990 resultados para joint motion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hip joint replacement is 1 of the most successful surgical procedures of the last century and the number of replacements implanted is steadily growing. An infected hip arthroplasty is a disaster, it leads to patient suffering, surgeon's frustration and significant costs to the health system. The treatment of an infected hip replacement is challenging, healing rates can be low, functional results poor with decreased patient satisfaction. However, if a patient-adapted treatment of infected hip joints is used a success rate of above 90% can be obtained.Patient-adapted treatment is based on 5 important concepts: teamwork; understanding the biofilm; diagnostic accuracy; correct definition and classification of PJI; and patient-tailored treatment.This review presents a patient-adapted treatment strategy to prosthetic hip infection. It incorporates the best aspects of the single and staged surgical strategies and promotes the short interval philosophy for the 2-stage approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The kinematics of the anatomical shoulder are analysed and modelled as a parallel mechanism similar to a Stewart platform. A new method is proposed to describe the shoulder kinematics with minimal coordinates and solve the indeterminacy. The minimal coordinates are defined from bony landmarks and the scapulothoracic kinematic constraints. Independent from one another, they uniquely characterise the shoulder motion. A humanoid mechanism is then proposed with identical kinematic properties. It is then shown how minimal coordinates can be obtained for this mechanism and how the coordinates simplify both the motion-planning task and trajectory-tracking control. Lastly, the coordinates are also shown to have an application in the field of biomechanics where they can be used to model the scapulohumeral rhythm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we propose a method for prospective motion correction in MRI using a novel image navigator module, which is triggered by a free induction decay (FID) navigator. Only when motion occurs, the image navigator is run and new positional information is obtained through image registration. The image navigator was specifically designed to match the impact on the magnetization and the acoustic noise of the host sequence. This detection-correction scheme was implemented for an MP-RAGE sequence and 5 healthy volunteers were scanned at 3T while performing various head movements. The correction performance was demonstrated through automated brain segmentation and an image quality index whose results are sensitive to motion artifacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Els jugadors de futbol sotmesos a una reconstrucció de LCA es veuen afectats per dos vessants. La primera és a nivell funcional de l’articulació del genoll, entenent aquesta com la capacitat que presenta el genoll a suportar pes, generar força, realitzar moviments i mantenir-se estable durant la practica esportiva (Mattacola et. al., 2002). La segona és a nivell psicològic en seguretat amb un mateix i en seguretat a l’acció motriu (Brewer et. al., 1993). Aquesta recerca presenta un estudi sobre la funcionalitat i l’estat psicològic de deu jugadors de futbol amateur un cop ja han estat rehabilitats i readaptats a la practica esportiva. L’objectiu de l’estudi és conèixer la relació entre les respostes funcionals i subjectives. El procés s’ha dividit en tres fases, la primera ha estat la selecció del grup i realització del qüestionari de creació pròpia QSCFEG 2014 (que permet extreure el nivell de seguretat en l’acció motriu i el nivell de seguretat amb un mateix), la segona fase ha consistit en passar les quatre proves del HOP Test i mesurar els perímetres i l’amplitud de moviment de les extremitats inferiors (per mesurar l’índex de simetria de les extremitat inferior i veure el nivell funcional) i la última la recopilació de dades, anàlisi dels resultats i extracció de conclusions. A l’analitzar el grup s’ha comprovat que tots els subjectes presenten un nivell funcional superior al paràmetre mínim, que segon Barber et. al (1990) és del 85%. Tot i això, la gran majoria presenten mancances a nivell psicològic, ja que han demostrat una puntuació baixa en relació als mínims establerts als nivells de seguretat motriu (40 punts mínim) i seguretat amb un mateix (20 punts mínim).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

People performing actions together have a natural tendency to synchronize their behavior. Consistently, people doing a task together build internal representations not only of their actions and goals, but also of the other people performing the task. However, little is known about which are the behavioral mechanisms and the psychological factors affecting the subjective sensation of synchrony, or "connecting" with someone else. In this work, we sought to find which factors induce the subjective sensation of synchrony, combining motion capture data and psychological measures. Our results show that the subjective sensation of synchrony is affected by performance quality together with task category, and time. Psychological factors such as empathy and negative subjective affects also correlate with the subjective sensation of synchrony. However, when people estimate synchrony as seen from a third person perspective, their psychological factors do not affect the accuracy of the estimation. We suggest that to feel this sensation it is necessary to, first, have a good joint performance and, second, to assume the existence of an attention monitoring mechanism that reports that the attention of both participants (self and other) is focused on the task.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Compensation for respiratory motion is needed while administering radiotherapy (RT) to tumors that are moving with respiration to reduce the amount of irradiated normal tissues and potentially decrease radiation-induced collateral damages. The purpose of this study was to test a new ventilation system designed to induce apnea-like suppression of respiratory motion and allow long enough breath hold durations to deliver complex RT. MATERIAL AND METHODS: The High Frequency Percussive Ventilation system was initially tested in a series of 10 volunteers and found to be well tolerated, allowing a median breath hold duration of 11.6min (range 3.9-16.5min). An evaluation of this system was subsequently performed in 4 patients eligible for adjuvant breast 3D conformal RT, for lung stereotactic body RT (SBRT), lung volumetric modulated arc therapy (VMAT), and VMAT for palliative pleural metastases. RESULTS: When compared to free breathing (FB) and maximal inspiration (MI) gating, this Percussion Assisted RT (PART) offered favorable dose distribution profiles in 3 out of the 4 patients tested. PART was applied in these 3 patients with good tolerance, without breaks during the "beam on time period" throughout the overall courses of RT. The mean duration of the apnea-like breath hold that was necessary for delivering all the RT fractions was 7.61min (SD=2.3). CONCLUSIONS: This first clinical implementation of PART was found to be feasible, tolerable and offers new opportunities in the field of RT for suppressing respiratory motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objective: To evaluate the rectal volume influence on prostate motion during three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Materials and Methods: Fifty-one patients with prostate cancer underwent a series of three computed tomography scans including an initial planning scan and two subsequent scans during 3D-CRT. The organs of interest were outlined. The prostate contour was compared with the initial CT images considering the anterior, posterior, superior, inferior and lateral edges of the organ. Variations in the anterior limits and volume of the rectum were assessed and correlated with prostate motion in the anteroposterior direction. Results: The maximum range of prostate motion was observed in the superoinferior direction, followed by the anteroposterior direction. A significant correlation was observed between prostate motion and rectal volume variation ( p = 0.037). A baseline rectal volume superior to 70 cm3 had a significant influence on the prostate motion in the anteroposterior direction ( p = 0.045). Conclusion: The present study showed a significant interfraction motion of the prostate during 3D-CRT with greatest variations in the superoinferior and anteroposterior directions, and that a large rectal volume influences the prostate motion with a cutoff value of 70 cm3. Therefore, the treatment of patients with a rectal volume > 70 cm3 should be re-planned with appropriate rectal preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the thesis is to study the principles of the permanent magnet linear synchronous motor (PMLSM) and to develop a simulator model of direct force controlled PMLSM. The basic motor model is described by the traditional two-axis equations. The end effects, cogging force and friction model are also included into the final motor model. Direct thrust force control of PMLSM is described and modelled. The full system model is proven by comparison with the data provided by the motor manufacturer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the process of the integration of a real-time simulator environment with a motion platform and a haptic device as a part of the Kvalive project. Several programs running on two computers were made to control the different devices of the environment. User tests were made to obtain information of needed improvements to make the simulator more realistic. Also new ideas for improving the simulator and directions of further research were obtained with the help of this research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis introduces a real-time simulation environment based on the multibody simulation approach. The environment consists of components that are used in conventional product development, including computer aided drawing, visualization, dynamic simulation and finite element software architecture, data transfer and haptics. These components are combined to perform as a coupled system on one platform. The environment is used to simulate mobile and industrial machines at different stages of a product life time. Consequently, the demands of the simulated scenarios vary. In this thesis, a real-time simulation environment based on the multibody approach is used to study a reel mechanism of a paper machine and a gantry crane. These case systems are used to demonstrate the usability of the real-time simulation environment for fault detection purposes and in the context of a training simulator. In order to describe the dynamical performance of a mobile or industrial machine, the nonlinear equations of motion must be defined. In this thesis, the dynamical behaviour of machines is modelled using the multibody simulation approach. A multibody system may consist of rigid and flexible bodies which are joined using kinematic joint constraints while force components are used to describe the actuators. The strength of multibody dynamics relies upon its ability to describe nonlinearities arising from wearing of the components, friction, large rotations or contact forces in a systematic manner. For this reason, the interfaces between subsystems such as mechanics, hydraulics and control systems of the mechatronic machine can be defined and analyzed in a straightforward manner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nutrient load to the Gulf of Finland has started to increase as a result of the strong economic recovery in agriculture and livestock farming in the Leningrad region. Also sludge produced from municipal wastewater treatment plant of the Leningrad region causes the great impact on the environment, but still the main options for its treatment is disposal on the sludge beds or Landfills. The aim of this study was to evaluate the implementation of possible joint treatment methods of manure form livestock and poultry enterprises and sewage sludge produced from municipal wastewater treatment plants in the Leningrad region. The study is based on published data. The most attention was put on the anaerobic digestion and incineration methods. The manure and sewage sludge generation for the whole Leningrad region and energy potential produced from their treatment were estimated. The calculations showed that total amount of sewage sludge generation is 1 348 000 t/a calculated on wet matter and manure generation is 3 445 000 t/a calculated on wet matter. The potential heat release from anaerobic digestion process and incineration process is 4 880 000 GJ/a and 5 950 000 GJ/a, respectively. Furthermore, the work gives the overview of the general Russian and Finnish legislation concerning manure and sewage sludge treatment. In the Gatchina district it was chosen the WWTP and livestock and poultry enterprises for evaluation of the centralized treatment plant implementation based on anaerobic digestion and incineration methods. The electricity and heat power of plant based on biogas combustion process is 4.3 MW and 7.8 MW, respectively. The electricity and heat power of plant based on manure and sewage sludge incineration process is 3.0 MW and 6.1 MW, respectively.