995 resultados para lymphatic vessel


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Visualization of coronary blood flow by means of a slice-selective inversion pre-pulse in concert with bright-blood coronary MRA. MATERIALS AND METHODS: Coronary magnetic resonance angiography (MRA) of the right coronary artery (RCA) was performed in eight healthy adult subjects on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Medical Systems, Best, NL) using a free-breathing navigator-gated and cardiac-triggered 3D steady-state free-precession (SSFP) sequence with radial k-space sampling. Imaging was performed with and without a slice-selective inversion pre-pulse, which was positioned along the main axis of the coronary artery but perpendicular to the imaging volume. Objective image quality parameters such as SNR, CNR, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: In contrast to conventional bright-blood 3D coronary MRA, the selective inversion pre-pulse provided a direct measure of coronary blood flow. In addition, CNR between the RCA and right ventricular blood pool was increased and the vessels had a tendency towards better delineation. Blood SNR and CNR between right coronary blood and epicardial fat were comparable in both sequences. CONCLUSION: The combination of a free-breathing navigator-gated and cardiac-triggered 3D SSFP sequence with a slice-selective inversion pre-pulse allows for direct and directional visualization of coronary blood flow with the additional benefit of improved contrast between coronary and right ventricular blood pool.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite advances in both prevention and treatment, cardiovascular disease remains the leading cause of morbidity and mortality in the United States. The current gold standard for the diagnosis of coronary artery disease is the x-ray coronary angiogram, which is both costly and associated with a small risk of morbidity. More than 1 million Americans are referred for this test annually, and despite the availability of numerous noninvasive tests to identify patients with coronary artery disease, > or =35% of patients referred for this test are found not to have disease. It therefore would be beneficial to use a noninvasive test to allow the presence of coronary atherosclerosis to be determined directly. Coronary magnetic resonance angiography, a technique that is aimed at establishing a noninvasive test for the assessment of significant coronary stenoses, obviates the risks of patient exposure to radiation of x-ray angiography and therefore represents a major step forward in diagnostic cardiology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lymphocoele is a rare and little known complication with only a handful of reports available. We report two cases of lymphocoele after anterior lumbar surgery that have occurred in two different centres and discuss diagnosis and management options. The first case is that of a 53-year-old male patient undergoing two level anterior lumbar interbody fusion (ALIF) for disabling back pain due to disc degeneration in the context of an old spondylodiscitis. He developed a large fluid mass postoperatively. Fluid levels of creatinin were low and intravenous urography ruled out a urinoma suggesting the diagnosis of a lymphocoele. Following two unsuccessful drainage attempts he underwent a laparoscopic marsupialization. The second case was that of a 32-year-old female patient developing a large fluid mass following a L5 corpectomy for a burst fracture. She was treated successfully with insertion of a vacuum drain during 7 days. Lymphocoele is a rare complication but should be suspected if fluid collects postoperatively following anterior lumbar spine procedures. Chemical analysis of the fluid can help in diagnosis. Modern treatment consists of laparoscopic marsupialization. Lymph vessel anatomy should be borne in mind while exposing the anterior lumbar spine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Magnetic resonance imaging is a rapidly developing modality in cardiology. It offers an excellent image definition and a large field of view, allowing a more accurate morphological assessment of cardiac malformations. Due to its unique versatility and its ability to provide myocardial tissue characterization, cardiac magnetic resonance (CMR) is now recognized as a central imaging modality for a wide range of congenital heart diseases, including assessment of post-surgical cardiac anatomy, quantification of valvular disease and detection of myocardial ischemia. CMR provides useful diagnostic information without any radiation exposure, and improves the global management of patients with congenital heart disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to evaluate the mid-term biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery. METHODS: Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. IOP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed. RESULTS: For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant. CONCLUSIONS: The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To investigate the impact of end-systolic imaging on quality of right coronary magnetic resonance angiography (MRA) in comparison to diastolic and to study the effect of RR interval variability on image quality. MATERIALS AND METHODS: The right coronary artery (RCA) of 10 normal volunteers was imaged at 3T using parallel imaging (sensitivity encoding [SENSE]). Navigator-gated three-dimensional (3D) gradient echo was used three times: 1) end-systolic short acquisition (SS): 35-msec window; 2) diastolic short (DS): middiastolic acquisition using 35-msec window; and 3) diastolic long (DL): 75-msec diastolic acquisition window. Vectorcardiogram (VCG) data was used to analyze RR variability. Vessel sharpness, length, and diameter were compared to each other and correlated with RR variability. Blinded qualitative image scores of the images were compared. RESULTS: Quantitative and qualitative parameters were not significantly different and showed no significant correlation with RR variability. CONCLUSION: Imaging the RCA at 3T during the end-systolic rest period using SENSE is possible without significant detrimental effect on image quality. Breaking away from the standard of imaging only during diastole can potentially improve image quality in tachycardic patients or used for simultaneous imaging during both periods in a single scan.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En la actualidad, la Armada española cuenta con un total de 103 buques (LOBA, 2009). Cada uno de ellos tiene una misión específica de acuerdo a sus características. Dicha misión condicionará la vida útil del navío. Cuando un buque es dado de baja, surgen las siguientes preguntas: ¿Qué hacer con ellos? ¿Tienen alguna utilidad? ¿Generan un impacto ambiental? En este proyecto, se presentan diferentes propuestas que tienen como finalidad obtener el mayor beneficio del recurso. Cada una de ellas buscará el máximo rédito en aspectos como la cohesión en el tejido social y la socio-economía de una zona determinada y la protección del medio marino junto al futuro de la pesca de arrastre en nuestro país. A lo largo del trabajo, se verá la dificultad de desguazar buques con gran eslora en nuestros astilleros, así como también los problemas administrativos y políticos a los que se enfrentan asociaciones y ayuntamientos que quieren adquirir un buque, para convertirlo en un museo o en un pecio, respectivamente. El objetivo principal es dar a conocer cuál es la situación, pero sin entrar a determinar qué opción sería mejor para cada tipo de navío.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The relationship between ingestion of microfilariae (mf), production of infective larvae (L3) and mf density in human blood has been suggested as an important determinant in the transmission dynamics of lymphatic filariasis. Here we assess the role of these factors in determining the competence of a natural vector Culex quinquefasciatus and a non vector Aedes aegypti to transmit Wuchereria bancrofti. Mosquitoes were infected via a membrane feeding procedure. Both mosquito species ingested more than the expected number of microfilariae (concentrating factor was 1.28 and 1.81 for Cx. quinquefasciatus and Ae. aegypti, respectively) but Cx. quinquefasciatus ingested around twice as many mf as Ae. aegypti because its larger blood meal size. Ae. aegypti showed a faster mf migration capacity compared to Cx. quinquefasciatus but did not allow parasite maturation under our experimental conditions. Similar proportions of melanized parasites were observed in Ae. aegypti (2.4%) and Cx. quinquefasciatus (2.1%). However, no relationship between rate of infection and melanization was observed. We conclude that in these conditions physiological factors governing parasite development in the thorax may be more important in limiting vectorial competence than the density of mf ingested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We compared cerebral blood flow velocity during anesthesia with sevoflurane and halothane in 23 children admitted for elective surgery (age, 0.4-9.7 yr; median age, 1.9 yr; ASA physical status I-II). Inhaled induction was performed in a randomized sequence with sevoflurane or halothane. Under steady-state conditions, cerebral blood flow velocity (systolic [V(s)], mean [V(mn)], and diastolic [VD]) were measured by a blinded investigator using transcranial pulsed Doppler ultrasonography. The anesthetic was then changed. CBFV measurements were repeated after washout of the first anesthetic and after steady-state of the second (equivalent minimal alveolar concentration to first anesthetic). The resistance index was calculated. VD and V(mn) were significantly lower during sevoflurane (V(mn) 1.35 m/s) than during halothane (V(mn) 1.50 m/s; P = 0.001), whereas V(s) was unchanged. The resistance index was lower during halothane (P < 0.001). Our results indicate lower vessel resistance and higher mean velocity during halothane than during sevoflurane. IMPLICATIONS: The mean cerebral blood flow velocity is significantly decreased in children during inhaled anesthesia with sevoflurane than during halothane. This might be relevant for the choice of anesthetic in children with risk of increased intracranial pressure, neurosurgery, or craniofacial osteotomies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inorganic phosphate (Pi) homeostasis in multi-cellular eukaryotes depends not only on Pi influx into cells, but also on Pi efflux. Examples in plants for which Pi efflux is crucial are transfer of Pi into the xylem of roots and release of Pi at the peri-arbuscular interface of mycorrhizal roots. Despite its importance, no protein has been identified that specifically mediates phosphate efflux either in animals or plants. The Arabidopsis thaliana PHO1 gene is expressed in roots, and was previously shown to be involved in long-distance transfer of Pi from the root to the shoot. Here we show that PHO1 over-expression in the shoot of A. thaliana led to a two- to threefold increase in shoot Pi content and a severe reduction in shoot growth. (31) P-NMR in vivo showed a normal initial distribution of intracellular Pi between the cytoplasm and the vacuole in leaves over-expressing PHO1, followed by a large efflux of Pi into the infiltration medium, leading to a rapid reduction of the vacuolar Pi pool. Furthermore, the Pi concentration in leaf xylem exudates from intact plants was more than 100-fold higher in PHO1 over-expressing plants compared to wild-type. Together, these results show that PHO1 over-expression in leaves leads to a dramatic efflux of Pi out of cells and into the xylem vessel, revealing a crucial role for PHO1 in Pi efflux.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to prospectively compare free-breathing navigator-gated cardiac-triggered three-dimensional steady-state free precession (SSFP) spin-labeling coronary magnetic resonance (MR) angiography performed by using Cartesian k-space sampling with that performed by using radial k-space sampling. A new dedicated placement of the two-dimensional selective labeling pulse and an individually adjusted labeling delay time approved by the institutional review board were used. In 14 volunteers (eight men, six women; mean age, 28.8 years) who gave informed consent, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, vessel length, and subjective image quality were investigated. Differences between groups were analyzed with nonparametric tests (Wilcoxon, Pearson chi2). Radial imaging, as compared with Cartesian imaging, resulted in a significant reduction in the severity of motion artifacts, as well as an increase in SNR (26.9 vs 12.0, P < .05) in the coronary arteries and CNR (23.1 vs 8.8, P < .05) between the coronary arteries and the myocardium. A tendency toward improved vessel sharpness and vessel length was also found with radial imaging. Radial SSFP imaging is a promising technique for spin-labeling coronary MR angiography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Chronic Conditions Hub is a website that brings together information on chronic health conditions. It allows you to easily access, manage and share relevant information resources. The Chronic Conditions Hub includes the Institute of Public Health in Ireland’s (IPH) estimates and forecasts of the number of people living with chronic conditions. On the Chronic Conditions Hub you will find: - A Briefing for each condition - Detailed technical documentation - Detailed national and sub-national data that can be downloaded or explored using online data tools - A prevalence tool that allows you to calculate prevalence figures for your population data A stroke happens when blood flow to a part of the brain is interrupted by a blocked or burst blood vessel. A lack of blood supply can damage brain cells and affect body functions. IPH has systematically estimated and forecast the prevalence of stroke on the island of Ireland.   Epidemiology Age, family history, diabetes, high blood pressure, high cholesterol, smoking, unhealthy diet, physical inactivity and alcohol are the main risk factors for stroke. The World Health Organization estimates that stroke and cerebrovascular disease is responsible for 10% of all world deaths and is the second most common cause of death worldwide. Cerebrovascular diseases (ICD 10 codes I60-I69) were responsible for 7.2% of all deaths in the Republic of Ireland in 2009 and for 8.6% of all deaths in Northern Ireland in 2010.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A stroke happens when blood flow to a part of the brain is interrupted by a blocked or burst blood vessel. A lack of blood supply can damage brain cells and affect body functions. IPH has systematically estimated and forecast the prevalence of stroke on the island of Ireland. This document details the methods used to calculate these estimates and forecasts. Technical documentation      

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Localized cutaneous leishmaniasis (LCL), known as "chiclero's ulcer" in southeast Mexico, was described by Seidelin in 1912. Since then, the sylvatic region of the Yucatan peninsula has been identified as an endemic focus of LCL. The purpose of the present work was to describe the clinical picture of LCL caused by Leishmania (Leishmania) mexicana in the Yucatan peninsula. A total of 136 cases of LCL, based on isolation and characterization of L. (L.) mexicana by isoenzymes and/or monoclonal antibodies, were selected. Some variability of clinical features regarding number, type, size, form, location and time of evolution of the lesions was observed. The most frequently observed presentation was a single, ulcerated, rounded small lesion, located on the ear, with an evolution time of less than three months, with neither cutaneous metastases nor lymphatic nor mucosal involvement. This picture corresponds to previous studies carried out in the same endemic area where an organism of the L. mexicana complex has been incriminated as a major aetiological agent of classical "chiclero's ulcer", confirming that in the Yucatan peninsula LCL due to L. (L.) mexicana when located on the pinna of the ear is a remarkable characteristic.