997 resultados para imaging software
Resumo:
Determining groundwater flow paths of infiltrated river water is necessary for studying biochemical processes in the riparian zone, but their characterization is complicated by strong temporal and spatial heterogeneity. We investigated to what extent repeat 3D surface electrical resistance tomography (ERT) can be used to monitor transport of a salt-tracer plume under close to natural gradient conditions. The aim is to estimate groundwater flow velocities and pathways at a site located within a riparian groundwater system adjacent to the perialpine Thur River in northeastern Switzerland. Our ERT time-lapse images provide constraints on the plume's shape, flow direction, and velocity. These images allow the movement of the plume to be followed for 35 m. Although the hydraulic gradient is only 1.43 parts per thousand, the ERT time-lapse images demonstrate that the plume's center of mass and its front propagate with velocities of 2x10(-4) m/s and 5x10(-4) m/s, respectively. These velocities are compatible with groundwater resistivity monitoring data in two observation wells 5 m from the injection well. Five additional sensors in the 5-30 m distance range did not detect the plume. Comparison of the ERT time-lapse images with a groundwater transport model and time-lapse inversions of synthetic ERT data indicate that the movement of the plume can be described for the first 6 h after injection by a uniform transport model. Subsurface heterogeneity causes a change of the plume's direction and velocity at later times. Our results demonstrate the effectiveness of using time-lapse 3D surface ERT to monitor flow pathways in a challenging perialpine environment over larger scales than is practically possible with crosshole 3D ERT.
Resumo:
The primary goal of this study was to design a fluorescent E-selectin-targeted iodine-containing liposome for specific E-selectin imaging with the use of micro-CT. The secondary goal was to correlate the results of micro-CT imaging with other imaging techniques with cellular resolution, i.e., confocal and intravital microscopy. E-selectin-targeted liposomes were tested on endothelial cells in culture and in vivo in HT-29 tumor-bearing mice (n = 12). The liposomes contained iodine (as micro-CT contrast medium) and fluorophore (as optical contrast medium) for confocal and intravital microscopy. Optical imaging methods were used to confirm at the cellular level, the observations made with micro-CT. An ischemia-reperfusion model was used to trigger neovessel formation for intravital imaging. The E-selectin-targeted liposomes were avidly taken up by activated endothelial cells, whereas nontargeted liposomes were not. Direct binding of the E-selectin-targeted liposomes was proved by intravital microscopy, where bright spots clearly appeared on the activated vessels. Micro-CT imaging also demonstrated accumulation of the targeted lipsomes into subcutaneous tumor by an increase of 32 +/- 8 HU. Hence, internalization by activated endothelial cells was rapid and mediated by E-selectin. We conclude that micro-CT associated with specific molecular contrast agent is able to detect specific molecular markers on activated vessel walls in vivo.
Resumo:
Dans le cadre de la politique multiculturelle de protection des minorités menée par le gouvernement taïwanais, le Comité ministériel aux affaires hakka (keweihui) a planifié dix-huit « halls culturels hakkas » dans chaque comté et municipalité. L'article retrace le processus de création d'un de ces halls, dans le nord de l'île de Taiwan, au cours de la décennie 2000. L'aménagement du hall procède à l'incorporation d'artistes locaux dans une tradition nationale hakka réinventée. Il est montré comment sa genèse s'est produite à l'intersection d'une politique impulsée par « le haut » et d'un projet émanant d'acteurs locaux. L'article met en évidence comment les catégories yingti (hardware) et ruanti (software) président à sa fabrication et impliquent une opposition et une complémentarité entre « contenant » et « contenu », entre « État » et « société », qui agissent à toutes les étapes de sa mise en oeuvre.
Resumo:
El present projecte se centrarà en l'aplicació dels SIG a la prevenció dels incendis forestals a Catalunya. En concret en la localització de zones òptimes per a la instal lació de tallafocs, mitjançant la utilització dels programes lliures gvSIG i Sextant, a més de la base de dades (BDD) espacial PostgreeSQL / PostGIS.
Resumo:
In a global approach combining fluorescence recovery after photobleaching (FRAP), fluorescence correlation spectroscopy (FCS), and fluorescence resonance energy transfer (FRET), we address the behavior in living cells of the peroxisome proliferator-activated receptors (PPARs), a family of nuclear receptors involved in lipid and glucose metabolism, inflammation control, and wound healing. We first demonstrate that unlike several other nuclear receptors, PPARs do not form speckles upon ligand activation. The subnuclear structures that may be observed under some experimental conditions result from overexpression of the protein and our immunolabeling experiments suggest that these structures are subjected to degradation by the proteasome. Interestingly and in contrast to a general assumption, PPARs readily heterodimerize with retinoid X receptor (RXR) in the absence of ligand in living cells. PPAR diffusion coefficients indicate that all the receptors are engaged in complexes of very high molecular masses and/or interact with relatively immobile nuclear components. PPARs are not immobilized by ligand binding. However, they exhibit a ligand-induced reduction of mobility, probably due to enhanced interactions with cofactors and/or chromatin. Our study draws attention to the limitations and pitfalls of fluorescent chimera imaging and demonstrates the usefulness of the combination of FCS, FRAP, and FRET to assess the behavior of nuclear receptors and their mode of action in living cells.
Resumo:
Electromagnetic fields arising from magnetic resonance imaging (MRI) can cause various clinically relevant functional disturbances in patients with cardiac pacemakers. Consequently, an implanted pacemaker is generally considered a contraindication for an MRI scan. With approximately 60 million MRI scans performed worldwide per year, MRI may be indicated for an estimated majority of pacemaker patients during the lifetime of their pacemakers. The availability of MR conditional pacemakers with CE labelling is of particular advantage since they allow the safe use of pacemakers in MRI. In this article the current state of knowledge on pacemakers and MR imaging is discussed. We present the results of a survey conducted among Swiss radiologists to assess current practice in patients with pacemakers.
Resumo:
Rupture of a congenital aneurysm of the sinus of Valsalva is a rare congenital cardiac malformation. This case report describes a congenital aneurysm of the sinus of Valsalva which ruptured into the right ventricle in a 3-year-old girl. The exact route of the fistula through the cardiac walls and the localization of the rupture into the right ventricle was not completely defined by two-dimensional and color Doppler echocardiography and could be determined only by magnetic resonance imaging (MRI).
Resumo:
Calcinosis is a typical feature of systemic sclerosis (SSc) and can be found in many different tissues including the superficial soft tissues, periarticular structures, muscles, and tendons. It can also provoke erosive changes on bones. Investigation is conducted most often with plain radiographs. However, when a more detailed assessment is necessary, multidetector computed tomography (MDCT) is helpful owing to its multiplanar reformat (MPR) ability. The purpose of this review is to provide an overview of the various appearances of calcinosis in SSc patients as visualized at MDCT.
Resumo:
Purpose: In primary prevention of cardiovascular disease (CVD), it is accepted that the intensity of risk factor treatment should be guided by the magnitude of absolute risk. Risk factors tools like Framingham risk score (FHS) or noninvasive atherosclerosis imaging tests are available to detect high risk subjects. However, these methods are imperfect and may misclassify a large number of individuals. The purpose of this prospective study was to evaluate whether the prediction of future cardiovascular events (CVE) can be improved when subclinical imaging atherosclerosis (SCATS) is combined with the FRS in asymptomatic subjects. Methods: Overall, 1038 asymptomatic subjects (413 women, 625 men, mean age 49.1±12.8 years) were assessed for their cardiovascular risk using the FRS. B-mode ultrasonography on carotid and femoral arteries was performed by two investigators to detect atherosclerotic plaques (focal thickening of intima-media > 1.2 mm) and to measure carotid intima-media thickness (C-IMT). The severity of SCATS was expressed by an ATS-burden Score (ABS) reflecting the number of the arterial sites with >1 plaques (range 0-4). CVE were defined as fatal or non fatal acute coronary syndrome, stroke, or angioplasty for peripheral artery disease. Results: during a mean follow-up of 4.9±3.1 years, 61 CVE were recorded. Event rates the rate of CVE increased significantly from 2.7% to 39.1% according to the ABS (p<0.001) and from 4% to 24.6% according to the quartiles of C-IMT. Similarly, FRS predicted CVE (p<0.001). When computing the angiographic markers of SCATS in addition of FRS, we observed an improvement of net reclassification rate of 16.6% (p< 0.04) for ABS as compared to 5.5% (p = 0.26) for C-IMT. Conclusion: these results indicate that the detection of subjects requiring more attention to prevent CVE can be significantly improved when using both FRS and SCATS imaging.
Resumo:
L'objectiu d'aquest projecte és el d'integrar les aplicacions de Microsoft Office (Excel, Word i Access) mitjançant. NET i la creació de documents / plantilles necessàries per tal de crear un entorn que permeti a un professional / empresa gestionar de manera automatitzada les factures que envia als seus clients.
Resumo:
Injection drug use before and after liver transplantation: a retrospective multicenter analysis on incidence and outcome. Clin Transplant 2009 DOI: 10.1111/j.1399-0012.2009.01121.x. Background and aims: Injecting drug use (IDU) before and after liver transplantation (LT) is poorly described. The aim of this study was to quantify relapse and survival in this population and to describe the causes of mortality after LT. Methods: Past injection drug users were identified from the LT listing protocols from four centers in Switzerland and France. Data on survival and relapse were collected and used for uni- and multivariate analysis. Results: Between 1988 and 2006, we identified 59 patients with a past history of IDU. The mean age at transplantation was 42.4 yr and the majority of patients were men (84.7%). The indication for LT was for the vast majority viral cirrhosis accounting for 91.5% of cases, while alcoholic cirrhosis was 5.1%. There were 16.9% of patients who had a substitution therapy before and 6.8% who continued after LT. Two patients (3.4%) relapsed into IDU after LT and died at 18 and 41 months. The mean follow-up was 51 months. Overall survival was 84%, 66%, and 61% at 1, 5, and 10 yr after transplantation. Conclusions: Documented IDU was rare in liver transplanted patients. Past IDU was not associated with poorer survival after LT, and relapse after LT occurred in 3.4%.
Resumo:
El projecte genera un entorn personalitzat de gestió de factures electròniques utilitzant Visual Studio Tools, l¿entorn permet gestionar les bases de dades dels clients i dels productes oferts, generar factures i enviar-les via correu electrònic als clients en diferents formats (PDF o Word).
Resumo:
El present treball de final de carrera s¿ha realitzat en el context de l¿àrea temàtica .NET amb l¿objectiu de crear una aplicació basada en aquesta plataforma tecnològica, utilitzant VSTO (Visual Studio Tools for Office) i generant documentsamb certificat digital.
Resumo:
En la present memòria es presenta el treball realitzat en el projecte de desenvolupament de l'aplicació efactura que pretén fer la gestió de les factures de forma electrònica, sense l'ús de paper.