for AC viscoelastic simulations. It was found that the computational time was significantly reduced to days or hours from years or months for typical three-dimensional models. Dynamic modulus and creep stiffness tests were simulated and methodologies were developed to determine the viscoelastic parameters. It was found that the DE models could successfully predict dynamic modulus, phase angles, and creep stiffness in a wide range of frequencies, temperatures, and time spans. Mineral aggregate morphology characteristics (sphericity, orientation, and angularity) were studied to investigate their impacts on AC creep stiffness. It was found that aggregate characteristics significantly impact creep stiffness. Pavement responses and pavement-vehicle interactions were investigated by simulating pavement sections under a rolling wheel. It was found that wheel acceleration, steadily moving, and deceleration significantly impact contact forces. Additionally, summary and recommendations were provided in the last chapter and part of computer programming codes wree provided in the appendixes.