852 resultados para hydrology field work


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stereotactic radiosurgery treatments involve the delivery of very high doses for a small number of fractions. To date, there is limited data in terms of the skin dose for the very small field sizes used in these treatments. In this work, we determine relative surface doses for small size circular collimators as used in stereotactic radiosurgery treatments. Monte Carlo calculations were performed using the BEAMnrc code with a model of the Novalis 15 Trilogy linear accelerator and the BrainLab circular collimators. The surface doses were calculated at the ICRU skin dose depth of 70 m all using the 6 MV SRS x-ray beam. The calculated surface doses varied between 15 – 12% with decreasing values as the field size increased from 4 to 30 mm. In comparison, surface doses were measured using Gafchromic EBT3 film positioned at the surface of a Virtual Water phantom. The absolute agreement between calculated and measured surface doses was better than 2.5% which is well within the 20 uncertainties of the Monte Carlo calculations and the film measurements. Based on these results, we have shown that the Gafchromic EBT3 film is suitable for surface dose estimates in very small size fields as used in SRS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To obtain accurate Monte Carlo simulations of small radiation fields, it is important model the initial source parameters (electron energy and spot size) accurately. However recent studies have shown that small field dosimetry correction factors are insensitive to these parameters. The aim of this work is to extend this concept to test if these parameters affect dose perturbations in general, which is important for detector design and calculating perturbation correction factors. The EGSnrc C++ user code cavity was used for all simulations. Varying amounts of air between 0 and 2 mm were deliberately introduced upstream to a diode and the dose perturbation caused by the air was quantified. These simulations were then repeated using a range of initial electron energies (5.5 to 7.0 MeV) and electron spot sizes (0.7 to 2.2 FWHM). The resultant dose perturbations were large. For example 2 mm of air caused a dose reduction of up to 31% when simulated with a 6 mm field size. However these values did not vary by more than 2 % when simulated across the full range of source parameters tested. If a detector is modified by the introduction of air, one can be confident that the response of the detector will be the same across all similar linear accelerators and the Monte Carlo modelling of each machine is not required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The visual and multidimensional representations like images and graphical structures related to biology provide great insights into understanding the complexities of different organisms. Especially, life scientists use different representations of molecular structures to answer biological questions and to better understand cellular processes. Combining results from two field studies, we explore the role of molecular structures in life scientists’ current work from a humanfactors perspective. Our main conclusion is that different representations of molecular structures, due to their visual nature, are important for supporting collaboration, constructing new knowledge and supporting scientists’ professional activities in general.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Total scatter factor (or output factor) in megavoltage photon dosimetry is a measure of relative dose relating a certain field size to a reference field size. The use of solid phantoms has been well established for output factor measurements, however to date these phantoms have not been tested with small fields. In this work, we evaluate the water equivalency of a number of solid phantoms for small field output factor measurements using the EGSnrc Monte Carlo code. Methods The following small square field sizes were simulated using BEAMnrc: 5, 6, 7, 8, 10 and 30 mm. Each simulated phantom geometry was created in DOSXYZnrc and consisted of a silicon diode (of length and width 1.5 mm and depth 0.5 mm) submersed in the phantom at a depth of 5 g/cm2. The source-to-detector distance was 100 cm for all simulations. The dose was scored in a single voxel at the location of the diode. Interaction probabilities and radiation transport parameters for each material were created using custom PEGS4 files. Results A comparison of the resultant output factors in the solid phantoms, compared to the same factors in a water phantom are shown in Fig. 1. The statistical uncertainty in each point was less than or equal to 0.4 %. The results in Fig. 1 show that the density of the phantoms affected the output factor results, with higher density materials (such as PMMA) resulting in higher output factors. Additionally, it was also calculated that scaling the depth for equivalent path length had negligible effect on the output factor results at these field sizes. Discussion and conclusions Electron stopping power and photon mass energy absorption change minimally with small field size [1]. Also, it can be seen from Fig. 1 that the difference from water decreases with increasing field size. Therefore, the most likely cause for the observed discrepancies in output factors is differing electron disequilibrium as a function of phantom density. When measuring small field output factors in a solid phantom, it is important that the density is very close to that of water.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Due to their high spatial resolution diodes are often used for small field relative output factor measurements. However, a field size specific correction factor [1] is required and corrects for diode detector over-response at small field sizes. A recent Monte Carlo based study has shown that it is possible to design a diode detector that produces measured relative output factors that are equivalent to those in water. This is accomplished by introducing an air gap at the upstream end of the diode [2]. The aim of this study was to physically construct this diode by placing an ‘air cap’ on the end of a commercially available diode (the PTW 60016 electron diode). The output factors subsequently measured with the new diode design were compared to current benchmark small field output factor measurements. Methods A water-tight ‘cap’ was constructed so that it could be placed over the upstream end of the diode. The cap was able to be offset from the end of the diode, thus creating an air gap. The air gap width was the same as the diode width (7 mm) and the thickness of the air gap could be varied. Output factor measurements were made using square field sizes of side length from 5 to 50 mm, using a 6 MV photon beam. The set of output factor measurements were repeated with the air gap thickness set to 0, 0.5, 1.0 and 1.5 mm. The optimal air gap thickness was found in a similar manner to that proposed by Charles et al. [2]. An IBA stereotactic field diode, corrected using Monte Carlo calculated kq,clin,kq,msr values [3] was used as the gold standard. Results The optimal air thickness required for the PTW 60016 electron diode was 1.0 mm. This was close to the Monte Carlo predicted value of 1.15 mm2. The sensitivity of the new diode design was independent of field size (kq,clin,kq,msr = 1.000 at all field sizes) to within 1 %. Discussion and conclusions The work of Charles et al. [2] has been proven experimentally. An existing commercial diode has been converted into a correction-less small field diode by the simple addition of an ‘air cap’. The method of applying a cap to create the new diode leads to the diode being dual purpose, as without the cap it is still an unmodified electron diode.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When radiation therapy centres are equipped with two or more linear accelerators from the same vendor, they are usually beam-matched. This work tested the sensitivity of optically stimulated luminescence dosimeters (OSLDs) across matched linear accelerators. The responses were compared with an unshielded diode detector for varying field sizes. Clinical studies are currently done with thermoluminescent dosimeters (TLD), which absorb radiation then emit some levels of light determined by the radiation absorption when heated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Research shows that approximately half of creative practitioners operate as embedded creatives by securing gainful employment within organisations located in the field beyond their core discipline. This foregrounds the significance of having the skills necessary to successfully cross the disciplinary boundaries in order to negotiate a professional role. The multiple implications of such reframing for emerging creative practitioners who navigate uncertain professional boundaries include developing a skill of identifying and successfully targeting the shifting professional and industry coordinates while remaining responsive to changes. A further implication involves creative practitioners engaging in a continuous cycle of re-negotiation of their professional identity making the management of multiple professional selves - along with creating and recreating a meaningful frame of references such as the language around their emerging practice - a necessary skill. This chapter presents a case study of a set of Work Integrated Learning subjects designed to develop in creative industries practitioners the skills to manage their emerging professional identities in response to the shifts in the professional world.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nitrogenated carbon nanotips (NCNTPs) are synthesized by plasma-enhanced hot filament chemical vapor deposition from the hydrogen, methane, and nitrogen gas mixtures with different flow rate ratios of hydrogen to nitrogen. The morphological, structural, compositional, and electron field emission (EFE) properties of the NCNTPs were investigated by field emissionscanning electron microscopy, Raman spectroscopy, x ray photoelectron spectroscopy, and EFE high-vacuum system. It is shown that the NCNTPs deposited at an intermediate flow rate ratio of hydrogen to nitrogen feature the best size/shape and pattern uniformity, the highest nanotip density, the highest nitrogen concentration, as well as the best electron field emission performance. Several factors that come into play along with the nitrogen incorporation, such as the combined effect of the plasma sputtering and etching, the transition of sp 3carbon clusters to sp 2carbon clusters, the increase of the size of the sp 2 clusters, as well as the reduction of the work function, have been examined to interpret these experimental findings. Our results are highly relevant to the development of the next generation electron field emitters, flat panel displays, atomic force microscope probes, and several other advanced applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electron field emission (EFE) properties of nitrogenated carbon nanotips (NCNTPs) were studied under high-vacuum conditions. The NCNTPs were prepared in a plasma-assisted hot filament chemical vapor deposition system using CH4 and N2 as the carbon and nitrogen sources, respectively. The work functions of NCNTPs were measured using x-ray photoelectron spectroscopy. The morphological and structural properties of NCNTPs were studied by field emission scanning electron microscopy, micro-Raman spectroscopy, and x-ray photoelectron spectroscopy. The field enhancement factors of NCNTPs were calculated using relevant EFE models based on the Fowler-Nordheim approximation. Analytical characterization and modeling results were used to establish the relations between the EFE properties of NCNTPs and their morphology, structure, and composition. It is shown that the EFE properties of NCNTPs can be enhanced by the reduction of oxygen termination on the surface as well as by increasing the ratio of the NCNTP height to the radius of curvature at its top. These results also suggest that a significant amount of electrons is emitted from other surface areas besides the NCNTP tops, contrary to the common belief. The outcomes of this study advance our knowledge on the electron emission properties of carbonnanomaterials and contribute to the development of the next-generation of advanced applications in the fields of micro- and opto-electronics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monitoring therapeutic efficacy of antimalarial drugs is important because treatment failure rates are the primary basis for changing antimalarial treatment policy. An important aspect of efficacy studies is the use of PCR genotyping to distinguish recrudescent from new infections. The conclusions reached using this technique might be misleading if there is insufficient parasite diversity or a non-uniform haplotype frequency distribution in the study area. Statistical techniques can be used to overcome this problem, but only when data describing the haplotype frequency distribution are available. Therefore, assessing haplotype frequency and distribution should form an integral part of all studies investigating the therapeutic efficacy of antimalarial treatment regimes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, we report design, synthesis and characterization of solution processable low band gap polymer semiconductors, poly{3,6-difuran-2-yl-2,5-di(2- octyldodecyl)-pyrrolo[3,4-c]pyrrole-1,4-dione-alt-phenylene} (PDPP-FPF), poly{3,6-difuran-2-yl-2,5-di(2-octyldodecyl)-pyrrolo[3,4-c]pyrrole-1, 4-dione-alt-naphthalene} (PDPP-FNF) and poly{3,6-difuran-2-yl-2,5-di(2- octyldodecyl)-pyrrolo[3,4-c]pyrrole-1,4-dione-alt-anthracene} (PDPP-FAF) using the furan-containing 3,6-di(furan-2-yl)pyrrolo[3,4-c]pyrrole-1,4(2H,5H)-dione (DBF) building block. As DBF acts as an acceptor moiety, a series of donor-acceptor (D-A) copolymers can be generated when it is attached alternatively with phenylene, naphthalene or anthracene donor comonomer blocks. Optical and electrochemical characterization of thin films of these polymers reveals band gaps in the range of 1.55-1.64 eV. These polymers exhibit excellent hole mobility when used as the active layer in organic thin-film transistor (OTFT) devices. Among the series, the highest hole mobility of 0.11 cm 2 V -1 s -1 is achieved in bottom gate and top-contact OTFT devices using PDPP-FNF. When these polymers are used as a donor and [70]PCBM as the acceptor in organic photovoltaic (OPV) devices, power conversion efficiencies (PCE) of 2.5 and 2.6% are obtained for PDPP-FAF and PDPP-FNF polymers, respectively. Such mobility values in OTFTs and performance in OPV make furan-containing DBF a very promising block for designing new polymer semiconductors for a wide range of organic electronic applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We consider a discrete agent-based model on a one-dimensional lattice, where each agent occupies L sites and attempts movements over a distance of d lattice sites. Agents obey a strict simple exclusion rule. A discrete-time master equation is derived using a mean-field approximation and careful probability arguments. In the continuum limit, nonlinear diffusion equations that describe the average agent occupancy are obtained. Averaged discrete simulation data are generated and shown to compare very well with the solution to the derived nonlinear diffusion equations. This framework allows us to approach a lattice-free result using all the advantages of lattice methods. Since different cell types have different shapes and speeds of movement, this work offers insight into population-level behavior of collective cellular motion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aerial applications of granular insecticides are preferable because they can effectively penetrate vegetation, there is less drift, and no loss of product due to evaporation. We aimed to 1) assess the field efficacy ofVectoBac G to control Aedes vigilax (Skuse) in saltmarsh pools, 2) develop a stochastic-modeling procedure to monitor application quality, and 3) assess the distribution of VectoBac G after an aerial application. Because ground-based studies with Ae. vigilax immatures found that VectoBac G provided effective control below the recommended label rate of 7 kg/ha, we trialed a nominated aerial rate of 5 kg/ha as a case study. Our distribution pattern modeling method indicated that the variability in the number of VectoBac G particles captured in catch-trays was greater than expected for 5 kg/ha and that the widely accepted contour mapping approach to visualize the deposition pattern provided spurious results and therefore was not statistically appropriate. Based on the results of distribution pattern modeling, we calculated the catch tray size required to analyze the distribution of aerially applied granular formulations. The minimum catch tray size for products with large granules was 4 m2 for Altosid pellets and 2 m2 for VectoBac G. In contrast, the minimum catch-tray size for Altosid XRG, Aquabac G, and Altosand, with smaller granule sizes, was 1 m2. Little gain in precision would be made by increasing the catch-tray size further, when the increased workload and infrastructure is considered. Our improved methods for monitoring the distribution pattern of aerially applied granular insecticides can be adapted for use by both public health and agricultural contractors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mining industry is highly suitable for the application of robotics and automation technology, since the work is arduous, dangerous, and often repetitive. This paper presents a broad overview of the issues involved in the development of a physically large and complex field robotic system—a 3500-tonne mining machine (dragline). Draglines are “walking cranes” used in open-pit coal mining to remove the material covering a coal seam. The critical issues of robust load position sensing, modeling of the dynamics of the electrical drive system and the swinging load, control strategies, the operator interface, and automation system architecture are addressed. An important aspect of this system is that it must work cooperatively with a human operator, seamlessly passing control back and forth in order to achieve the main aim—increased productivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim A recent Monte Carlo based study has shown that it is possible to design a diode that measures small field output factors equivalent to that in water. This is accomplished by placing an appropriate sized air gap above the silicon chip (1) with experimental results subsequently confirming that a particular Monte Carlo design was accurate (2). The aim of this work was to test if a new correction-less diode could be designed using an entirely experimental methodology. Method: All measurements were performed on a Varian iX at a depth of 5 cm, SSD of 95 cm and field sizes of 5, 6, 8, 10, 20 and 30 mm. Firstly, the experimental transfer of kq,clin,kq,msr from a commonly used diode detector (IBA, stereotactic field diode (SFD)) to another diode detector (Sun Nuclear, unshielded diode, (EDGEe)) was tested. These results were compared to Monte Carlo calculated values of the EDGEe. Secondly, the air gap above the EDGEe silicon chip was optimised empirically. Nine different air gap “tops” were placed above the EDGEe (air depth = 0.3, 0.6, 0.9 mm; air width = 3.06, 4.59, 6.13 mm). The sensitivity of the EDGEe was plotted as a function of air gap thickness for the field sizes measured. Results: The transfer of kq,clin,kq,msr from the SFD to the EDGEe was correct to within the simulation and measurement uncertainties. The EDGEe detector can be made “correction-less” for field sizes of 5 and 6 mm, but was ∼2% from being “correction-less” at field sizes of 8 and 10 mm. Conclusion Different materials will perturb small fields in different ways. A detector is only “correction-less” if all these perturbations happen to cancel out. Designing a “correction-less” diode is a complicated process, thus it is reasonable to expect that Monte Carlo simulations should play an important role.